• Title/Summary/Keyword: 오염지반

Search Result 411, Processing Time 0.02 seconds

A Study on the Correlation between River Contamination Level and Ground Pollution Source through Korean Case Study (국내 사례분석을 통한 하천오염도와 지반오염원의 상관관계에 관한 연구)

  • Choi, Joohwan;Song, Wonjun;Lee, Junhwan
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.1
    • /
    • pp.51-60
    • /
    • 2010
  • This study measured for comparison and analysis the correlation of River pollution and Soil contamination, based on the results of previous research, and then in order to increase the efficiency of study, heavy metals which cause serious side effects was limited to the case among pollutants. This study focused on the rivers that near the Urban and industrial districts, for example, Nak-Dong river, An-Yang river, Tae-Hwa river and the rivers that near the farm land or pasture, for example, Yeong-San river, Mi-Ho river, then compare and analyze the degree of actual pollution as gathered the results of Previous research. Correlationship about pollutants of river near the Urban, industrial area and drainage basin its river has been proven, and this expected because of the strong influence by point pollution source. On the other hand, I can found the opposite relationship where the river near the farm land or pasture, and this probably because of the influence by nonpoint pollution source.

  • PDF

유전율을 이용한 토양오염 모니터링 기법의 제안

  • 김만일;김형수;정교철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.104-107
    • /
    • 2004
  • 지반오염을 조사하기 위해서는 시추작업을 통하여 시료를 채취하는 방법이 일반적이지만, 실시간으로 원위치에서 다양한 오염물질들의 오염도 변화를 체계적으로 모니터링하는 것은 대단히 어렵다. 본 연구에서는 Frequency Domain Reflectometry(FDR) 장비를 고안하여 지반의 유류오염을 파악하기 위한 유전율 측정법의 실험적 접근을 시도하였다. 구체적으로 포화 및 불포화 매질에 대한 오염도의 측정 및 오염도와 체적함수비의 관계를 측정하여 유전율 반응으로부터 매질의 물성치를 파악할 수 있는 것을 확인하였다.

  • PDF

A Study on the Determination of Bearing Capacity of Polluted Soils with Various Concentrations (농도가 다른 오염지반의 지지력 결정에 관한 연구)

  • 안종필;박상범
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.6
    • /
    • pp.57-69
    • /
    • 1999
  • This study investigates the existing theoretical backgrounds for bearing capacity determination according to the plasticity of soils when unsymmetrical surcharge is loaded on polluted soft soils. It also investigates the behavior of the displacement and bearing capacity by unsymmetrical surcharge on the Polluted soft soils. by comparing the analytical results and the actual measurements performed through the model test. Model tests were carried out as follows : soil tank, bearing frame and bearing plate are made for the test ; the water content in soil tank was kept constant while the contaminants in natural soils and polluted material were gradually increased ; unsymmetrical surcharge is increased at regular intervals and then the amounts of settlement, lateral displacement and upheaval are observed. In conclusion, the value of critical surcharge was expressed as $q_{ cr}= 2.78_{Cu}$ which was similar to those $Tschebotarioff(q_{cr}=3.0_{Cu)$ and $Meyerhof(q_{cr}=(B/2H+\pi/2_{Cu})$ had proposed. The value of ultimate capacity was expressed as $q_{ult}=4.84_{Cu}$ which was similar to that of Prandtl.

  • PDF

Mechanical Properties of Oil Pollution Sand Due to Changes in the Viscosity of Oil (점도 변화에 따른 유류오염 모래의 역학적 특성)

  • Hong, Seung Seo;Bae, Gu-Jin;Kim, YoungSeok
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.577-585
    • /
    • 2015
  • Contamination of soil due to an oil spill influences its subsequent behavior. An investigation was conducted to study the effect of oil viscosity on compaction characteristics, coefficient of permeability, and shear strength. Water permeability was also determined by using Kerosene, Engine oil, and Crude-oil as contaminants. The test results indicate that the compaction characteristics are influenced by oil contamination. Direct shear test was conducted to investigate the effect of oil in the pore space in sandy ground. angle of internal friction of sand (based on total stress condition) decreases due to presence of oil within the pore spaces in sand.

Removal of Heavy Metal and Organic Substance in Contaminated Soils by Electrokinetic and Ultrasonic Remediation (동전기 및 초음파 복원기술에 의한 오염지반내의 중금속 및 유기오염물질 제거)

  • Chung, Ha-Ik
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.3
    • /
    • pp.83-91
    • /
    • 2003
  • The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique to remove mainly organic substance in contaminated soil. In this study, the combined electrokinetic and ultrasonic remediation technique was studied far the removal of heavy metal and organic substance in contaminated soils. This study emphasized the coupled effects of electrokinetic and ultrasonic techniques on migration as well as remediation of contaminants in soils. The laboratory soil flushing tests combining electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of both of these techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.