• Title/Summary/Keyword: 온도헌팅

Search Result 4, Processing Time 0.021 seconds

Temperature Control Improvement of Pressure Heating Roller for Flexible Flat Cable Production (Flexible Flat Cable 생산성 향상을 위한 가압용 히팅롤러의 온도제어개선)

  • Kim Jae Hak;Lee Ho Jung;Chun Keyoung Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.155-163
    • /
    • 2005
  • Pressure heating rollers with temperature control were mounted to a flat cable laminating machine (FCLM). Pressure heating rollers should be heated up to the setting temperature $(175^{\circ}C)$ and kept on to producing good quality flexible flat cables (FFC). Existing Pressure heating rollers took more than 70minutes to the setting temperature and did not keep on the setting temperature in production. Temperature controller, electric power controller, material and diameter of rollers and heat capacities were changed to improve the temperature control of the pressure heat rollers for better production of the FFC. Thus, the reaching time to the setting temperature (RT), temperature stability time (TST) and temperature hunting (TH) were measured and compared with the existing pressure rollers case. The RT of A roller was shortened by 50minutes, and B roller was shortened by 15minutes. The TST of A roller was shortened by 13minutes, and B roller was shortened by 15minutes. The THs of both A and B rollers were settled up to ${\pm}5^{\circ}C$. Finally, the productivity of the FCLM and the quality of the FFC were increased.

A New Temperature Control System by PWM Control Method for Thermal Massage System (PWM 제어방식에 의한 온열치료기의 새로운 온도제어 시스템)

  • Song, Myoung-Gyu;Lee, Jae-Heung
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.409-419
    • /
    • 2014
  • This paper proposes a new temperature control algorithm and system configuration of the pTMS(personal Thermal Massage System). By controlling the pulse width of the PWM(Pulse Width Modulation), the temparature of the heating lamp can be controlled stably, which is indispensable to the massage function. This technology is also adapted to the 'thermal massage', 'thermal acupressure', 'thermal moxibustion' functions of medical equipments. The temperature could be set at between $40^{\circ}C{\sim}70^{\circ}C$ by increments of $5^{\circ}C$, the control could be made in real time by increments of $1^{\circ}C$, and the temperature is displayed on the monitor by triggering every 2 seconds. when the present temperature is equal to the preset temperature, the PWM signal is minimized, and when the present temperature is higher than the preset temperature, overheating is prevented by interrupting the PWM output signal. When the difference of temperature exceeds $4^{\circ}C$, the PWM control is maximized in order for the system to reach the target temperature within a short period of time.

A Study on Dynamic Characteristics of a Refrigeration System by Controlling the Evaporator Superheat (증발기 과열도제어에 따른 냉동장치의 동특성에 관한 연구)

  • 김재돌;오후규;윤정인
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.2012-2021
    • /
    • 1995
  • An experimental study was performed for the analysis of dynamic characteristics of refrigeration system by controlling the evaporator superheat. Experimental data have been taken utilizing two different devices, thermostatic expansion valve(T.E.V.) and electronic expansion valve(E.E.V.), for the control of the evaporator superheat. The ranges of parameters, such as superheat, mass flow rate of refrigerant and inlet temperature of evaporator were 5-30.deg. C 90-170 kg/h and 10-25.deg. C, respectively. The data taken from the T.E.v.and E.E.v.were discussed with the control of the superheat, pressure drop, refrigerating capacity, compression work, evaporating temperature, condensing temperature and COP affecting performance characteristics of refrigeration system. In case of the refrigerant flow control with T.E..V., the superheat and pressure drop of the evaporator varied periodically, but the control with E.E.V., the parameters were very stable. In E.E.v.control, refrigerating capacity, compression work and evaporating temperature were decreased with increasing superheat, and the highest COP was obtained in the range of superheat from 5.deg. C to 15.deg. C.

Study on Control of Refrigerant Flow Rate and Characteristics of Superheat in Evaporator using Electronic Expansion Valve (전자(電子) 팽창밸브를 이용(利用)한 증발기(蒸發器)의 냉매(冷媒) 流量(유량) 제어(制御) 및 과열도(過熱度) 특성(特性)에 관한 연구(硏究))

  • Choi, S.O.;Kim, J.H.;Yang, H.S.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.380-387
    • /
    • 1994
  • An experimental study was performed to investigate the characteristics of refrigerant flow rate control and superheat in an evaporator with an electronic expansion valve(EEV). The EEV used in this study was devised using a needle valve coupled with a stepping motor controlled by a personal computer. A Pill control equation was used to control the superheat of the evaporator and to set the superheat to $5^{\circ}C$. In order to determine an optimum running condition for the system, Pill parameters were varied for the wide range of values. The running condition of an air conditioning system with a PI control was reasonably stable compared with that of the Pill control. Experimental results for the PI control using parameter values, $K_p=1.5$, $T_i=400(sec)$ and $T_s=6(sec)$ show that the superheat reached its target value. When external disturbances were introduced to the system, the superheat target value was reached within about 3 minutes. When the EEV was applied to the air conditioning system driven by an inverter, room temperature control was excellent.

  • PDF