• Title/Summary/Keyword: 온도민감도

Search Result 810, Processing Time 0.026 seconds

Analysis of Operating Characteristics of 200kW Class Micro Gas Turbine (200kW 급 마이크로 가스터빈의 운전특성 분석)

  • Kim, Jeong Ho;Kang, Do Won;Kim, Tong Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1015-1022
    • /
    • 2013
  • This study simulates the operation of a 200 kW class micro gas turbine that is currently under development. The performance and operating characteristics depending on the load control scheme (constant turbine inlet temperature versus constant turbine exit temperature) and ambient condition were investigated using detailed component performance data. The sensitivities of operating parameters, such as the compressor surge margin and flow path temperatures, according to unit fuel flow change were predicted for a wide load range. The sensitivity analysis showed that the steady state calculation provided useful information about the maximum surge margin reduction during load change.

Surface Temperature Measurements in Microscale with Temperature Sensitive Fluorescence (온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정)

  • Jung, Woon-Seop;Kim, Sung-Wook;Kim, Ho-Young;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1225-1230
    • /
    • 2004
  • The effects of substrate material on the local heating performance of microheaters are studied by both numerical analysis and experiment. Transient conduction analysis shows that the substrate material with low thermal conductivity is critical to the local heating and fast response. A measurement technique for surface temperature field in microscale is newly proposed, which uses temperature sensitive fluorescent dye coated on the surface. The measured surface temperature fields on microheater arrays fabricated on different substrates are presented.

  • PDF

DNBR Sensitivities to Variations in PWR Operating Parameters (가압경수로의 운전변수 변화에 대한 DNBR의 민감도)

  • Hyun Koon Kim;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.236-247
    • /
    • 1983
  • Analyzed are the the DNBR(Departure from Nucleate Boiling Ratio) sensitivities to variations in various PWR operating parameters utilizing the Korea Nuclear Unit 1(KNU-1) design and operating data. Studied parameters in the analysis are core power level, system pressure, core inlet flow rate, core inlet temperature, enthalpy rise hot channel factor, and axial power peaking factor and axial offset. The calculations are performed using the steady state and transient thermal-hydraulics computer program, COBRA-IV-K, which is the revised version of COBRA-IV-i that has been adapted, partially modified and verified at KAERI. A reference case is established based on the design and operating condition of the KNU-1 reactor core, and this provides a basis for the subsequent sensitivity analysis. From the calculation results it is concluded that the most sensitive parameter in the DNBR thermal design is the coolant core inlet temperature while the axial power peaking factor is the least sensitive.

  • PDF

Evaluation of Sensitivity and Retrieval Possibility of Land Surface Temperature in the Mid-infrared Wavelength through Radiative Transfer Simulation (복사전달모의를 통한 중적외 파장역의 민감도 분석 및 지표면온도 산출 가능성 평가)

  • Choi, Youn-Young;Suh, Myoung-Seok;Cha, DongHwan;Seo, DooChun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1423-1444
    • /
    • 2022
  • In this study, the sensitivity of the mid-infrared radiance to atmospheric and surface factors was analyzed using the radiative transfer model, MODerate resolution atmospheric TRANsmission (MODTRAN6)'s simulation data. The possibility of retrieving the land surface temperature (LST) using only the mid-infrared bands at night was evaluated. Based on the sensitivity results, the LST retrieval algorithm that reflects various factors for night was developed, and the level of the LST retrieval algorithm was evaluated using reference LST and observed LST. Sensitivity experiments were conducted on the atmospheric profiles, carbon dioxide, ozone, diurnal variation of LST, land surface emissivity (LSE), and satellite viewing zenith angle (VZA), which mainly affect satellite remote sensing. To evaluate the possibility of using split-window method, the mid-infrared wavelength was divided into two bands based on the transmissivity. Regardless of the band, the top of atmosphere (TOA) temperature is most affected by atmospheric profile, and is affected in order of LSE, diurnal variation of LST, and satellite VZA. In all experiments, band 1, which corresponds to the atmospheric window, has lower sensitivity, whereas band 2, which includes ozone and water vapor absorption, has higher sensitivity. The evaluation results for the LST retrieval algorithm using prescribed LST showed that the correlation coefficient (CC), the bias and the root mean squared error (RMSE) is 0.999, 0.023K and 0.437K, respectively. Also, the validation with 26 in-situ observation data in 2021 showed that the CC, bias and RMSE is 0.993, 1.875K and 2.079K, respectively. The results of this study suggest that the LST can be retrieved using different characteristics of the two bands of mid-infrared to the atmospheric and surface conditions at night. Therefore, it is necessary to retrieve the LST using satellite data equipped with sensors in the mid-infrared bands.

Evaluation and Comparison with Standard 48 hr Acute Bioassay and High Temperature Rapid Toxicity Test for Sewage Toxicity Test (하수의 독성평가를 위한 표준독성시험법과 온도증가 단기독성평가법의 비교 평가)

  • Lee, Sang-Ill;Jun, Byong-Hee;Weon, Seung-Yeon;Kim, Yi-Jung;Kim, Keum-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • A new method, ToxTemp (TOXcity test based on TEMPerature control) using Ceridaphnia dubia was applied to evaluate the toxicity of insecticide materials and compared with the standard 48 hr acute bioassay. BPMC, diazinon and fenitrothion may cause the inhibition to the biological process in sewage treatment plant and need to detect toxicity within short contact time. The ToxTemp method showed sensitive detection with more shorter contact of 1-1.5 hr time than that of the standard 48 hr acute bioassay. To evaluate toxicity of real wastewater/sewage, the inhibition rate of nitrification and oxygen uptake rate (OUR) using activated sludge, the standard 48hr acute bioassay and ToxTemp method using C. dubia were compared, respectively. On the basis of the inhibition rate of nitrification, the OUR test showed the less sensitive results at the relatively strong toxic sewage. On the other hands, the standard 48hr acute bioassay and ToxTemp method using C. dubia represented the toxicity of each wastewater/sewage with high sensitivity. Even the slightly low (about 1.5%) sensitivity, the ToxTemp method showed the high applicability to the real site of sewage treatment plant.

Sensitivity Analyses of the Meteorological Factors in the Estimation of Evapotranspiration Rates (증발산량 산정에 있어서 기상학적 요인들의 민감도 해석)

  • 임창수
    • Journal of Environmental Science International
    • /
    • v.5 no.5
    • /
    • pp.657-662
    • /
    • 1996
  • Meteorological and flux data measured from semiarid watersheds (Lucky Hills and Kendall) during the summer rainy and winter periods were used to study the sensitivity of the those variables used in the estimation of evapotranspiration rates. Relative sensitivity was examined to compare the importance of four meteorological and flux variables (net radiation wind speed, air temperature, and relative humidity) on Penman potential evapotranspiration (PET) estimation. The study results show that variations in Penman PET rates during the summer rainy period at both watersheds appears to be controlled by air temperature adn net radiation. During the winter period at both watersheds, wariations in Penman PET rates appears to be controlled by relative humidity and air temperature.

  • PDF

Temperature-time Profile during Epoxy Cure in a Mold (Mold내의 에폭시 수지 경화시 시간에 따른 내부 온도의 변화)

  • Kim, Deuk-Su;Kim, Jong-Hyeon;Lee, Jong-Geun
    • Korean Journal of Materials Research
    • /
    • v.7 no.3
    • /
    • pp.244-250
    • /
    • 1997
  • 본 연구에서는 에폭시/산무수물계에 경화촉진제를 첨가한 시료를 몰드(mold)내에서 등온 경화시킬 때 시료 내부의 온도변화를 측정하여 얻어진 온도-시간 곡선(temperature-time profile)을 조사하였다. 실험에 사용한 경화촉진제의 종류는 1-cyanoethy1-2-ethy1-4-methy1 imidazole(1E4MZ-CN), N,N-dimethy1 benzy1 amine(BDMA), 2,4,6-tris(dimethy1-aminomethy1)-phenol(DMP-30)이며 그들의 농도(c)는 1.0,1.5,2.0,2.5,phr그리고 경화온도(T$_{cure}$ )는 65,70,85,95$^{\circ}C$로 하였다. 경화가 진행되는 동안 시료내부의 온도는 초기에 경화온도로 상승한 후 본격적인 경화 반응이 일어나기 시작하여 온도가 급격히 상승하였다가 다시 감소하는 양상을 보였다. 온도-시간 곡선상에 나타나는 온도가 최고로 상승되는 시점(t$_{peak}$ )과 그 때의 온도(T$_{peak}$ )는 촉진제의 종류와 농도 그리고 경화온도에 의하여 영향을 받았다. 사용한 경화촉진제중에 DMP-30이 가장 짧은 t$^{peak}$ 값을 가져 가장 우수한 촉진 효과를 갖는 것으로 나타났으며, T$_{peak}$ 는 촉진제의 농도와 경화온도가 증가할수록 상승하였다. 그리고 경화촉진제의 농도와 경화온도의 변화에 따른 t$_{peak}$ 과 T$_{peak}$ 의 변화를 보면 촉진제 농도와 경화온도가 낮을 때 그 변화가 민감하여 2E4MZ-CN 이 가장 민감한 촉진제로 나타났으며 또한 T$_{peak}$ 에 영향을 주는 여러가지 요소들을 본 연구에서 얻어진 결과로부터 자세히 살펴보았다.

  • PDF

A Study on the Thermal Sensitivity of the Solid Fuel Grain with respect to the Port Distance in Hybrid Rocket Motor (Multi-port 하이브리드 로켓의 포트간의 거리에 따른 고체 연료의 열민감도에 관한 연구)

  • Do, Gyu-Sung;Yoon, Chang-Jin;Moon, Hee-Jang;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.233-236
    • /
    • 2007
  • In this paper, thermal sensitivity of the solid fuel grain in the hybrid rocket motor was investigated. When the heat from the non-reacting hot flow passing the grain ports is transferred to the solid fuel grain, the temperature fields in the solid fuel was numerically analyzed. These numerical analyzes were performed under the different nine port radii, and the critical distance between the ports in which the temperature in the solid fuel is sensibly responding was determined. Thus, the critical distance between the ports would be the important consideration for the design of the fuel grain because the high temperature in the fuel can bring the structural problems.

  • PDF

A Study on Sensitivity Analysis for Numerical Solution of Passenger Train Fire (여객 열차 화재의 수치해석을 위한 민감도 분석)

  • Kim, Woo-Seok;Roh, Sam-Kew;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • The aim of this study is to analyse the sensitivity of fire simulation parameters including grid size and solid angle number which affect the performance of subway cabin fire simulation by FDS 4.07 version. The results of sensitivity analysis shows average of $10{\sim}20%$ differences in plume temperature, upper layer temperature, and layer height depending on the change of grid size. The study also shows that simulation with 0.05m grid size produces better resolution than that with coarse one which is 0.1m.

Measurement of atmospheric temperature by UsingRotational Raman signal of nitrogen and Oxygen (질소와 산소의 회전-라만 신호를 이용한 대기온도의 원격 측정)

  • 김덕현;차형기;이종민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.110-111
    • /
    • 2001
  • 대기과학분야에서 대기의 온도는 풍향-풍속과 더불어 매우 중요한 기상파라메타로 사용되고 있다. 수직고도에 따른 온도의 변화는 대기의 안정도를 결정하기도하며 구름의 생성과 소멸에 직접적인 변수가 되기도 한다. 원격으로 온도를 측정하는 기술 중에서 가장 보편적으로 사용되는 방법은 산소나 질소의 회전 라만 신호를 이용하는 기술이다 이 방법은 Cooney에 의하여 최초로 시도되었는데, 온도에 따라 민감하게 변하는 두 개의 회전천이 스펙트럼을 측정함으로써 이루어진다. (중략)

  • PDF