• 제목/요약/키워드: 오일 디플렉터

검색결과 3건 처리시간 0.019초

화력발전소에 사용되는 개선된 오일 디플렉터 개발 (Development of an Advanced Oil Deflector Used in Thermoelectric Power Plant)

  • 최용훈;곽효서;이창렬;김철
    • 한국정밀공학회지
    • /
    • 제33권8호
    • /
    • pp.661-668
    • /
    • 2016
  • Oil deflector prevents oil leakage that occurs in thermoelectric power plant at operating lubricant facilities. Vibration of rotating rotor-induced wear of aluminum tooth in existing oil deflector leads to oil leakage as well as life shortening of the tooth. In this study, an advanced oil deflector was developed for shock absorption and prevention of wear by decreasing clearance (from 0.5 mm to 0.2 mm) between rotor and tooth to minimize oil leakage, and by replacing 2 aluminum teeth in outmost of the oil deflector with hi-performance seal made of engineering plastic. The CFD results were compared between advanced vs. existing oil deflector to determine the amount of oil loss. Structural safety was verified through impact analyses according to the three kinds of engineering plastics, considering cost efficiency, and optimal material of hi-performance seal was chosen.

발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 간헐적 고진동 현상 규명 (Examination of the Intermittent High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant)

  • 양승헌;박철현;김재실;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.190-195
    • /
    • 2002
  • The intermittent high vibration has been occurred one or two times a day for a 500MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the intermittent high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.

  • PDF

발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 주기적 고진동 현상 규명 (Examination of the Periodic High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant)

  • 양승헌;박철현;김재실;하현천
    • 한국소음진동공학회논문집
    • /
    • 제12권11호
    • /
    • pp.897-903
    • /
    • 2002
  • The periodic high vibration has been occurred one or two times a day for a 500 MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the periodic high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.