• Title/Summary/Keyword: 오염물질 유출

Search Result 699, Processing Time 0.03 seconds

Application of Automatic Stormwater Monitoring System and SWMM Model for Estimation of Urban Pollutant Loading During Storm Events (빗물 자동모니터링장치와 SWMM 모델을 이용한 강우시 도시지역 오염부하량 예측에 관한 연구)

  • Seo, Dongil;Fang, Tiehu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.373-381
    • /
    • 2012
  • An automatic flow and water quality monitoring system was applied to estimate pollutant loads to an urban stream during storm events in DTV (Daeduk Techno Valley), Daejeon, Korea. The monitoring system consists of rainfall gage, ultrasonic water level meter, water quality sensors for DO, temperature, pH, conductivity, turbidity and automatic water sampler for further laboratory analysis. All data are transmitted through on-line system and the monitoring system is designed to be controlled manually in the field and remotely from laboratory computer. Flow rates were verified with field measurements during storm events and showed good agreements. Automatic sampler was used to collect real time samples and analyzed for BOD, COD, TN, TP, SS and other pollutant concentrations in the laboratory. SWMM (Storm Water Management Model) urban watershed model was applied and calibrated using the observed flow and water quality data for the study area. While flow modeling results showed good agreement for all events, water quality modeling results showed variable levels of agreement. These results indicate that current options in the SWMM model to predict pollutant build up and wash-off effects are not sufficient to satisfy modeling of all the rainfall events under study and thus need further modification. This study showed the automatic monitoring system can be used to provide data to assist further refinement of modeling accuracy. This automatic stormwater monitoring and modeling system can be used to develop basin scale water quality management strategies of urban streams in storm events.

Characteristics of Non-point Pollutant Discharge from Upper Watershed of Seomjin Dam during Rainy Season (섬진강댐 상류 유역의 강우시 비점오염물질 유출 특성)

  • Kwak, Dong-Heui;Yoo, Seung-Joon;Kim, Ji-Hoon;Lim, Ik-Hyun;Kwon, Ji-Young;Chung, Paul-Gene
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.39-48
    • /
    • 2008
  • This study was carried out to investigate the characteristics of the pollutant discharge from non-point source and to estimate the unit loads of the pollutant discharge from the upper watershed of Seomjin Dam during rainy season. The upper watershed of Seomjin Dam is located in the middle of Jeonbuk province is formed two tributaries mainly. A sub-branch stream of those tributaries is Imsil stream of which flow rate is about 13% of the main stream of Seomjin reservoir normally. On the basis of measurement result in this study, the water quality of Imsil stream was fluctuated highly and the quantity of measured pollutant discharge was higher than the value calculated with the proportion of flow rate during dry season. On the contrary, during rainy season the mean values of flow rate and water quality were higher than the quartile according to the statistical analysis. That means rainfall can influence strongly on the water quality of the upper watershed of Seomjin reservoir. Among the several criteria of water quality, SS discharge was most sensitive to the flow rate variation of stream, which was fluctuated in proportion of rainfall, basically. It was evaluated the event mean concentration (EMC) of non-point source pollutants depending on rainfall events as well. Though the pollutant discharge unit of Imsil stream was lower than the main stream of Seomjin reservoir, the EMC value of Imsil stream was higher than the main stream of Seomjin reservoir.

Water Treatment Using Constructed Wetlands and Research Perspectives in Korea (인공습지를 이용한 수처리 효율 및 향후 연구제언)

  • Gang, Ho-Jeong;Song, Geun-Ye
    • Journal of Wetlands Research
    • /
    • v.6 no.2
    • /
    • pp.57-63
    • /
    • 2004
  • More than 1000 natural and constructed wetlands have been used to improve water quality. The general results showed that the highest removal efficiency was 84% for BOD and the lowest one was 48% for total nitrogen concentration. In addition, total phosphous removal efficiency was 67%, and the removal efficiencies are related to inflow loading. Researches donducted in Korea have focused on input-output mass balance and uptake by aquatic plant. As such little information if available about complex processes regulating water quality and role of microbes. Therefore, to determine the optimal design for construct, and methods to operate constructed wetland, researches about complex mechanisms of contaminant removal and interdisciplinary researches are necessary.

  • PDF

Characteristics of Pollutant Loading into Streams from Flooded Paddies -On The Special Reference to Total Kjeldahl Nitorgen and Total phosphorous- (농경지로부터의 오염물질 유출부하특성 - 전Kjeldahl 질소 및 전인을 중심으로)

  • 홍성구;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.3
    • /
    • pp.93-102
    • /
    • 1989
  • With an objective to provide basic information for the management and the prediction of eutrophication in lentic water Systems, total amount of Kjeldahl nitrogen(T-N) and phosphorous(T-P) from irrigated water and drained water from flooded paddies were investigated during the rice growing period of 1988. A 29.3 ha paddies near Jungnam-myun, HwaSung-gun, Gyungi Province, Korea was instrumented for measuring runoff and sampling irrigated water and drained water from paddies. The following conclusions may be drawn from the result of this study. 1.During 115 days of investigation, T-N load for paddies was 362.6kg and T-P 63.44kg.These would be converted to 12.4kg T-N/ha and 2.17kg T-P/ha, respectively. 2.The T-N and T-P loadings in different periods showed a significant difference. The 25% of T-N loading was drained soon after fertilization period and 60% was drained during the rainy season from July 5 to July 24. 3.Annual loadings from paddies could be calculated to 30kg T-N/ha/year and 52kg T-P/ha/year considering non-measurement periods. 4.After the rainy season, the nutrient loads from drained water showed much less than those from irrigated water, and it may be suggested that the paddies would act as a stabilization pond. 5.The average concentrations of nutrients at 0.9km downstream from investigated paddies were 2.02(T-N) mg/l and 0.52(T-P) mg/I, which were 1.82(T-N) mg/l and 0.056(T-P)mg/l lower than those of drained water from paddies.

  • PDF

Loading Characteristics and Environmental Changes in Closed Coastal Water (폐쇄성 해역의 오염부하 특성과 해역환경변화)

  • Lee Chan-Won;Kwon Young-Tack;Yang Ki-Sup;Jang Pung-Guk;Han Sung-Dae
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.1 no.2
    • /
    • pp.60-70
    • /
    • 1998
  • Masan Bay is a typical enclosed coastal sea and receving body of discharges from Masan city and Changwon city. A POTW(Publicly Owned Treatment Works) started operation from November 1993 when the population of drainage area increased abcent 1.0 million and the effluent from this Plant has being discharged to the enclosed sea where is located at 15km distance from inner Masan Bay. Thus the inflow pattern to Masan Bay has been changed. The main objective of this research is to evaluate the relationship between urban wastewater discharge and water qualify change in a typical coastal zone. It is necessary a) to evaluate the change of input loadings, b) to determine the effect on water quality changes, and c) to find the respective importance of improvement options that must be controlled in the wastewater treatment plant. It was concluded that the sea water quality has being adversely affected by the discharge of insufficiently treated urban wastewater and the nutrient removal in wastewater treatment was very important and urgent.

  • PDF

Implementation of Sensor Controller and Monitering System Using Film Type (필름형 센서를 이용한 센서 제어기 및 모니터링 시스템 구현)

  • Park, No-Jin;Lee, Ho-Woong;Yu, Hong-Kyeun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • Leak detection, the system is controlled by humanity's precious water resources, prepare for natural disasters and prevent damage to buildings and various industrial facilities. Especially because it causes serious environmental pollution, chemicals or oil spills, leak detection of various liquid(oil, water), the point at which the liquid leak is detected early on, and minimize environmental pollution, prevent damage of the equipment due to the leak, and the country's precious water resources to be used safely. In this paper, we solve these problems by using specialized film sensor, any person who is not a skilled technician, equipment or walls anywhere can be easily installed. also reduce unnecessary circuit, If film sensor is connected to operate, have a big competitive price, the detection of liquid and the surrounding environment according to, the sensor film that can set the sensitivity control, and monitoring system was implemented.

Characteristics of the Pollutants Ronoff on the Tamjin A and B Watershed with Discharge Variation (유량변동에 따른 탐진 A와 B유역에서의 오염물질 유출 특성)

  • Park, Jinhwan;Lim, Byungjin;Jung, Jaewoon;Kim, Daeyoung;Oh, Taeyoun;Lee, Dongjin;Kim, Kapsoon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.917-925
    • /
    • 2012
  • In this study, we report the runoff characteristics of pollutants for Tamjin A and B watershed in Tamjin river basin using statistical analysis, such as correlation analysis and regression equation. Flow rate and water qualtiy data collected from 2 sampling sites(Tamjin A and B watershed) during 3 years(2009~2011) were analyzed for biochemical oxygen demand(BOD), total nitorgen(TN), total phosphorus(TP) and suspended solid(SS). The results showed that strong correlations were observed between flow rate and SS in Tamjin A, while weak correlations were observed among the BOD, TN, and TP. In Tamjin B, strong correlations were observed among the flow rate, SS and T-P except BOD and TP. Meanwhile, the values of $R^2$ for regression equations between flow rate and pollutants load were greater than 0.7. Results of these statistics indicated that there was a good agreement between flow rate and pollutants load. Also, the flow rate exponents of regression equations for BOD, TN, and TP were smaller than 1 in Tamjin A. In Tamjin B, flow rate exponents of regression equation for BOD and TP were smaller than 1. These results indicated that concentrations of BOD, TN, TP in Tamjin A and concentrations of BOD and TP were decreased as the flow rate was increased. This means that rater than nonpoint sources, point sources affect BOD, TN and TP in Tamjin A and BOD and TP in Tamjin B.

Characteristics of Pollutants Discharge from Hoengseong Watershed during the Dry and Rainy Seasons (횡성호 유역의 비강우시 및 강우시 오염물질 유출특성)

  • Roh, Sung-Duk;Kim, Jang-Hyun;Lee, Dae-Keun;Kim, Seon-Joo;Sohn, Byeong-Yong;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.695-705
    • /
    • 2006
  • This study was carried out to make a basic information for establishment of countermeasures against water pollution of Hoengseong watershed, accordingly we investigated the characteristics of pollutants discharge and estimated the unit loads from Hoengseong watershed. Seven sites (S1~S7) were selected for sampling and samples were taken 4 times during the dry and rainy seasons, respectively. During rainfall events, measured site mean concentration (SMC) ranges of $BOD_5$, $COD_{Mn}$, TOC, SS, Turbidity, T-N and T-P were 0.8~1.3 mg/L, 2.3~6.3 mg/L, 1.284~2.110 mg/L, 3.4~69.3 mg/L, 2.36~52.68 NTU, 1.243~1.669 mg/L and 0.025~0.070 mg/L, respectively. And the calculated annual unit loads of $BOD_{5}$, $COD_{Mn}$, SS, T-N and T-P in Hoengseong watershed were 1.327 kg/ha/yr, 7.349 kg/ha/yr, 87.075 kg/ha/yr, 1.848 kg/ha/yr and 0.103 kg/ha/yr, respectively. It was difficult to directly compare the unit loads proposed in this study with the estimated existing those. Because the unit loads in this paper were estimated not by land use types, but by complex land use of non-urban area. From the survey results, they showed that the unit loads in Hoengseong watershed were similar to those exisiting in the forest area, and showed lower than those existing in the paddy/dry field.

Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system (합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석)

  • Park, Jin-Kyu;Lee, Nam-Hoon;Kim, Hae-Ryong;Lee, Woong;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.

Determination of Pollutant Unit Loads from Various Transportation Landuses (교통관련 포장지역 비점오염원에서의 오염물질 유출원단위 산정)

  • Lee, So-Young;Lee, Eunju;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.543-549
    • /
    • 2008
  • Human activities and land-use practices are intensely widening the urban areas. High impervious surface areas cover much of urban landscapes and are the primary pollutant sources which can lead to water quality and habitat degradation in its watershed. As the urban areas expand, transportation land-use such as parking lots, roads, service areas, toll-gates in highways and bridges also increase. These land-uses are significant in urban pollution due to high imperviousness rate and vehicular activities. To regulate the environmental impacts and to improve the water quality of rivers and lakes, the Ministry of Environment (MOE) in Korea developed the Total Pollution Load Management System (TPLMS) program. The main objective is to lead the watershed for a low impact development. On a local scale, some urban land surfaces can be emitting more pollution than others. Consequently, in urban areas, the unit loads are commonly employed to estimate total pollutant loadings emitted from various land-uses including residential, commercial, industrial, transportation, open lands such as parks and golf courses, and other developed land like parking areas as a result of development. In this research, unit pollutant loads derived specifically from transportation land-uses (i.e. branched out from urban areas) will be provided. Monitoring was conducted over 56 storm events at nine monitoring locations during three years. Results for the unit pollutant loads of transportation land-use are determined to be $399.5kg/km^2-day$ for TSS, $12.3kg/km^2-day$ for TN and $2.46kg/km^2-day$ for TP. The values are higher than those of urban areas in Korean MOE and US highways. These results can be used by MOE to separate the pollutant unit load of transportation landuses from urban areas.