• 제목/요약/키워드: 온도헌팅

검색결과 4건 처리시간 0.017초

Flexible Flat Cable 생산성 향상을 위한 가압용 히팅롤러의 온도제어개선 (Temperature Control Improvement of Pressure Heating Roller for Flexible Flat Cable Production)

  • 김재학;이호중;전경진
    • 한국정밀공학회지
    • /
    • 제22권7호
    • /
    • pp.155-163
    • /
    • 2005
  • Pressure heating rollers with temperature control were mounted to a flat cable laminating machine (FCLM). Pressure heating rollers should be heated up to the setting temperature $(175^{\circ}C)$ and kept on to producing good quality flexible flat cables (FFC). Existing Pressure heating rollers took more than 70minutes to the setting temperature and did not keep on the setting temperature in production. Temperature controller, electric power controller, material and diameter of rollers and heat capacities were changed to improve the temperature control of the pressure heat rollers for better production of the FFC. Thus, the reaching time to the setting temperature (RT), temperature stability time (TST) and temperature hunting (TH) were measured and compared with the existing pressure rollers case. The RT of A roller was shortened by 50minutes, and B roller was shortened by 15minutes. The TST of A roller was shortened by 13minutes, and B roller was shortened by 15minutes. The THs of both A and B rollers were settled up to ${\pm}5^{\circ}C$. Finally, the productivity of the FCLM and the quality of the FFC were increased.

PWM 제어방식에 의한 온열치료기의 새로운 온도제어 시스템 (A New Temperature Control System by PWM Control Method for Thermal Massage System)

  • 송명규;이재흥
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.409-419
    • /
    • 2014
  • 본 논문에서는 온열치료기의 온도제어 알고리즘 및 시스템을 구현하였다. PWM(Pulse Width Modulation) 파형의 온 타임 펄스폭을 제어함으로서 온열치료기의 마사지 기능에 적합한 온열요법이 내장된 안정된 온도제어를 구현 할 수 있었으며 의료기기의 온열마사지, 온열지압, 온열 뜸 기능에 적용 하였다. 온도설정 범위는 $40^{\circ}C$에서 $70^{\circ}C$까지이며 $5^{\circ}C$ 단위로 설정하였고 제어량은 실시간으로 $1^{\circ}C$ 단위로 제어하였으며 $1^{\circ}C$ 간격으로 온도를 표시하였다. 제어범위는 설정온도와 현재온도의 차가 $4^{\circ}C$이하부터 4단계로 PWM 펄스폭을 가변하여 램프의 출력을 제어하였다. 현재온도가 설정온도와 같을 경우 PWM 신호를 최소로 하였고 현재온도가 설정온도 보다 클 경우는 PWM 출력 신호를 정지시켜 오버헌팅을 방지했으며 연산차가 $4^{\circ}C$이상인 경우 PWM 제어량을 최대폭으로 하여 시스템을 빠른 상승시간 안에 목표치에 도달할 수 있도록 제어하는 방식으로 구현하였다.

증발기 과열도제어에 따른 냉동장치의 동특성에 관한 연구 (A Study on Dynamic Characteristics of a Refrigeration System by Controlling the Evaporator Superheat)

  • 김재돌;오후규;윤정인
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.2012-2021
    • /
    • 1995
  • An experimental study was performed for the analysis of dynamic characteristics of refrigeration system by controlling the evaporator superheat. Experimental data have been taken utilizing two different devices, thermostatic expansion valve(T.E.V.) and electronic expansion valve(E.E.V.), for the control of the evaporator superheat. The ranges of parameters, such as superheat, mass flow rate of refrigerant and inlet temperature of evaporator were 5-30.deg. C 90-170 kg/h and 10-25.deg. C, respectively. The data taken from the T.E.v.and E.E.v.were discussed with the control of the superheat, pressure drop, refrigerating capacity, compression work, evaporating temperature, condensing temperature and COP affecting performance characteristics of refrigeration system. In case of the refrigerant flow control with T.E..V., the superheat and pressure drop of the evaporator varied periodically, but the control with E.E.V., the parameters were very stable. In E.E.v.control, refrigerating capacity, compression work and evaporating temperature were decreased with increasing superheat, and the highest COP was obtained in the range of superheat from 5.deg. C to 15.deg. C.

전자(電子) 팽창밸브를 이용(利用)한 증발기(蒸發器)의 냉매(冷媒) 流量(유량) 제어(制御) 및 과열도(過熱度) 특성(特性)에 관한 연구(硏究) (Study on Control of Refrigerant Flow Rate and Characteristics of Superheat in Evaporator using Electronic Expansion Valve)

  • 최순오;김정훈;양현석;김종수
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.380-387
    • /
    • 1994
  • An experimental study was performed to investigate the characteristics of refrigerant flow rate control and superheat in an evaporator with an electronic expansion valve(EEV). The EEV used in this study was devised using a needle valve coupled with a stepping motor controlled by a personal computer. A Pill control equation was used to control the superheat of the evaporator and to set the superheat to $5^{\circ}C$. In order to determine an optimum running condition for the system, Pill parameters were varied for the wide range of values. The running condition of an air conditioning system with a PI control was reasonably stable compared with that of the Pill control. Experimental results for the PI control using parameter values, $K_p=1.5$, $T_i=400(sec)$ and $T_s=6(sec)$ show that the superheat reached its target value. When external disturbances were introduced to the system, the superheat target value was reached within about 3 minutes. When the EEV was applied to the air conditioning system driven by an inverter, room temperature control was excellent.