• Title/Summary/Keyword: 오염물질 유출

Search Result 700, Processing Time 0.031 seconds

Runoff Characteristics of Non-Point Source Pollution in Lower Reaches of Livestock Area (축사 주변지역 비점오염물질의 유출특성)

  • Hwang, Jeong-Suk;Park, Young-Ki;Won, Chan-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.557-565
    • /
    • 2012
  • In this research, it was analyzed that the effect of the non-point source pollution that occurs in the lower reaches of the livestock area. The analysis on the hydro- and polluto-graphs showed that the concentration of pollution gradually increased as the flow rate increased and, after reaching the peak flow rate, the flow rate dropped drastically. For Event Mean Concentration (EMC), in the lower reaches of livestock area, TSS EMC was 146.80~424.95 mg/L, COD EMC 11.64~55.66 mg/L, BOD EMC 6.66~49.88 mg/L, T-N EMC 7.650~43.825 mg/L and T-P EMC 0.711~3.855 mg/L. According to the results of the analysis on the correlations between pollutants, TSS and BOD, COD, T-N and T-P had correlations at a 0.53~0.95 confidence level. In addition, according to the result of the analysis on the correlations between EMC (mg/L) and storm runoff ($m^3$), the correlation was well explained by a Cubic regression. In addition, among the determination coefficients, TSS and T-N were relatively high, at 0.767~0.835 and 0.773~0.901 respectively, which indicates that EMC goes up as the storm runoff increases. Therefore, it is expected that EMC can be forecasted according to the amount of runoff ($m^3$). The results of this research will be a practical information for the assessment of the non-point source pollution that occurs in the lower reaches of the livestock area.

Characteristics of Non-Point Pollutants from Forest Landuse (산림 지역의 비점오염물질 유출 특성)

  • Kim, Ji-Yeon;Kim, Jee-Hyun;Jung, Min-Kyoung;Ji, Yong-Dea;Hwang, Jae-Yup;Park, Soo-Young;Yu, Jay-Jung;Kim, Tae-Seung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.287-287
    • /
    • 2011
  • 모니터링 자료의 부족으로 인하여 다양한 토지이용에서 발생하는 비점오염물질의 관리에 어려움을 겪고 있는 실정이다. 현재 환경부에서는 현행 토지계의 원단위를 세부적으로 분류하여 재산정하기 위하여 지목별로 장기 모니터링이 수행되고 있다. 특히, 산림 지역의 경우 도시 및 축산지역에 비하여 강우유출수의 농도는 낮더라도 유량적인 측면에 보았을 때 전체 수계에 대한 부하량 기여도는 매우 높다고 볼 수 있다. 따라서 본 연구는 장기모니터링의 일환으로 산림지역에 대한 비점오염물질 유출 특성을 파악하기 위하여 모니터링 및 분석을 실시하였으며, 이러한 결과는 향후 비점오염원 평가기반을 마련하고자 한다. 본 연구는 활엽수지역을 대상으로 2010년 4월부터 10월까지 총 16회에 걸쳐 모니터링이 수행되었으며, 시료의 성분 변화를 막기 위해 냉장기능이 있는 자동채수기를 이용하여 시료를 채취하였다. 수질분석항목은 BOD, COD, DOC, SS, T-N, $NO_3$-N, $NH_3$-N, T-P, $PO_4$-P로 총 9가지 항목을 분석하였다. 강우사상에 대한 모니터링 결과, 총강우량은 7.0~76.5mm, 강우지속시간은 1~30hr, 평균 강우강도는 0.88~18.50mm/hr의 범위를 보이고 있으며, EMC(Event Mean Concentration, 유량가중평균농도)결과 BOD는 0.4~2.4mg/L, T-N은 1.156~14.777mg/L, T-P는 0.009~0.562mg/L인 것으로 나타났으며, SS는 1.8~71.9mg/L 로 비교적 높은 값을 나타내는 것으로 분석되었다. 농도 변화 및 유출경향의 패턴을 볼 때, 유량이 증가함에 따라 농도도 점점 증가하여 첨두유량이 발생된 후 감소하는 경향을 나타내는 것으로 분석되었다. 또한 우리나라의 경우, 시험유역을 대개 산지 소유역에 설치하는 경우가 많아서 일반적으로 지연시간이 짧은 경우가 많기 때문에 이 지역 역시 강우가 내린 후 계류유출량의 증가에 영향을 주는 강우의 유출속도는 비교적 빠른 것으로 나타났다. 그리고 단기 수문곡선상에서 강우량이 많을 시 유출이 빠르게 일어나 첨두 유량에 도달하는 시간이 짧고, 강우량이 적을 시에는 첨두 유량의 출현시간이 늦어지는 것을 볼 수 있었다.

  • PDF

Establishing a Integrated Water Quality Management System for Coastal Area (연안역 수질정보통합관리시스템 구축에 관한 연구)

  • 황의호;김계현;전대수
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.307-312
    • /
    • 2003
  • 해양과 인접해 있는 연안역은 오염물질이 집중적으로 배출되는 곳으로 수질 및 환경오염이 문제시되고 있는 지역이다. 계속적인 연안역 수질악화를 막기 위해서는 광범위한 지역으로부터 배출되는 대량의 오염원 데이터와 환경정보를 효율적으로 관리할 수 있는 GIS기반의 수질정보통합관리시스템이 필수적이다. 이에 따라 본 연구에서는 연안역의 점ㆍ비점오염원 자료, 수질측정자료, 생태자료 등을 구축하고, 구축된 오염원 데이터를 바탕으로 원단위를 이용한 오염부하산정시스템을 구축함으로써 연안역 수질정보를 통합관리 할 수 있는 시스템을 개발하였다. 오염부하량 산정은 가지야마 수식모델을 이용하여 유출량을 산정, 원단위를 이용한 발생 및 배출부하 산정, 유달율을 고려한 유달부하량 및 유입농도 산정을 포함한다. 오염부하량 산정시스템은 사용자의 오염원 DB의 갱신에 따라 오염부하산정에 즉시 반영되도록 설계하였다. 나아가 효율적인 결과분석 체계 지원을 위하여 GIS를 이용한 오염부하량을 색의 농도차를 이용 도식하여 전체유역에 대한 임의지점에 발생하는 오염원 규모 및 유출 특성을 한눈에 조회가 가능하도록 함으로써 편리성을 제공할 수 있도록 하였다. 이러한 연안역 수질정보통합관리시스템은 수질관리에 있어 오염원자료의 유출과정의 해석을 통해 유역내 효율적인 오염원자료의 관리방안을 수립할 수 있도록 지원이 가능하며, 연안역으로 유입되는 오염량의 예측을 통하여 친환경 대안 제시를 위한 수질관리방안의 기초자료로 활용할 수 있을 것으로 사료된다.

  • PDF

EMC and Unit Loads of Pollutants Generated from Tomato Cultivation during Rainfall (강우시 시설재배지역의 오염물질 유출 EMC 및 원단위 산정)

  • Jeon, Je Chan;Kwon, Koo Ho;Lee, Sang Hyeub;Lee, Jea Woon;Gwon, Heun Gag;Min, Kyung Sok
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.555-566
    • /
    • 2013
  • Total maximum daily load enforced in 2004 is a program to evaluate the amount of pollutants by each land use type and manage to meet a target water quality of each waterbody. The many research to calculate runoff load of pollutants by landuse type have been studied. This study was conducted to calculate pollutants EMC, load and unit load in stormwater runoff generated from tomato growing area. Monitoring was conducted about 32 event during 4years and water quality parameters such as BOD, $COD_{Mn}$, TOC, TSS, TN, TP, $NH_3-N$, $NO_3-N$, $PO_4-P$ were analyzed at the laboratory. The average EMC were measured as follows: 9.6 BOD mg/L, 17.2 $COD_{Mn}$ mg/L, 5.5 TOC mg/L, 319.4 TSS mg/L, 4.4 T-N mg/L, 2.6 T-P mg/L, 0.5 $NH_3-N$ mg/L, 0.04 $NO_2-N$ mg/L, 2.6 $NO_3-N$ mg/L, 0.8 $PO_4-P$ mg/L. TN and TP is dichargeed as $NO_3-N$ and particle phosphorus type, respectively.

Application of Free Water Surface Constructed Wetland for NPS Control in Livestock Watershed Area (축산단지 비점오염물질 저감을 위한 자유수면형 인공습지 적용)

  • Lee, Jeong-Yong;Kang, Chang-Guk;Lee, So-Young;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.481-488
    • /
    • 2011
  • Various development activities have lead to the destruction of the ecosystem such as natural wetlands. In order to protect these natural wetlands, the Ministry of Environment (MOE) in Korea enacted the Wetland Conservation Act in 1999 and designated protected areas for wetland conservation. The MOE adapted the use of Best Management Practices (BMP) such as retention ponds and constructed wetlands to treat the polluted water before entering the water system. One of these projects was a free-water surface flow (FWS) constructed wetland built as a secondary treatment unit for piggery wastewater effluent coming from a livestock wastewater treatment facility. Water quality monitoring for the constructed wetland was conducted during rainfall events. The results showed that the average removal efficiencies of TSS, BOD, TN, TP were 86, 60, 45, 70%, respectively. It was observed that the removal efficiency of particulate matter and phosphorus was high compared to nitrogen. Therefore, a longer hydraulic retention time was needed in order to improve the treatment efficiency of nitrogen. The results of this study can contribute to the wetland design, operation and maintenance of constructed wetlands.

Performance assessment of an urban stormwater infiltration trench considering facility maintenance (침투도랑 유지관리를 통한 도시 강우유출수 처리 성능 평가)

  • Reyes, N.J. D.G.;Geronimo, F.K.F.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.424-431
    • /
    • 2018
  • Stormwater runoff containing considerable amounts of pollutants such as particulates, organics, nutrients, and heavy metals contaminate natural bodies of water. At present, best management practices (BMP) intended to reduce the volume and treat pollutants from stormwater runoff were devised to serve as cost-effective measures of stormwater management. However, improper design and lack of proper maintenance can lead to degradation of the facility, making it unable to perform its intended function. This study evaluated an infiltration trench (IT) that went through a series of maintenance operations. 41 monitored rainfall events from 2009 to 2016 were used to evaluate the pollutant removal capabilities of the IT. Assessment of the water quality and hydrological data revealed that the inflow volume was the most relative factor affecting the unit pollutant loads (UPL) entering the facility. Seasonal variations also affected the pollutant removal capabilities of the IT. During the summer season, the increased rainfall depths and runoff volumes diminished the pollutant removal efficiency (RE) of the facility due to increased volumes that washed off larger pollutant loads and caused the IT to overflow. Moreover, the system also exhibited reduced pollutant RE for the winter season due to frozen media layers and chemical-related mechanisms impacted by the low winter temperature. Maintenance operations also posed considerable effects of the performance of the IT. During the first two years of operation, the IT exhibited a decrease in pollutant RE due to aging and lack of proper maintenance. However, some events also showed reduced pollutant RE succeeding the maintenance as a result of disturbed sediments that were not removed from the geotextile. Ultimately, the presented effects of maintenance operations in relation to the pollutant RE of the system may lead to the optimization of maintenance schedules and procedures for BMP of same structure.

A Study on the Simulation of Non-Point Pollutant in Hapcheon Dam Watershed Using HSPF Model (HSPF 모델을 이용한 합천댐 유역의 비점오염물질 유출 모의 방안에 대한 연구)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.421-421
    • /
    • 2019
  • 본 연구의 목적은 HSPF 모델을 이용하여 비점오염물질이 수질에 미치는 영향을 평가하는 것이다. 합천댐 유역을 연구대상지역으로 선정하였으며, 입력자료는 유역도, 하천도, 토지이용도, 수치표고모델 및 기상자료 등을 이용하였다. HSPF 모형은 2000년부터 2016년까지의 실측값을 이용하여 보정 및 검증이 이루어졌다. 수문 보정을 위한 매개변수는 사용자 설명서와 참고문헌에 근거하여 선정하였으며, 시행착오법에 의해 수행되었다. 모델의 적용성 평가는 $R^2$, RMSE, RMAE, NSE를 사용하였고 $R^2$가 0.78에서 0.83, RMSE는 2.55에서 2.76mm/day, RMAE는 0.46에서 0.48mm/day, NSE는 0.81에서 0.82까지의 범위로 나타났으며, 연간 유출량이 ${\pm}4%$ 오차 이내로 산정되었다. 수질 모형을 구동하기 위한 수질 자료는 환경부에서 제시한 지침에 따라 생활계, 축산계, 산업계, 토지이용량에 따른 발생 부하량과 배출부하량을 산정하였다. 수질 모형 또한 수문과 같은 기간의 자료를 이용하여 보정 및 검정이 이루어졌다. 보정 결과 연평균 BOD의 차이가 0.22mg/L이고 오차범위는 13%였으며, T-N과 T-P는 0.66mg/L, 0.027mg/L의 차이를 가지며 오차범위는 각각 16%, 13%로 나타났다. 수질항목 중에서도 비점오염 관리의 효과를 평가하기 위해 비점오염물질 중 가장 큰 비중을 차지하는 축산계에 감소 시나리오를 적용하였다. 축산계의 배출부하량 감소율이 20%일때의 BOD, T-N, T-P는 각각 3%, 1%, 3% 감소하였으며 40% 감소율을 적용하였을때는 5%, 3%, 4% 감소하였다. 이러한 수질 해석을 결과를 토대로 효과적인 오염물질 방법을 적용하여 수질 개선과 합천댐 유역의 목표수질을 달성 할 수 있을 것으로 판단된다.

  • PDF

First-flush Runoff Characteristics of NPS from golf course (골프장에서 발생하는 비점오염원의 초기유출수 특성)

  • Shin, Min-Hwan;Choi, Jae-Wan;Choi, Yong-Hun;Seo, Ji-Yeon;Lee, Jae-Woon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1129-1133
    • /
    • 2010
  • 본 연구에서는 수질오염총량제와 정책제안의 원활하고 합리적인 추진을 위해 토지피복분류체계의 대분류중 초지에 해당하고 중분류 중 골프장에 해당하는 지점을 선정하여 강우에 의해 발생하는 비점오염물질의 유출특성을 분석하였다. 연구기간 동안 총 27번의 강우사상으로 인해 발생하는 강우유출수에 대하여 유량과 수질농도를 측정하였다. 유량측정은 웨어를 통한 수위를 측정하여 유량으로 환산하였고, 수질항목은 $BOD_5$, $COD_{Mn}$, DOC, SS, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P 등 9개 항목을 분석하였다. 분석된 결과를 이용하여 골프장에서 발생하는 비점오염원의 초기세척효과 발생여부를 판단하기 위하여 누적오염부하량/누적유출량 그래프를 도식화하였다. 연구기간동안 발생한 5~82 mm의 강우로 인해 6.6~2,082 $m^3$의 유출이 발생하였다. 발생된 유출수의 농도는 $BOD_5$ 1.8~11.3 mg/L, $COD_{Mn}$ 19.2~51.4 mg/L, DOC 11.0~31.0 mg/L, SS 2.2~57.3 mg/L, T-N 1.545~16.098, T-P 0.230~4.528 mg/L, $NH_3$-N 0.076~5.285 mg/L, $NO_3$-N 0.122~2.905 mg/L, $PO_4$-P 0.005~2.631 mg/L로 나타났다. 초기유출수의 세척효과는 27번의 강우사상동안 SS 항목의 경우 17번, $NO_3$-N 11번, $NH_3$-N 4번 등이 발생하였다. 초기세척효과가 발생한 강우사상은 초기의 오염원 농도가 중 후반 농도보다 농도가 높음을 의미하므로, 골프장에서 발생하는 강우유출수는 초기에 발생하는 오염원에 초점을 두고 처리방안을 모색해야 할 것으로 판단된다. 또한 SS와 질소계열의 농도가 높은 것은 골프장의 잔디관리를 위한 농약이나 제초제 등의 사용과 토양유실이 원인인 것으로 판단되며, 이를 저감하기 위한 적절한 사용방안과 저감대책이 필요할 것으로 판단된다.

  • PDF

Characteristics of stormwater runoff from urbanized areas (도시화된 토지이용에서 유출되는 강우유출수의 유출특성분석)

  • Mercado, Jean Margaret R.;Geronimo, Franz Kevin F.;Choi, Jiyeon;Song, Young-Sun;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.14 no.2
    • /
    • pp.159-168
    • /
    • 2012
  • Stormwater runoff affects the quality of surface water and groundwater due to the nonpoint sources (NPSs) of pollutants that it carries during storm events. Typically, urbanized areas experience high pollutant mass emission because of paved roads and other areas which are all highly impervious. For this reason, proper identification of the levels of pollutants from the watershed area is important to pass the Ministry of Environment of the Republic of Korea's water quality standards in rivers and streams. This research was conducted in order to determine and quantify the different constituents present in stormwater runoff generated from highly impervious areas in Cheonan City, Korea. Also, the average event mean concentration (EMC) of stormwater runoff from paved areas was compared with EMCs of other countries to determine the possible causes of its occurrence. In addition, the occurrence of first flush phenomenon was studied in order to find the first flush criteria to be used on the design of best management practices. The results show the pollutant concentration of stormwater runoff was higher than other countries due its landuse and relatively small size of catchment area. During the first 30 minutes of the rainfall events, occurrence of first flush phenomenon was highly evident. Several factors affected the pollutant concentrations in the stormwater such as landuse type, geographic and topographic characteristics,catchment area and amount of rainfall. This research can provide guidance in achieving an effective NPS pollution management applicable to highly urbanized areas in the future.

Tracking of Contaminant Concentration in River Using High-performance GPS Electronic Drifter (고성능 GPS 전자부자를 이용한 하천에서의 오염물질 농도 추적)

  • Lee, Chang Hyun;Nam, Su Han;Lee, Jeong Min;Kim, Young Do
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.166-166
    • /
    • 2021
  • 국내·외 유해화학물질 유출로 인한 하천오염사례가 많이 일어나고 있다. 이때 수질의 농도측정은 직접 도섭으로 하천의 정보 대한 정보를 취득하기 어렵기 때문에 간접적인 방법으로의 정보취득이 중요시 되어야 한다. 그에 따른 방법으로 주입식의 표면부자를 활용한 방법 이용한 수질농도 측정방법 등이 있다. 하지만 이런 농도추정은 이동확산으로 인한 변위가 커지게 되어 시간간격 설정에 대한 어려움 등이 있고, 수질오염에 대한 추적이 가능할 수 있을지에 대한 분석연구가 필요하다. 따라서 이러한 수질농도의 대한 분석을 실시하여 고성능 GPS전자부자를 이용한 추적이 필요하다. Lab-Scale에서 GPS 전자부자를 이용하여 수질정보취득에 일반항목인 수온, PH, EC, DO을 측정함으로써 일반항목에 대한 상관관계와 그에 따른 관계곡선을 제시하고, 고성능 GPS 전자부자를 이용한 측정결과와 YSI를 이용한 측정결과를 비교분석하여 농도경향에 대한 추적으로 오염물질이나 유해화학물질의 정보전달을 통해 원인분석 및 예상경로를 파악할 수 있다. 또한 간접적인 측정을 통해 진행되고 실시간으로 정보를 취득할 수 있기 때문에 수질측정에 접근성 및 안정성 까지 확보할 수 있다. 더 나아가 홍수시 사용뿐만 아니라 기본에 사용되는 수질측정 방법의 한계점까지 보완할 수 있다. GPS 전자부자의 지속적인 연구는 향후 하천 측정 시스템에 많은 도움을 줄 것으로 사료된다.

  • PDF