• Title/Summary/Keyword: 오염배출부하

Search Result 266, Processing Time 0.02 seconds

Distribution Characteristics of Polycyclic Aromatic Hydrocarbons(PAHs) in Riverine Waters of Ulsan Coast, Korea (울산연안 하천에서 다환방향족탄화수소 분포특성)

  • You, Young-Seok;Lee, Jeong-Hoon;Park, Jeong-Chae;Kim, Dong-Myung;Cho, Hyeon-Seo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.398-405
    • /
    • 2012
  • PAHs(Polycyclic Aromatic Hydrocarbons) in coastal area and estuary adjacent to urban area and industrial activities region are mainly introduced into marine environment via atmosphere and river. This study which is evaluated the distribution characteristics of PAHs discharge from rivers and sewage disposal water which flowing into Ulsan bay, and were carried out in Jun of dry season and in Auguest of wet season, 2008. The water samples from eight main rivers and Youngyeon WWTP(Wastewater Treatment Plant) flowed into Ulsan bay were taken for analysis of dissolved PAHs. The range and mean values of dissolved PAHs concentrations showed 10.30 to 87.88 ng/L, its mean 36.94 ng/L in dry season and 10.30 to 69.57 ng/L, its mean 24.37 ng/L in wet season. The distribution of dissolved PAHs showd the high concentrations in the Gungcheoncheon which is flowed from urban and industrial area. The ranges and means values of the loading fluxes were estimated with 0.04 to 8.27 g/day, its mean 2.05 g/day in dry season, and 0.03 to 4.77 g/day, its mean 1.61 g/day, in wet season. The loading flux showed the highest value in Taewha river due to the high flow rate and the urban activity. The composition patterns of dissolved PAHs compound showed most of the trend occupying low molecuar weight PAHs than high molecular weight PAHs. These results were due to physical and chemical characteristics of PAHs compound, and were similar to those of other studies. The concentrations of dissolved PAHs in this study are lower than those of other studies, and the level of PAHs pollution appeared to be not serious in reverine waters of Ulsan coast.

Assessment of Technology Based Industrial Wastewater Effluent Limitation and Standards for the Application of Domestic Industries (II) : Analysis Pollution Loads Contribution by Risk Assessment Indicator in Industrial Wastewater (처리기술에 근거한 산업폐수 배출허용기준 국내 적용성 연구(II) : 산업폐수 위해성 지표를 이용한 오염부하 기여도 분석)

  • Kim, Kyeongjin;Kim, Wongi;Jung, Sanggu;Jung, Jinyoung;Kim, Jaehun;Kim, Sanghun;Yeom, Icktae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.191-199
    • /
    • 2010
  • Introduction of Technology-Based Effluent Limitations (TBELs) concepts into Korea requires extensive and through analyses on the expected pollutants reduction effects and the cost factor for the industry side. In addition, the TEBLs should be optimized for the regulatory environments of Korea and be applied in a progressive manner to minimize the undesirable effects. It is also necessary to assess the contribution of each industrial categories's to the pollution of natural water bodies to find the priority of TEBLs application. For these purposes, the pollution loads of various industrial categories were analyzed using risk assessment indicator based on Toxic Weighting Factors (TWFs). First, the TWFs were calculated for the pollutants regulated using the method adopted by USEPA. And the effluent characteristics of the eighty two categories of industry in Korea were investigated. Although the analytical data on the wastewater from different industrial categories are relatively limited, the results from two previous studies were used. The first study, conducted by the National Institute of Environmental Research in 2001~2004, investigated the wastewater characteristics from 255 industrial sources covering the major 20 industrial categories. The second study includes more recent analytical data for the wastewater from 500 industrial sources, covering all the 82 industrial categories. In the result of the pollution loads analyses, the category of 'Synthetic and Chemical manufacture' was found to show the highest raw pollution load. On the other hand the category of 'Ion & Steel manufacture' was found to show the highest effluent pollution loads, which can be considered as the real impacts on natural water streams. The top five categories occupied 62.2% of the total effluent pollution loads. Through the analyses, the relative importances of each industrial categories and the priorities of TEBL-based pollution reduction were determined.

Emission Characteristics of Volatile Organic Compounds from Air Fresher using Small Emission Chamber (소형방출챔버를 이용한 방향제의 휘발성 유기화합물 방출특성에 관한 연구)

  • Jung, Young-Rim;Park, Hyun-Hee;Oh, Youn-Hee;Kim, Soon-Geun;Sohn, Jong-Ryeul;Kim, Sun-Hwa;Yu, Young-Jae;Bae, Gwi-Nam;Kim, Man-Goo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.183-190
    • /
    • 2011
  • This study investigated the emissions characteristics of air freshener using small emission chamber method. The emission of VOCs from air freshener were determined in the small chambers in the temperature (25, $30({\pm}1)^{\circ}C$), relative humidity ($50{\pm}5%$), ventilation rate (0.3, 0.5, ($0.8({\pm}0.005)/hr$), and sample loading factor ($1.4{\sim}551.0g/m^2$) in this study. The emission tests from air freshener for sample loading factor resulted in TVOC emission rates of $0.7{\sim}64.4mg/m^2{\cdot}h$ after 5 hours. For most target VOCs such as limonene, ${\alpha}$-pinene and linalool, higher temperature and ventilation rate levels exhibited increased emission rates.

Improvement Measures of Pollutants Unit-Loads Estimation for Paddy Fields (논으로부터 배출되는 영양물질 오염부하량 원단위 산정 방법 개선 방안 검토)

  • Jung, Jae-Woon;Yoon, Kwang-Sik;Choi, Woo-Jung;Choi, Woo-Young;Joo, Seuk-Hun;Lim, Sang-Sun;Kwak, Jin-Hyeob;Lee, Soo-Hyung;Kim, Dong-Ho;Chang, Nam-Ik
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.291-296
    • /
    • 2008
  • Pollutant unit load developed by Ministry of Environment (MOE) in 1995 has been a tool commonly used for water quality management and environmental policy decision. In spite of the convenience of the method in application, the shortcoming of the method has been criticized especially for nonpoint source pollution from paddy field. In this paper the estimation procedures of pollutant unit load from paddy field in the major river basins (Han, Nakdong, Geum, and Youngsan river) were investigated, and some suggestions of improvement measures of the unit-load estimation were made. The investigation showed that the distributions of rainfall, run-off, and run-off ratio, which are the most important factors affecting discharge amount of pollutants, were not similar among river basins. Such differences seemed to result in a greater unit loads estimation at Han river and at Nakdong river watersheds compared to the others. Therefore, it is not likely to be rationale to compare unit load among the watersheds without consideration of such differences. We conclude that estimation of unit-load through an intensive monitoring of pollutant discharge is crucial for better estimation of unit-load. When such an intensive monitoring is not easy due to labor and expense restriction, we suggest that unit-load should be estimated based on the storm-events which is a representative rainfall-runoff event of the area.

Filtration characteristic of quantity of coagulant and variable pressure (응집제의 주입량 및 압력변화에 따른 여과특성)

  • Lee, Sung-ho;Lim, Taek-jun;Cho, Jun-hyung
    • Journal of Forest and Environmental Science
    • /
    • v.17 no.1
    • /
    • pp.29-36
    • /
    • 2001
  • Compared to other industries, pulp and paper industry use a lot of water. As a result, a large amount of the waste water is discharged in the pulp and paper industry. This study was investigated to prevent the environmental pollution terribly faced with our society nowadays. In the waste water of pulp and paper, there are so many things in the waste water, like fiber, filler, and other organic solvent etc. so we must remove them from our environment. This study was investigated to experiment on test of impressed filtration with the kind and quantity of coagulant and the variance of pressure. In this study, we used feds, alums. $CaCl_2$, polymer as a coagulant and these pressure was 49, 98, 147, 196kpa. According to this study, we measured the speed of filtration and turbidity, measuring filtrated water. According to the values, we know the fact that as the consistency of coagulant and pressure were high, the filtration was good.

  • PDF

A Study on the Demonstration of Yellow Plume Elimination System from Combined Cycle Power Plant Using Liquid Injection System (액상 직분사 시스템을 이용한 복합화력 황연제거 실증 연구)

  • Lee, Seung-Jae;Kim, Younghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.317-324
    • /
    • 2020
  • Combined cycle power plants (CCPP) that use natural gas as fuel are easier to start and stop, and have lower pollutant emissions, so their share of domestic power generation facilities is steadily increasing. However, CCPP have a high concentration of nitrogen dioxide (NO2) emission in the initial start-up and low-load operation region, which causes yellow plume and civil complaints. As a control technology, the yellow plume reduction system was developed and operated from the mid-2000s. However, this technology was unable to control the phenomenon due to insufficient preheating of the vaporization system for 10 to 20 minutes of the initial start-up. In this study, CFD analysis and demonstration tests were performed to derive a control technology by injecting a reducing agent directly into the gas turbine exhaust duct. CFD analysis was performed by classifying into 5 cases according to the exhaust gas condition. The RMS values of all cases were less than 15%, showing a good mixing. Based on this, the installation and testing of the demonstration facilities facilitated complete control of the yellow plume phenomenon in the initial start-up.

Environmental Impacts Assessment of ITO (Indium Tin Oxide) Using Material Life Cycle Assessment (물질전과정평가(MLCA)를 통한 투명전극 ITO (Indium Tin Oxide)의 환경성 평가)

  • Lee, Soo-Sun;Lee, Na-Ri;Kim, Kyeong-Il;Hong, Tae-Whan
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2012
  • In this study, we executed an environmental impact assessment about recycling of ITO (Indium Tin Oxide), used for touch panel. ITO is mainly used to make transparent conductive coatings for touch and flat screen LCD (Liquid Crystal Display), ELD (Emitting Light Device), PDP (Plasma Display Panel). This demand is increasing little by little. but form current status, ITO is discarded than recycling. It is important to recycling ITO for national strategies about resource conservation, and reduce environmental burden. Also Landfill or incineration of ITO cloud be harmful to the human health in the long-term. Material Life Cycle Assessment method (MLCA) was conducted for comparison landfill and recycling of ITO. MLCA would provide more information for environmental issues and potential environmental impacts of ITO. The study includes two scenarios, the basic scenario is recycling of ITO (10, 20, 30%) and the other scenario is landfill of ITO. In addition, amount of carbon dioxide and energy were calculated.

A Study on the Development of GIS Based Mitigation Scenario Support System Using QUAL2E Model for TMDL (TMDL 지원을 위한 QUAL2E 모델을 이용한 GIS기반의 삭감시나리오 작성 지원시스템 개발에 관한 연구)

  • Lee, Chol-Young;Kim, Kye-Hyun;Lee, Hyuk;Ryu, Kwang-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.177-188
    • /
    • 2012
  • This study was mainly focused on the development of GIS based decision support system to easily make mitigation scenarios and to conveniently simulate water quality for TMDL. The study area was the 31km section of upper Sapgyo stream in Geum river basin, and QUAL2E model was adopted. GIS DB was built through the collection of the data which includes point/non-point source attributes and various thematic maps. The amounts of discharged loads of BOD, T-N and T-P from unit watershed were estimated respectively. Finally, the system, which can operate water quality simulation through simply modifying their values, was developed. The hypothetical three mitigation scenarios were applied, thereby the most efficient mitigation scenario could be chosen by comparison of the results based on GIS. Therefore, it is expected that the developed system can facilitate the decision makers to select the best alternative through the analysis of the available BMPs. Also, it can be used to develop new scenarios using different methods and algorithms. In the future, more study need to be made to enhance its applicability in the perspective of developing mitigation scenarios through the management of individual pollutant sources and extending study areas.

Concentration Distribution of PCBs in Soil Around Industrial Complex and Relationship with PCBs Sources (공단지역 주변 토양 중 PCBs 농도분포 및 발생원 추정에 관한 연구)

  • Park, Seok-Un;Kim, Kyoung-Soo;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.521-527
    • /
    • 2007
  • To investigate the relationship between PCB sources and concentration level in soil, PCBs concentration of 8 soil samples around Shiwa industrial complex were measured. The concentration of PCBs in soil samples were ranged from 2.43 to 274 ng/g dry (0.116 to 60.5 pg WHO-TEQ/g dry) md off-gas were ranged from 48.6 to $2872ng/m^3(0.00150\sim15.2ng\;WHO-TEQ/m^3)$; these are similar levels with results of previous study in Korea. The homologue patterns in soil samples were varied from sample to sample, but isomer patterns were very similar with each other. The two principal components were extracted by Principal Component Analysis(PCA) of 8 soil samples and cumulative factor loading was 95.7%. As the result of PCA, it could be expected that PCBs in soil samples of this study were more affected by PCB products than combustion process and mostly affected by already-known sources.

Assessment of Water Quality in Pyeongtaek Reservoir and Its Main Tributaries (평택호와 유역 주요 하천의 수환경 및 오염도 평가)

  • Hwang, Soon-Jin;Cho, Kyung-Je;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.1 s.102
    • /
    • pp.38-47
    • /
    • 2003
  • The water quality of the Pyeongtaek Reservoir and its main streams has been eval uated far water pollution state in March, June, September and December,2000. The following are the findings: $NH_4$ accounts for the majority of TN in the inflow streams. In the reservoir, TN and $NH_4$ are the more present in the winter season and less in the summer season, with $1.6{\sim}2.4$ times of $NO_3$ and $5.3{\sim}11.4$ times of $NO_2$ found in December and June compared with other seasons. The concentration of each component is different between streams: $NH_4$ among inorganic nitrogen has the highest concentration in the upstream, and $NO_3$ is more prevalent in the downstream. SRP accounts for $25{\sim}69%$ of TP in the stream. Unlike N component, P component in the reservoir rapidly decreases from upstream toward downstream, except in the summer. Average SRSi slightly increases in the fall, i.e., immediately after rainfall. In the streams, the average concentration of chlorophyll-a ranges from 9 to $33{\mu}g/l$, and is relatively high in the downstream. In contrast, in the reservoir, it is the highest in the upstream where $NH_4$ and SRP are frequently found. In particular, diatom and cryptomonad algae are bloomed in March, and blue-green algae in September; their maximum values are $108{\mu}g/l$ and $130{\mu}g/l$, respectively. Considering the concentration of N and P nutrients, pollution loads can affect the Pyeongtaek Reservoir in the downstream in this order: Ansong Stream