• Title/Summary/Keyword: 오차분리

Search Result 398, Processing Time 0.026 seconds

Performance Evaluation of a Cellular OFDM System with Heterogeneous MIMO Users (이질적인 MIMO 사용자들을 가진 셀룰러 OFDM 시스템의 성능 분석)

  • Oh Joon;Hwang Hyeon chyeol;Lim Jong kyoung;Kim Duk kyung;Kwak Kyung sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4A
    • /
    • pp.296-303
    • /
    • 2005
  • In this paper, we evaluate system performance and propose signal separation and detection when a user with one antenna shares the co-channel together with a user with two space-time coded antennas. The proposed technique can identify co-channel users by an interference cancellation method and detect the signals by maximum likelihood method. Simulation results show that the shortcoming of the Minimum Mean-Squared Error technique which can be applied two users with the same number of antenna but can not applied for heterogeneous MIMO users with the different number of antennas. Also, we apply the proposed scheme to OFDM system and evaluate the system performance. By simulations, we identify that the performance of the proposed system is the same as that of the existing single antenna users and improves the performance of the two-antenna MIMO users.

A Selective Determination Method of Inorganic and Organic Mercury (무기수은과 유기수은의 선택정량)

  • Kim, Chon Han
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.8
    • /
    • pp.392-398
    • /
    • 1997
  • A method of selective determination of inorganic and organic mercury compounds has been described. The $CHCl_3$ solution of a high molecular quaternary alkylammonium salt, Aliquat 336 was used for the simultaneous preconcentration of both inorganic, $Hg^{2+}$ as its thiocyanate complex, and organic mercury compounds, $CH_3HgCl$ and $C_2H_3O_2$ $HgC_6H_5$ by extraction from their aqueous solution. Selective separation of the inorganic mercury from the extract was followed by stripping with 3 M $HClO_4 $ solution for the subsequent determination by CVAAS. Organic mercury was also determined by CVAAS after removal of $CHCl_3solvent$ from the extract and decomposition of the residue with 4% $KMnO_4 $-1 MH_2$S0_4$. The mixtures of inorganic and organic mercury compounds contained 1.0 $\mug$ as Hg in 50 mL of sample solution(0.02 ${\mu}gHg/mL$) were analysed within ${\pm}6%$ by absolute errors.

  • PDF

Panorama Background Generation and Object Tracking using Pan-Tilt-Zoom Camera (Pan-Tilt-Zoom 카메라를 이용한 파노라마 배경 생성과 객체 추적)

  • Paek, In-Ho;Im, Jae-Hyun;Park, Kyoung-Ju;Paik, Jun-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.3
    • /
    • pp.55-63
    • /
    • 2008
  • This paper presents a panorama background generation and object tracking technique using a Pan-Tilt-Zoom camera. The proposed method estimates local motion vectors rapidly using phase correlation matching at the prespecified multiple local regions, and it makes minimized estimation error by vector quantization. We obtain the required image patches, by estimating the overlapped region using local motion vectors, we can then project the images to cylinder and realign the images to make the panoramic image. The object tracking is performed by extracting object's motion and by separating foreground from input image using background subtraction. The proposed PTZ-based object tracking method can efficiently generated a stable panorama background, which covers up to 360 degree FOV The proposed algorithm is designed for real-time implementation and it can be applied to many commercial applications such as object shape detection and face recognition in various surveillance video systems.

저궤도 위성의 궤도 특성에 따른 버스 운용 고려 사항

  • Jeon, Moon-Jin;Kim, Day-Young;Kim, Gyu-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.198.1-198.1
    • /
    • 2012
  • 저궤도 위성이 발사체에서 분리된 후 탑재 소프트웨어에 의한 초기 동작이 수행되고 나면 초기 운용이 시작된다. 초기 운용 기간에 수행할 모든 절차와 대처 가능한 긴급 상황이 발생할 경우 수행할 절차는 발사 전에 미리 준비된다. 위성의 각 부분의 설계 마진은 최악 조건을 기준으로 반영되어 있기 때문에 발사 이후의 버스 시스템 관점에서의 위성 특성은 요구 사항을 만족하는 범위가 될 것으로 예상이 가능하다. 실제로 발사 후 위성 텔레메트리 분석을 통해 대부분의 항목에서 요구 조건을 만족하는 것으로 확인되었다. 또한 텔레메트리 분석을 통해 설계 단계에서 예상했던 것 보다 정확한 궤도 특성이 반영된 위성 특성을 파악하였다. 이러한 특성은 설계 시 고려했던 상황과 다르더라도 실제 궤도 특성이 반영된 특성이므로 초기 운용 및 정상 운용 시에 정상적인 상황인 것으로 고려해야 한다. 첫째, 지구 알베도 특성에 따라 태양센서 값이 궤도에 따라 변화한다. 위성의 자세가 정확히 태양을 지향하고 있더라도 태양센서에 지구에서 반사된 빛이 입사되어 자세 제어에 영향을 주게 된다. 알베도의 영향은 적도에서 극지방으로 갈수록 커지며, 계절에 따라 다른 특성을 보인다. 알베도의 영향을 최소화하기 위해 자세 제어 모델에 알베도 효과를 고려하거나 알베도 효과를 무시할 수 있을 정도로 자세 제어 오차 한계를 조정할 수 있다. 둘째, 위성의 지구 회피 회전에 의해 태양 전지판의 온도가 궤도에 따라 변화한다. 위성체는 위성체에 장착된 두 개의 별센서의 가시성 확보를 위해 태양 지향 자세에서 요축으로 일정 속도로 회전한다. 남극 부근에서는 두 태양 센서가 모두 지구의 반대편인 남쪽을 지향하도록 하며, 북극 부근에서는 북쪽을 지향하도록 한다. 이 때 두 태양 센서의 방향에 장착된 태양 전지판은 극지방에서 지구 반대편에 위치하므로 다른 태양 전지판에 비해 낮은 온도를 갖게 된다. 이 논문에서는 위성의 궤도 특성에 따른 고려 사항에 대해 설명하였다.

  • PDF

The Study on Coordinate Transformation for Updating of Digital Map from Construction Drawing Data (건설도면 자료의 수치지도 갱신을 위한 좌표체계 부여에 관한 연구)

  • Park, Seung-Yong;Lee, Jae-Bin;Park, Woo-Jin;Yu, Ki-Yun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.281-288
    • /
    • 2009
  • In the paper, we try to develop the methodology for updating road networks of large-scale digital maps by using construction drawing data. For the purpose, it is pre-requite step to merge road networks detached in CAD drawing data. As such, tie points are identified in neighboring drawings and used for solving the parameters of 2D conformal transformation between drawings. Then, the merged road network in CAD data is transformed to the coordinate system of digital maps. In the process, IPs in the drawings are considered as control information and 2D affine transformation is selected for coordinate transformation. Through the experiments with real dataset, we can identify that the developed method is valid and generally applicable.

Separation Characteristics of Aqueous Isopropanol Solution by Pervaporation (투과증발에 의한 이소프로판올 수용액의 분리특성)

  • 이규일;김현진;김진환
    • Membrane Journal
    • /
    • v.6 no.1
    • /
    • pp.22-31
    • /
    • 1996
  • Pervaporation experiments of isopropanol-water mixtures through a polydimethytsiloxane(PDMS) membrane were carried out at 35$^{\circ}$C and the effect of isopropanol concentration on the separation characteristics was investigated. The total permeation rate showed the largest deviation from the ideal permeation rate at the isoprpanol volume fraction from 0.5 to 0.7, which resulted from the interaction effect between permeants. The plasticizing effect of isopropanol enhanced the permeation of water, while the existance of water resulted in the depression of isopropanol permeation. Both the permeation rate and the selectivity were predicted using Flory-Huggins thermodynamics and modified Maxwell-Stefan equation. The concentration-dependent diffusion coefficients were expressed by Vignes equation. The Flory-Huggins interaction parameter between isopropanol and water was calculated using excess Gibbs energy correlation and the interaction parameters between liquid and polymer membrane were determined by equilibrium swelling experiments. The predicted permeation rates were in accord with the experimental ones within maximum error range of 35 %. The predicted permeation selectivities were in good agreement with the experimental values.

  • PDF

Differentiation of mixed bacterial populations by modified gram stain (수정된 Gram 염색법에 의한 혼합세균 개체군의 분별 측정)

  • 장진경;임종락;정계효;한홍의
    • Korean Journal of Microbiology
    • /
    • v.25 no.3
    • /
    • pp.244-248
    • /
    • 1987
  • Attempts were made to enumerate the number of Gram positive and negative bacteria in the development of natural fermentation rapidly and simultaneously. A general Gram stain was applied to this study. The number of cells by Gram stain was proportional to the cell turbidity by spectrophotometer within a range of 0.7 absorbance at 610nm. The cells washed out during procedures were not exceeded about 8 percentage. The standard error of separate counts in the mixture of Cscherichia coli and Micrococcus luteus was $5.1\pm2.3$%. The possible range of counting was $5.5\times 10^{7}-1.0\times 10^{9}$ cells/ml. Therefore, it is believed that a general Gram stain could be applied to the separate counting of mixture of Fram positive and negative bacterial populations too. In practice, growth kinetics of hemp retting and Kimchi fermentation were presented.

  • PDF

Development of chemical ionization method in a GC-TOF mass spectrometer for accurate mass and isotope ratio measurement (Accurate mass 및 isotope ratio 측정을 위한 GC-TOF 질량분석기에서의 화학적 이온화방법)

  • Chung, Joo-Hee;Na, Yun-Cheol;Hwang, Geum-Sook;Shin, Jeoung-Hwa;Ahn, Yun-Gyong
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2011
  • An accurate mass and isotope ratio were determined using a gas chromatography/time of flight mass spectrometer in CI positive mode for the identification of unknown metabolites. High mass tune was used to improve the ion intensity of $[M+H]^+$. Chromatographic resolution and dynamic range enhancement were performed to obtain more reliable accurate masses and correct isotope abundance ratios. Average absolute errors of mass and isotope ratios for 24 reference metabolite -TMS (trimethylsilyl) derivatives were 6.8 ppm, 1.5% of (M+1/M ratio) and 1.7% of (M+2/M ratio), respectively. The correct formulas of twenty one compound were retrieved within top-2 hit from the heuristic algorithm for elemental composition using each accurate mass and isotope abundance ratio.

Image Restoration for Detecting Muras in TFT-LCD Panels (TFT-LCD 패널의 불량 검출을 위한 영상 복원)

  • Choi, Kyu-Nam;Yoo, Suk-I.
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.11
    • /
    • pp.953-960
    • /
    • 2007
  • To correctly detect muras, visual defects in TFT-LCD panels, image distortion occurring on the profess of capturing panels should be corrected. In general vision systems, there are several known methods to restore the observed image. However, the vignetting effect particularly shown only in panel images cannot be easily restored through traditional methods because it is combined with background non-uniformity due to the unique characteristic of panel. To increase the reliability of image restoration, the vignetting effect should be properly corrected after being separated from image background. Therefore, in this paper we present a new method to analyze and correct the vignetting effect of panel images using principal component analysis. Experimental results for a total of 175 test images showed that the average contrast error of the muras in the distorted images was reduced from 37% to 11% and the mura misidentification rate was decreased from 14.8% to 2.2% by image restoration.

Comparative Analysis of Infiltration for Estimating Subsurface Runoff (지표하유출 산정을 위한 침투량의 비교분석)

  • Lee, Jae-Joon;Lee, Sung-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.540-540
    • /
    • 2012
  • 강우 발생시 유역에 집수된 물이 하천에 이르는 경로에 따른 유출은 지표유출, 지표하유출, 지하수유출로 구분된다. 정확한 수문순환 과정의 해석을 위해서는 지표 흐름뿐만 아니라 지표하 및 지하수 흐름의 해석이 중요한 실정이나 일반적으로 실무에서 사용되는 강우-유출해석 모형은 지표유출을 해석하기 위한 모형이 대부분이며, 지표하 유출과 침투량을 산정하는데 어려움이 있다. 일반적인 강우-유출해석 모형은 Horton 방법, NRCS 방법, Green-Ampt 방법에 의해 유효우량을 분리하며, 이 과정은 침투량을 직접적으로 모형화 할 수 없으므로 지표 및 지표하, 지하수 흐름을 복합적으로 해석할 수 있는 모형이 질적이나 양적으로 부족한 실정이다. 이러한 지표하 흐름과 침투량을 산정하기 위하여 FE-FLOW, PM, MS-VMS, GMS, GW-VISTAS, ARGUS 및 MODFLOW와 같은 지하수 모형을 사용하고 있다. 본 연구에서는 지표하유출 산정을 위한 침투량의 비교분석을 위해 현재 가장 범용되는 지하수 유동 모델링 프로그램인 Visual Modlfow 모형과 GMS 모형을 이용하여 침투량 산정을 위한 수치 모의를 진행하였다. 각 모형의 입력자료는 2009년 국립방재연구원에서 수행한 침투실험시설 자료를 이용하여 동일한 조건을 부여하고, 두 모형의 비교를 위해 Visual Modflow에서는 MODFLOW의 기본 해석방법인 유한차분법(FDM)을 이용하고, GMS 모형에서는 3차원 유한요소해석이 가능한 GMS-FEMWATER를 이용하였다. 두 모형의 수치모의 조건으로 2009년 국립방재연구원에서 수행한 침투실험방법과 동일하게 공극률에 따른 투수성 보도블럭의 구분과 50mm/hr, 100mm/hr, 150mm/hr, 200mm/hr의 강우강도별 선행함수조건에 따른 수치모의를 진행하였으며, 수치모의된 침투량의 적정성을 판단하기 위하여 국립방재연구원의 침투실험 결과자료와 비교분석하였다. 침투실험 자료와 각각 수치모의된 침투량을 비교분석한 결과 서로 유사한 경향을 보이고 있으나 초기 침투시 상대오차가 비교적 크게 발생하였다. 이는 수치모형의 경우 수리실험과는 다르게 모의시작과 동시에 해당 강우강도의 침투가 시작되므로 초기 유입 유출량 발생시간의 차이가 종료시간까지 누적 침투량에 미치는 것으로 판단되며, 매개변수에 많은 영향을 받는 것으로 판단된다.

  • PDF