• Title/Summary/Keyword: 외부고정법

Search Result 56, Processing Time 0.022 seconds

The Use of a Porcine Cancellous Bone Graft for Arthrodesis of Bilateral Antebrachiocarpal Luxation in a Dog (양측 전완앞발목관절 탈구의 관절고정술을 위한 돼지뼈 해면골이식의 적용)

  • Heo, Su-Young;Lee, Ki-Chang;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.259-262
    • /
    • 2012
  • A seven-year-old Yorkshire terrier 2.1 kg was admitted with a 2 months history of sever bilateral forelimb lameness and joint instability. Examination and radiographs revealed caudal luxation of bilateral antebrachiocarpal joint. Luxation of bilateral antebrachiocarpal (ABC) joint in a toy breed dog was treated with pancarpal arthrodesis. Modified external skeletal fixator (ESF) (type IIb) with polymethylmethacrylate (PMMA) was utilized in this case. Porcine cancellous bone graft (PCBG) was inserted to fill the joint space in carpus. The clinical and radiographic assessments of joint after the surgical procedure proved that PCBG can be used a promising alternative to Autogenous cancellous bone graft (ACBG).

Use of Cross Pins and Temporal External Skeletal Fixator for Stabilization of a Tibial Physeal Fracture in a Korean Native Calf (한우 송아지의 정강뼈 성장판 골절에서의 교차핀과 임시 외부 골격 고정장치의 이용)

  • Heo, Su-Young;Kim, Eun-Ju;Kim, Min-Su;Lee, Ki-Chang;Kim, Nam-Soo;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.198-201
    • /
    • 2012
  • A one-month-old, male Hanwoo calf was presented to Chonbuk Animal Medical Center with non-weight bearing lameness on its right hindlimb. The radiograph and CT scan showed a Salter-Harris III fracture at the distal tibia. Following open reduction, the fracture was stabilized by cross-pins. A temporal external skeletal fixator was used as an additional support for 5 weeks. 5 weeks after surgery, bone fracture had successfully healed with no complication. At 2 years after surgery, the calf could walk almost normally although intermittent weight-bearing lameness after active exercise. This is a rare case that the combined use of temporal external fixation and cross-pins fixation was sufficiently effective for treating a distal tibial physeal fracture in a calf.

Analysis and Design of BLDC Motor Using Rare Earth Magnet (희토류 자석 BLDC 전동기의 해석 및 설계)

  • Chang, Cheul-Hyeok;Lee, Dong-Whan;Chung, Tae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1186-1188
    • /
    • 2005
  • 본 논문에서는 8극 12슬롯 내전형 BLDC 전동기를 기본 모델로 하고, 이를 자기저항법 및 유한요소법을 이용하여 해석 및 설계를 하고자 한다. 본 논문에서 설계대상으로 하는 내전형 BLDC 전동기는 기존에 사용중인 모델로서, 외부의 고정 전기자는 기존의 모델에 맞도록 외경을 그대로 유지하면서 Teeth 등을 설계변수로 하였고, 내부의 회전 자석계자는 기존에는 페라이트 자석을 사용하였으나 전동기의 성능 향상을 위해서 희토류 자석으로 대체하였다. 그리고 이로인한 고정자의 포화가 일어나지 않도록 최적 설계를 하였다. 유한요소법을 적용하여 자속분포, 코깅 토오크, 토오크 등을 해석하였고, 고정자와 슬롯의 최적화를 통하여 토오크 및 전동기의 성능을 향상시켰다.

  • PDF

An Experimental Method for the Evaluation of Dead Load Stress in Existing Concrete Bridges (콘크리트 교량의 고정하중 응력에 관한 실험적 측정방법)

  • Park, Dae Sung;Kim, Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.701-706
    • /
    • 2006
  • This paper describes an attempt to develop a practical method for the measurement of dead load stress in existing concrete bridges. In most cases, the dead load stress was determined by various theoretical calculations. However, the theoretical calculation cannot always provide a sufficient information on the current stress state due to lots of uncertainty. The key idea incorporated with this paper is the partial sectioning method which is able to estimate current stress state in concrete bridges subjected to dead load. The proposed method is applied to the safety assessment of actual concrete bridges and the applicability of this system is investigated.

Tension Estimation of External Tendons in PC Bridges Using Vibration Measurement Method (진동 측정법을 이용한 PC교량 외부텐던의 장력 추정)

  • Park, Sung Woo;Jung, Ha Tae;Jung, Soo Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.84-92
    • /
    • 2014
  • In this study, vibrational tendon tension measurement methods are applied to estimate tension of external tendons used in segmental post-tensioned bridges. The acceleration of various length type of tendons is measured and natural frequencies are obtained using FFT (Fast Fourier Transform). The obtained natural frequencies are within 1% error regardless of sensor direction and location. On the basis of natural frequency of tendon, estimation of the tendon tension is performed by using many types of solutions such as string theory equation, multi mode estimation, practical formula estimation and stiff string with clamped-clamped boundary conditions. The results are compared with each other and have shown that the flexural stiffness is not negligible in tendons of this type causing the vibration mode to be inharmonically related. The results have shown that the method using stiff string equation with clamped-clamped boundary conditions is more accurate than the other methods. Application example of in-service bridges has shown that force distribution effects from friction at deviation blocks can be effectively detected.

Finite Element Analysis of Stress Distribution on Supporting Bone of Cement Retained Implant by Oblique Loading (경사하중에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분포)

  • Lee, Myung-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.343-349
    • /
    • 2014
  • The dental osseointegration implant should be enough to endure occlusion load and it's required to have efficient design and use of implant to disperse the stress into bones properly. Solidworks as a finite element analysis program for modeling and analysis of stress distribution was used for the research. The simple crown model was designed on applying conjoined condition with tightening torque of 20 Ncm of a abutment screw between a cement retained implant abutment and a fixture. A $45^{\circ}$ oblique loading from lingual to buccal side on buccal cusps of crown and performed finite element analysis by 100 N of external load. The results by a analysis for stress distribution of supporting bones of fixture were as below. The von Mises stress was concentrated on the upper side of supporting compact bone regardless of the diameters and lengths of fixture, and the efficiency result of stress reduction was increase of fixture's diameter than it's length. Therefore, it's effective to use wider fixture as possible to the conditions of supporting jaw bone.

Kinetic Study on the Immobilized Penicillin Amidase in a Differential Column Reactor (Differential column reactor에 있어서 고정화페니실린 아미다제의 반응속도론에 관한 연구)

  • Park, Jong-Moon;Park, Cha-Yong;Seong, Baik-Lin;Han, Moon-Hi
    • Microbiology and Biotechnology Letters
    • /
    • v.9 no.3
    • /
    • pp.165-171
    • /
    • 1981
  • The penicillin amidase from Escherichia coli (ATCC 9637) was immobilized by entrappment in gelatin and DEAE-cellulose mixture cross-linked with glutaraldehyde, and the kinetics in a differential column reactor was studied. The optimal operating condition of a differential reactor was reasonably met when the enzyme loading was 1g, and 30 mM substrate solution in 0.1 M phosphate buffer (pH 8.0) was fed at flow rate 4$m\ell$/min and 4$0^{\circ}C$. The optimal pH and temperature were found to be 8.0 and 55$^{\circ}C$, respectively. The Michaelis-Menten constant was 4.8 mM while the maximum velocity was 308 units/g of the immobilized enzyme under the condition of the differential reactor. The effect of substrate inhibition disappeared in the immobilized enzyme preparation. The differential reactor was proved to be good for studying the true kinetics since the pH drop and the external diffusional resistance could be eliminated.

  • PDF

A Study on Revolving Characteristics According to Stator Shape in 5MW Class Brushless DC Motor for Ship Propulsion (선박용 5MW급 BLDC 추진전동기의 고정자 형상에 따른 회전특성에 관한 연구)

  • Kim, Dong-Sok;Sung, Il-Kwon;Kim, Jang-Mok;Park, Gwan-Soo;Kim, Han-Deul;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.47-49
    • /
    • 2005
  • 최근의 선박 추진시스템은 기존의 엔진, 터빈 둥의 구동 원에서 선박의 발전기로부터 선체 외부의 프로펠러와 일체형으로 구성된 모터를 구동하여 추진하는 전기추진식으로 변화되고 있다. 특히, 히토류계 영구자석재질의 발달로 인하여 대형선박의 추진을 위한 대용량 자석계자형 BLDC와 영구자석형 동기전동기의 설계 연구가 활발히 이루어지고 있다. 그러나 여전히 MW급 대용량 BLDC 추진전동기의 설계 연구는 미흡한 실정이다. 이에 본 연구에서는 5MW급 대용량 BLDC 추진전동기 설계 연구를 진행하였으며, 그 결과 슬롯 수에 의한 고정자 형상이 다른 3가지 타입의 인버터 내장형 MW급 모델을 설계하였다. 그리고 이들 모델들을 정자계 유한요소법을 이용하여 해석함으로써 고정자 형상에 따른 회전특성을 분석하였고, 이를 바탕으로 본 설계 조건에 적합한 고정자 형상 설계 방향을 제시하였다.

  • PDF

A Case of External Skeletal Fixation for Treatment of Bilateral Mandibular Fracture in a Dog (개에서 외부고정법을 이용한 양측성 하악골절의 치유 일례)

  • 구자민;김현희;박대식;장홍희;이효종;이후장;송해룡;이용훈;정종태
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.134-137
    • /
    • 2003
  • A 5-year-old, male mixed breed dog was presented to Gyeongsang National University Animal Hospital for bilateral mandibular open fracture by bite. The dog had loss of the teeth and injury of the oral mucosa. Radio-graphic and blood examinations were conducted. Fracture lines were observed between first premolar and second premolar, but temporomandibular luxation was not observed on radiographs. In serum analysis, elevated levels of CPK and LDH were found. The dog was anesthetized and prepared for aseptic surgery. Acrylic external skeletal fixator with Kirschiner wire was applied. Pin loosening and malalignment of the right fracture line was observed at 7 weeks after surgery. We applied Kirschner-Ehmer fixator and half pins during the second surgical procedure. At 4 weeks after a second surgical procedure, the fixator and pins were removed from mandible. The fractures were healed with no complications.

Staring Characteristic of Wound Rotor Induction Motor by New Winding Method (새로운 권선법에 의한 권선형 유도전동기의 기동특성)

  • 강만원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.27-31
    • /
    • 1999
  • This paper covers starting characteristics and design of wound motor induction rmtor can used to double excited induction mootor. They are employing in many electrical equiprrent system of industrial field The stator is satre as that of conventional induction motor. But rotor was rewind with new style, as result both of starting torque and operating efficiency could be high, But starting current could be small. Could obtain the satre result as that of conventional induction rmtor with external resistance on the rotor. The structure could be simple, system cost could be low and the maintanence free, Because of no slip rings, no brushes and no external resistance.stance.

  • PDF