• Title/Summary/Keyword: 온도차 에너지

Search Result 563, Processing Time 0.027 seconds

An Experimental Study on the Thermal Characteristics of Ice Storage Tank - Focusing on the Adiabatic Effects of Ice Storage Tank - (직접접촉식 빙축열조의 전열특성에 관한 연구 - 빙축열조의 단열영향을 중심으로 -)

  • Lee, Chae-Moon;Park, Jung-Won;Cho, Nam-Chul;Park, Sang-Rok;Kim, Il-Gyoum;Kim, Dong-Chun;Kim, Young-Ki;Yim, Chang-Soon
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.75-89
    • /
    • 1997
  • In this paper, the operating thermal characterictics of liquid-ice was expeimentally investigated in an adiabatic and a non-adiabatic direct contact liquid-ice heat exchanger. Experiments were carried out varing inlet temperature, Ice Packing Factor, and the flow rate of heat transfer fluid. The higher inlet temperature and the more much inlet flow rate, thermal stratification in liquid-ice heat exchanger was established faster. In the case of adiabatic ice storage tank, temperature distribution was a little higher at all conditions than that of non-adiabatic one. The ratio of latent energy to total discharge energy($E_{\lambda}/E_[tot}$) was about 80%, and the discharge of latent heat energy was appeared rapidly as inlet temperature and flow rate were higher.

  • PDF

첨단기술

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.18 no.1 s.188
    • /
    • pp.57-60
    • /
    • 1985
  • 인마새트(INMASAT) / 해수온도차 에너지 / 연료전지 / 자동화 실리콘 컴파일러 개발

  • PDF

A Study on Boiling Characteristics of Direct Contact LNG Evaporator (직접접촉식 액화천연가스 기화기의 비등특성 연구)

  • 김남진;김종보
    • Journal of Energy Engineering
    • /
    • v.4 no.3
    • /
    • pp.420-428
    • /
    • 1995
  • 현재 사용하고 있는 액화천연가스 기화기는 관내부로 -162$^{\circ}C$의 액화가스가 흐르고, 관외부로 발전소 증기응축기 출구에서 배출된 20~3$0^{\circ}C$의 해수를 흐르도록 하여, 두 유체사이의 온도차로 기화시키는 간접접촉방식 열교환기가 사용되고 있다. 그러나 간접접촉방식 열교환기는 두 유체사이의 큰 온도차로 인한 금속재료의 피로현상과 해수의 염분에 의한 재질의 부식 및 미생물 부착 등의 원인으로 열전달효율이 저하되고 있다. 따라서 본 연구는 관을 중간매체로 하는 간접접촉식 열교환기대신 액화천연가스와 기화용수인 물을 직접접촉시키는 방법으로 이용하여, 위와 같은 문제점들을 근본적으로 해결하려 한다. 본 실험에서는 기화기내의 수위 500 mm와 물의 유량 10 l/min을 일정하게 고정시키고, 액화천연가스의 유량 0.12 ㅣ/min, 0.36 l/min, 0.6 l/min, 기화기내의 압력을 100 kPa, 300 kPa, 500kPa로 변화시키면서 기화기내의 기포, 온도분포, 급팽창현상, 동결현상 및 기화후 수분함유량등의 비등특성을 규명하였다. 실험결과 기화기내의 압력이 증가할수록 기포는 작고 균일한 분포를 이루고, 폭발적인 급팽창현상은 일어나지 않았다. 또한 동결현상은 액화천연가스의 기화를 방지하지 못하였으며, 기화된 천연가스내의 수분함유량 몰%는 압력과 유량이 증가함에 따라 감소하는 경향을 보이고 있다.

  • PDF

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

An Experimental Study on LTD Stirling Engine (MM-7) for the Development of TM Electric Conversion System (TM발전변환기 개발을 위한 저온도차 스털링엔진(MM-7)의 성능실측 연구)

  • Kim, Yeongmin;Chen, Kuan;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study has been carried out to develop TM (Thermal to Mechanical) conversion systems for electric power generation using one of the Low Temperature Differential (LTD) Stirling engines called MM-7 capable of harnessing low temperature waste heat whose temperature is only $20{\sim}30^{\circ}C$ above the ambient. Measurements were made on the torque and rpm for a number of temperature differentials between the engine hot and cold ends, which could be effectively applied in developing the most suitable configuration for the high performance TM (Thermal to Mechanical) conversion system.

박막형 열전 소재의 두께 방향 열전도도 측정 장비 개발

  • Kim, Yeong-Seok;Ha, Su-Hyeon;Gang, Sang-U;Song, Jae-Yong;Park, Seon-Hwa;Hyeon, Seung-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.112-112
    • /
    • 2016
  • 열전 발전은 버려지는 폐열을 재사용 가능한 에너지로 전환할 수 있다는 점에서 차세대 청정 에너지원으로 분류되며, 19세기 초 발견된 이래 꾸준히 연구되어온 연구 분야이다. 특히 1990년대 열전소재로의 나노 기술의 접목에 따라 열전성능(figure of merit, ZT)이 2 배 이상 증가 되면서, 고성능의 열전 소재 개발을 위해 나노구조화 연구가 활발히 진행되고 있다. 하지만, 기존의 열전 특성 측정용 상용 장비의 경우, 벌크형 소재를 대상으로 설계되어 연구실 수준에서 개발되고 있는 마이크로미터 스케일의 두께를 가지는 박막형 열전 소재의 두께 방향 (cross-plane)의 열전 특성을 평가하는데 정밀성이 떨어져서 적합하지 않다. 이러한 표준화된 측정 기술의 부재로 인하여 최근 연구되고 있는 나노소재들의 열전 특성 측정 결과를 정확하게 측정하지 못하고 있다 [1] 본 연구에서는 박막형 열전 소재의 열전성능을 평가하는데 가장 중요한 요소인 열전도도를 측정하기 위해 장비를 설계하고, 장비의 측정 능력에 대해 평가하였다. 특히, 측정 포인트 간 큰 온도 차가 발생하여 비교적 쉽게 측정이 가능한 너비 방향 (in-plane) 이 아닌, 온도 차가 작은 박막의 두께 방향의 열전도도를 측정하였다. 그리고 센서의 측정 능력을 평가하기 위해, 폴리이미드를 대상으로 $-10-70^{\circ}C$ 온도 범위에서 측정한 결과와 벌크형 소재 대상으로 신뢰성이 확보된 보호열판법을 이용해 측정한 결과를 비교하였다.

  • PDF

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

이상 유동이 존재하는 고체 로켓 노즐내에서의 성능손실에 대한 수치적 연구

  • 유만선;김병기;조형희;황기영;배주찬
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.30-30
    • /
    • 2000
  • 일반적인 소형 고체로켓의 모터 내에는 연료 첨가제로써 알루미늄이 함유되는데, 연소 시 산화된 이 성분은 액적 상태로 이동하여 노즐부내에 이상유동장을 형성시킨다. 이러한 산화알루미늄입자는 노즐벽면에 충돌, 점착하여 기계적, 열적 에너지전달을 일으키며 노즐벽면의 삭마를 유발시키는 한편, 가스유동과의 속도 차, 온도차로 인해 저항요소로 작용하면서 노즐의 추력 성능 손실에 간접, 직접적인 원인이 된다.(중략)

  • PDF

Behavior of secondary defects by high energy Implantation along Thermal Process (열처리에 따른 이온 주입시 발생하는 2차결함의 거동)

  • Kim, Suk-Goo;Kwack, Kae-Dal;Yoon, Sahng-Hyun;Park, Chul-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1827-1829
    • /
    • 1999
  • 반도체 소자가 고집적화 되고 미세화 될수록 좁은 면적에 여러 기능을 가진 우물을 형성시켜야하나 기존의 우물로는 고온 장시간 열처리로 인하여 측면 확산이 깊게 되고, 불순물 농도 분포는 표면으로부터 농도가 점차 낮아진다. 따라서 기존 우물의 불순물 분포로는 기생 트랜지스터에 의한 렛치-엎과 알파 입자에 의한 SER의 감소를 위하여 필요한 벌크에서의 고농도 분포를 유지하기가 곤란하다. 이러한 문제는 차세대 반도체 개발을 위해서는 반드시 해결해야 할 것이며 이것을 해결할 수 있는 공정으로는 고 에너지 이온 주입과 저온, 단시간 열처리이다. 고 에너지 이온 주입 시의 불순물 분포를 어떻게 제어할 것인가에 대한 것과 여기서 부수적으로 나타나는 격자 손상과 그 회복 및 잔류결함의 성질을 어떻게 알고 이를 게터링 등에 이용할 것이냐에 대한 것이다. 실리콘 기판 내로 가속된 이온은 실리콘 격자와 충돌하면서 많은 1차 결함이 생기고. 이들은 후속 열처리 과정에서 활성화되면서 대부분은 실리콘 격자의 위치에 들어가 활성화되고. 그 나머지는 실리콘내의 격자간 산소, 격자간 실리콘. 격자 빈자리와 상호 작용을 하여 2차 결함을 형성한다. 에피택셜 웨이퍼와 p-type웨이퍼에 비소 이온을 고에너지로 주입후 2단계 열처리에 의한 농도분포변화와 핵생성과 결함성장에 관해 실험하였고, 핵생성온도는 $600^{\circ}C$이하이고, 성장에 필요한 온도는 $700^{\circ}C$이상이다.

  • PDF

Experimental Analysis of Thermal Comfort of an Office Space for Different Supply Locations during Cooling (냉방시 사무실 공간의 급기 위치에 따른 실내 열환경 평가 실험)

  • 김명호;김요셉;김영일
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.115-120
    • /
    • 1999
  • 본 연구에서는 실제 조건과 유사하게 모사된 사무실 공간을 대상으로 냉방시 급기 위치에 따른 기온, 기류속도, 복사온도를 측정하여 열환경을 평가하였다. 사무실 공간은 실제의 조건과 유사하게 인체, 조명, 사무기기의 부하를 전기히터로 모사했으며, 외기부하는 벽체에 설치된 열교환기를 통과하는 부동액의 온도를 제어함으로써 모사하였다. 실험 결과 냉방 조건에서는 바닥급기 방식의 경우 평균온도가 천장급기에 비해 낮아 에너지 절약 측면에서 유리함을 알 수 있었다. 그러나 천장급기에 비해 수직온도차가 크고 급기구 근처에서는 수직온도차에 의한 불쾌감과 빠른 기류속도에 의한 드래프트의 위험이 있는 것으로 나타났다.

  • PDF