• Title/Summary/Keyword: 외부저항

Search Result 458, Processing Time 0.034 seconds

Study on the Thermal Dissipation Characteristics of 16-chip LED Package with Chip Size (16칩 LED 패키지에서 칩 크기에 따른 방열특성 연구)

  • Lee, Min-San;Moon, Cheol-Hee
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.4
    • /
    • pp.185-192
    • /
    • 2012
  • p-n junction temperature and thermal resistance of Light Emitting Diode (LED) package are affected by the chip size due to the change of the thermal density and the external quantum efficiency considering the heat dissipation through conduction. In this study, forward voltage was measured for two different size LED chips, 24 mil and 40 mil, which consist constitute 16-chip package. p-n junction temperature and thermal resistance were determined by thermal transient analysis, which were discussed in connection with the electrical characteristics of the LED chip and the structure of the LED package.

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF

A Study on the Electrical Properties of Transition Metal Oxides Thin Film Device (금속산화 박막 전기소자의 전기적 특성 연구)

  • Choi, Sung-Jai
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.9-14
    • /
    • 2011
  • We have investigated the electrical properties of $AlO_x$ thin film device. The device has been fabricated top-bottom electrode structure and its transport properties are measured in order to study the resistance change. Electrical properties with linear voltage sweep on a electrodes are used to show the variation of resistance of $AlO_x$ thin film device. Fabricated $AlO_x$ thin film device with MIM structure is changed from a high conductive On-state to a low conductive Off-state by the external linear voltage sweep. It is found that the initial resistance of the $AlO_x$ thin film is low-resistance On state and reversible switching occurs. Consequently, we believe $AlO_x$ thin film is a promising material for a next-generation nonvolatile memory and other electrical applications.

Thermal Resistant Characteristics of Flowable Backfill Materials Using Surplus Soil for Underground Power Utilities (굴착잔토를 재활용한 지중 전력케이블 유동성 뒤채움재의 열저항 특성)

  • Oh, Gidae;Kim, Daehong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.10
    • /
    • pp.15-24
    • /
    • 2010
  • In the case of underground power utilities pipe such as circular pipe, the most difficult problem is low compaction efficiency of the bottom of pipe inducing the failure of utilities. To overcome this problem, various studies have been performed and one of these is CLSM(Controlled Low Strength Materials) accelerated flow ability. But underground power utilities pipe backfill materials is also needed to have good thermal property that can dissipate the heat as rapidly as it is generated. So, in this study, we performed thermal resistancy test for various materials such as sand, weathered soil, clay and mixed soil to analyze the thermal characteristics of CLSM(Controlled Low Strength Materials) with accelerated flow ability for various conditions(water content, unit weight, void ratio, curing time) and to evaluate the applicability for backfill material of underground power utilities pipe. The test results of 16 specimens for thermal resistancy test showed good thermal property that maintained below $85^{\circ}C\;cm/W$.

Evaluation of Crack Resistant Performance in Cement Mortar with Steel Fiber and CSA Expansion Admixture (CSA 팽창재를 혼입한 강섬유 보강 모르타르의 균열 저항성능 평가)

  • Ahn, Jung-Kil;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2014
  • Steel fiber is a effective composite for crack resistance and improve structural performance under tensile loading. This study presents an evaluation of crack resistance and structural performance in cement mortar with steel fiber and expansion agent through internal chemical prestressing. For this work, cement mortar samples with 10% replacement of cement binder with CSA (Calcium-Sulfo-Aluminate) expansion agent and 1% volume ratio of steel fiber are prepared. Including basic mechanical properties, initial cracking load and fracture energy are evaluated in cement mortar beam with notch. Initial cracking load and fracture energy in cement mortar with CSA and steel fiber increase by 1.75 and 1.41~1.53 times compared with those in cement mortar with steel fiber. With optimum mix design for steel fiber and CSA expansive agent, the composite with chemical prestressing can be applied to various members and effectively improve crack resistance to external loading.

Modelling of Transfer Impedance of based an Express Bus Terminal use Behavior (고속버스터미널 이용자의 환승행태에 기반을 둔 환승저항 모형 구축 연구)

  • Kim, Hwang Bae;Kwon, Young Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2D
    • /
    • pp.99-103
    • /
    • 2010
  • It is necessary to improve transfer impedance of express bus terminal users in order to increase the usage of public transportation. This study constructed a model for calculating transfer impedance based on bodily sensational transfer time in express bus terminal and calculated transfer impedance on major express bus terminals in Korea. The study results show that the addition of 100 meter exterior walking distance increases 3 minute travel time, 100 meter interior walking distance increases 5 minute travel time, 100 stairways increase 13 minute travel time, and escalators decreases 3 minute travel time. The calculated transfer impedance based on bodily sensational transfer time in this study can be utilized as objective criteria to compare transfer conditions of different bus terminals and to prioritize them for facility improvement. The calculated transfer impedance also can be used as facility guidelines for designing a new transit center.

Modelling of Transfer Impedance of Urban Rail Station (도시철도역사의 환승저항 모형 구축 연구)

  • Kim, Hwang Bae;Choi, Jin Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1D
    • /
    • pp.11-15
    • /
    • 2010
  • It is necessary to improve transfer impedance of Urban Rail Station station users in order to increase the usage of public transportation. This study constructed a model for calculating transfer impedance based on bodily sensational transfer time in Urban Rail Station stations and calculated transfer impedance on major Urban Rail Station stations in Korea. The study results show that the addition of 100 meter exterior walking distance increases 2 minute travel time, 100 meter interior walking distance increases 3 minute travel time, 100 stairways increase 4 minute travel time, and escalators decreases 1 minute travel time. The calculated transfer impedance based on bodily sensational transfer time in this study can be utilized as objective criteria to compare transfer conditions of different Urban Rail Station stations and to prioritize them for facility improvement. The calculated transfer impedance also can be used as facility guidelines for designing a new transit center.

A study for test method of wire connectors (전선 연결단자의 시험방법 고찰)

  • Park, Jeong-Seok;Han, Gyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.54-56
    • /
    • 2003
  • 전기제품에 전선을 연결하는 수단으로써 단말장치를 사용한다. 단말장치는 작업자가 전선을 제품에 편리하게 연결시키도록 하는 전선결합수단이다 전기제품을 장시간 사용하다보면 외부환경 및 제품의 내구성의 변화로 인해 각종 사고가 발생한다. 그 중에 전선이 제품에 제대로 연결되어야만 제품의 성능이 발휘될 것이고 전선연결부위가 제품 성능에 영향을 주어서는 안된다. 제품에 전선의 결합강도, 전선의 접촉저항에 따른 온도 영향등을 규격에서는 이러한 영향 요소들을 평가/측정하기 위한 시험이 제시되어 있다.

  • PDF

A Study of Characteristic Analysis for Small Buried type Permanent Magnet Synchronous Generator (소형 내삽형 영구자석 동기발전기의 특성해석에 관한 연구)

  • Hong, Sun-Ki;Kim, Bum-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1091-1092
    • /
    • 2011
  • 영구자석형 발전기는 외부의 여자 전원이 필요 없어서, 비상 전원으로 뿐 아니라, 소형 발전설비에서의 발전기의 여자 전원으로도 사용될 수 있다. 특히, 내삽형 영구자석형 동기발전기는 자석보다 극의 자속밀도를 더 높일 수 있어, 저가, 고성능 발전기 제작이 가능하다. 본 연구에서는 이러한 발전기에 필요한 발전기 해석기술을 개발한다. 정밀 해석을 위한 등가회로를 모델링하고, 이로부터 해석적인 결과를 얻는다. 전기자 저항을 고려한 경우와 고려하지 않은 경우를 비교하여 해석의 타당성을 검증한다.

  • PDF

Effects of Crack Velocity on Fracture Resistance of Concrete (콘크리트의 파괴저항에 대한 균열속도의 영향)

  • Yon, Jung-Heum
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.52-59
    • /
    • 2003
  • Tests of concrete CLWL-DCB specimens had been conducted with displacement-controlled dynamic loading. The crack velocities for 381mm crack extension were 0.80 mm/sec ~ 215m/sec. The external work and the kinetic and strain energies were derived from the measured external load and load-point displacement. The fracture resistance of a running crack was calculated from the fitted curves of the fracture energy required for the tests. The standard error of the fracture energy was less than 3.2%. The increasing rate of the fracture resistance for 28 mm initial crack extension or micro-cracking was relatively small, and then the slope of the fracture resistance increased to the maximum value at 90∼145 mm crack extension depending on crack velocity. The maximum fracture resistance remained for 185 mm crack extension, and then the faster crack velocity showed the faster decreasing rate of the maximum fracture resistance. The maximum fracture resistance increased proportionally to the logarithm of the crack velocity from 142 N/m to 217 N/m when the crack velocity was faster than 0.273 m/sec. The maximum fracture resistance of the fastest tests was similar to the average fracture energy density of 215 N/m. To measure the fracture resistance of concrete, the stable crack extension should be larger than 90∼145 mm depending on crack velocity.