• Title/Summary/Keyword: 영하온도

Search Result 105, Processing Time 0.03 seconds

Strength Properties of Mortar Mixed with Accelerator for Freeze Protection in Constant and Variable Temperature Condition (정온 및 변온조건하에서 내한촉진제를 혼합한 모르터의 강도특성)

  • Kim, Young-Jin;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.942-948
    • /
    • 2002
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and the strength development may be delayed. One of the solution methods to resolve these problems is to reduce freezing temperature of concrete by the use of chemical admixture called Accelerator for freeze protection. In this study we Investigate the effect on the strength development of cement mortar using accelerator for freeze protection with the variable curing condition. As the result of this study, the mortar using accelerator for freeze protection show continuously the strength development in curing condition of -5$^{\circ}C$. And the compressive strength under variable temperature condition was higher than constant temperature condition in same maturity.

Analysis on Freezing Reduction of Road Tunnels with Heat Insulation Method during Winter (단열공법이 적용된 겨울철 도로터널의 동결저감 효과 분석)

  • Son, Hee-Su;Jun, Kyoung-Jea;Yune, Chan-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.8
    • /
    • pp.17-27
    • /
    • 2017
  • Gangwon province which is located in northeast of Korea is the coldest region where average daily temperature is below zero during winter while the other regions are above zero. However, there have been insufficient researches on the insulation design and the effect of the insulation on the freezing damages, even though freezing damages were reported consistently in the lining of road tunnel during winter. In this study, to investigate the effect of insulations on the reduction of freezing damages, numerical analysis was performed considering geotechnical and meteorological characteristics in Gangwon province during winter. As a result, it was found that thickness of concrete and shotcrete in lining had negligible effect on the freezing depth while the insulation had significant effect on it. In addition, because the freezing depth is greatly affected by the thermal conductivity of the ground behind the lining in the period of cold weather, these effects should be considered in the estimation of the insulation thickness.

Utilization of Waste Tries in Cement Kiln as an Energy Source (시멘트 소성공정에서 폐타이어의 효율적 열이용 연구)

  • 노갑수;서형석;이영조;김영하;최명일
    • Resources Recycling
    • /
    • v.4 no.4
    • /
    • pp.37-58
    • /
    • 1995
  • Whole tues were put uto cement kiln inlet where the tempmalures or gas and cemcnt-raw-materials were 1050 and 800- 850.C. respcclrvely. Tl~ck iln consisls of \ulcorner-stage suspension preheatel- and air quenching coolers The amount of wusle tlrcs added in lhc normal encrgy in lhc ce~ncnlk iln was 3, 5, 7% by volume Welght and steel contents of tiles. ulti~~iaalcn d elemental analysis, ash contents. ash hsion temperature. etc, wete detcnutned to inveshgate thc prnpcrlics a1 tires and ilreir ashes. Flucluat~ons of cement kiln placess, cement quality and an pollulton were invesligalerl during lhc burning tins. When the Ieeding ralio ol wasle lires to normal cncrgy was 50'0, there was nn wlde d~ffereilces m the cemmt quctlity and air pollutcon between operation with tiles and withoul tires. Tl~ch cal iccovcry was uhout 50% w~th5 % add~tionI n the nonndl energy. There was a little lxt fluctuation of cement quultty ncld an pollution at olher feeding ralios.

  • PDF

Thermal Properties of Linear Shape Polylactic Acid/Star Shape Polylactic Acid Blends (선형 폴리락틱산/스타형 폴리락틱산 블렌드의 열적 특성 변화에 대한 연구)

  • 천상욱;김수현;김영하;강호종
    • Polymer(Korea)
    • /
    • v.24 no.3
    • /
    • pp.333-341
    • /
    • 2000
  • Blends consisting of linear shape polylactic acid and star shape polylactic acid (L-PLLA/S-PLLA) have been prepared by melt and solution blending. The effect of blending method on the thermal properties and crystallization behavior of L-PLLA/S-PLLA blends has been investigated. The molecular weight decrease was revealed both in melt and solution blending. S-PLLA was found to be more stable than L-PLLA in the reduction of molecular weight during the course of blending due to its star shape structure. As a result, broad molecular weight distribution was obtained in solution blending. It was found that melting temperature and glass transition temperature decrease with increasing S-PLLA content. Blending method had large influence on the glass transition temperature of PLLA blends, while less effect on melting temperature. From DSC results, it can be noticed that solution blending is more effective blending method to obtain higher crystallinity than melt blending for S-PLLA and blend with higher S-PLLA content.

  • PDF

비활성 가스제너레이터 성능분석

  • 김수용
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.14-14
    • /
    • 1999
  • 비활성 가스제너레이터는 가스터빈 추진기관 및 기타 열기관을 이용하여 연소가 되지 않는 저온의 공기를 생산하는 기계장치를 말하며 이러한 저온의 비활성 기체를 화재 지역에 분사하는 경우 기존의 소방수를 이용한 화재 진압방식보다 매우 효율적으로 화재진압에 사용되어 질 수 있다. 일반적으로 민항기 등의 가스터빈 추진 기관에서 배기되는 기체내에는 터빈입구온도(TIT : Turbine Inlet Temperature)및 초과공기지수(Excess Air Coefficient)에 따라 다르게 나타나지만 TIT가 1500$^{\circ}$K인 경우 약 13-14%정도의 산소가 잔존하는 것으로 알려져 있다. 따라서 본 연구에서는 가스터빈 및 열교환 시스템 그리고 터빈 1단 등의 시스템 조합율을 통하여 대기 중의 기체의 온도를 영하 2$0^{\circ}C$ 및 산소함유량을 약 5%수준까지 낮춤으로서 이를 대형 화재 진압에 사용하기 위한 연구이다. 비활성 가스제너레이터에 사용하는 연료로는 Kerosene 및 CNG(Compressed Natural Gas)등이 사용될 수 있으며, 유량이 8.1kg/sec인 터보축 가스터빈 엔진을 사용하는 경우 18750㎥ 부피의 비활성기체를 생산하는데 Kerosene 연료가 약 1톤(200$ 이하)이 필요한 것으로 계산되며 이에 소요되는 시간도 약 52분에 지나지 않는 것으로 계산되었다. 만일 50kg/sec의 보다 큰 가스터빈 엔진을 사용하는 경우 약 9분 정도가 필요한 것으로 계산되었다. 사용되는 가스터빈은 압축비가 15, 열교환기의 효율이 $\varepsilon$=0. 그리고 최종 터빈 1단의 팽창비가 1.25가 적합한 것으로 계산된다. 연구 분석 결과 기술적 문제점으로는 배기 가스온도가 낮은데 따른 출구 부분의 Bearing, Sealing이 문제가 될 수 있다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.

  • PDF

A study for Shear Strength Characteristics of Frozen Soils under Various Temperature Conditions and Vertical Confining Pressures (동결온도조건 및 수직구속응력에 따른 동결토의 전단강도 변화에 관한 연구)

  • Lee, Joonyong;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.51-60
    • /
    • 2012
  • In order to characterize the shear strength of the frozen sand for foundation design in cold region and prediction of adfreeze bond strength, many researchers developed test techniques and carried out many tests to analyze shear strength properties of the frozen sand for half a century. However, many studies for shear strength properties of the frozen sand have been carried out with limited circumstances, even though shear strength of the froze sand can be affected by various influence factors such as soil type, temperature conditions, and magnitude of normal stress. In this study, direct shear test equipment was used to analyze the shear strength characteristics of the frozen sand. Direct shear test equipment was designed for cold weather, and the direct shear tests were carried out inside of large-scaled low temperature chamber. Three soil types-two uniform sands and one well graded soil were used to analyze the shear strength of the frozen sand with three different temperature conditions and three different vertical confining pressures. In this research, a series of direct shear tests for shear strength of the frozen sand have been conducted to demonstrate the efficiency of effectiveness of the test equipment and low temperature chamber. This research also showed that shear strength of the froze sand increased with decreasing temperature condition, but the influence of vertical confining pressure was insignificant to the shear strength of the frozen sand.

Evaluation of Installation Length of CWR Considering Rail Tenser's Capacity And Track Maintenance (레일긴장기의 성능을 고려한 효율적인 장대레일 설정방법)

  • Park, Ok-Jeong;Kim, Eung-Rok
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.72-79
    • /
    • 2010
  • The significant of continuous welded rail (CWR) management is growing because KORAIL has the plan to convert the whole of conventional railway lines into CWRs through continuous activities since constructed the CWR track with 1.8km in Gyeongbu line in 1966. The CWR recently is needed a efficient management method because it is difficult to manage the CWR by the poor of technic and equipment, limited maintain labor force and shorted the maintain work time of CWR caused by industrialization, greenhouse effect and global warming In this point, The 70ton Tenser's which is using in the rail site has been analysised with no extra tenser's capacity in case of the under low temperature and exceed the length of 1km as a result of reviewing the CWR-related rules and standards, a series of records of safety accidents, operation obstacles, and the situation of broken rails published by KORAIL, existing rail temperature measurements, and CWR researches. Therefore avoid the excessive plan of the first set-up section, choice the proper time in the normal temperature that is possible to weld the rail, turning the difference of rail temperature and Installation temperature down is desirable.

  • PDF

Large Scale Application of High Speed Nitriding Technique by Hollow Cathode Discharge

  • Mun, Jong-Cheol;Jo, Gyu-Yeong;Yu, Jae-Mu;An, Seung-Gyun;Jeon, Yeong-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.220.2-220.2
    • /
    • 2014
  • 플라즈마 질화 기술은 기존의 침탄 혹은 고주파 표면 경화 기술 대비 낮은 온도에서 열처리 공정이 진행됨에 따라 열 변형을 최소화 시킬 수 있으며, 후 가공을 간소화 시킬 수 있다는 장점으로 인해 자동차 부품 및 기타 응용 산업 분야에 있어 큰 관심을 받고 있다. 그러나 공정 진행에 장시간이 소요되고 복잡한 형상 및 홀 가공에 의한 기능부, 특히 내경부에 대한 균일 질화 처리가 어려워 실제 응용분야 확장에 큰 제약이 따르고 있다. 이를 해결하기 위해 본 연구에서는 일반 글로우 방전 대비 플라즈마 밀도가 10배 이상 높은 공공 음극 방전(Hollow Cathode Discharge, 이하 HCD) 현상을 이용하여 고속 고균일 질화공정을 개발하고자 하였으며, 상용화 적용을 위한 연구를 함께 진행하였다. 사용된 시료로는 실제 자동차 부품으로 사용되는 SCM415 소재의 ring gear와 slip yoke pipe를 사용하였으며, HCD 형성을 위해 특화된 플라즈마 질화장비를 활용, 공정 압력 및 인가 전력 등을 변수로 실험을 진행 하였다. 그 결과 질화 처리 속도에 있어 기존 글로우 방전 플라즈마 질화 대비 1/4 이하 수준으로 그 소요 시간을 단축시킬 수 있었으며, 다량 장입된 시료의 내경 기능부에 있어서도 높은 균일도를 갖는 질화표면이 형성됨을 확인할 수 있었다. 또한 기능부 표면에 형성된 HCD 현상을 열원으로 사용함으로써 외부가열 장치를 사용하지 않으면서도 기존의 hot wall 방식보다 높은 질화 균일도 구현이 가능하였으며, 소요 자원 및 전력 사용 측면에 있어서도 공정 시간 단축 및 외부 가열 공정 제거에 의한 높은 수준의 에너지 절약이 가능하였다.

  • PDF

Development of Lightweight DMFC System for Charging Secondary Battery in Military Operational Environment (군 운용환경에서 이차전지 충전을 위한 경량화 DMFC 시스템 개발)

  • LEE, SUWON;GWAK, GEONHUI;RO, JUNGHO;CHO, YOUNGRAE;KIM, DOYOUN;JU, HYUNCHUL
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.5
    • /
    • pp.481-491
    • /
    • 2017
  • In this study, we developed 300 W lightweight DMFC system for charging secondary battery in small unit military operation. In order to reduce the volumetric shape and weight of the system considering the environment of the individual soldier's, the arranging of system components has been optimized. A metal bipolar plates made of STS-470FC have been implemented to the DMFC stack to meet the weight demand of the system. As a result of the performance test of the stack, the target value was satisfied by outputting 561 W exceeding 24% of the stack output 450 W required to output 300 W required for the entire system. Moreover, 2,655 hours exceeding 1,000 hours also has been satisfied. To ensure good robustness of the metallic bipolar plate based DMFC stack, finite element method based simulations are conducted using a commercial ANSYS Fluent software.

The Characteristics of Thermal Diffusion With the Vertical-Closed Loop Type Geothermal Heat Exchanger (수직밀폐형 지중열교환기의 온도분포 특성)

  • Sun, Jong-Cheol;Kim, Byung-Chul;Koh, Young-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.57-65
    • /
    • 2013
  • The temperatures with the ground depth, the positions of circulation water in ground heat exchanger were measured and thermal diffusion characteristics with the distances of the direction normal to the borehole was analysed. The deeper the depth of ground, the less the influences of outdoor temperature, but below 10m of ground, there was no influences of ground temperature. When the depth of trench pipe was below the depth of 2m, there was no influence. In the ground of 10m when the distances between the pipe and the other places were above 0.5m, the variations of temperature were less than $1.6^{\circ}C$ and above 2.5m they were less than $0.1^{\circ}C$. When the distances of bore hole were above 5m, there were no. influences of the nearest ground heat exchanger.