• Title/Summary/Keyword: 요골맥파

Search Result 31, Processing Time 0.024 seconds

Detection of Radial Pulse Wave by Photoplethysmogram (광전용적맥파를 이용한 요골동맥 맥파 검출)

  • 정동근;김광년;연규선;최병철;서덕준
    • Journal of Life Science
    • /
    • v.13 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes radial pulse waves recorded by photoplethysmogram with 940 nm wavelength infra red light. Radial pulse waves were varied according to the recording site. When recorded on the skin over radial artery, the radial pulse wave was inverted, comparing to the photoplethysmogram at fingertip. The mechanism of inverted pulse wave seemed to be caused by the change of the blood volume in the subcutaneous tissue between radial artery and the skin, which was reduced during systolic period and increased during diastolic period of the cardiac cycle. These results suggest that radial arterial wall may reflect infra red ray.

Development of a Test Jig for Examination of Radial Pulse Waveform Variations at Different Hold-down Pressures (가압에 따른 요골동맥 맥파 변동 측정을 위한 테스트 지그 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.203-204
    • /
    • 2008
  • 한의학 진단의 중요 요소인 맥진을 자동화한 맥진기에서뿐만 아니라 비관혈적 심혈관 기능 평가를 위해서 요골동맥 맥파 측정이 널리 활용되고 있다. 요골동맥 맥파는 피험자의 생리적, 병리적 원인을 통제하더라도 가압력이 변함에 따라 형태가 달라지며, 어느 시점 맥파를 피험자의 상태를 대표하는 맥파로 해야 할지에 대한 명확한 기준이 없어 맥압이 최대가 되는 시점의 맥파를 사용하고 있다. 그러나, 맥파가 측정되는 가압력 범위뿐만 아니라 맥압이 최대가 되는 시점이 피험자마다 다르기 때문에 정확한 대표 맥파를 획득하기 위해서는 보다 가압력 단계를 늘려야 하며, 결과적으로 측정시간이 보다 길어지게 될 것이다. 본 논문에서는 최소한의 가압단계로도 보다 정확히 대표 맥파를 획득할 수 있는 방법을 개발할 수 있도록, 정밀 제어가 가능한 가압 로봇 축, 가압에 의해 눌리는 피부이동 거리 측정을 위한 레이저 센서, 가압에 따른 피부 반발력과 맥파를 측정할 수 있는 압력 센서로 구성된 테스트 지그를 개발하였다. 이를 통해 모터 이동 스텝 수에 따른 피부 이동 거리 특성, 피부 이동 거리에 따른 맥파 변화 특성 등을 관찰할 수 있었으며, 향후 효과적인 대표 맥파 획득 방법을 개발할 수 있을 것으로 기대한다.

  • PDF

Arterial blood pressure measurement using pulse transit time (맥파전달시간을 이용한 동맥혈 혈압측정)

  • Hwang, Dae-Seok;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.265-267
    • /
    • 2007
  • 고혈압을 진단하고 치료함에 있어 정기적인 혈압의 측정 및 관리는 매우 중요하다. 본 논문에서는 요골 동맥혈에서 혈압 측정을 하기 위한 심전도 측정기와 광용적맥파 측정기를 설계하여 구성하였으며, 이를 이용한 맥파 전달 시간 측정을 LA(Left Arm), RA(Right Arm)에서 심전도와 요골동맥에서 광 용적맥파 신호를 측정하였다.

  • PDF

The Heart Rate Monitoring System using Inverted Photoplethysmography (반전 용적맥파 신호를 이용한 심박 모니터링 시스템)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.105-111
    • /
    • 2012
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes implementation a photoplethysmography monitoring system that uses 780nm and 940nm length infrared light in radial artery. That system used combinations of 8 LEDs and 2 photoelectricities. When recorded on the skin over radial artery, the radial pulse wave was inverted. The mechanism of inverted pulse wave skin, which was reduced during systolic period and increase during diastolic period of the cardiac cycle. Through this system, we discovered optimal environments and combinations of sensors in both penetration type and reflection type. These results suggest that radial arterial wall way reflect infrared ray.

15 channel tonometric radial pulse measurement system using air cuff pressure (공압 가압 방식의 15채널 맥파 측정 시스템)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.205-206
    • /
    • 2008
  • 한의학에서 손목의 맥파를 손으로 짚어 보고 파형의 변화로써 병변의 원인을 파악하는 것은 기본적인 진단 방법이다. 진단을 위해 요골동맥의 촌, 관, 척 세 부위의 맥파를 수지를 통해 일정 가압을 하며 맥의 깊이, 강약, 빠르기 등을 촉진을 통해 맥상을 분석한다. 본 연구에서는 촌, 관, 척 부위를 동시 측정하기 위해 각 부위에 5개의 압력센서 어레이가 적용된 15채널 맥진기를 구성하였다. 또한 요골 동맥 부위에 적정 가압을 유지하기 위해 공기 커프를 이용한 공압 가압 방식을 적용하였다. 본 가압 방식을 통해 요골 동맥 부위에 연속적이며 정밀 가압제어가 가능하였다.

  • PDF

A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography (광전용적맥파를 이용한 요골동맥 산소포화도 측정 시스템의 연구)

  • Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.11-18
    • /
    • 2010
  • In this study, the pulse of radial artery and oxygen saturation are detected using photoelectric plethysmograph method. Using our device designed reflection type, we can detect the reflected light by radial artery and by switching circuit, we can also separate to 625nm band signal and 940nm band signals. The separated signals are converted as a pulse data by the pulse signal processing circuit. In this study, the reflection type of oxygen saturation calculation method is applied instead of the transmission type because of the reflection type sensor is used to measure the radial artery. As a result, we can detect about 97% accuracy of the oxygen saturation compare with the conventional method. For the accurate signals, the wrist band with sensor was designed and fixed on the radial artery. As a result, this wrist band type sensor was applicable to prevent position errors from motion artifact and could increase the accuracy during the measuring.

Detection of Radial Pulse by Combinational Fiber-optic Transducer (조합형 광섬유 트랜스듀서에 의한 요골맥파의 검출)

  • Park, Seung-Hwan;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.197-202
    • /
    • 1998
  • The human pulse wave is a vital biosignal that includes the diagnostic data related with the heart and the cardiovascular system of human body. Based on the mechanical transducing method, a pulse detection transducer using optical fiber was developed to acquire the pulses non-invasively. To improve the detection efficiency, we proposed a new design that consists of two combinational parts; detecting part, which is in contact with the pulsating skin and transmits the displacement motion of the pulsating skin to the sensing part, and sensing part, which converts the physical quantity transmitted from the detecting part to electronic signal. By using the new method, we confirmed that the proposed transducer can detect the C point(incisura) and the T wave(tidal wave) which is not easily detected by existing transducers.

  • PDF

Multi-Point Radial Artery Pulse Wave Transducer using Pneumatic System (공압 방식에 의한 다지점 요골 맥파 검출 장치)

  • 이종진;정민석;황성하;이종현;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.243-248
    • /
    • 2001
  • A radial artery pulse wave is well known as a good mans to diagnose human body condition in th field of Chinese medical science. Information about constitution as well as organs can be obtained by detecting the artery pulse wave. Recently, the information about the human body constitution may be utilized in accelerating the recovery process of the patient on the basis of comprehensive diagnosis. A radial artery pulse wave is considered as one of promising means in examining the human body constitution. Since the examination has been conducted by the feeling of finger, the diagnosis may occasionally have uncertainty or fatal error. In this paper, a new measuring system is suggested and developed to examine the pattern of a pulse wave correctly. The system is composed of four pressure vessels, pressure sensors and air supplying pumps. One of them is utilized for appropriately pressing the radial artery, three of them for detecting pressure change in several mmHg level. The detected data is shown and discussed.

  • PDF

Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device (영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석)

  • Kim, Dong-Young;Lee, Sang-Suk;Hyeon, Seog-San;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.146-151
    • /
    • 2014
  • The pulse waveforms of a carotid artery in the neck and a radial artery in the hand wrist were individually measured by using clip-type pulsimeter equipped with a permanent and Hall device. The pulse transit time and the pulse wave velocity obtained through comparison of two pulse waveforms were analyzed each other. A value of the pulse wave velocity was about 8.5 m/s similar to one measured by a conservative method. This result suggests that the clip-type pulsimeter as the reproducible and reliable one oriental diagnostic medical device can be predicted to any atherosclerosis state in the cardiac circulatory system.

Contrivance of a Radial Pulse Measuring System with Variable Contact Pressure (압력 조절식 맥진 센서의 개발)

  • 윤영준;조정현;정현민;신학수;소광섭
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.567-572
    • /
    • 1999
  • 혈관내 맥검출 센서인 MPX2300DT1을 요골동맥상에서 무침습적으로 맥파를 검출할 수 있도록 실리콘 고무를 부착하여 맥진 센서로 활용하였다. 또한 추의 무게에 의해 압력을 조절하여 그것에 따른 맥파의 변화를 볼 수 있는 맥진 시스템을 제작하였다. 맥진 센서의 압력에 따른 출력전압의 선형성을 확인하였으며 추의 무게에 따른 맥파의 진폭과 주기 변화를 조사하였다.

  • PDF