• Title/Summary/Keyword: 와 방출

Search Result 616, Processing Time 0.024 seconds

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

Effects of Nodus Nelumbinis Rhizomatis Extracts on Sociopsychological Stress in Mice (연근(蓮根) 추출물이 생쥐의 사회.심리적 스트레스에 미치는 영향)

  • Kim, Su-Yeon;Kim, Eun-Jeong;Lee, Dong-Won;Won, Ho-Young
    • Journal of Oriental Neuropsychiatry
    • /
    • v.15 no.2
    • /
    • pp.149-158
    • /
    • 2004
  • 만성적이거나 반복적인 스트레스는 우울중이나 심신병 등의 발병 기전과 밀접한 관련이 있다. 전기적 자극(electric foot shock), 한랭 자극, 속박(immobilization), 투쟁(fighting), 에테르 노출 등과 같은 심한 스트레스 자극이 뇌 조직의 시상 및 시상하부, 편도체 등에서의 노르아드레날린(noradrenalin) 방출을 유의 하게 감소시키는 동시에 혈청 corticosterone을 증가시키는 것으로 알려져 있다. 한의학에서는 스트레스 인자에 대한 신체반응을 기(氣)의 변화로 인식하고 있고, 이러한 자극요인들은 신체에 대하여 병적 요인을 제공하여 제반 질환을 야기한다. 또한 질병 발생에 대한 근거로 정기(正氣)와 사기(邪氣)의 상호 관계 위주로 인식하는데, 내부의 기(氣)의 변조(變調)는 질병의 발생을 야기하는 기초가 된다. 실험에 사용된 연근(蓮根)은 연꽃과에 속한 수생초본인 연꽃의 뿌리부분으로 우(藕) 또는 우절(藕節)이라는 명칭으로 불리기도 한다. 성미(性味)는 감(甘) 삽(澁) 평(平) 무독(無毒)하고 폐(肺) 위(胃) 간경(肝經)으로 들어가며 수렴지혈(收斂止血) 화어(化瘀)의 효능이 있어 토혈(吐血) 객혈(喀血) 뇨혈(尿血) 편혈(便血) 등의 각종 출혈 증상에 사용되어져 왔다. 최근 연꽃의 부위별 추출물이 흰쥐의 지질 과산화 생성을 효과적으로 억제하는 것으로 보고되고 있어 연근(蓮根)에 대한 다양한 약리 효능의 검색이 필요할 것으로 생각되며 연꽃의 씨앗인 연자육(蓮子肉)이 양심안신(養心安神)의 효능이 있어 스트레스성 질환에 많이 응용되고 있는 것에 착안하여 본 연구를 착수하였다. 실험 동물은 ICR계 마우스를 이용하였으며, 사회 심리적 스트레스는 옆쪽 cage에서 다른 마우스의 신체에 가해지는 전기 충격을 하루 1시간 동안 지켜보게 하는 것으로 유발하였으며 이 상태에서 약물을 투여한 그룹을 실험군, 그렇지 않은 그룹을 대조군으로 하였다. 정상군은 아무런 자극 없이 하루 1시간 동안 일정 공간에 가두어 두는 것으로 하였다. 실험 결과 사회 심리적 스트레스를 받은 경우에 아무런 처치를 하지 않은 대조군에 비해 연근 추출물을 100mg/kg/day 용량으로 5 일간 투여한 실험군에서 혈청 중 corticosterone 함량이 유의하게 감소하였으므로 매우 효과적으로 스트레스를 해소하였음을 알 수 있다. 뇌세포 중에서 신경전달물질로 분비되는 노르아드레날린의 분비량은 전반적으로 증가되는 경향을 나타내었으나 유의성은 없었다. 신체적 또는 사회 심리적 스트레스가 간 조직 내 지질의 과산화를 유발하는 것으로 나타났으며 연근 추출물이 이 결과에는 영향을 주지 못하였다. 사회 심리적 스트레스로 인하여 간 조직 내 지질과산화 정도가 증가하였으므로 혈청 내 ALT 함량도 따라 증가할 것으로 추정되었으며 이에 대한 연근 추출물 경구 투여가 간 조직을 보호할 수 있는지를 확인하기 위해 분리한 혈청으로부터 ALT 함량을 측정한 결과 대조군에 비하여 유의한 감소를 나타내었다. 또한 연근 추출물이 혈청 내 지질 과산화물의 생성을 억제할 수 있다면 질병의 예방과 치료에 효과적일 것으로 추정할 수 있으므로 그 생성량을 측정하여 보았으나 대조군과의 차이가 나타나지 않았다. 이상의 결과들을 종합하여 보면 스트레스가 부하된 5일 동안 연근(蓮根) 추출물을 함께 투여한 결과 혈청 corticosterone 함량을 유의하게 감소시켰고 뇌 조직내 noradrenaline 함량을 증가시키는 경향을 나타내어 스트레스 해소에 도움이 될 수 있음을 시사하였다. 또한 혈청 내 ALT 함량을 유의하게 감소시켜 스트레스로 인해 발생하는 간 기능의 손상도 어느 정도 억제시키는 것을 확인할 수 있었는데 앞으로 연근(蓮根)의 이러한 작용에 대한 보다 자세한 연구들이 필요한 것으로 생각된다.

  • PDF

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

Development of Analytical Methods for Micro Levels of Naphthalene and TNT in Groundwater by HPLC-FLD and MSD (HPLC-FLD와 MSD를 이용한 지하수 중 나프탈렌 및 TNT의 미량 분석법 개발)

  • Park, Jong-Sung;Oh, Je-Ill;Jeong, Sang-Jo;Choi, Yoon-Dae;Her, Nam-Guk
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.35-44
    • /
    • 2009
  • Naphthalene and TNT (2,4,6-trinitrotoluene) are defined by U.S. EPA as possible carcinogenic compounds known to have detrimental effects on the aquatic ecosystem and human body. There are, however, few researches on methods of analyzing micro-levels of naphthalene and TNT dissolved in groundwater. This study introduces and evaluates the newly developed analytical methods of measuring naphthalene and TNT in groundwater by using HPLC-FLD (Fluorescence detector) and MSD (Mass detector). The MDL, LOQ and salt effect of these methods, respectively, are compared with those of conventional methods which use HPLC-UV. For the analysis of naphthalene, HPLC-FLD was set in the maxima wavelength (Ex: 270 nM, Em: 330 nM) obtained from 3D-Fluorescence to be compared with HPLC-UV in 266 nM wavelength. The MDL ($0.3\;{\mu}g/L$) and LOQ ($2.0\;{\mu}g/L$) of naphthalene by using HPLC-FLD were approximately 80 times lower than those analyzed by HPLC-UV (MDL: $23.3\;{\mu}g/L$, LOQ: $163.1\;{\mu}g/L$). HPLC-MSD were used in comparison with HPLC-UV in 230 and 254 nM wavelength for the analysis of TNT. The MDL ($0.13\;{\mu}g/L$) and LOQ ($0.88\;{\mu}g/L$) of TNT analyzed by using HPLC-MSD were approximately 130 times lower than those obtained by using HPLC-UV in 230 nM (MDL: $16.8\;{\mu}g/L$, LOQ: $117.5\;{\mu}g/L$). The chromatogram of TNT analyzed by using HPLC-UV in 230 nM displayed elevated baseline as the concentration of ${NO_3}^-$ increases beyond 21 mg/L, while the analysis using HPLC-MSD did not demonstrate any change in baseline in presence of ${NO_3}^-$ of 63.7 mg/L which is 3.5 times higher than average concentration in groundwater. In conclusion, HPLC-FLD and HPLC-MSD may be used as suitable methods for the analysis of naphthalene and TNT in groundwater and drinking water. These methods can be applied to the monitoring of naphthalene and TNT concentration in groundwater or drinking water.

The evaluation for Clinical usefulness and Safety of Sirolimus-eluting stent and Paclitaxel-Eluting Stents In Patients With Acute Myocardial Infarction (급성심근경색증 환자의 일차적 관동맥 스텐트 삽입술 시 삽입된 Sirolimus-eluting stent 와 Paclitaxel-eluting stent의 임상적 안정성 및 유용성 평가)

  • Min, Gye-Sik;Han, Man-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.5-10
    • /
    • 2012
  • There is a still unsettled issue about the comparison of long-term clinical effects between sirolimus-(SES) and paclitaxel-eluting stents (PES) for the patients with acute myocardial infarction (AMI). Therefore, we performed a retrospective analysis to evaluate the 4-year clinical outcome of SES as compared with PES after percutaneous coronary intervention (PCI) in patients with AMI. From January 2004 to August 2006, all consecutive patients with acute ST-segment elevation myocardial infarction (STEMI) underwent primary PCI and acute NSTEMI underwent PCI by implantation either SES or PES were enrolled. The occurrence of death, cardiac death, recurrent infarction, target vessel revascularization (TVR) and stent thrombosis were analyzed. The composite of major adverse cardiac events (MACE; death, recurrent infarction and TVR) were also analyzed. During the study period, total 668 AMI patients had visited. Of them, total 522 patients (299 with SES and 223 with PES) were enrolled. During 4-year clinical follow-up, there were similar occurrences of death ($18.3{\pm}3.0%$ vs. $14.6{\pm}2.2%$, p=0.26), cardiac death ($11.2{\pm}2.6%$ vs. $6.8{\pm}1.52%$, p=0.39), re-infarction ($6.4{\pm}1.8%$ vs. $3.3{\pm}1.1%$, p=0.31), and stent thrombosis ($5.4{\pm}1.7%$ vs. $3.2{\pm}1.1%$, p=0.53) between the two groups, consecutively. The occurrences of TVR ($10.0{\pm}3.0%$ vs. $4.0{\pm}1.2%$, p=0.008) and MACE ($29.4{\pm}3.5%$ vs. $19.4{\pm}2.5%$, p=0.003) were significantly higher in patients treated with PES than SES. In AMI patients treated with either SES or PES implantation, SES had a significantly lower risk of TVR and MACE during 4-year clinical follow-up. Rates of death, cardiac death or recurrent infarction, and stent thrombosis were similar.

Improved Activity Estimation using Combined Scatter and Attenuation Correction in SPECT (단일광자방출단층촬영 영상에서 산란 및 감쇠 보정에 위한 절대방사능 측정)

  • Lee, Jeong-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.382-390
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the accuracy of radioactivity quantitation in Tc-99m SPECT by using combined scatter and attenuation correction. Materials and Methods: A cylindrical phantom which simulates tumors (T) and normal tissue (B) was filled with varying activity ratios of Tc-99m. We acquired emission scans of the phantom using a three-headed SPECT system (Trionix, Inc.) with two energy windows (photopeak window: $126{\sim}154keV$ and scatter window: $101{\sim}123keV$). We performed the scatter correction with dual-energy window subtraction method (k=0.4) and Chang attenuation correction. Three sets of SPECT images were reconstructed using combined scatter and attenuation correction (SC+AC), attenuation correction (AC) and without any correction (NONE). We compared T/B ratio, image contrast [(T-B)/(T+B)] and absolute radioactivity with true values. Results: SC+AC images had the highest mean values of T/B ratios. Image contrast was 0.92 in SC+AC, which was close to the true value of 1, and higher than AC (0.77) or NONE (0.80). Errors of true activity by SPECT images ranged from 1 to 11% for SC+AC, $22{\sim}47%$ for AC, and $2{\sim}16%$ for NONE in a phantom which was located 2.4cm from the phantom surface. In a phantom located 10.0cm from the surface, SC+AC underestimated by 24%, NONE 40%. However, AC overestimated by 10%. Conclusion: We conclude that accurate SPECT activity quantitation of Tc-99m distribution can be achieved by dual window scatter correction combind with attenuation correction.

  • PDF

Mineralogical Studies of the Tourmaline for Medicinal Applications by Production Localities (본초 광물로서의 활용을 위한 산지별 전기석의 광물학적 연구)

  • Jie, Yan;Kim, Seon-ok;Park, Hee Yul;Park, Maeng-Eon
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.345-358
    • /
    • 2018
  • In this study, we have performed electron probe micro analyzer (EPMA), X-ray differaction (XRD), inductively coupled plasma spectroscopy (ICP), Fourier transform Raman spectroscopy (FT-Raman), far-infrared (FIR), nuclear magnetic resonance (NMR), and pH-DO Analyses for characterizing medicinal mineralogy aspect of the black tourmaline (Shantung, china), black and pink tourmaline (Minas Geraris, Brazil), black touemaline (Daeyu mine, Korea). In addition, heating effects of the tourmaline sauna as well as the effects of tourmaline powder-added soap on skin troubles have been investigated. It has been revealed that chemical composition of the tourmaline is either high in Fe-, Al-, B-rich types. Ratio of the K-Ca, Na-K, and Fe-B reflects the component change property of solid solution. $CaO/CaO+Na_2O$ and MgO/FeO+MgO ratio show high positive correlation. When tourmaline reacts with distilled water, extended reaction time DO values approximately decrease and it stabilizes at DO = 10. Otherwise, pH values increase until 6 hours and it stabilizes at pH = 8 after 24 hours. Distilled water changes to alkaline when it reacts with tourmaline powder and particles. Tourmaline showed lower absorption spectrum strength and transmittance at short wave, where absorption spectrum wavelength and strength were determined by the content of the composition elements and characteristics of crystallography. Increase of the Fe content has been confirmed to be the cause for the reduction of irradiation. For the chemical composition and spectral property of the tourmaline particle samples, it has been found that Si and Fe contents show positive correlation with Far-Infrared irradiation, while Al and Mg contents show negative correlation. For tourmaline powder, it has been confirmed that $^{17}O-NMR$ FWHM (full width at half maximum) decreases when reacts with distilled water. Tourmaline sauna (approximately $100^{\circ}C$) was found to increase $0.5-1.5^{\circ}C$ of body temperature, average of 12 heartbeat, and 10mg Hg of blood pressure. Tourmaline soap had very good aesthetic effect to skin and was confirmed to have above the average improvements to skin troubles (e.g., allergy or atopy).

THE EFFECTS OF VARIOUS CURING LIGHT SOURCES ON THE MICROHARDNESS OF LIGHT-ACTIVATED RESTORATIVE MATERIALS (다양한 광원에 의한 광중합형 수복물질의 미세경도에 관한 연구)

  • Choi, Nam-Ki;Yang, Kyu-HO;Kim, Seon-Mi;Choi, Choong-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.634-643
    • /
    • 2005
  • The aim of this study is to evaluate the effects of blue light emitting diode (LED) Light Curing Units (FreeLight 2, L.E.Demetron I, Ultra-Lume 5) on the microhardness of three resin composites (Z250, Point 4, Dyract AP) and to determine their optimal curing time. Samples were made using acrylic molds $(2.0mm{\times}3mm)$ of each composite. All samples were prepared over a Mylar strip placed on a flat glass surface. After composite placement on the molds, the top surface was covered with another Mylar strip and a glass slab was gently pressed over it. The times of irradiation were as follows: Elipar TriLight, 40 s; Elipar FreeLight 2. L.E.Demetron I, and Ultra-Lume 5, 10s, 20s, 40s, respectively. Mean hardness values were calculated at the top and bottom for each group. ANOVA and Sheffe's test were used to evaluate the statistical significance of the results. Results showed that FreeLight 2, Ultra-Lume 5, and L.E.Demetron I were able to polymerize point 4 in 20 seconds to a degree equal to that of the halogen control at 40 seconds. FreeLight 2 and L.E.Demetron I were able to polymerize Z250 in 10 seconds to a degree equal to that of the halogen control at 20 seconds. FreeLight 2 and L.E.Demetron I were able to polymerize Dyract AP in 10 seconds to a degree equal to that of the halogen control at 40 seconds. The commercially available LED curing lights used in this study showed an adequate microhardness with less than half of the exposure time of a halogen curing unit.

  • PDF

WEAR AND CHEMICAL DEGRADATION OF ESTHETIC RESTORATIVE MATERIALS (심미수복 재료의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Hun-Ju;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.190-201
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four esthetic restorative materials in an alkaline solution. The brands studied were Charmfil, Charmfil flow(composite resin), Compoglass F and PrimaFlow(compomer). The results were as follows: 1. The mass loss were not significantly different among the materials(p>0.05). 2. The sequence of the degree of degradation layer depth was in descending order by Compoglass F, PrimaFlow, Charmfil, and Charmfil flow. There were significant differences between Compoglass F and the others(p<0.05). 3. The sequence of the Si loss was in descending order by Charmfil flow, Charmfil, PrimaFlow, and Compoglass F. There were significant differences among these materials(p<0.05). 4. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. 5. The sequence of maximum wear depth was in descending order by Comfoglass, PrimaFlow Charmal, and Charmfil flow. There were significant differences among these materials(p<0.05). 6. The correlation coefficient between Si loss and degradation layer depth (r=0.602, p<0.05) Vicker's hardness number and maximum wear depth (r=0.501, p<0.05) were relatively high. These results indicate that wear and hydrolytic degradation may be considered to be evaluation factors of composite resins and compomers.

  • PDF