• Title/Summary/Keyword: 온도별

Search Result 3,264, Processing Time 0.038 seconds

Diurnal Changes of Leaf Water Potential in Cuttings (삽수(挿穗)의 Leaf Water Potential의 변화(變化))

  • Hong, Sung Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.38 no.1
    • /
    • pp.27-32
    • /
    • 1978
  • The diurnal pattern of leaf water potential in cuttings by Dye Method was as follows: 1. Diurnal pattern of leaf water potential (${\psi}_l$) in Viburnum Awabuki K. Koch and Daphne odora Thunb. was shown the pattern of the curves without mutual relation with soil classes when soil water potential (${\psi}_s$) was 0 bar. When ${\psi}_s$ was above -0.01 bar, the cuttings in the loamy sand (L.S.) was shown by the maximum values than that in sandy clay (S.C.) by about -1 bar gap (Fig. 1). 2. The diurnal changes of ${\psi}_l$ was shown the most high from two to eight O'clock in the morning, the maximum value was -3 bars when ${\psi}_s$ was above -0.01 to -0.02 bar, and was -4 bars below -0.03 bar. The diurnal the lowest values of ${\psi}_l$ showed -20 to -22 bars from one to two O'clock in the afternoon. In the fifteenth day after cutting V.A., the staying time in the diurnal maximum values of ${\psi}_l$ is about half in comparison with it in the fifth day. The curves of recovery of water stress (Fig. 1), the former reached to the diurnal maximum values -1 to -2 bars lately every hours comparing with it of the latter. The general diurnal pattern of ${\psi}_l$ was most clearly related to change with air temperature and the relative humitidy. 3. Comparing the treatment block by IAA 50 ppm with controlled block in fifteenth day after V.A. cuttings, in case of treatment reached to maximum values -2 to -3 bars lately as shown Fig. 2., and also staying times was only half in comparison with controlled block. 4. The cuttings 4 leafs was much rootings than 2 leafs in V.A. (Table. 1), and the former reached maximum value -2 to -3 bars lately every hours comparing with the latter. 5. In case of Buxus microphylla var. Koreana as shown Fig. 3., comparing the pattern curves of in the cuttings 8 leafs with 4 leafs, the former reached to maximum values -2 to -3 bars lately in comparison with the latter, but reffering to the amount of rooting (Table. 2), the former is less than the latter.

  • PDF

An Approach to Determine the Good Seedling Quality of Grafted Tomatoes (Solanum Lycopersicum) Grown in Cylindrical Paper Pot Through the Relation Analysis between DQI and Short-Term Relative Growth Rate (DQI와 단기 상대생장률 분석을 이용한 원통형 종이포트 토마토 접목묘의 우량묘 기준 설정)

  • Seo, Tae Cheol;An, Se Woong;Jang, Hyun Woo;Nam, Chun Woo;Chun, Hee;Kim, Young chul;Kang, Tae Kyung;Lee, Sang Hee
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.302-311
    • /
    • 2018
  • Using cylindrical paper pot nursery method, three kinds of commercial tomatoes 'Dafnis', 'DOTAERANG DIA' and 'Maescala' were grafted onto a commercial rootstock 'B blocking'. From 10 to 40 days after graft-take, growth traits of seedlings were investigated by 0.5, 1.0 and 2.0S treatments of standard nutrient solution(S) for seedling growth, and top to root ratio(TRR), compactness(CP) and Dickson Quality Index(DQI) were calculated. Two weeks after transplanting of the seedlings under three different night temperature targeting to 10, 15, and $25^{\circ}C$, which were not precisely controlled, the relative growth rate (RGR) was investigated. The quantitative growth traits of grafted seedlings increased with increasing fertilizer concentration, and various range of seedling size could be produced. Compactness and DQI were significantly regressed (Adj $R^2=0.9480$). Short-term RGR after transplanting was higher at 1.0S treatment of standard nutrient solution at the seedling age of 30 days and 40 days after graft-take(DAGT). DQI and RGR were significantly regressed linearly at respective fertigation strength. Specially the diminishing slope of RGR was lower at 1.0S fertigation strength with the increase of DQI than others. The results indicate that DQI could be applied as a quality index of grafted tomato seedlings and the relation analysis between DQI and short-term RGR also could be used to determine the good quality seedlings of grafted tomato grown in cylindrical paper pot.

Effect of Curing Conditions on Inhibition of Tuber Rot in Subtropical Yam (Dioscorea alata) during Storage (아열대 마(Dioscorea alata)의 저장중 부패 억제를 위한 큐어링 효과)

  • Kim, Ki-Sun;Kwon, Soon-Bae;Chang, Kwang-Jin;Hong, Sae-Jin;Kim, Byung-Sup
    • Korean Journal of Plant Resources
    • /
    • v.25 no.4
    • /
    • pp.387-393
    • /
    • 2012
  • In order to improve storability of subtropical yam produced in South Korea, the major pathogens found during the storage were isolated and identified of the pathogenicity, and rot inhibition effect was studied based on the curing treatment condition. Penicillium sclerotigenum and Penicillium polonicum were identified as major pathogens causing rot in subtropical yam during storage, and P. sclerotigenum had stronger pathogenicity. Only the cut surface which has been made during a harvest and has been made smooth before curing generated a normal callus layer. The cut surface of tuberous root was cured in 95% of relativity humidity for three days at $23^{\circ}C$, and cured at $28^{\circ}C$ and $33^{\circ}C$. The observation of callus layer showed that the $23^{\circ}C$ treatment group had similar color saturation between tuberous root and pellicle, while the groups treated above $28^{\circ}C$ showed clear distinction. The generation rate of callus 0.5mm or bigger was 93 percent at $28^{\circ}C$ treatment, 96% at $33^{\circ}C$ treatment, but was 52% at $23^{\circ}C$ treatment. The conventional curing treatment group that used wind or sunlight at room temperature created little callus layer. The infection rate of pathogens according to the relative humidity inside the storage room was low at 40% and 60% of humidity, and the curing treatment period did not make a difference. When the humidity inside the storage room was 80%, all treatment groups rapidly increased the fungal pathogens. The rotten rate of each treatment was studied after 180 days during which the storage temperature was maintained at $16^{\circ}C$ and relative humidity 60%. While the rotten rate of tuberous root that has been cut in conventional curing treatment based on solar and wind was 43%, the one cured at over $28^{\circ}C$ and created the callus layer was less than 18%. While even a healthy tuberous root showed 25% of rotten rate in the traditional treatment group, the one cured at over $28^{\circ}C$ was less than 10%. The weight loss was 1-6% lower in the forced treatment group than in the conventional treatment group.

Studies on Seed Germination Characteristics of Rice Cultivar ‘Danmi’ and Its Optimum Seeding Rates for Seedling Raising in Machine Transplanting (단미벼의 발아 특성 및 기계이앙 육묘시 적정 파종량)

  • Kim, Sang-Yeol;Oh, Seong-Hwan;Lee, Jong-Hee;Jeong, Kuk-Hyun;Cho, Jun-Hyeon;Lee, Ji-Yoon;Park, Sung-Tae;Song, You-Chun;Yeo, Un-Sang;Kim, Jeong-Il;Seo, Woo-Duck;Kang, Hang-Won
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.2
    • /
    • pp.126-132
    • /
    • 2010
  • A high sugar rice cultivar 'Danmi' which has been recently developed and released in the Functional Crop Resource Development Division, Department of Functional Crop, National Institute of Crop Science, has high glucose and sucrose contents but has a poor seed development. This defect poses some problem in ensuring stable seedling establishment in the nursery bed. We examined the germination and seedling emergence characteristics of 'Danmi' and determined an optimum seeding rate for seedling establishment. 'Danmi' seeds has a light 1,000-grain weight of 18.2g compared with Ilmibyeo's 26.7g. The 97.4% of 'Danmi' seeds has specific gravity below 1.0 while only 2.0% of seeds was fully developed with specific gravity above 1.12. However, the reverse is true in the Ilmibyeo seed used as a control cultivar. Although the seed germination of Danmi was 89-91% regardless of seed specific gravity but at a slower rate than Ilmibyeo regardless of water soaking temperatures of $20-30^{\circ}C$ because of high seed amount of specific gravity below 1.0 in 'Danmi'. It took 2~4 days longer of seed soaking in the Danmi seeds than Ilmibyeo before germination. 'Danmi' has low normal seedling emergence rate than Ilmibyeo in the seedbed soil due to high percentage of abnormal seedlings like stunting and incomplete growth. Normal seedling emergence rate of 'Danmi' in the seedbed was 62.6~64.9% for 10-day old seedling and 83.5~86.7% for 30-day old seedling which is lower by 29.6~30.0% and 11.3~12%, respectively than Ilmibyeo. Although 'Danmi' has low normal seedling emergence rate, but it has greater seed number per weight basis. Therefore, based on the normal seedling number per unit area of Ilmibyeo(control cultivar) for seedling rate of 10-day and 30-day old seedlings, the recommended seeding rate of 'Danmi' for transplanting rice is 220g seeds for 10-day old seedling and 130g for 30-day old seedling per nursery box, which is equivalent to 1.5 times seed volumes of Ilmibyeo.

A study on the emission characteristics of greenhouse gases according to the vehicle technology, fuel oil type and test mode (차량기술, 연료 유종 및 시험모드 특성에 따른 온실가스의 배출특성 연구)

  • Lee, Jung-Cheon;Lee, Min-Ho;Kim, Ki-Ho;Park, An-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.962-973
    • /
    • 2017
  • Concerns about an air pollution are gradually increasing at home and abroad. The automotive and fuel researchers are trying to reduce emissions and greenhouse gases of vehicles through a research on new engine designs and innovative after-treatment systems using clean fuels (eco-alternative fuel) and fuel quality improvements. In this paper, we stduy the emission characteristics of greenhouse gases on seven vehicles using gasoline, diesel, and LPG by legal test mode in domestic and abroad.(Urban mode, Highway mode, rapidly acceleration and deceleration, using air conditioner, low temperature condition) Regardless of fuels, most of the greenhouse gases tend to show the worst results in cold FTP-75 mode. In the case of A vehicles (2.0 MPI) and B vehicles (2.4 GDI) using a gasoline fuel, the factors that increase greenhouse gases are in order of a rapidly acceleration and deceleration, using air conditioner, low temperature condition. But G vehicles(LPLi) have different emission characteristics from another vehicles. In the case of A vehicles (2.0 w/o DPF) and B vehicles (2.2 with DPF) using a diesel fuel, the factors that increase greenhouse gases are in order of a rapidly acceleration and deceleration, using air conditioner, low temperature condition. However, the factor of F vehicles are in order of low temperature condition, using air conditioner, rapidly acceleration and deceleration. In conclusion, it will be an effective method to apply different technologies of emission reduction for each fuel.

Comparative Analysis of the Effects of Heat Island Reduction Techniques in Urban Heatwave Areas Using Drones (드론을 활용한 도시폭염지역의 열섬 저감기법 효과 비교 분석)

  • Cho, Young-Il;Yoon, Donghyeon;Shin, Jiyoung;Lee, Moung-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_3
    • /
    • pp.1985-1999
    • /
    • 2021
  • The purpose of this study is to apply urban heat island reduction techniques(green roof, cool roof, and cool pavements using heat insulation paint or blocks) recommended by the Environmental Protection Agency (EPA) to our study area and determine their actual effects through a comparative analysis between land cover objects. To this end, the area of Mugye-ri, Jangyu-myeon, Gimhae, Gyeongsangnam-do was selected as a study area, and measurements were taken using a drone DJI Matrice 300 RTK, which was equipped with a thermal infrared sensor FLIR Vue Pro R and a visible spectrum sensor H20T 1/2.3" CMOS, 12 MP. A total of nine heat maps, land cover objects (711) as a control group, and heat island reduction technique-applied land covering objects (180) were extracted every 1 hour and 30 minutes from 7:15 am to 7:15 pm on July 27. After calculating the effect values for each of the 180 objects extracted, the effects of each technique were integrated. Through the analysis based on daytime hours, the effect of reducing heat islands was found to be 4.71℃ for cool roof; 3.40℃ for green roof; and 0.43℃ and -0.85℃ for cool pavements using heat insulation paint and blocks, respectively. Comparing the effect by time period, it was found that the heat island reduction effect of the techniques was highest at 13:00, which is near the culmination hour, on the imaging date. Between 13:00 and 14:30, the efficiency of temperature reduction changed, with -8.19℃ for cool roof, -5.56℃ for green roof, and -1.78℃ and -1.57℃ for cool pavements using heat insulation paint and blocks, respectively. This study was a case study that verified the effects of urban heat island reduction techniques through the use of high-resolution images taken with drones. In the future, it is considered that it will be possible to present case studies that directly utilize micro-satellites with high-precision spatial resolution.

Evaluating Cultivation Environment and Rice Productivity under Different Types of Agrivoltaics (유형이 다른 영농형 태양광발전시설 하부 재배 환경 및 벼 생산성 평가)

  • Ban, Ho-Young;Jeong, Jae-Hyeok;Hwang, Woon-Ha;Lee, Hyeon-Seok;Yang, Seo-Yeong;Choi, Myoung-Goo;Lee, Chung-Keun
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.4
    • /
    • pp.258-267
    • /
    • 2020
  • The agrivoltaic can produce electricity and grow crops on fields at the same time. It is necessary to analyze the cultivation environment and evaluate the crop productivity under agrivoltaic because the shading point changes according to structure of agrivoltaic and sun's position. Two types of "fixing" and "tracing" agrivoltaic were installed, and a rice cultivation experiment was conducted in the fields under each agrivoltaic and without shading (control). "Hyunpoombyeo" was transplanted on June 7, 2019, and grown with fertilization of 9.0-4.5-5.7 kg/10a (N-P-K). Fifteen weather stations were installed under each agrivoltaic to measure solar radiation and temperature, and yield and yield-related elements were investigated by points. The accumulated solar radiation during the rice growing season in fixing was no much difference between points, and that in tracing was much difference between points. However, the average solar radiations of two agrivoltaics were similar. The mean temperature, yield, and yield-related elements showed a significant difference for the shading rate, and decreased with increasing the shading rate except ripening grain rate and 1000 grain weight of fixing agrivoltaic. In the relationship between shading rate and yield, fixing and tracing were fitted to a logistic equation and a simple linear equation, respectively, and showed a high correlation (tracing: R2 = 0.62, fixing: R2 = 0.73). The shading rate variation by point for two types was large despite similar yield variation. Thus, it needs to be more closely examined the relationship of the shading rate for a specific period rather than the shading rate during the whole growing season.

Sapflux Measurement Database Using Granier's Heat Dissipation Method and Heat Pulse Method (수액류 측정 데이터베이스: 그래니어(Granier) 센서 열손실탐침법(Heat Dissipation Method)과 열파동법(Heat Pulse Method)을 이용한 수액류 측정)

  • Lee, Minsu;Park, Juhan;Cho, Sungsik;Moon, Minkyu;Ryu, Daun;Lee, Hoontaek;Lee, Hojin;Kim, Sookyung;Kim, Taekyung;Byeon, Siyeon;Jeon, Jihyun;Bhusal, Narayan;Kim, Hyun Seok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.4
    • /
    • pp.327-339
    • /
    • 2020
  • Transpiration is the movement of water into the atmosphere through leaf stomata of plant, and it accounts for more than half of evapotranspiration from the land surface. The measurements of transpiration could be conducted in various ways including eddy covariance and water balance method etc. However, the transpiration measurements of individual trees are necessary to quantify and compare the water use of each species and individual component within stands. For the measurement of the transpiration by individual tree, the thermometric methods such as heat dissipation and heat pulse methods are widely used. However, it is difficult and labor consuming to maintain the transpiration measurements of individual trees in a wide range area and especially for long-term experiment. Therefore, the sharing of sapflow data through database should be useful to promote the studies on transpiration and water balance for large spatial scale. In this paper, we present sap flow database, which have Granier type sap flux data from 18 Korean pine (Pinus koraiensis) since 2011 and 16 (Quercus aliena) since 2013 in Mt.Taehwa Seoul National University forest and 18 needle fir (Abies holophylla), seven (Quercus serrata), three (Carpinus laxiflora and C. cordata each since 2013 in Gwangneung. In addition, the database includes the sapling transpiration of nine species (Prunus sargentii, Larix kaempferii, Quercus accutisima, Pinus densiflora, Fraxinus rhynchophylla, Chamecypans obtuse, P. koraiensis, Betulla platyphylla, A. holophylla, Pinus thunbergii), which were measured using heat pulse method since 2018. We believe this is the first database to share the sapflux data in Rep. of Korea, and we wish our database to be used by other researchers and contribute a variety of researches in this field.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.

Comparing Net CO2 Uptake of Schlumbergera truncata 'Pink Dew' Phylloclades in a Growth Chamber and a Greenhouse (생육상과 온실에서 게발선인장 '핑크듀'의 엽상경별 CO2 흡수율 비교)

  • Seo Hee Jung;Ah Ram Cho;Yoon Jin Kim
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.64-71
    • /
    • 2023
  • Crassulacean acid metabolism (CAM) plants use surplus CO2 generated by cooling and heating at night when ventilation is not needed in a greenhouse. Schlumbergera truncata 'Pink Dew' is a multi-flowering cactus that needs more phylloclades for high-quality production. This study examined photosynthetic characteristics by the phylloclade levels of S. truncata in a growth chamber and a greenhouse for use of night CO2 enrichment. The CO2 uptake rate of the S. truncata's top phylloclade in a growth chamber exhibited a C3 pattern, and the second phylloclade exhibited a C3-CAM pattern. The CO2 uptake rate of the top phylloclade in a greenhouse showed a negative value both day and night, but those of the second phylloclade exhibited a CAM pattern. The stomatal conductance and water-use efficiency (WUE) of S. truncata at both the top and second phylloclades were higher in a growth chamber than in a greenhouse. The WUE of S. truncata in a growth chamber and a greenhouse was higher at the second phylloclade, which is a CAM pattern compared with those of the top phylloclade. The daily total net CO2 uptake of S. truncata was higher in a growth chamber than in a greenhouse. The daily total net CO2 uptake of S. truncata at the second phylloclade had the highest value of 155 mmol·m-2·d-1 in a growth chamber. The night total CO2 uptake of S. truncate at the second phylloclade was 3-fold higher in a growth chamber than in a greenhouse. S. truncata's second phylloclade exhibited a CAM pattern that uptake CO2 at night, and the second phylloclade, was more mature than the top phylloclade. A multi-flowering cactus S. truncata 'Pink Dew' efficiently uptake night surplus CO2 in the proper environmental condition with matured phylloclade.