• Title/Summary/Keyword: 영상 대조

Search Result 677, Processing Time 0.024 seconds

A Method of Deriving an Intensity Mapping Function by Using The Variational Technique (변분법을 이용한 명암도 변환 함수 획득 방법)

  • Kim, Jun-Hyung;Noh, Chang-Kyun;Ko, Sung-Jea
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.5
    • /
    • pp.10-15
    • /
    • 2011
  • Histogram equalization is an effective method to enhance the contrast of the image. However, it can result in unwanted artifacts such as excessive contrast enhancement and noise amplification. These artifacts can be reduced by modifying an intensity mapping function which is generated by histogram equalization. In this paper, we present a variational approach to the modification of the intensity mapping function. We define a functional whose minimization produces a modified intensity mapping function. Experimental results show that the intensity mapping function obtained by the proposed method can enhance the contrast of the image without visual artifacts.

Improving Image Quality of MRI using Frequency Filter (Frequency Filter를 사용한 MRI 영상 화질의 향상)

  • Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.309-315
    • /
    • 2009
  • Image reconstruction of Inverse Fourier Transform after Frequency Domain Data is filtered applies to Image signal acquired from MR. There are various kinds of image processing techniques; image preprocessing, image reconstruction, image compression, image restoration image mixture, noise and artifact elimination, and image quality improvement. In this paper, optimum filter applicable to diagnosis in clinic by comparing and analyzing the characteristics of the filter will be explained. Fermi-Dirac filter will improve the image quality better than the previous MR image.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

의료 영상을 이용한 영상 분할 알고리듬 연구

  • 호동수;이형구;김성현;김도일;서태석;최보영;이진희
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.77-77
    • /
    • 2003
  • CT와 MRI의 단면 영상을 대상으로 영상분할 (Image segmentation)과 Image registration방법을 이용하여 인체 모델을 개발 하고자 한다. 우선 인체의 Head와 Neck부분의 CT와 MR 영상을 얻어 뼈, 근육, 인대, 그리고 그 밖의 장기의 해부학적 영상 특징을 분석하였다. 인체의 Head와 Neck 부분에 대한 CT와 MR 영상에 대해 각 부위별로 ROI(region-of-interrest)를 설정하였고, 각 volxel 마다 3차원 좌표를 계산할 수 있는 소프트웨어를 개발하였다. 특히 각 해부학적 영상에서 부위별로 CT 번호를 분석하고, pulse sequence에 따른 MRI 영상의 부위별 특정을 분석하였다. 이 분석한 자료를 바탕으로 영상 분할을 하였다. 영상 분할전에 각종 잡음(noise) 제거 및 영상 분할을 효과적으로 처리하기 위해 기본적인 영상처리 (filtering)를 구현하였고, 대조도(contrast) 및 밝기(brightness)를 조절할 수 있게 프로그램을 구현하였다. 영상 분할 방법 중 선(line) 및 에지(edge) 의 검출 방법, 문턱치화(threshold) 방법, 영역확대(region growing) 방법으로 영상 분할을 해봄으로써 우리의 인체 모델링 개발에 가장 적합한 영상 분할 알고리듬 방법을 찾도록 시도하였다. 결과적으로 말하면, 한가지 방법의 알고리듬을 쓰는 것보다는 인체의 부위에 따라 두 가지 이상의 알고리듬 방법을 쓰는 것이 원하고자 하는 부위를 영상 분할하는데 더 효과적이다는 것을 알게 되었다. 우리의 연구 과제에서는 영역확대(region growing) 방법과 문턱치화 방법, 모드법(피크니스, 밸리)의 알고리듬을 이용하여 영상 분할을 한 결과 우리가 얻고자 하는 인체 부위별 중 근육과 뼈를 구별하는데는 별 무리가 없었으나, 인대 및 기타 장기를 구별하는데는 어려움을 겪게 되었다. 이후에 좀더 알고리듬을 연구하여 이번 연구에서 구별하기 어려운 장기 부분도 구별 할 수 있도록 노력하겠다.

  • PDF

MR Artifacts

  • 문치웅
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.73-83
    • /
    • 2001
  • 영상의 좋고 나쁨을 나타낼 때는 대조도, 해상도, 잡음 그리고 Artifact 등을 정량적으로 측정하거나 기준이 되는 영상과 정성적으로 비교하게 된다. 이 중에서 Artifact는 영상의 해부학적 진단에 오류를 범하게 하여 엉뚱한 병리학적 해석을 내리게 하거나 해석이 불가능하게 하기도 하므로 적절한 규명을 하여 그 원인을 제거하는 등, 응당한 조치를 취해 최상의 화질을 유지하기 위한 노력을 기울여야한다. MR 영상에서 Artifact는 기하학적 늘림(stretch), 주름(wrinkle), 왜곡(distortion), 허상(ghost), 줄(line), 눈잡음(snow noise), 신호의 증감 등과 같은 다양한 현상으로 나타나며 이들은 영상을 해석할 때 오류를 범하는 원인이 된다. Artifact의 발생원인으로는 MR 장치의 기능장애, 부적절한 영상기법의 구사, 또는 MR 영상의 고유한 성질에 기인하기도 한다. MR Artifacts의 근본적인 이해를 위해서는 MRI의 물리적 원리와 장비에 관한 이해가 필요하다. 이렇게 MR Artifact는 여러 가지 인자들이 복합적인 관계를 가지고 나타나기 때문에 분류하기가 쉽지 않지만 전형적인 양상과 원인 그리고 그에 대한 여러 가지 대책을 살펴보고자 한다.

  • PDF

Diffusion Tensor Imaging in Nocturnal Frontal Lobe Epilepsy

  • Son, Chul-Ho;Woo, Sung-Gu;Cho, Yong-Won;Lee, Hyung;Han, Bong-Soo
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.84-84
    • /
    • 2002
  • 목적: 야간성 전두협 발작 (Nocturnal frontal lobe epilepsy NFLE)은 임상적으로 특징적인 야간성 운동성 발작으로 잘 알려져 있지만 일반적인 MR 영상에서는 대부분에서는 특이한 소견을 보이지 않아 확산 텐서 영상 (DTI)에서의 이상 소견 발현 유무를 알아보고자 한다. 대상 및 방법: 임상적 소견과, EEG 소견으로 진단된 NFLE 환자 6명을 대상으로 DTI 영상을 촬영하였다. 남자 2명, 여자 4명으로 평균연령은 32세 이었다. DTI영상은 single shot spin echo EPI 펄스 열을 사용하였고 사용한 영상 변수는 b value는 0, 1000 s/$\textrm{mm}^2$, TR 10000 msec, TE 71.8/72.3 msec, matrix 128$\times$128 (256 reconstruction), FOV 23cm, 5mm thickness, 2mm interstice gap, NEX 1. 19 slices, time은 4min 21sec (25방향) 이었다. 대조군으로 정상 성인 10명 (평균연령 31세)에서 동일한 방법으로 DTI 영상을 시행하여 분할 비등방도 (fractional anisotropy) 영상을 얻고 전두엽 백질에서 분할 비등방도 값을 측정하여 NFLE 환자군과 비교하였다.

  • PDF

Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study (자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구)

  • Kim, Nam Young;Kim, Ju Hui;Lim, Jun;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Recently, magnetic resonance imaging (MRI), which can acquire images with good contrast without exposure to radiation, has been widely used for diagnosis. However, noise that reduces the accuracy of diagnosis is essentially generated when acquiring the MR images, and by adjusting the parameters, the noise problem can be solved to obtain an image with excellent characteristics. Among the parameters, the number of excitation (NEX) can acquire images with excellent characteristics without additional degradation of image characteristics. In contrast, appropriate NEX setting is required since the scan time increases and motion artifacts may occur. Therefore, in this study, after fixing all MRI parameters through the MRiLab simulation program, we tried to evaluate the tendency of image characteristics according to changing NEX through quantitative evaluation of brain T2 weighted images acquired by adjusting only NEX. To evaluate the noise level and similarity of the acquired image, signal to noise ratio (SNR), contrast to noise ratio (CNR), root mean square error (RMSE) and peak signal to noise ratio (PSNR) were calculated. As a result, both noise level and similarity evaluation factors showed improved values as NEX increased, while the increasing width gradually decreased. In conclusion, we demonstrated that an appropriate NEX setting is important because an excessively large NEX does not affect image characteristics improvement and cause motion artifacts due to a long scan.

Performance Test of the Iterative Method and Newly Developed True X Method (PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가)

  • Choi, Jae-Min;NamKung, Chang-Kyeong;Park, Seung-Yong;Nam, Ki-Pyo;Lim, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • Objective: In this study, the differences between two reconstruction methods were analyzed by comparing image uniformity and contrast according to Iteration and Subset, which were altered through the Iterative method and True X method, used in Siemens' PET/CT studies. Methods: The Phantom images were obtained by exposure for two minutes per one bed. To determine the image uniformity, the Coefficient of variance was used. Also, in order to compare the contrast value, we measured and analyzed the ratio of the SUV mean of Phantom image's hot spheres and the background. Results: Under the same reconstruction conditions (Iteration and Subset) of CV, the Iterative method was higher than the True X method. In the comparison of the SUV mean ratio of the background and hot sphere, the True X method had a closer rate than the Iterative method. Conclusion: The newly developed True X reconstruction method is better than the previously used Iterative method in terms of uniformity and contrast. However, the date for this study was only obtained using the Phantom device. In order to obtain more accurate and useful information from the experiment, further research should be conducted. Also, it is necessary to find the appropriate standards for Iteration and Subset for further experimentation.

  • PDF

Image Quality and Dose Assessment According to Examination Mode during Head CT Examination (두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가)

  • Gang, Heon-Hyo;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2021
  • To evaluate the usefulness of Volume Axial Mode by comparing analyzing the exposure dose of the patients and the quality of each images from CT images obtained from high pitch mode using the local phantom or volume axial mode to determine the usefulness of he volume axial mode in diagnosing the head and cervical disease in adults. High Pitch Mode, Helical Mode, and Volume axial Mode as adult phantom were tested according to 70 kVp, 80 kVp, and 100 kVp tube voltages during an adult frontal CT scans. The equipment used was GE's Revolution (GE Healthcare, Wisconsin USA) model and iMED X-ray Phantom. The exposure dose of phantom was compared using the images obtained from each protocol, and the image quality was compared by calculating SNR and CNR by setting ROI on each image. When examined using Volume Axial Mode, the exposure dose of phantom was measured 17.12% lower than Helical Mode, 5.35% lower than High Pitch Mode, and both SNR and CNR were improved. Volume Axial Mode is a useful test that reduces investigation time without table movement using high speed rotary scanner, and in which exposure dose is reduced and image quality is improved by acquiring images in a short time of 0.28 seconds of phantom than using High Pitch Mode and Helical Mode. In addition, the fast testing time of Volume Axial Mode can be seen as the biggest advantage CT scans of emergency patients or patients with physical discomfort.

Development of algorithm for Maintaining indoor altitude of drone using image-based deep learning (영상기반의 딥러닝을 활용한 드론-실내고도유지 알고리즘 개발)

  • Kim, Jae-Woo;Lee, Dong-Goo;Kim, Tae-Jung;Lee, Jung-Ho;Kim, Sun-Jung;Choi, Sun;Hwang, Heon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.173-173
    • /
    • 2017
  • 드론의 시장규모가 커짐에 따라 초창기 군사 목적에서 현재 민간부문으로 확대되고 있다. 현재 드론은 실외에서 사용될 목적으로 제작된 것이 많으나 실내에서도 드론의 활용 여부가 증가할 것으로 예상된다. 본 연구에서는 실외에서만 사용 가능한 GPS를 대신하여 영상 촬영으로 획득한 이미지를 CNN으로 학습을 시켜 자율고도제어비행을 하도록 한다. 첫 번째로 수동 조작하는 드론에 IMU센서를 부착하여 획득한 고도 데이터를 표로 제시함으로써 GPS를 사용하지 않는 드론의 실내주행에서 일정한 고도 유지는 다소 무리가 있음을 보여준다. 두 번째로 드론의 수동 조작은 일정하지 않은 고도 때문에 CNN의 학습할 영상 획득이 어렵다. 일정한 고도의 영상 획득을 위한 실험용 높이 조절 Base를 제작하여 고도별 영상을 획득한다. 획득한 영상을 통해 얻은 이미지를 CNN 학습을 시킨 후, 학습에 사용되지 않은 이미지를 사용하여 고도 판별을 확인한다. 대조군으로 실내장소를 바꾸어 미리 학습된 CNN으로 고도 판별을 확인한다. 학습에 사용된 이미지의 환경(생명공학관)과 대조군(제 2 공학관)이 촬영된 장소의 환경요소의 차이로 오차가 발생한다. 오차는 실내 장소의 총 높이의 차이 및 서로 상이한 천장 구조물에 따른 것으로 사료되며 Data crop을 통해 획득한 이미지의 천정 부분을 제거하여 노이즈를 줄여 고도 판별의 정확도를 높일 수 있을 것으로 예상한다. 세 번째, CNN으로 학습을 통해 Model을 도출하여 자율 고도 제어 프로세스를 제시한다. 그리고 해당 프로세스를 이용한 자율고도제어 주행과 수동조작을 통한 주행에서의 Z축 가속도 데이터의 표준편차를 비교하여 본 연구의 실효성을 보여준다

  • PDF