An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger (외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구)

  • Kim, Nae-Hyun;Cho, Honggi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

업무용빌딩 소재 사무실의 실내공기질 평가사례

  • Jeong, Ji-Yeon;Lee, Byeong-Gyu;Lee, Gwang-Yong
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.94-97
    • /
    • 2005
  • 서울, 인천, 광주, 그리고 부산지역의 대형업무용 빌딩 소재 36개 사무실을 대상으로 사무직 근로자의 실내환경에 대한 인식, 신체증상경험, 사무실환경관련 태도를 알기위한 설문조사와 그리고 실내환경에 영향을 미치는 인자에 대한 실태조사결과 자신이 근무하고 있는 사무실 환경에 대해 만족하지 못한 근로자들이 많았으며, 신체이상 증상 경험유무에 있어서도 빌딩증후군 관련 증상을 경험한 사람이 많은 것으로 조사되었다. 실내환경질에 영향을 미치는 요인에 대한 평가에 있어서도 겨울철 경우 실내의 상대습도가 매우 낮아 불편감을 초래하고 있는 것으로 조사되었고, 실내공기 오염의 지표물질인 이산화탄소 농도에 있어서도 최고치 농도가 1,000ppm을 초과하는 사무실이 33.3%인 12개 사무실로 나타나 실내환기에 있어 문제가 있는 것으로 조사되었다. 대부분의 실내공조설비는 주로 온도조절 즉 냉${\cdot}$난방 조절목적으로 주로 이용하고 있는 것으로 나타나 신선외기공급을 통한 실내환기 개념에 있어서는 인식이 낮은 것으로 평가 되었다.

  • PDF

Development of Turboblower for Fuel Cell Automobile Applications (연료전지 자동차용 터보블로어 개발)

  • Kwon Hyuckroul;Park Hyungkeun;Kim Seongkyun;Kim Chimyung;Park Yongsun;Hwang Inchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.345-348
    • /
    • 2005
  • 본 개발의 목적은 연료전지차량에 탑재되는 연료전지 시스템에 장착될 공기공급기를 개발하는 것이었다. 개발된 공기공급기의 형태는 공급해야 할 공기의 유량과 압력 범위, 소음 및 향후 양산성 등을 고려하여 원심형 블로어를 선택하였으며, 차량 부하에 따른 공기공급량을 제어하기 위한 제어기도 적용되었다. 또한 차량에 적용될 경우, 예상되는 가혹한 사용환경에서 안정적인 성능을 발휘하고, 내구성을 할 수 있도록 설계되었으며, 특히, 외기온도 $45^{\circ}C$에서도 충분한 방열성능을 갖도록 모터 및 모터 방열구조를 설계하였다. 이를 위하여 공급되는 공기로 직접 모터를 냉각하는 개념을 적용하였다. 개발된 터보블로어의 응답성을 포함한 성능평가를 수행하였으며, 설계점에서 600시간 연속운전을 통하여 기본 내구평가를 완료하였다.

  • PDF

Effect of Measuring Period on Predicting the Annual Heating Energy Consumption for Building (연간 건물난방 에너지사용량의 예측에 미치는 측정기간의 영향)

  • 조성환;태춘섭;김진호;방기영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.287-293
    • /
    • 2003
  • This study examined the temperature-dependent regression model of energy consumption based on various measuring period. The methodology employed was to construct temperature-dependent linear regression model of daily energy consumption from one day to three months data-sets and to compare the annual heating energy consumption predicted by these models with actual annual heating energy consumption. Heating energy consumption from a building in Daejon was examined experimentally. From the results, predicted value based on one day experimental data can have error over 100%. But predicted value based on one week experimental data showed error over 30%. And predicted value based on over three months experimental data provides accurate prediction within 6% but it will be required very expensive.

A Study on Development of Heat Supply Control Algorithm of Consumer Group Energy Apartment Building by Prediction of Heating Load (집단에너지 공동주택의 사용자 측 열부하 예측에 의한 열공급제어 알고리즘 개발에 관한 연구)

  • Byun, Jae-Ki;Lee, Kyu-Ho;Choi, Young-Don
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1300-1305
    • /
    • 2009
  • The energy conservation in buildings affects environmental preservation as well as economic benefits, and creates the comfortable indoor environment set for the inhabitants. Especially, apartment buildings show ever-increasing energy consumption with large-sized and high-class tendency, thus energy saving counterplans are needed. The present study is to develop an optical control algorithm by using heating load curve according to the outdoor temperature change. Heating load analysis should be performed before the present method can be applied. Dynamic heating load simulations are performed by resistance-capacitance method. Results show that heating load decrease linearly according to the increase of outdoor temperature.

  • PDF

The study for thermal environment improvement at subway station platform (Part 2: Thermal environment according to supply outdoor temperature) (지하역사 승강장 열환경 개선을 위한 연구 (제2보: 도입외기온도에 따른 승강장 열환경))

  • Kim, Hoe-Ryul;Kim, Dong-Gyu;Kum, Jong-Soo;Chung, Yong-Hyun;Kim, Jong-Ryel;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.561-564
    • /
    • 2009
  • This study is to examine the possibility of pre-cooling at platform. Through measurement of the thermal environment of Bujeon Subway platforms, review the potential use of ground-water and night purge. The results of this research can improve the thermal environment pre-cooling of the design.

  • PDF

The Characteristic of Inverter Control by Variation of Refrigeration Load and Outdoor Temperature on Industrial Cooler (외기온도와 부하변화에 따른 산업용 냉각기의 인버터제어 특성)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.150-155
    • /
    • 2014
  • This paper presents The performance analysis of inverter control type-industrial cooler with respect to refrigeration load and outdoor temperature. Aside from materials about simulations and foundation data regarding inverter control compressors, currently, data about commercial coolers with inverter control still lack information for performance comparison. Thus, in this paper, the experiments are done to see characteristics of condensation capacity, evaporation capacity, compressor power and COP with respect to outdoor temperature and load by using a commercial inverter control cooler model. As a result, COP difference of the inverter control cooler with respect to load is 30% at the outdoor temperature of $35^{\circ}C$, 29% at the outdoor temperature of $30^{\circ}C$, 34% at $25^{\circ}C$, respectively.

The Effects of Prediction and Reset Control of Outdoor Air Temperature on Energy Consumption for Central Heating System (외기온도 예측 및 보상제어가 난방시스템의 에너지 소비량에 미치는 영향)

  • Ahn, Byung-Cheon;Hong, Sung-Suk
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.8-14
    • /
    • 2016
  • In this study, the effects of prediction and reset control of outdoor air temperature on energy consumption for central heating system are researched by using TRNSYS program package, and the control performances with the suggested methods of prediction and reset control of outdoor air temperature are compared with the existing ones. As a result, the value of coefficient of determination $R^2$ for the predicted outdoor temperatures is improved and the suggested control method shows maximum 21.8% energy saving in comparison with existing control ones.

고층 아파트의 최적 열공급 시스템

  • 민만기;최영돈
    • Journal of the KSME
    • /
    • v.32 no.3
    • /
    • pp.247-254
    • /
    • 1992
  • 이 글에서는 고충아파트에서 층간 열공급의 불균일성이 발생하는 원인을 설명하였고 이 불균일 성을 해소시키는 새로운 열공급 설비 기술을 설명하였으며 그 내용들에 대한 결론은 다음과 같다. (1) 온수 난방 고층아파트의 층간 열공급의 불균일성은 온수공급관과 회수관의 정수압력의 차 이에 의한 유동저항에 의해서 발생한다. (2) 다구역배관망 시스템은 온수공급관과 회수관의 정수압력의 차이에 의해 발생하는 열공급 불균일성의 해소에 거의 기여하지 못한다. (3) 연속난방방식에서 서모스타트의 설치는 각세대의 열공급을 균일하게 할 수 있고 에너지 절 약면에서 가장 유리한 방식이나 고장의 위험성이 가장 크며, 운전의 미숙에 의한 열공급 제어의 불균일성을 초래하기 쉬우며 외기온도가 매우 낮으면 층간 열공급제어가 되지 않을 수 있어서 자동유량조절밸브를 병용하거나 온수공급압력을 충분히 크게 할 필요가 있다. (4) 자동유량조절밸브에 부착하면 단구역 배관망 시스템에서도 층간의 유량공급의 불균일성을 없앨 수 있으나 순환 펌프유량이 부족하면 밸브의 자동유량조절 기능이 상실된다. (5) 수동유량조절밸브는 TAB에 의해서 충간의 유량을 균일하게 조절할 수 있으나 펌프 성능변화 관부식 등이 발생하면 TAB를 다시 할 필요가 발생할 수 있다. 그러나 밸브의 고장이 적고 유 동저항을 적게 발생시키며 한 개의 밸브로 조절할 수 있는 유량의 범위가 큰 점에서는 가장 유 리하다.

  • PDF

An Experimental Study of Temperature Profiles in Mixing Zone of AHU with an Air Mixer (에어믹서가 설치된 공조기 혼합실 내의 온도분포에 관한 실험적 연구)

  • Pak, Kwon-Jong;Lee, Sek-Jun;Jang, Young-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.999-1006
    • /
    • 2006
  • A study of temperature profiles in mixing zone of AHU (air handling unit) can contribute greatly to enhance performance of AHU system, so the study on the temperature distribution between RA (return air) and OA (outdoor air) is important to analyze the mixing characteristics in a mixing zone of AHU. Accordingly, the temperature profiles during RA (return air) and OA (outdoor air) supply process into mixing zone of AHU with an air mixer are studied experimentally. The effect of air mixer, OA temperature and RA/OA flow rate are studied in detail. In this study, the results show that the mixing efficiency is all high for installed the air mixer. The more OA temperature increase and OA flow rate decrease, the more mixing efficiency is high.