• Title/Summary/Keyword: 외기 온도

Search Result 231, Processing Time 0.032 seconds

Properties of Hot Weather Nuclear Power Plant Concrete with Water Cooling Method and Retarding used (배합수 냉각방법 및 지연제 사용에 따른 서중 원전콘크리트의 특성)

  • Lee, Seung-Han;Jung, Yong-Wook;Jang, Seok-Soo;Yeo, In-Dong;Choi, Jong-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4602-4609
    • /
    • 2013
  • In summer and winter, the difference between the temperature during the day and that during the night is high, which leads to various problems during concrete placement, such as cracks and defects in the concrete as well as low durability and strength. Although nuclear power plant concrete is widely used for placement in all seasons, particular attention must be paid to its quality during the summer. Therefore, we evaluated the effects of a cooling method for mixing water, which is a commonly used hot weather precooling method, and the use of a retarder, on the characteristics of Nuclear Power Plant concrete. In the cooling method for mixing water, cold water at 5 was used, with 50% of the water content consisting of ice flakes. The effects of using a retarder were evaluated by reviewing the characteristics of the cement at the unset stage and after hardening. To evaluate the characteristics of the unset cement, we measured the slump, air volumes, setting times, and pressure strengths after hardening. Furthermore, we measured the heat of hydration at different temperatures; the loss of heat was minimized using insulation. Both the slump time and the complete ageing time of the air volume were found to be 120 min at $20^{\circ}C$ and 40 min at $40^{\circ}C$. In the case when the cooling method for mixing water was used and in the case when a retarder was used, the initial and final sets by penetration resistance were delayed, and the delay decreased with increasing air temperature. For the heat of hydration, the cooling method for mixing water not only lowered the maximum temperature but also delayed its attainment. However, the use of a retarder had no effect on the maximum temperature. Moreover, in the early ages (e.g., 3 and 7 days), the pressure strength of the concrete was lower than that of plain cement. However, the strength of 28-day concrete met the standard construction specifications.

The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House (윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향)

  • Kim, Hyeon-Tae;Song, Jun-Ik;Choi, Hong-Lim
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The study was conducted to investigate the effects of climate on indoor environment of a swine house with natural. This study was tested in the beef swine stall at Young-in, Kyung-ki do. The test was experimented for the effect of interior environment by the outdoor environment and the interior-pan. The results are as follows. 1. In test 1 ($T_{out}$ : $25.7^{\circ}C$, without fan), an indoor air flow pattern was showed that entered from sidewall winch-curtain to went out of a indoor by the ridge winch-curtain. And the velocity of a section of the center was measured two times as large as the velocity of the floor. It is the acceleration of the velocity by thermal buoyancy. And, the entered air was rapidly dissipated by flow energy. So that in the swain livestock with sidewall winch-curtain is effected by thermal buoyancy. And the air temperature of the indoor was distributed more higher as compared with the outdoor temperature. This result is caused by the sensible heat from swine and the ventilation is restricted. 2. In test 2 (($T_{out}$ : $25.7^{\circ}C$, with fan), the velocity of a section of the center was measured more higher as compared with the test 1. And the variance of air velocity was distributed higher as compared with the test 1. This result is showed dead region of air flow with a fan operation. And, the variance of gas density was distributed lower as compared with the test 1.

Methods that can be Substituted for Earth Healing of Seedling by Using the Plastic Vinyl and their Micro-climatical Characteristics (프라스틱비닐제품(製品)을 이용(利用)한 가식대치방법(假植代置方法)과 미기상학적(微氣象學的) 특성(特性))

  • Ma, Sang Kyu;Lee, Jang Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.47 no.1
    • /
    • pp.44-51
    • /
    • 1980
  • In order to find out the suitable methods that can omit the earth healing and increase the survival through improving the seedling-healing and transportable methods. Several trials with plastic vinyl have been done and its results are as follows: 1. Though P. rigitaeda seedling have been stored in the black and white vinyl sack for 35 days in the storehouse. This seedling have survived with very high percentage as Table 1. This means that the earth healing work at the nursery or planting area can be omitted if seedling sould be stored in the storehouse by using the vinyl sack. The possibilities of long-period storage in the black and white vinyl sack seem to be come from the reasons that air humidity in the sack is nearly 100% and its air temperature is only around $15^{\circ}C$ with very little difference between day and night time. This sack also can be utilized in place of the planting sack, and though this sack with seedling have been laid under direct sunshine for 1 to 2 days. Any difference between the sack stored in the storehouse has not been observed on the survival specially Table 2. 2. When the bundled seedling have been covered with the black and white vinyl instead of earth healing, even if these seedling have been laid for 18 days under the vinyl. This seedling show us high survival as Table 3. High humidity with nearly 95%, very little difference of air temperature between day and night time under the vinyl and not so big difference between out-and inside temperature could be reasons of high survival to be considered. So through covering by the black and white vinyl. The labour power for earth healing works can be saved also. 3. In order to protect the healed seedling from the direct sunshine and the eva-transpiration. Black vinyl net and reed mat could be effective for this purpose. Because vinyl net could intercept around one to third, reed mat two to third of total solar energy and also suppress more than 50% of total water loss by the transpiration.

  • PDF

Economic Evaluation of ATES Heat Pump System (ATES 열펌프 시스템의 경제성 평가)

  • Kim, Namtae;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.199-199
    • /
    • 2011
  • ATES(Aquifer Thermal Energy Storage) 열펌프 시스템은 기존의 다양한 열원 적용 시스템 대비 효율이 우수한 것으로 알려져 유럽과 미국에서 건물 냉난방 시스템으로 적용되고 있다. 특히, ATES 시스템은 기존의 냉난방 시스템 대비 경제성이 우수한 것으로 알려져 있으나 국내에서는 이에 대한 연구 결과는 전무한 실정이다. 본 연구에서는 ATES 열펌프 시스템의 실증 성능 결과를 분석하였으며, LNG 보일러와 에어컨을 사용하는 기존의 냉난방 시스템을 비교시스템으로 ATES 열펌프 시스템의 경제성 평가를 수행하였다. ATES 시스템의 연간 실증 성능 실험결과 ATES 시스템은 외기온도와 무관하게 연중 안정적인 성능을 나타내었다. 경제성 평가시에 생애주기법(Life Cycle Cost)을 적용하여 ATES 열펌프 시스템의 설치 및 운전에 필요한 총 소요비용을 산정하고, 이 결과를 바탕으로 투자회수기간법을 통해 ATES 시스템의 투자회수 기간을 산정하였다. 생애주기법 적용 시에 현재가치법을 사용하였으며, 현재가치법은 수명주기에 발생하는 모든 투자비용과 절감액을 일정한 시점을 기준으로 등가환산하는 방법을 의미한다. 현재가치법에 사용되는 현재가치는 초기비용과 현재가치계수의 곱으로 나타나는데, 여기에서 현재가치계수는 임의의 이자율로 일정기간 동안 정기적인 할부금액이 적립될 때의 현재금액을 구하기 위해 사용하는 계수를 의미한다. 전기와 LNG는 각각 2009년 7월의 (주)한국전력공사와 (주)한국가스공사의 고시요금을 적용하였다. 본 시스템은 실증 설비용량인 20RT를 대상 건물로 가정하였고, 초기투자비는 크게 공사비와 냉난방 설비 구입비로 구성되어 있으며, 기본적인 물가지표는 (사)한국물가정보(KPI)의 고시 데이터를 참조하였다. 각 시스템의 초기투자비는 ATES 시스템이 비교대상 기존 냉난방 시스템 대비 5.7배 높게 나타났다. 일일 8시간 사용기준으로 계절별 전력요금을 고려한 연간운전 비용은 ATES 시스템이 기존 시스템 대비 냉난방 시에 각각 77%와 16%를 나타내어 운전비용이 연간 절감되었고, 난방 운전 시 절감 비율이 냉방시보다 크게 나타났다. 두 시스템에 대한 생애주기비용을 산정하기 위하여 에어컨과 보일러의 기존시스템과 ATES 시스템의 가용연수를 모두 20년으로 설정하였고, 유지보수 비용은 초기투자비용의 2%로 설정하고, 할인율은 은행 예금이자를 기준으로 5%로 설정하였다. 전기와 LNG의 요금 상승률은 (사)한국물가정보를 바탕으로 각각 2%와 8%로 가정하였다. 이러한 조건에서 생애주기법을 이용한 경제성평가는 ATES 시스템의 경우 생애운전비용이 초기투자비용보다 작게 나타났으며, 기존 냉난방 시스템은 생애운전비용이 초기투자비용에 비하여 높게 나타났다. 본 연구 대상 ATES 열펌프 시스템의 실증 성능 데이터와 기존 문헌으로부터 얻은 냉난방 시스템의 성능 결과를 이용하여 생애주기 비용을 적용한 결과 ATES 시스템의 기존 시스템 대비 투자회수 기간은 6.62년으로 나타났다. 특히, 본 연구에서는 ATES 시스템이 국내 최초로 적용됨에 따라 스크린 등의 부품을 다소 고가의 제품으로 시스템에 적용하였으므로 ATES 시스템의 신뢰성과 안정성이 확보되면 초기 투자비 감소가 가능할 것으로 예상되며, 기존 시스템 대비 투자회수 기간은 더욱 감소될 수 있을 것으로 예상된다.

  • PDF

Development of Long-Term Electricity Demand Forecasting Model using Sliding Period Learning and Characteristics of Major Districts (주요 지역별 특성과 이동 기간 학습 기법을 활용한 장기 전력수요 예측 모형 개발)

  • Gong, InTaek;Jeong, Dabeen;Bak, Sang-A;Song, Sanghwa;Shin, KwangSup
    • The Journal of Bigdata
    • /
    • v.4 no.1
    • /
    • pp.63-72
    • /
    • 2019
  • For power energy, optimal generation and distribution plans based on accurate demand forecasts are necessary because it is not recoverable after they have been delivered to users through power generation and transmission processes. Failure to predict power demand can cause various social and economic problems, such as a massive power outage in September 2011. In previous studies on forecasting power demand, ARIMA, neural network models, and other methods were developed. However, limitations such as the use of the national average ambient air temperature and the application of uniform criteria to distinguish seasonality are causing distortion of data or performance degradation of the predictive model. In order to improve the performance of the power demand prediction model, we divided Korea into five major regions, and the power demand prediction model of the linear regression model and the neural network model were developed, reflecting seasonal characteristics through regional characteristics and migration period learning techniques. With the proposed approach, it seems possible to forecast the future demand in short term as well as in long term. Also, it is possible to consider various events and exceptional cases during a certain period.

  • PDF

A Study on the Optimization of Heat Flux in Engine Room of Auxiliary Power Unit for Self-Propelled Artillery (자주포용 보조동력장치 엔진룸의 열유동 최적화에 관한 연구)

  • Noh, Sang Wan;Park, Young Min;Kim, Sung Hoon;Lee, Jae Dong;Kim, Byung Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.629-635
    • /
    • 2019
  • In this study, we analyzed the effect of FAN and oil cooler application on APU. MIL-STD-810 was applied to the atmospheric environment and radiation dose in order to perform thermal flow analysis. The heat flow was analyzed for the case in which the inlet / outlet fan was applied (Case 1), the case in which the inlet fan and the oil cooler were applied (Case 2), and the case in which the inlet / outlet fan and the oil cooler were applied (Case 3). As a result, it was confirmed that the cylinder head temperature of Case 3 was 21.4 times lower than that of Case 1 and 8.0 times lower than that of Case 2. Experiments were conducted under the same ambient conditions in order to examine the validity of the results. The numerical values and experimental results showed a difference of less than 7%. Through this, we were able to confirm that the APU heat flow optimization model satisfies the design conditions. The results of this study are expected to be used as basic data for optimizing heat flow of APU.

Structural Integrity Evaluation of Mechanically Fastened FRP Beams Under the Effects of Sustained Loads and Environments (지속하중과 환경영향을 받은 MF-FRP 보강보의 구조건전성 평가)

  • Lee, Jae-Ha;Kim, Woo-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Mechanically fastening FRP (MF-FRP) strips using nails and anchors, has been shown to provide a more ductile behavior to the strengthened structural element than using bonded FRP. To further advance the state of the knowledge on this strengthening method, the current study examined environmental effects for six months on MF-FRP beams. Reinforced concrete beams strengthened with mechanically fastened FRP strips and subjected to sustained loads for six months were exposed to outdoor weather and constant high temperatures ($40^{\circ}C$). For comparison, the behavior of RC beam with and without sustained loads was evaluated. Results from flexural tests did not show any significant degradation or change of failure mode as a result of sustained load and of environmental effects such as high temperatures and outdoor weather over a period of six months. Failure of the beams was governed by FRP delamination followed by concrete crushing as not much load applied to the nail and anchors because of slip effects.

Changes in Riboflavin and Ascorbic Acid Content during Ripening of Kimchi (절임조건별(條件別) 배추에 의한 김치의 숙성중(熟成中) Riboflavin과 Ascorbic Acid의 함량변화(含量變化))

  • Rhie, Seung-Gyo;Kim, Hwa-Za
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.13 no.2
    • /
    • pp.131-135
    • /
    • 1984
  • For the convenience of transportation and improvement of the utility of raw chinese cabbage during harvest season, the condition of pretreatment for the raw chinese cabbage with pickle has been examined by preserving for one to ten days. The changes in the content of riboflavin and ascorbic acid in kimchi (pickled-seasoned chinese cabbage), which was manufactured by using the pickled cabbage as a main raw material, along with ginger, garlic, red pepper powder, rad-dish and fermented shrimp as seasonings, during ripening were investigated with specially referred to palatability. The yield of the pickled cabbage compared to the raw cabbage after treating with pickle was 62 to 65% in volume and 15 to 42% in weight. After 10 days of pickling of the chinese cabbage, one-third of total ascorbic acid was diminished but no change in riboflavin content was observed. During ripening of kimchi, riboflavin content in kimchi processed with the pickled cabbage has not been changed compared to the content in convention- ally made kimchi, however, slight decrease in ascorbic acid content in the kimchi processed with the pickled cabbage was as certained. The result of organoleptic test showed that the kimchi processed with the pickled cabbage became inferior to the conventionally made kimchi with the days of ripening.

  • PDF

Physical characteristics of agricultural reservoir in korea (국내 농업용 저수지의 물리적 특성)

  • Choi, Sunhwa;Lee, Jinkyung;Ye, Hanhee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.544-544
    • /
    • 2015
  • 국내에는 17,500여개의 농업용 저수지가 전국적으로 분포하고 있으며, 이들 저수지는 인공호소이다. 농업용 저수지의 총 유효저수량은 2,838백만$m^3$에 달하고 있으며, 전체 수리답의 약 76%에 해당하는 593천ha의 농경지에 물을 관개하고 있다(2013농업생산기반통계연보). 최근 농어촌지역의 도농복합형태 개발 및 관광지, 유원지화로 농업용 저수지 유역의 오염원이 지속적으로 증가하는 추세에 있으며, 이로 인해 농업용수 수질이 지속적으로 악화되고 있다. 특히, 늦봄에서 초가을까지 외기온도 상승 및 저수율 저하와 함께 부영양화 증가, 녹조 대발생 등으로 수질오염도가 급상승하고 있으며, 이로 인해 호 내 물고기 폐사, 악취발생 등으로 민원이 다수 발생하고 있다. 본 연구에서는 농업용 저수지의 물리적 특성을 분석하여 농업용 저수지 수질개선을 위한 기초자료로 활용하고자 하였다. 농업용 저수지 17,489개소를 수혜면적별로 분류해 보면 5ha이하가 7,808개소(44.7%), 5~10ha이하 4,277개소(24.5%), 10~20ha 2,772개소(15.9%), 20~30ha 797개소(4.6%), 30~40ha 385개소(2.2%), 40~50ha 238개소(1.4%), 50ha이상 1,201개소(6.9%)로 구성되어 있어 50ha이하가 전체의 93.1%에 이르고 있다. 유효저수량별 분포현황은 10천$m^3$이하가 7,996개소(45.7%), 10~50천$m^3$ 6,420개소(36.7%), 50~100천$m^3$ 1,003개소(5.7%), 100~300천$m^3$ 868개소(5.0%)로 전체 시설 중 50천$m^3$이하가 전체 저수지의 82.4%로 대부분이 소규모 저수지임을 알 수 있다. 농업용 저수지를 유효수심별로 구분해보면 1m이하가 전체의 26.6%, 3m이하가 전체의 77.1%, 5m이하가 전체의 91.1%로 국내 대부분의 저수지들은 수심이 5m 이하의 저류지 형태의 저수지임을 알 수 있다. 저수지를 유역배율(유역면적/만수면적)에 따라 구분해보면 유역배율 3이하가 전체의 1.2%이고, 5이상이 전체의 97.4%를 차지하고 있다. 일반적으로 유역배율이 3이상이면 부영양화에 취약한 호소로 분류되고 있다. 국내 농업용 저수지는 대부분이 수심이 낮고, 유효저수량이 소규모이며, 유역배율이 3이상인 호소가 대부분으로 태생적으로 수질오염 및 부영양화에 취약한 구조로 되어 있음을 알 수 있다. 농업용 저수지 수질개선을 위한 종합계획 수립시에는 유입수 및 호내 대책과 함께 호소의 물리적 조건을 개선시키는 방안에 대해서도 검토가 요구된다. 특히 저수지 신규 설치시에는 수량관리 뿐만 아니라 수질도 함께 고려된 물리적 인자에 대한 설계가 이루어져야 할 것으로 판단된다.

  • PDF

DO concentration assessment on the micro-bubble generator operation in agricultural lake (농업용 호소의 마이크로버블 현장적용에 따른 DO 농도 평가)

  • Choi, Sunhwa;Lee, Seungheon;Jang, Kyusang;Lee, Jinkyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.431-431
    • /
    • 2016
  • J 호소는 1942년도에 충청남도 아산시 선장면에 설치된 농업용 저수지로서, 현재 COD, TN, TP 모두 등급외의 수질상태를 보이고 있다. J 호소 상류 유역은 축산농가가 다수 위치하고 있으며, 설치된 지 70년이 지난 노후화된 저수지로 고농도의 오염물질 유입뿐만 아니라 호소 바닥의 오염 퇴적물에 의한 내부 부하가 중요한 수질오염원이 되고 있다. 호소의 수질은 현재 COD 10.6~16.5 mg/L, Chl-a $75mg/m^3$ 이상으로 수질오염도가 매우 높으며, 특히 늦봄에서 초가을까지 외기온도 상승 및 저수율 저하와 함께 부영양화 증가, 녹조 대발생 등으로 호 내 물고기 대량 폐사 및 악취발생 등으로 민원이 다수 발생하고 있다. 이러한 현상의 직접적인 원인은 수중의 DO 농도 결핍이며, 따라서 수중의 DO 농도를 일정수준 이상으로 유지시켜 주는 것은 호소 수질관리를 위해 매우 필요하다고 판단된다. 본 연구에서는 공기 중의 산소를 호소 수체에 포기시켜 주는 마이크로버블 발생장치를 J 저수지에 설치하여 수체의 DO 농도 변화 등을 분석하였고, 본 연구결과는 농업용 호소의 수질개선을 위한 기술개발 및 계획수립의 기초자료로 활용하고자 하였다. 마이크로버블 포기장치는 수심이 약 4m 되는 저수지 제방 근처에 100m 간격으로 총 3지점에 설치하였다. 버블 발생기는 기액 2상류 선회형 마이크로 버블 발생장치로 3지점에 각 1set(1set에 3기로 구성)씩 구성하여 저수지 바닥 층에서 상부로 1m 떨어진 지점에 고정식으로 설치하였다. 총 공기흡입량은 380 LPM이며, 사용동력은 12.2kW를 사용하였다. 마이크로 버블 포기장치 설치 후 호 내 DO 농도 변화를 평가하기 위하여 호소 전체에 18개 지점을 선정하여 수심 50cm 간격으로 DO 농도를 측정하였다. 가동 전에는 DO 평균농도가 표층에서는 약 7.7mg/L로 나타났고, 수심에 따라 거의 수직적으로 감소하여 바닥층에서는 약 0.2mg/L로 거의 무산소 상태를 보이고 있었다. 마이크로 버블 가동 2주 후에는 수심 3m까지의 모든 수층에서 DO 농도가 약 6.0mg/L 이상을 보였고, 바닥층에서는 DO 약 3.4mg/의 농도를 나타내었다. 가동 3주 후에도 2주 후와 비슷한 수치를 보이고 있었으나 가동 4주가 지나면서부터는 호소 바닥층(수심 3.5m)에서도 DO 농도가 7.0mg/L 이상의 높은 농도를 유지하는 것으로 조사되었다. 호소 저층에서 호기성 상태의 지속적 유지는 퇴적 오염물질이 수층으로 용출되는 것을 예방할 수 있으므로 마이크로버블을 잘 활용하면 호소의 악취제거 및 수질개선에 많은 도움이 될 것으로 판단된다.

  • PDF