수평관에서 R245fa의 응축 열전달계수 (Condensation Heat Transfer Coefficients of R245fa on a Plain Tube)

  • 심윤보;박기정;정동수;김종성
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.555-562
    • /
    • 2007
  • In this study, condensation heat transfer coefficients (HTCs) of R22, R134a, R245fa and R123 are measured on a horizontal plain tube. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling temperature $3-8^{\circ}C$. Test results show the HTCs of newly developed alternative low vapor pressure refrigerant, R245fa, on a plain tube are 9.5% higher than those of R123 while they are 3.3% and 5.6% lower than those of R134a and R22 respectively. Nusselt's prediction equation for a plain tube underpredicts the data by 13.7% for all refrigerants while a modified equation yielded 5.9% deviation against all data. From the view point of environmental safety and condensation heat transfer, R245fa is a long term good candidate to replace R123 used in centrifugal chillers.

HFC-404a와 Polyol ester 오일 혼합물의 증기압 측정 (Measurement of Vapor Pressure of HFC-404a and Polyol ester Mixture System)

  • 박영무;김락현
    • 에너지공학
    • /
    • 제18권3호
    • /
    • pp.203-211
    • /
    • 2009
  • 기존의 CFC 계열 및 HCFC 계열 냉매들이 오존층 붕괴와 지구온난화의 원인들 중의 한가지로 밝혀지면서 이것을 대체할 수 있는 냉매의 개발은 주요한 연구과제였다. 이제 몇 가지 대체 냉매들이 개발되면서 이것들 이 냉동시스템에 사용될 때 발생하는 상용성 (Compatibility)이 연구될 필요가 있다. 본 연구에서는 대체냉매의 상용성 연구의 일환으로 1,1,1,2-Tetrafluoroethane(HFC-134a) +1,1,1-Trifluoroetane(HFC-143a) + Pentafluoroethane (HFC-125)의 혼합대체냉매 HFC-404a 와 냉매 윤활유의 하나인 POE 오일 혼합물의 증기압을 측정하였다. 측정온도범위는 냉매 시스템의 운전온도를 고려하여, 263.15K 에서 323.15 K로 하였으며 오일농도범위는 0 mass% 에서 90 mass% 까지로 하였다. 측정결과 273.15K 이하의 온도에서 오일 농도 30 mass%까지 증기압에 대한 오일의 영향은 미미하였으며 50 mass% 이상에서는 증기압이 급격히 떨어지는 것이 밝혀졌다. 측정자료를 이용하여 HFC-404a와 POE 오일 혼합물의 증기압을 예측할 수 있는 모형을 개발 하기 위하여 Rault 모델과 Flory-Huggins 모델을 사용하여 측정치와 비교하였다. 그리고 보다 정확하고 실용적으로 증기압을 예측할 수 있는 경험식을 도출하였다.

R435A를 적용한 정수기 냉동시스템의 성능평가 (Performance Evaluation of R435A on Refrigeration System of Water Purifiers)

  • 이요한;강동규;최현주;정동수
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.15-23
    • /
    • 2013
  • In this study, thermodynamic performance of R435A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 20%R152a/80%RE170 using actual domestic water purifiers. This mixture is numbered and listed as R435A by ASHRAE recently. Test results show that the system performance with R435A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R435A is 11.8% lower than that of HFC134a. The compressor discharge temperature of R435A $8^{\circ}C$ lower than that of HFC134a at the optimum charge. Overall, R435A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

대체냉매 R430A를 적용한 정수기 냉동시스템의 성능 평가 (Performance of R430A on Refrigeration System of Domestic Water Purifiers)

  • 박기정;이요한;정동수;김경기
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.109-117
    • /
    • 2009
  • In this study, thermodynamic performance of R430A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 76%R152a124% R600a using actual domestic water purifiers. This mixture is numbered and listed as R430A by ASHRAE recently. Test results show that the system performance with R430A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R430A is 13.4% lower than that of HFC 134a. The compressor dome and discharge temperatures and condenser center temperature of R430A are very similar to those of HFC134a at the optimum charge. Overall, R430A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

자외선이 해조류에 미치는 영향에 관한 고찰 (Overview of UV-B Effects on Marine Algae)

  • 한태준
    • 환경생물
    • /
    • 제17권1호
    • /
    • pp.1-9
    • /
    • 1999
  • 산업활동의 부산물인 chlorofluorocarbons(CFCs)와 같은 물질들의 대기권 유입으로 오존층의 파괴가 극심해짐에 따라 자외선의 지표유입량이 증가되는 추세를 보이는데, 특히 중파자외선의 증가는 DNA, 단백질, 지질 등에 의한 흡수를 통하여 생물학적 폐해를 야기할 수 있다는 점에서 주목된다. 최근 측정 결과 우리나라 동해안에서 해수표면에 도달되는 중파자외선 광량의 1%가 수심 l0 m까지 침투하는 것으로 나타났는데, 이는 해양생태계 생산성의 대부분이 해양 수심의 상위 2.5%에 해당되는 투광대에 의존한다는 점을 감안할 때 자외선에 의한 막대한 생태학적 폐해를 예견하게 해준다. 실내배양실험 연구에서 중파자외선은 대형해조류의 생장 및 광합성을 억제하고 광합성 색소를 파괴하는 등의 생물독성학적 효과를 보였다. 반면, 자외선의 피해로부터 해조류를 보호해 주는 몇 가지 기작이 밝혀진 바 있는데, 어린시기의 갈조류 다시마는 청색광에 의한 광재활성화 능력을 함유한 것으로 보이고, 한국산 녹조 구멍갈파래와 홍조 도박류에서는 자외선을 강하게 차단하는 흡수물질이 형성됨을 알 수 있었다. 그러나 이러한 적응기능들이 해조류에서 보편적으로 나타나는 것인지에 대해서는 좀 더 연구가 필요하다. 해양생태계는 대기 중 CO$x_2$를 이용하여 1년에 약 100 Gt의 유기물질을 생산해내고, 인류가 소비하는 식품의 30%를 제공한다는 점에서 자외선에 의한 생물량의 감소는 해조류 뿐만 아니라 먹이망에 의해서 복잡한 연결구조를 지닌 생태계 전체의 붕괴를 야기할 수 있는 심각한 사안이라고 할 수 있다. 따라서, 자외선에 대한 피해를 연구 평가하여 전략을 세우고 이를 예측하는 예보시스템을 개발할 필요성이 절실히 부각된다.