• Title/Summary/Keyword: 온도항상성

Search Result 60, Processing Time 0.031 seconds

Experimental Study for Thermal Characteristics of Frozen Soil Samples (동토 시료의 열적 특성 분석을 위한 실험적 연구)

  • Sewon, Kim;Sangyeong, Park;Jongmuk, Won;YoungSeok, Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.4
    • /
    • pp.31-40
    • /
    • 2022
  • Recently, the Arctic resource development project, where undeveloped energy resources (oil, natural gas, etc.) are deposited, is actively being promoted for the perspective of diversifying the construction market and developing future energy resources. However, the frozen ground always has problems such as sinking and frost-heaving due to extreme weather. Therefore, it is necessary to analyze the thermal characteristics of the frozen soil to secure the stability of the ground structure. In this study, a series of laboratory tests were performed to evaluated the thermal characteristics of frozen soil samples in the oil sand field in Alberta, Canada. In additon, it was compared with the results of domestic(Gangwond-do) sample performed under the same conditions. As a comparison results of the experiments, it was clarified that the different frozen water content and thermal conductivity characteristics by temperature after completion of freezing could affect the frozen soil behavior.

The Effect of Na+-Ca2+ Ion-exchange for Heulandite on the Thermal Stability (Na+-Ca2+ 양이온 교환이 Heulandite의 열적 안정성에 미치는 영향)

  • Kim, Wha-Jung;Lee, Jae-Ik
    • Applied Chemistry for Engineering
    • /
    • v.4 no.3
    • /
    • pp.488-496
    • /
    • 1993
  • Natural zeolites have recently been the subject of intensive research due to their versatilities in possible industrial applications. Among several different types of domestic natural zeolites, clinoptilolite, is one of the highly prospective domestic natural zeolites. However, it is always possible for heulandite, the isostructure of clinoptilolite, to coexist with clinoptilolite. Unfortunately, heulandite is thermally very unstable restricting its application to industrial process. In this paper, the effects of ion exchanges and heat-treatments on the thermal stability for domestic natural zeolite, heulandite are described. Two different ion-exchanging experiments were carried out followed by heat-treatments at different temperatures. X-ray, IR and AA spectroscopic analyses showed the enhancements in thermal stabilities of heulandite by $Na^+$ cation exchanges.

  • PDF

End Point Temperature of Rewarming and Afterdrop After Hypothermic Cardiopulmonary Bypass in Pediatric Patients (소아에서의 저체온 심폐바이패스후 재가온 종료온도와 후하강)

  • Kim, Won-Gon;Lee, Hae-Won;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.125-130
    • /
    • 1997
  • Separating the patient from hypothermic cardiopulmonary bypass(CPB) before achieving adequate rewarming often results in afterdrop, which can predispose to electrolyte disturbances, arrhythmia, hemodynamic alterations, and shivering-induced increase of oxygen consumption. In an attempt to find an adequate end point temperature of rewarming after hypothermic CPB, 50 pediatric cardiac surgical patients were r ndomly assigned for end point temperature of rewarming of 35.5$^{\circ}C$ (Group 1) or 37t (Group 2), rectal temperature. Thereafter the rectal temperature was measured half, one, four, eight, and 16 hour after arrival to the intensive care unit(ICU), with heart rate and blood pressure. Additionally the rectal temperature was compared with esophageal temperature during CPB, and axillary temperature luring stay in the ICU. Nonpulsatile perfusion with a roller pump was used in all patients and a membrane or bubble oxygenator was used for oxygenation. Both groups were comparable with respect to age, sex, body surface area, total bypass time, and rewarming time. There was no afterdrop in both groups, and there were no statistical differences in the rectal temperatures between two groups. There were also no statistical dilyerences with respect to the heart rate and blood pressure between two groups. At the end of rewarming the esophageal temperature was higher than the rectal temperature. The axil ary temperature measured in ICU was always lower than the rectal temperature. No shivering was noted in all patients. In conclusion, with restoration of rectal temperature above 35.5$^{\circ}C$ at the end of CPB in pediatric patients, we did not observe an afterdrop.

  • PDF

Enhancement of the Life of Refractories through the Operational Experience of Plasma Torch Melter (플라즈마토치 용융로 운전경험을 통한 내화물 수명 증진 방안)

  • Moon, Young Pyo;Choi, Jang Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.2
    • /
    • pp.169-178
    • /
    • 2016
  • The properties of wastes for melting need to be considered to minimize the maintenance of refractory and to discharge the molten slags smoothly from a plasma torch melter. When the nonflammable wastes from nuclear facilities such as concrete debris, glass, sand, etc., are melted, they become acid slags with low basicity since the chemical composition has much more acid oxides than basic oxides. A molten slag does not have good characteristics of discharge and is mainly responsible for the refractory erosion due to its low liquidity. In case of a stationary plasma torch melter with a slant tapping port on the wall, a fixed amount of molten slags remains inside of tapping hole as well as the melter inside after tapping out. Nonmetallic slags keep the temperature higher than melting point of metal because metallic slags located on the bottom of melter by specific gravity difference are simultaneously melted when dual mode plasma torch operates in transferred mode. In order to minimize the refractory erosion, the compatible refractories are selected considering the temperature inside the melter and the melting behavior of slags whether to contact or noncontact with molten slags. An acidic refractory shall not be installed in adjacent to a basic refractory for the resistibility against corrosion.

Design of automatic Equalizer using Feedback and Feedforward (궤환과 순방향 공급경로를 이용한 자동조절 능동가변 등화기의 설계)

  • 이상영;박종국
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.8 no.3
    • /
    • pp.96-104
    • /
    • 1983
  • In wire transmission systems using a coaxial cable or cable pair, the cable loss caused by the transmission characteristic of the cable varies depending on the length of the cables or variation in the ambient temperature, and usually takes the form close to a $\sqrt f$ characteristic. In order to compensiate for such loss, an actove variable automatic equalizer with a tandam combination of feedback and feedforward was presented. The automatic equalizer to be described here overcomes many of the disadbantages associated with the conventional passive variable equalizers, which include the need for inducters, a complex design procedure, and incompatibility with modern dldctronic control systems that are very complicated. This design has advanatges over other active variable equalizer design and it is especially applicable to precision equalization at frequencies bellow 1MHz.

  • PDF

Study on hydrologic variability of Soyang dam associated with tropical cyclones effects (태풍 영향을 고려한 소양강댐의 수문 변동특성에 관한 연구)

  • Kang, Ho Yeong;Hwang, Sung Hwan;Choi, Ji Hyeok;Moon, Young Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.456-456
    • /
    • 2017
  • 지구온난화에 의한 태풍강도 증가로 한반도지역은 잠재적 위험성에 항상 노출되어있다. 따라서 본 연구는 한강의 대표적 다목적댐인 소양강댐을 대상으로 한반도 태풍영향을 정량화하고 그에 따른 수문변화특성을 피어슨 상관분석(Pearson Correlation)과 순위 분석(Rank Analysis)을 이용하여 조사하였다. 지오포텐셜 고도자료와 GPCP 강우자료를 분석한 결과 소양강댐의 여름철 유출량 중 태풍에 의한 유출이 크지 않았지만 엘리뇨에서 라니냐로 전환되는 시기의 태풍에 의한 유출량은 반 이상을 차지할 정도로 크게 나타났다. Rank분석결과 태풍발생비율(n/N)에 대한 첨두유량의 변화는 크지만 첨두유량의 발생빈도와 지속시간의 변화는 뚜렷하지 않은 것으로 나타났고 첨두발생시간은 더 지연되는 특성을 보였다. 그러나 High Flow 분석결과에서는 첨두유량과 첨두유량의 발생시기 변화의 통계적 유의성은 나타나지 않았으나 첨두유량 이상의 유출발생빈도와 지속기간은 증가하는 것으로 나타났다. 본 연구는 해수면 온도 변화에 따른 대규모 대기 순환패턴과 소양강댐 유역의 수문변화특성의 관계를 파악하기 위한 기초자료를 제공할 것으로 기대된다.

  • PDF

Implementation of Physical Unclonable Function(PUF) using Transmission Line Crosstalks (전송선의 크로스토크를 이용한 물리적복제방지기능(PUF) 구현)

  • Lee, Kwan-Hee;Kim, Seung-Youl;Cho, Kyoungrok;You, Younggap
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.75-82
    • /
    • 2013
  • This paper presents a PUF circuit based on the randomness of crosstalk magnitudes in adjacent transmission lines. Conventional PUF circuitry suffers the reliability problem where a consistent output value is not guaranteed due to environmental changes, such as power supply voltage and operating temperature. The proposed circuit consists of three transmission lines. The crosstalk difference between two transmission line pairs can be arbitrary. The proposed circuit compares the crosstalk differences between two transmission line pairs, and yields consistent responses. The crosstalk differences are immune to operating environment changes. The proposed PUF circuit provides with reliable responses for given challenges. It can be utilized by security systems such as authentication and encryption.

생물공정의 측정 및 새로운 공정변수의 개발

  • Heo, Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.51-52
    • /
    • 2000
  • 생물공정의 운전에 있어서 적절한 공정변수가 부족한 경우가 많다. 이것은 멸균과정을 견딜 수 있는 신뢰성 높은 센서가 부족하기 때문이다[1]. 생물공정에 주로 사용되는 센서로서는 온도, pH, D.O., rpm, viscosoty 등이 있으나 이 센서들은 배양액의 물리적 혹은 화학적 상태를 측정할 수 있는 경우가 대부분이다[2]. 미생물의 대사활동과 관련이 있는 공정 변수로는 배출가스의 성분을 측정하여 얻을 수 있는 Oxygen uptake rate, Carbon dioxide evolution rate 및 Respiratory quotient가 있으며 현재 생물공정의 운전에 사용되고 있다[3]. 그러나 반복적인 센서의 보정과 연결관의 잦은 청소 및 보수를 필요로 하여 제한적으로 사용되고있는 실정이다. 자동화된 습식분석장치, Gas chromatograph, High Performace Liquid Chromatograph 혹은 Mass spectrophtometry 등을 온라인 샘플 처리장치와 연결하여 발효조의 배양액의 성분을 온라인으로 분석하고 공정의 운전에 응용하는 사례가 많이 발표되었다[4-6]. 고가의 장비 및 운전의 번거러움이나 추가적인 인력이 필요하므로 역시 특별한 경우에만 사용되고 있다. 이외에도 여러 종류의 온라인 센서 및 바이오 센서등이 개발되어 사용되고 있으나 역시 그 사용범위는 특수한 영역에 한정되어있다. 이와 같이 새로운 센서를 개발하여 공정변수를 측정하려는 시도중의 하나가 소프트웨어 센서의 개발이다. 이 것은 공정상에서 발생하는 1차 공정변수를 이용하여 배양액의 상태 혹은 2차적인 공정 변수를 추측해내는 것이다. 대부분의 경우 기존의 공정 변수를 사용하므로 추가적인 비용이 들지 않고 소프트웨어의 형태로 구현되므로 센서의 보정과 설치 및 유지관리의 노력이 매우 적은 장점이 있다. 본 연구에서는 생물공정에서 자동제어 과정에서 발생하는 여러 가지 공정상의 제어 신호로부터 새로운 공정 변수를 얻어내고자 시도하였다. 대부분의 생물공정에서는 pH의 자동제어가 필수적인데 자동제어 과정에서 발생하는 pH 제어 신호 및 pH의 변화 응답신호를 이용하여 배지의 완충용량의 변화와 알칼리의 소비속도를 온라인으로 측정할 수 있었다. 여기에 인공지능망을 설계하여 균체의 량을 온라인으로 추정하는 방법을 개발하였다 [7].산업용 발효조의 운전 온도는 주로 냉각수의 단속적인 공급에 의하여 항상 일정하게 조절된다. 따라서 냉각수의 냉각량을 측정하면 미생물의 배양시 발생하는 대사열량을 측정할 수 있게 된다. 본 연구에서는 실험실의 발효조를 냉각수의 단속적인 공급에 의하여 자동온도 조절이 되도록 개조하고 여기에 냉각수의 유출입 지점에 온도센서를 부착하여 냉각수의 온도를 측정하고 냉각수의 공급량과 대기의 온도 등을 측정하여 대사열의 발생을 추정할 수 있었다. 동시에 이를 이용하여 유가배양시 기질을 공급하는 공정변수로 사용하였다 [8]. 생물학적인 폐수처리장치인 활성 슬러지법에서 미생물의 활성을 측정하는 방법은 아직 그다지 개발되어있지 않다. 본 연구에서는 슬러지의 주 구성원이 미생물인 점에 착안하여 침전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.

  • PDF

Changes in Quality Characteristics of 'Setoka' (Citrus spp.) Using Different Storage Methods (저장방법에 따른 '세토카' 감귤의 품질변화)

  • Lee, Ji-Hyun;An, Hyun-Joo;Lee, Sun-Yi;Choi, Young-Hun;Lim, Byoung-Seon;Kang, Yeung-Joo
    • Food Science and Preservation
    • /
    • v.16 no.5
    • /
    • pp.644-649
    • /
    • 2009
  • We investigated quality changes in Setoka ([Citrus unshiu$\times$Citrus sinensis]$\times$Citrus reticulate]$\times$[Citrus reticulata$\times$Citrus sinensis]) wrapped in 30-m pore size low-density polyethylene film (LDPE) and stored at different temperatures. LDPE wrapping effectively inhibited weight loss, and fruits seemed fresh even after room temperature storage. The decay rate was higher at room temperature and with LDPE wrapping. The respiration rate of LDPE- wrapped fruits was somewhat higher than that of control samples. Thus, no modified atmosphere packaging (MAP) effect was observed when 'Setoka' citrus was studied. Acidity decreased at a constant but different rate with each storage method used, and these rates were correlated with respiration rates. Soluble solid content (SSC), however, increased during 45 days of storage a subsequent rapid decrease was then observed.

Explosion Hazard Assessment of Pharmaceutical Raw Materials Powders (원료의약품 분진의 폭발 위험성 평가)

  • Lee, Joo Yeob;Lee, Keun Won;Park, Sang Yong;Han, In Soo
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.600-608
    • /
    • 2017
  • Hazard risk of explosion on pharmaceutical raw materials dust in pharmaceutical industry often exists when it is handled or processed in the industrial sites, and explosion accident is caused by this. In this study, the dust explosion characteristics of the three pharmaceutical raw materials samples were measured. The main explosion characteristics are as follows: $P_{max}$, MIE and MIT of loxoprofen acid having $5.31^{\circ}C$ of median diameter are obtained 8.4 bar, 1 mJ < MIE < 3 mJ and $550^{\circ}C$. $P_{max}$, MIE and MIT of camphorsulfonate having $95.63^{\circ}C$ of median diameter are obtained 7.9 bar, 30 mJ < MIE < 100 mJ and $510^{\circ}C$. $P_{max}$, MIE and MIT of rifampicine having $26.48^{\circ}C$ of median diameter are obtained 7.9 bar and 1 mJ < MIE < 3 mJ and $470^{\circ}C$. The deflagration index ($K_{st}$) and the explosion index (EI) were obtained by using these data. The explosion hazard assessment of pharmaceutical raw materials dust was compared and examined. As a result, the explosion hazard assessment according to deflagration index and explosion index were the explosion class with St 2 and the explosion hazard rating of severe for loxoprofen acid & rifampicine and St 1 and strong for clopidogrel camphorsulfonate, respectively.