• 제목/요약/키워드: 오리피스 직경

검색결과 83건 처리시간 0.025초

유체기구를 이용한 유압계통의 충격치제어에 수탄되는 반응지연에 관한 연구 (A Study on the Associated Response Lag in Shock Control of Hydraulic System Using Fluid Device)

  • 이주성;이계복
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1488-1495
    • /
    • 2002
  • The response time represents how fast a system responds to a given disturbance at the system boundary. Flow restricting devices for controlling transients can result in a decrease in the peakm pressure, but may change response time. Response lag in a hydraulic system leads to inefficient working cycle and operator discomfort. The experiments were conducted in order to get information on the parameters which exert appreciable influence on the response time. The experimental apparatu including a hydraulic actuator, orifice and a hydraulic pump was an idealization of a bucket hydraulic shifting system. Experimental results show that the response time depends on operating pressure and flow rate. The effects of orifice type and size on the response time are quantified.

LNG선용 / 발전설비용 가변 오리피스형 과열도 (Variable Orifice De-super Heater for LNG Carrier or Power Plant)

  • 최두열;이종수;최현규;최순호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.210-211
    • /
    • 2005
  • Desuperheater is a passive device to control the temperature of steam in various plants. However, in spite of its simple structure, the accurate prediction of a desuperheater is very difficult because there are many designed factors for the design of a desuperheater. In this study, the theory of heat transfer phenomena in a desuperheater was developed and the various design factors are evaluated. As a results, we confirmed that the droplet size of 30 - 200 is best effective for the performance of a desuperheater.

  • PDF

유체기구를 이용한 유압계통에서의 충격치 제어에 관한 연구 (A Study on the Control of Shock in the Hydraulic System Using the Fluid Device)

  • 이주성;이계복;이충근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.621-626
    • /
    • 2000
  • Reduction in pressure transients may be important in the hydraulic system and necessary to avoid failure and to improve the efficiency of operation. This study addresses the design and use of an orifice to provide the desired control of the hydraulic actuator system. The experimental apparatus is a model of an automobile shift system. Control is accomplished by installing four different diameter ratio of orifices at appropriate locations in the system. Experimental results show that the orifice can be used to obtain the control of shock and the control level depends on the orifice size, orifice type, operating conditions.

  • PDF

유체기구를 이용한 유압계통의 충격치제어에 수반되는 응답시간 변화특성에 관한 연구 (A Study on the Response Time Characteristics Related to Shock Control in the Hydraulic System Using the Fluid Device)

  • 이주성;이계복;이충구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.597-603
    • /
    • 2001
  • Control of pressure transients in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary. Occasionally the appropriate response time is not easily determined. This study is on the response time characteristics in the hydraulic system studied for the control of response time.

  • PDF

유동방향의 초원형 오리피스 형상 변화가 관유동에 미치는 동특성 연구 (A Dynamic Characteristics of the Tube Flow with the Variations of the Axially-Positioned Super-Circled Orifice Shape)

  • Kim, Youn J.;Lee, Sang-Sub
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.52-57
    • /
    • 1997
  • 유동방향으로 초원형 형상을 갖는 잘록한 관내의 압축성 유동에 관한 동특성을 수치적으로 연구하였다. MacCormack의 양해법, 즉 예측자/보정자 단계를 거친 시간 진행법을 이용하여 Euler 방정식의 해를 구하였는데, 관내 유동은 이차원, 비점성, 압축성 유동이라 가정하였다. 관의 직경비와 형상비가 압력분포에 미치는 영향을 광범위하게 고찰하였으며, 본 연구에서 개발한 전산프로그램을 이용한 수치 결과는 상용코드인 FLUENT를 이용한 결과와 비교하여 일치된 결과를 얻을 수 있었다.

  • PDF

고응답 비래 유량제어 밸브의 동특성 향상에 관한 연구 (A Study on Dynamic Characteristics Improvement of Fast Response Proportional Flow Control Valve)

  • 김고도;김원수;이현철;윤소남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1053-1057
    • /
    • 1996
  • The purpose of this study is to bring out the optimal design factors which effect on dynamic characteristics in the design of proportional flow control valve with fast response characteristics, and to verify the validity of the design factors In this study, force feedback type flow control valve with nozzle-flapper is studied. And, the influences which fixed orifice, nozzle diameter, and maximum displacement between nozzle and flapper effect on dynamic characteristics are analyzed. We have done simulations using the optimal design factors and simulink(Matlab) as a simulation tool, and verified the validity of our simulations by means of comparison our simulation results with an experimental results of another similar valve.

  • PDF

지하 공간의 워터커튼 시스템 화재제어 특성 분석 (An Analysis of the Smoke Control Characteristics of Water Curtain System for Underground Space)

  • 유우준;남준석;최진종;이정균;김동준;유홍선
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.298-301
    • /
    • 2011
  • 본 연구에서는 지하 방호공간에서 화재가 발생한 경우 워터커튼 시스템에 의한 연기의 차단효과와 화재제어 특성을 분석하였다. 이를 위해서 분사각도 $180^{\circ}$, 오리피스 직경 8.2 mm의 노즐과 지하방호 공간용 실화재 실험 장치를 제작하였으며, 화재강도 1.5 MW 기준 A급 1단위 화재 실험으로부터 온도분포와 가시도를 측정하여 연기의 차단효과를 확인하였다. 화재제어 특성을 분석하기 위해서 NIST(National Institute of Standards and Technology)의 해석프로그램인 FDS(Fire Dynamic Simulator)를 사용하여 동일한 실험조건에서 온도분포를 비교하였으며 노즐의 설치개수 변화에 대한 화재해석 및 실험결과로부터 워터커튼 시스템은 노즐의 설치위치와 개수, 화원으로부터의 거리, 제연 등의 설비 조건과 분사 노즐의 특성, 공급 유량 등이 중요한 상관관계를 갖고 있음을 확인하였다.

  • PDF

이유체 충돌 분사기의 혼합특성에 관한 연구 (A Study of mixing characteristics of unlike impinging streams doublet injector)

  • 한재섭;김선진;김유
    • 한국추진공학회지
    • /
    • 제4권4호
    • /
    • pp.36-41
    • /
    • 2000
  • 액체로켓에서 설계된 추진제를 엔진내로 분사하고, 미립화 및 혼합시키는 분사기고서, 널리 사용되어온 이유체 충돌분사기의 혼합특성은 연소안정성 및 연소효율에 주요한 영향을 미치는 인자이다. 따라서 본 연구는 이유체 충돌 분사기의 설계변수인 충돌각, 오리피스 직경비 및 운동량비가 질량분포 및 혼합성능에 미치는 영향을 규명하기 위하여, 추진제대용으로 물과 TCE를 사용하는 비연소시험법에 의해서 수행되었다.

  • PDF

대형기관 모사 정적연소실에서 매립지 가스의 연소특성에 대한 연구 (III) - 토치 점화 (1) - (Combustion Characteristics of Landfill Gas in Constant Volume Combustion Chamber for Large Displacement Volume Engine (III) - Torch Ignition (1) -)

  • 김인옥;엄인용;권순태
    • 대한기계학회논문집B
    • /
    • 제39권2호
    • /
    • pp.125-134
    • /
    • 2015
  • 본 논문은 대형 상용기관을 모사한 정적연소실에서 매립지 가스의 연소 특성에 대한 복수의 논문 중 세 번째로, 정적 연소실에서 토치를 적용하여 그 효과를 분석하였다. 실험 결과 토치의 체적에 관계없이 연소를 개선시키는 최적의 오리피스 면적 비율이 존재하며 오리피스가 매우 작은 경우 압력 상승비율은 직경 변화에 무관하게 일정 수준을 유지하거나 소폭 감소한다. 아울러 토치의 효과는 일차적으로 연소 시간단축에 영향을 주고 시간단축에 따른 전열량의 감소가 이후 압력상승에 기여한다. 마지막으로 메탄 분율이 적어 연소 조건이 나쁠수록 토치는 주로 주 연소 기간을 단축시키고, 반면 연소 조건이 좋은 경우 주로 초기 연소를 단축시키는 효과가 있다.

오리피스 유량계와 터빈 유량계의 직관부길이와 유동안정기에 관한 연구 (A Study of Straight Pipe Length and Straightener in Orifice Meter Turbine Meter)

  • 허재영;안승희;이강진;이승준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.265-271
    • /
    • 2000
  • Orifice meters and turbine meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate and also to analyze flow measurement errors of the turbine meter with and without straightener. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested In the standard, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the mon the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF