• Title/Summary/Keyword: 완전순환이용

Search Result 109, Processing Time 0.024 seconds

Paleoenvironments in Western Part of the East Sea, Korea, during the Late Quaternary Using Benthic Foraminifera (저서성 유공충에 의한 한국 동해 서부 해역의 제 4기 후반 고해양환경 연구)

  • 우한준;정혜경
    • 한국해양학회지
    • /
    • v.30 no.5
    • /
    • pp.493-511
    • /
    • 1995
  • Analysis of the Late Quaternary benthic foraminifera in the cores from the western part of the East Sea, Korea, indicates several distinct changes in the paleoenvironments during the deposition. The palecology of biofacies of Cores PC-1 from the upper slop and PC-2 from the rise shows several distinct changes in bottom water temperatures during the late Quaternary. The Core PC-4 from the Ulleung Basin generally consists of agglutinated genus, Muiliammina, and anaerobic calcareous genus, Bolivina, in biofacies, suggesting that the anoxic bottom condition was prevailed during the deposition. Benthic foraminiferal rare or barren zones in the Cores indicate the limits of water circulation caused by lower sea-level in the regions during the glacial period through the Late Quaternary. The changes of benthic foraminiferal biofacies reflect temporal and spacial variations in overall bottom environments, such as bottom water temperature, dissolved oxygen, and water circulation pattern. The benthic foraminiferal data can be used to interpret paleoclimatic conditions and predict global sea-level changes, and the results of these studies should be useful to understand the evolutional history of the East Sea through the Late Quaternary.

  • PDF

20-Year Experience of Surgical Treatment for Postpneumonectomy Empyema (전폐절제술 후 사강에 발생한 농흉의 치료)

  • 김형렬;김영태;성숙환;김주현
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.542-547
    • /
    • 2002
  • Background: Postpneumonectomy empyema(PPE) is an infrequent but potentially life-threatening complication. To date, various surgical efforts have been made to manage this complication. We reviewed our 20-year surgical experience of PPE and long-term follow-up data. Material and Method: Total of 37 patients who were treated for PPE between fan, 1980 and Jun, 2000 were included. Various clinical factors such as micro-organism, operative method and timing, presence of bronchopleural fistula(BPF), underlying disease and fate of empyema cavity were retrospectively reviewed and analyzed. Result: Majority of patients(34) underwent Eloesser operation for effective drainage. There was only one operative mortality. The causative organisms were Staphylococcus species and Pseudomonas species in 46% BPF was found in 20 cases, among which spontaneous closures took place in 4 cases. The chest wall was closed in 40%(8/20) of patients with BPF, compared to 59%(10/17) without BPF. The closure rate was statistically better in patients without BPF(p=0.006). Even though the patients with benign disease showed higher closure rate(50%) than those with lung cancer (31%), the difference was not significant(p=0.25). Conclusion: Eloesser procedure was an effective method for initial drainage of PPE cavity with low operative mortality. Given the findings of low spontaneous closure rate of BPF, aggressive approach to close the BPF is mandatory to achieve the final goal of chest wall closure. It was found that majority of patients still left their chest cavity opened, even after controlling the active inflammation of the empyema cavity. More aggnessive approach for chest wall closure is recommended in all patents with benign disease and in selective patients with lung cancer if there is no evidence of recurrence at several years after the initial operation.

Application of Porous Carbon Catalyst Activating Reaction of Positive Electrode in Vanadium Redox Flow Battery (바나듐 레독스 흐름전지의 양극반응 활성화를 위한 다공성 탄소 촉매의 적용)

  • Jeong, Sanghyun;Chun, Seung-Kyu;Lee, Jinwoo;Kwon, Yongchai
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.150-156
    • /
    • 2014
  • In this study, we implemented a research for improving performance of redox flow battery (RFB) via enhancing reaction rate of vanadium reaction ($[VO]^{2+}/[VO_2]^+$) that was a rate determining step. For doing that, porous catalyst, CMK3 was employed and its perfoamance was compared with that of Vulcan(XC-72) and commercial Pt/C (Johnson-Matthey Pt 20wt.%). Cyclic voltammetry (CV) was used for inspecting reactivity, while its structural feature was measured by TEM and BET&BJH. Also, Charge-discharge trend was evaluated by single cell tests. As result, CMK3 showed 6 times better catalytic activity and twice better reversibility than Vulcan(XC-72), while it showed larger surface area than Vulcan XR due to its porous structure. Furthermore, CMK3 indicated 85% of reactivity and reversibility of commercial Pt/C despite its Pt-less situation. In single cell tests, when RFB adopted CMK3 as catalyst for positive electrode, its charge-discharge curve result was better than that adopted commercial Pt/C.

Mixing and Oxygen Transfer Characteristics of Three Phase Fluidized Bed for Water Quality Management of Aquaculture (양어장 수질관리를 위한 삼상유동층 반응기의 혼합 및 산소전달특성)

  • LEE Byung-hun;KIM Jeong-sook;KANG Im-suk
    • Journal of Aquaculture
    • /
    • v.7 no.4
    • /
    • pp.239-249
    • /
    • 1994
  • This study was conducted to elucidate mixing characteristics of the media to dertermine hydraulic model parameters of the three phase fluidized bed for the water quality management of aquaculture. The volume and H/D ratio of the reactor were 1.76 Liter and 10.9, respectively. The experimental results showed that variance $(\sigma^2)$ and dispersion number $(D/{\mu}L)$ were above 0.47 and $0.35\~\infty$, respectively. Therefore, the condition of the reactor was almost ideal complete mixing. The dependence of the overall oxygen-transfer coefficient $(K_{La})$ on each experimental variables through a multple linear regression was given by the following equation ; $$K_{La}\;=\;44.9(D_i/D_c)^{-0.4611}\;A_f^{0.8622}\;C_m^{-0.0746}\;d_p^{-0.4302}$$

  • PDF

Animal Experiments of Heart Transplantation for Complicated Congenital Heart Disease in Neonate (신생아의 복잡심장기형에서 심장이식을 위한 동물실험)

  • 박영환;윤치순;정원석;김명옥;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.504-509
    • /
    • 1999
  • Background: Heart transplantation is considerated for a selected certain group of complicated congenital heart disease in neonates because corrective surgery is very difficult and has high mortality. Precise planning of transplantation is necessary to adequately fit the donor heart to the recipient. Material and Method: We have performed 4 neonatal pig heart transplantations to test the technical feasibility. Experiment 1: The transplantation was performed using the same technique as the adult heart transplantation. Experiment 2: The transplantation for hypoplastic left heart syndrome was simulated as we reconstructed the whole aortic arch with donor aorta. Experiment 3: The heart transplantation was done with radical pulmonary artery reconstruction. Experiment 4: The experiment was performed for a long term survival. Result: Preoperative planning was very important for adequate fitting. All animals could be weaned from cardiopulmonary bypass, however, two animals died due to bleeding at pulmonary artery and left atrium. Conclusion: We concluded that the neonatal heart transplantation can be applied in some complicated Further using animal model is mandatory.

  • PDF

Early Result of Bentall Operation (Bentall 술식의 조기 성적)

  • 송명근
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.113-117
    • /
    • 1998
  • From October 1993 to April 1997, 37 patients(30 male and 7 female patients), ranging in age from 23 to 73 years, were operated for annuloaortic ectasia with or without aortic dissection. Four patients were in New York Heart Association Class I, 10 in Class II, 20 in Class III, and 3 in Class IV. In cases of annuloaortic ectasia with aortic dissection, the surgical treatment in all cases consisted of total replacement of the ascending aorta with composite graft and reimplantation of the coronary arteries to the tube graft. The postoperative complication, as postoperative bleeding or LV dysfunction, was 18%(7 cases) and late mortality for entire group was 2.7%(one death). The period of follow-up ranged from 1 month to 36 months(average 9.6 months). In conclusion, Bentall operation for annuloaortic ectasia with or without aortic dissection is reliable method with low mortality and excellent short-term results.

  • PDF

Dual Stent Application on Congenital Tracheobronchial Stenosis - 1 case - (선천성 기관기관지 협착에서의 이중 스텐트의 적용 - 1례 보고 -)

  • 강문철;황성욱;김용진;김희수;김종성;성명훈
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.149-152
    • /
    • 2002
  • We report successful application of dual trachcobronchial stcnt to the diffuse tracheal stenosis. An one-month-old boy was transferred to the emergency room due to tachypnea and respiratory difficulty with COB retention. Preoperative computed tomography revealed pulmonary artery sling with diffuse tracheal stenosis. We found that the diameter of the both main bronchus was less than 3mm and the trachea was a complete ring. We divided the left pulmonary artery and implanted it to the main pulmonary artery under cardiopulmonary bypass. After that, tracheoplasty was performed with autologous pericardium. However, after the initial measures, CO2 retention and respiratory difficulty persisted due to the granulation tissue and dynamic obstruction of the airway ensued by the overlying pericardial flap. Therefore, we decided to apply a single tracheal stunt. After the insertion of tracheal stent, residual stenosis of the both main bronchus opening continued to cause respiratory difficulty Finally we applied dual tracheobronchial stent and resolved the airway obstruction.

Repair of Left Ventricular Free Wall Rupture after Acute Myocardial Infarction: Application of Pericardial Patch Covering and Fibrin Glue Compression A case report (급성심근경색 후 발생한 좌심실벽 파열에서 소심낭과 Fibrin Glue 압박을 이용한 치험 - 1예 보고 -)

  • 김상익;금동윤;원경준;오상준
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.363-366
    • /
    • 2003
  • Background: Left ventricular rupture after acute myocardial infarction is a serious complication with high mortality. Emergency operation is usually the only available treatment. A 76-year-old female with persistent chest pain and syncopal attacks was admitted. Transthoracic echocardiography showed the pericardial effusion and generalized hypokinesia of the inferolateral wall of left ventricle. Coronary angiography revealed a total occlusion of the first diagonal branch. After percutaneous transluminal coronary angioplasty with coronary stent and insertion of intraaortic balloon pump, emergency operation was performed. Under cardiopulmonary bypass and cardiac arrest with cold blood cardioplegia, coronary artery bypass graft with saphenous vein, pericardial patch covering on the rupture area with 6-0 polypropylene running sutures, and fibrin glue compression under the patch were performed. We present a case of left ventricular (free wall) rupture after acute myocardial infarction.

Design of Recycle Bubble Column Reactor for Continuous Enzymatic Hydrolysis of Cellulose (섬유소의 연속 효소 가수분해를 위한 순환식 기포탑 반응기의 설계)

  • 김춘영;홍석표정봉우이태원
    • KSBB Journal
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1990
  • Enzymatic hydrolysis of insoluble cellulose was performed in a bubble column with tangential flow ulrafiltration membrane unit. The reactor was operated in a batch mode as well as semi-continuous and continuous with continuous removal of products through the tangential flow ultrafiltration membrane. The optimum superficial gas velocity was 1-3cm / sec so as to avoid bubble coalescence and enzyme denaturation. In continuous and selni-cotinuous process, the conversion was gradually increased but the total reduced sugar concentration was drcastically dereased with the dilution rate. It was concluded that the bubble column attaching tangential flow ultrafiltration membrane unit was effective on continuous hydrolysis of cellulose and recovery of enzyme.

  • PDF

Thromboendarterectomy of Chronic Pulmonary Thromboembolism - A Case Report - (만성 폐색전증의 내막 절제술 1례보고)

  • Ban, Dong-Gyu;Kim, Hyuck;Kim, Young-Hak;Kang, Jung-Ho;Chung, Won-Sang;Jee, Heng-Ok;Lee, Chul-Bum;Jeon, Seok-Chol
    • Journal of Chest Surgery
    • /
    • v.34 no.10
    • /
    • pp.792-796
    • /
    • 2001
  • Chronic pulmonary artery thromboembolism is a relatively rare phenomenon causing hypoxia and pulmonary hypertension that eventually leads to respiratory failure and right heart failure. Patients with acute pulmonary artery thromboembolism are generally treated with antithrombotics and thrombolytics. However, in cases with chronic pulmonary artery thromboembolism the fibrinized thrombus is so strongly adhered to the pulmonary artery wall that medical treatment becomes ineffective and surgical treatment must then be considered. We report a 47year old patient, with a history of repeated admission due to unresolved chronic obstructive pulmonary disease and chronic pulmonary artery thromboembolism at a local hospital, who underwent a successful endarterectomy of pulmonary artery thromboemboli using intermittent total circulatory arrest.

  • PDF