A Primary Study on the Enhancement of Efficiency in the Computer Cooling System using Entrance Tube of Outer Air (외부공기 유입관을 이용한 컴퓨터 냉각시스템의 효율향상에 관한 연구)

  • Kim, S.H.;Kim, M.H.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.56-61
    • /
    • 2009
  • In recent years, since the continuing increase in the capacity in personal computer such as the optimal performance, high quality and high resolution image, the computer system's components produce large amounts of heat during operation. This study analyzes and investigates the ability and efficiency of a cooling system inside a computer by means of central processing unit (CPU) and power supply cooling fan. This research was conducted to enhancement of efficiency of the cooling system inside the computer by making a structure which produces different air pressures in an air inflow tube. Consequently, when temperatures of the CPU and room inside computer were compared with a general personal computer, temperatures of the tested CPU, the room and the heat sink were as low as $5^{\circ}C$, $2.5^{\circ}C$ and $7^{\circ}C$ respectively. In addition to, revolution per minute (RPM) was shown as low as 250 after 1 hour operation. This research explored the possibility of enhancing the effective cooling of high-performance computer systems.