• Title/Summary/Keyword: 외부방사선치료

Search Result 235, Processing Time 0.022 seconds

DOUBLE TEETH IN MAXILLARY PERMANENT INCISORS : CASE REPORTS (상악 전치부에 발생한 이중치: 증례보고)

  • Kim, Mi-Ni;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taek;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.119-125
    • /
    • 2009
  • Fusion and gemination are irregularities in tooth development. It is often difficult to differentiate between gemination and fusion and it is common to refer to these anomalies as 'double teeth'. The deciduous teeth are most commonly involved, but in 0.1% of cases permanent teeth are affected, in which case aesthetic, funtional and periodontal problems can result. Double teeth present great difficulties in management and required a multidisciplinary approach. The central groove on the labial and palatal surfaces of a double tooth is extremely prone to caries, therefore early 'fissure sealing' is essential. In permanent dentition, surgical separation of fused teeth may be possible with subsequent orthodontic alignment and restorative treatment as needed to reshape the crown. Reshaping or reduction of a double tooth with a single canal may be attempted by modifying the appearance of the labial groove and the use of composite tints but is often impossible and extraction may be the only alternative. Orthodontic treatment and prosthetic replacement is then required. Implants may be an option for adolescents. The present study describes three clinical cases of double teeth in the position of the maxillary permanent incisors. The first case demonstrates an example of multidisciplinary care including surgical intraoral hemisection, root canal therapy, restorative and orthodontic treatment. The second and third cases describe the external and internal morphology of the two fused teeth by means of three dimensional dental computer tomography.

  • PDF

A Clinical Review of Primary Tracheal Carcinoma (원발성 악성기관종양의 임상적 고찰)

  • Ryu, Jeong-Seon;Cho, Hyun-Myung;Yang, Dong-Gyoo;Lee, Hong-Lyeol;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Shin, Kye-Chul;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.766-775
    • /
    • 1997
  • Background : Primary malignant tumors of the trachea are extremely rare entities and account for a mere 0.1 per cent of all malignancies of the respiratory tract. Because of vague localizing signs, symptoms and a usually negative routine chest film, the patients with tracheal tumors are often treated for asthma or chronic obstructive pulmonary disease for considerable period of time before correct diagnosis. Method : We have made a review of the 17 cases of primary tracheal tumors in recent 15 years. We reviewed the clinical features including history of smoking and respiratory symptoms, the official readings of initial routine chest film, the cytologic examination of sputum, the time of delay in diagnosis, and the response according to the therapeutic modalities. Results : Eight out of 9 patients with squamous cell carcinoma(SCC) were above 50 years old, five out of 6 patients with adenoid cystic carcinoma(ACC) were below 50 years old. The most common location of primary tracheal tumors was the upper one-third of trachea in 8 cases(47%). The most frequent symptoms were dyspnea in 13/17 cases(76%) and then stridor or wheezing, cough. and sputum in order. The routine chest roentgenographic examinations were not helpful to diagnose tracheal carcinoma and the cytologic examinations of sputums were helpful to diagnose tracheal carcinoma in only one case with adenocarcinoma. The mean times of delay in diagnosis of patients with sec and ACC were 5 months and 24.9 months respectively. We had bronchial asthma in 8 cases(47%) and tracheal tumors in 4 cases(23%) as initial clinical impression. Conclusion : We would like to perform more comprehensive diagnostic tools(high KVP technique, the fibroptic bronchoscopic examination, chest CT scan etc.) in patients who had the suggestive points for the tracheal tumorse(1. unexplained hemoptysis or hoarsness, 2. inspiratory wheezing or stridor, 3. wax and waning of dyspnea according to changes of position, 4. progressive asthmatics unresponsive to antiasthmatic therapy) and radical resection of tumor or external radiation therapy with curative aim as possible.

  • PDF

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

Observation on The Frequency of Chromosomal Aberration and Changes in Number of Peripheral Lymphocytes in Radioactive Iodine Treatment (방사성옥소 투여에 따른 말초혈액 림프구 수의 변화 및 염색체이상 빈도의 관찰)

  • Koo, Chun-Hee;Shin, Min-Ho;Park, Young-Ju;Lee, Jung-Yim;Park, Tae-Yong;Lee, Jae-Yong;Kim, Chong-Soon;Han, Seung-Soo;Kim, Kwang-Hoe;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.343-349
    • /
    • 1995
  • Background : For biological dosimetry of radiation exposure, both observing hematologic change and calculating Ydr by chromosomal analysis as biological indicators are widely used. However, due to the lack of studies on biological dosimetry of radiation dose absorbed in the body such as in the cases of radioactive iodine therapy, the maximal and safe dose is not well known, nor is the extent to which the body can safely endure radiation exposure. Purpose : To investegate the practical applicability of hematologic changes and Ydr as an indicator for estimating radiation exposure, to patients with thyroid diseases after doses of radioactive iodine. Material and Methods : 5 patients with hyperthyroidism and 35 patients who have had thyroid cancer operation were under treatment with radioactive iodine, changes in number of lymphocytes were tracked and Ydr was calculated for more than 2 months by chromosomal analysis in peripheral lymphocytes. Results ; 1) The number of lymphocytes began to decrease 2 weeks after doses of radioactive iodine, and reached the nadir after 6 and 8 weeks, then gradually recovered. 2) The nadir count of lymphocytes was reversely correlated with the administered dosage of radioactive iodine. 3) Ydr was generally stable between 2 and 8 weeks. 4) The maximal value of Ydr was correlated with the administered dosage of radioactive iodine. 5) Ydr value at the 2nd week increased with augmented dosage of radioactive iodine. 6) Ydr value at the 2nd week was correlated with fall of lymphocyte count. Conclusion : Patients must be closely observed, because temporary bone marrow suppression and slight chromosomal aberration can be produced by even generally used dosages of radioactive iodine for diagnosis and therapy. Maximal percent fall of lymphocyte count, Ydr at the 2 week interval and maximal Ydr can be used as the biological predictor of administered dosage of radioactive iodine.

  • PDF

Steroid Responsive Tremor Syndrome in a Maltese Dog (말티즈 견에서 발생한 스테로이드 반응성 진전 증후군)

  • Kang, Byeong-Teck;Jung, Dong-In;Park, Chul;Kim, Ju-Won;Kim, Ha-Jung;Lim, Chae-Young;Ko, Ki-Jin;Cho, Sue-Kyung;Lee, So-Young;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.337-339
    • /
    • 2006
  • A 4-year-old, spayed female Maltese dog was presented for evaluation of acute onset of generalized tremor, right-sided head tilt, horizontal nystagmus, and mild ataxia with 4-day duration. However, the dog was bright, alert, and responsive. The neurological examinations revealed that bilateral horizontal-, positional nystagmus, and mild ataxia. Menace responses were also absent in both eyes. Typically, moderate generalized intension tremors were noted in four limbs and the head. No abnormalities were found in hemogram, radiography, and magnetic resonance imaging(MRI). Cytologic examination of cerebrospinal fluid(CSF) revealed a mild nonsuppurative inflammation. Thus, steroid responsive tremor syndrome(SRTS) was strongly suspected because of its inflammatory and idiopathic features. The dog excellently responded to immunosuppressive doses of corticosteroid. Therefore, we definitively diagnosed the dog as SRTS based on the exclusion of other causes of the tremor, clinical signs, and response to treatment. This is a first case report of SRTS in our country and we here describe clinical and neurological features in SRTS.

Treatment Results of Increased Dose External Beam Radiation Therapy for Unresectable Esophageal Cancer (절제 불가능한 식도암에서 고선량 외부조사 방사선 치료의 결과)

  • Lee, Seung-Heon;Lee, Seok-Ho;Lee, Kyu-Chan;Shin, Dong-Bok;Shim, Sun-Jin;Lee, Jae-Ik
    • Korean Journal of Bronchoesophagology
    • /
    • v.15 no.2
    • /
    • pp.49-56
    • /
    • 2009
  • Purpose : To evaluate the treatment outcome for patients with locally advanced, unresectable esophageal cancer treated with relatively high dose radiation therapy(RT). Materials and Methods : From January 2000 to December 2008, 32 patients with locally advanced unresectable or medically inoperable esophageal cancer were treated with radiation therapy(RT) with or without concurrent chemotherapy. Ten patients were excluded from analysis because of distant metastasis and drop off. Patient distributions according to AJCC stages II, III IVa were 7(31.8%), 12(54.6%), 3(13.6%) respectively. The locations of tumor were cervical/upper thorax 3 (13.6%), mid thorax 13(59.1%), and lower thorax/abdominal 6(27.3%), respectively. Eleven patients received RT only, and 11 patients received cisplatin based concurrent chemoradiotherapy(CCRT). Median radiation dose was 65 Gy(range 57.6~72 Gy). Results : The median follow-up was 9.1 months(range 1.9~43.8 months). The response rates for complete response, Partial response, stable disease and Persistent disease were 6(27.3%), 11(50.0%), 4(18.2%) and 1(4.5%), respectively. Two patients(9.1%) suffered from esophageal stenosis and stents were inserted. Two patients(9.1%) had Grade 3 radiation pneumonitis and one of them expired due to acute respiratory distress syndrome(ARDS) at 36 days after completion of radiation therapy. The recurrence rate was 11(50.0%). The patterns of recurrence were persistent disease and local progression in 5(22.7%), local recurrence 3(13.7%) and concomitant local and distant recurrence in 3(13.7%). The overall survival(OS) rate was 32.1% at 2 years and 21.4% at 3 years(median 12.0 months). Disease free survival(DFS) rate was 17.3% at 2 and 3 years. All patients who had no dysphagia at diagnosis showed complete response after treatment and 100% OS at 3 years(p=0.0041). The OS for above 64.8 Gy group and 64.8 Gy or below group at 3 years were 60.6% and 9.1%(p=0.1341). The response to treatment was the only significant factor affecting OS(p=0.004). Conclusion : Relatively high dose radiation therapy in unresectable esophageal cancer tended to have a better outcome without increased complication rate. Further study with more patients is warranted to justify improved result.

  • PDF

Effect of Transverse Magnetic Field on Build-up Region of 6 MV Photon Beam (6 MV 광자선의 선량 상승 영역에 대한 자기장 영향)

  • Shin, Seong Soo;Choi, Wonsik;Ahn, Woo Sang;Kwak, Jungwon
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.1
    • /
    • pp.18-22
    • /
    • 2017
  • The purpose of this study was to present an improved method of dose modulation over the increase of build-up for existing 6 MV photon beam. Two neodymium permanent magnets with a strength of 0.5 T (Tesla) were applied with a magnetic field perpendicular to the photon beam. The effects of dose on build-up region with or without the magnetic field were measured according to the magnet-to-magnet distance (MMS) and the magnet-to-surface distance (MSD). For MMS = 6 cm and MSD = 2.5 cm, $D_{0mm}$, $D_{2mm}$, $D_{5mm}$, and $D_{10mm}$ showed improved doses of 6.8 %, 14.6 %, 6.9 %, and 2.1 %, respectively, as compared with 6 MV open beam. In this study, the device with low strength magnetic field can be applied directly to the outside of the human body when the target volume located close to the skin is delivered with radiation. It is expected that the method of build-up modulation using a low strength magnetic field will be feasible in the clinical applications.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Expression of Growth Factors and Secretory Leukocyte Protease Inhibitor (SLPI) in RAW264.7 Cells after Lipopolysaccharide (LPS) Stimulation (대식세포주 (RAW264.7)에서 박테리아성 지질다당류 (LPS) 자극에 의한 분비백혈구단백분해효소억제제 (SLPI)와 성장인자들의 발현)

  • Son, Wook-Hee;Choi, Baik-Dong;Jeong, Soon-Jeong;Wang, Guan-Lin;Hwang, Ho-Keel;Jeong, Moon-Jin
    • Applied Microscopy
    • /
    • v.37 no.2
    • /
    • pp.93-102
    • /
    • 2007
  • Secretory leukocyte protease inhibitor (SLPI) was known as one of bacterial lipopolysaccharide (LPS)-induced products of macrophage. Macrophages play an important role in the development of inflammatory responses by secreting an array of cytokines and chemokines in a tissue microenvironment. To identify the function and relationship between potent growth factors and SLPI after LPS stimulation, we conducted reverse transcriptase polymerase chain reaction (RT-PCR) and Western blots for the detection of mRNA and protein expression of SLPI and growth factors such as VEGF, PDGF, bFGF after 100 ng LPS stimulation on the RAW264.7 cells. The result of RT-PCR was showed SLPI mRNA expression was increased from 60 min to 48h in RAW 264.7 cells after incubation with LPS. VEGF and PDGF mRNA was expressed highly at initial stage by LPS stimulation. The mRNA of bFGF and type I collagen was very weakly expressed after LPS stimulation. SLPI protein level was increased likely the mRNA levels in RAW 267.7 cells. Additionally, phase contrast and scanning electron microscopic observation demonstrated that the LPS induce the change of morphology of the RAW264.7 cells. From these results, it suggest that expression of SLPI by LPS treatment may associate with VEGF and PDGF expression in RAW264.7 cells.

The effects of mandibular setback osteotomy on the oropharyngeal airway space in mandibular prognathic patients (하악전돌 환자에서 하악골 후퇴수술이 기도공간에 미치는 영향)

  • Kim, Hyo-Young;Choi, Hyun-Gue;Kim, Eun-Kyung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.733-741
    • /
    • 1997
  • As a result of surgical orthodontic treatment of mandibular prognathism, changes take place in the skeletal and soft orofacial components. Although some investigators had stated that permanent reduction of airway space was observed after mandibular setback surgery, it was not clear that this permanent reduction was sustained during long-term follow-up. The purpose of this study was to assess the changes in oropharyngeal airway space and soft tissue orofacial component following the mandibular setback surgery and during the follow-up period. The correlation between the changes of the oropharyngeal airway space and the changes of other soft tissue orofacial component was also assessed. The findings of this study were as follows ; 1. The oropharyngeal airway space area decreased following mandibular setback surgery for mandibular prognathism and continued to decrease during the follow-up period(p<0.05). 2. The pharyngeal depth at Xi point level and the 2nd cervical vertebra point level decreased after the surgery and remained during the follow-up period(p<0.05). The decrease of these pharyngeal depth was correlated with the decrease of oropharyngeal airway space area(p<0.01). 3. The decrease of pharyngeal depth at the 3rd and 4th cervical vertebra point level was not significant after the surgery and during the follow up period. 4. The hyoid bone moved downward after the surgery(p<0.05), but returned to its original position during the follow-up period. 5. The length & height of tongue and the Position of epiglottis base did not change significantly(p>0.05). 6. The soft palate was displaced posteriorly after the surgery and remained to its changed position during the follow-up period(p<0.05) due to posterior displacement of tongue. The changes of soft palate were significantly correlated with the decrease of oropharyngeal airway space area(p<0.01). 7. The narrowing of oropharyngeal airway space was due to the posterior displacement of tongue above the level of epiglottis tip. The posterior displacement of tongue following mandibular setback osteotomy remained during the follow-up period.

  • PDF