• Title/Summary/Keyword: 영상 대조

Search Result 677, Processing Time 0.029 seconds

Agroforestry Site-suitability Analysis in Suan-gun, Hwanghaebuk-do, North Korea (임농복합경영 대상지 적지 분석: 북한 황해북도 수안군을 중심으로)

  • Sookyung, Kwon;Soyoung, Park;Soonduck, Kwon
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.4
    • /
    • pp.667-675
    • /
    • 2022
  • Agroforestry is an ecological and economic land-use system that enables sustainable agriculture by combining forestry, agriculture, and livestock industries. North Korea chose agroforestry as a strategy for the restoration of sloping land and deforested land. Agroforestry was proposed for the inter-Korean forest cooperation subcommittee meeting and is currently highlighting carbon removal and promoting the '2050 Carbon Neutral Strategy' and 'Korea Peninsula Green Détente.' The study area, Suan-gun, Hwanghaebuk-do, is a constant deforestation monitoring area and a pilot site for management by the International Center for Research in Agroforestry. The requirements for agroforestry were analyzed through literature analysis. The agroforestry site-suitability map was visualized by applying GIS overlap analysis. Approximately 8,839 ha of sloping area was selected as suitable for agroforestry management, which is about 15% of Suan. We compared the map with Google Earth images and visually detected the land use status, such as agroforestry in Suan, to verify the results. As a future study, we will consider both natural-environment and socioeconomic factors and evaluate the relative importance of the factors to produce a high-accuracy agroforestry sitesuitability map at the national scale with the goal of producing basic data for the inter-Korea forest cooperation policy for long-term goals.

Correlation Between Degree of Torn Rotator Cuff in MRI and Degenerative Change of Acromion and Greater Tuberosity in Simple Radiography (단순 방사선 사진에서 견봉 및 상완골 대결절의 퇴행성 변화와 MRI상 회전근 개 파열 정도와의 연관성)

  • Choi, Jung-Yun;Yum, Jae-Kwang;Song, Min-Cheol
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose of this study is to analyze the correlation between the degree of torn rotator cuff as recorded by MRI and degenerative change of acromion and greater tuberosity of humerus determined by simple radiographs. Materials and Methods: Of the 518 cases included in this study, a group of 234 cases had a chronic rotator cuff tear and a control group of 284 cases had an intact rotator cuff in shoulder MRI. The degree of degenerative changes was classified according to the length of spur and morphological change of acromion and greater tuberosity through the true anteroposterior simple radiograph in supraspinatus outlet view. The degree of tear (partial-thickness or full-thickness tear) and the size of complete rotator cuff tear were analyzed according to the MRI findings of shoulder. The authors also evaluated the correlation between the degree and size of torn rotator cuff and the degenerative change of acromion and greater tuberosity. Results: There were significant differences in the size and extent of torn rotator cuff according to the age, sex and degenerative change of acromion and greater tuberosity of humerus (p<0.001). More degenerative changes of acromion and greater tuberosity in simple shoulder radiographs showed the increased degree and size of torn rotator cuff (p<0.001). In addition, the higher degree and larger size of torn rotator cuff were noted in older age subjects (p<0.001) and in the female group (p<0.001). Conclusion: More degenerative changes of acromion and greater tuberosity in simple shoulder radiographs showed the increased degree and size of torn rotator cuff. Therefore, if a high degree of degenerative change of the acromion and greater tuberosity on simple radiograph is noted, the possibility of degenerative rotator cuff tear should be considered. In addition, the age and sex could be associative factors for larger size of torn rotator cuff.

Modernist painting style in Disney animation (디즈니 애니메이션에 나타난 모더니즘 회화스타일 : 색, 형태, 공간을 중심으로)

  • Moon, Jae-Cheol;Kim, Yu-Mi
    • Cartoon and Animation Studies
    • /
    • s.33
    • /
    • pp.31-53
    • /
    • 2013
  • In the early twentieth century, history of animation began by modern artists, they produced various experimental images with the newly invented film and cameras. Artists in the field of movie, photography, paintings and others manipulated images in motion. But as some animated movies won industrial success and popularity, they became the trend but experimental style of early animation preserved by so-called non-mainstreamers or experimental animators, counteracting commercialism. Disney animation also followed the trend by applying realistic Hollywood film style, the worse critics placed a low value on the animation and it tarnished the image, although it was profitable investment from a business standpoint. To make images realistic, they opened a drawing class that animators developed skills to imitate motions and forms from subjects in real life. Also some techniques and gizmos were used to mimic and simulate three dimensional objects and spaces, multiplane camera and compositing 3D CG images with 2D drawings. Moreover, they brought animation stories from fairly tales or folk tales, and Walt's personal interest in live-action movies, they applied Hollywood-film-like narratives and realistic visual, and harsh criticism ensued. On the surface early disney animations' potential seems to be weakened, but in reality it still exists by simplifying and exaggerating forms and color as modern arts. Disney animation employs concepts of the modernism paintings such as simplified shapes and colors to a character design, when their characters are placed together in a scene, that visual elements cause mental reaction. This modification gives a new internal experience to audiences. As conceptual colors in abstract paintings make images appeared to be flat, coloring characters with no shading make them look flat and comparing to them, background images are also appeared to be flat. On top of that, multi-perspective at background images recalls modernist paintings. This essay goes in details with the animation pioneers' works and how Disney animation developed its techniques to emulate real life and analyses color schemes, forms, and spaces in Disney animation compared with modern artists' works, in that the visual language of Disney animation reminds of impression from abstract paintings in the beginning of the twentieth centuries.

REMINERALIZATION EFFECTS OF GLASS IONOMER RESTORATIONS ON ADJACENT INTERPOXIMAL-A MICROTOMOGRAPHIC STUDY (미세전산화 단층 촬영을 이용한 글라스 아이오노머 수복의 인접면 재광화 효과에 대한 연구)

  • Lee, Hyeok-Sang;Lee, Sang-Dae;Kim, Jung-Wook;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.474-480
    • /
    • 2004
  • The purpose of this in vitro study was to compare the remineralizing effects of three glass ionomer cements (high filled glass ionomer cement, compomer, resin modified glass ionomer cement) with resin composite (control group) on incipient interproximal caries, and to assess long-term change of remineralization effect, in each material, evaluated by microtomography. Proximal restoration was simulated with tooth specimen and Glass Ionomer Cements. And each of these groups was placed into a closed container with artificial saliva at $37^{\circ}C$ and pH 7.0 for a time period of thirty days with constant circulation. At the end of thirty and sixty days, tomographic images were taken from these specimens with micro CT scanner. Materials used in this study were as follows. Group 1: Fuji IX GP (GC Corp., Tokyo, Japan) Group 2: Vitremer (3M ESPE, St. Paul, Minn., USA) Group 3: F2000 (3M ESPE, St. Paul, Minn., USA) Group 4: Z250 (3M ESPE, St. Paul, Minn., USA) Using density-measuring program, the micro-density of carious lesions on the specimens were measured. The mean density changes of each group were compared to the other groups to evaluate the effect of remineralization. The results were as follows: 1. The lesion density of all groups increased. 2. The mean density increase of Group 1, 2, 3 were higher than that of Group 4 every month(p<0.05). 3. There were significant differences of density increase among glass ionomer group(Group 1, 2, 3).

  • PDF

Different $^{18}$F-FDG Uptake According to Tumor location and Morphology of Cholangiocarcinoma and Its Clinical Implication (담관암의 위치와 형태에 따른 $^{18}$F-FDG 섭취량의 차이와 임상적 의의)

  • Lee, Won-Seok;Lee, Yoon-Jae;Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.317-322
    • /
    • 2009
  • Purpose: $^{18}$F-flurodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of $^{18}$F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. Materials and Methods: From April 2005 to May 2008, eighty two patients (M:F = 55:27, age 66.2$\pm$9.6 yrs) with CC underwent $^{18}$F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV$_{max}$) was obtained from the primary tumor. The difference of SUV$_{max}$ according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Results: Overall sensitivity of PET scan was 81.7% in CC. SUV$_{max}$ on PET scan in intrahepatic CC was significantly higher compared to extrahepatic CC. In extrahepatic CC, polypoid type showed significantly higher SUV$_{max}$ compared to scirrhous type. Conclusion: $^{18}$F-FDG PET may have a significant impact on clinical decision-making and on the management of intrahepatic cholangiocarcinoma. And it is related to the shape of the tumor and the sensitivity of detection is higher in the mass-forming type than in the scirrhous type.

Functional Magnetic Resonance Imaging of Brain Reactivity to Insomnia-Related vs. General Anxiety-Inducing Stimuli in Insomnia Patients with Subjective-Objective Discrepancy of Sleep (주관적-객관적 수면시간 차이를 보이는 불면증 환자에서 일반적 불안에 비해 불면증 관련 자극으로 인한 뇌활성에 관한 기능적 자기공명영상 연구)

  • Kim, Nambeom;Lee, Jae Jun;Cho, Seo-Eun;Kang, Seung-Gul
    • Sleep Medicine and Psychophysiology
    • /
    • v.27 no.1
    • /
    • pp.24-31
    • /
    • 2020
  • Objectives: Subjective-objective discrepancy of sleep (SODS) is a common symptom and one of the major phenotypes of insomnia. A distorted perception of sleep deficit might be related to abnormal brain reactivity to insomnia-related stimuli. We aimed to investigate differences in brain activation to insomnia-related stimuli vs. general anxiety-inducing stimuli among insomnia patients with SODS, insomnia patients without SODS, and healthy controls (HCs). Methods: All participants were evaluated for subjective sleep status using a sleep diary and questionnaires; occult sleep disorders and objective sleep status were assessed using polysomnography and actigraphy. Task functional magnetic resonance imaging was performed during insomnia-related stimuli (Ins) and general anxiety-inducing stimuli (Gen). Brain reactivity to Ins versus Gen was compared among insomnia with SODS, insomnia without SODS, and HC groups, and a combined insomnia disorder group (ID, insomnia with and without SODS) was also compared with HCs. Results: In the insomnia with SODS group compared to the insomnia without SODS group, the right precuneus and right supplementary motor areas showed significantly increased BOLD signals in response to Ins versus Gen. In the ID group compared to the HC group, the left anterior cingulate cortex showed significantly increased BOLD signals in response to Ins versus Gen. Conclusion: The insomnia with SODS and ID groups showed higher brain activity in response to Ins versus Gen, while this was not observed in the insomnia without SODS and HC groups, respectively. These results suggest that insomnia patients with sleep misperception are more sensitive to sleep-related threats than general anxiety-inducing threats.

Evaluation of Virtual Grid Software (VGS) Image Quality for Variation of kVp and mAs (관전압과 관전류량 변화에 대한 가상 그리드 소프트웨어(VGS) 화질평가)

  • Chang-gi Kong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.725-733
    • /
    • 2023
  • The purpose of this study is to evaluate the effectiveness of virtual grid software (VGS). The purpose of this study is to evaluate the changes in energy and object thickness by dividing the use of VGS into two cases (Without-VGS) without using a movable grid. We attempted to determine the effectiveness of VGS by acquiring images using a chest phantom and a thigh phantom and analyzing SNR and CNR. In the chest phantom and femoral phantom, the tube flow was fixed at 2.5 mAs, and the tube voltage was changed by 10 kVp from 60 to 100 kVp to measure SNR and CNR, and SNR was about 1.09 to 8.86% higher in the chest phantom than in Without-VGS, and CNR was 4.18 to 14.56% higher in the VGS than in Without-VGS. And in the femoral phantom, SNR was about 9.78 to 18.05% higher in VGS than in Without-VGS, and CNR was 21.07 to 44.44% higher in VGS than in Without-VGS. The tube voltage was fixed at 70 kVp in the chest phantom and the femoral phantom, and the amount of tube current was changed at 2.5 to 16 mAs, respectively, and after X-ray irradiation, SNR and CNR were measured in the chest phantom, which was about 1.49 to 11.11% higher in VGS than in Without-VGS, and CNR was 4.76 to 13.40% higher in VGS than in Without-VGS. And in the femoral phantom, SNR was about 2.22 to 17.38% higher in VGS than in Without-VGS, and CNR was 13.85 to 40.46% higher in VGS than in Without-VGS. Therefore, if an inspection is required with a mobile X-ray imaging device, it is believed that good image quality can be obtained by using VGS in an environment where it is difficult to use a mobile grid, and it is believed that the use of mobile X-ray devices can be increased.

Development of Formulas for the Estimation of Renal Depth and Application in the Measurement of Glomerular Filtration Rate in Koreans (사구체 여과율 측정을 위한 한국인의 신장 깊이에 관한 방정식 도출과 이용)

  • Yoo, Ie-Ryung;Kim, Sung-Hoon;Chung, Yong-An;Jung, Hyun-Seok;Lee, Hae-Giu;Park, Young-Ha;Lee, Sung-Yong;Sohn, Hyung-Seon;Chung, Soo-Kyo;Kim, Hyun-Mi;Lee, Hyung-Goo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.418-425
    • /
    • 2000
  • Purpose: There is no established formula for estimating renal depths in Korean. As a result, we undertook this study to develop a new formula, and to apply this formula in the calculation of glomerular filtration rate (GFR). Materials and Methods: We measured the renal depth (RD) on the abdominal CT obtained in 300 adults (M:F: 167:133, mean age 50.9 years) without known renal diseases. The RDs measured by CT were compared with the estimated RDs based on the Tonnesen and Taylor equations. New formulas were derived from the measured RDs in 200 out of 300 patients based on several variables such as sex, age, weight, and height by multiple regression analysis. The RDs estimated from the new formulas were compared with the measured RDs in the remaining 100 patients as a control. In 48 patients who underwent Tc-99m DTPA renal scintigraphy, GFR was measured with three equations (new formula, Tonnesen and Taylor equations), respectively, and compared with each other. Results: The mean values of the RDs measured from CT were 6.9 cm for right kidney of the men (MRK), 6.7 cm for left kidney of the men (MLK), 6.7 cm for right kidney of the women (WRK), and 6.6 cm for left kidney of the women (WLK). The RDs estimated from Tonnesen equation were shorter than the ones measured from CT significantly. The newly derived formulas were 12.813 (weight/height)+0.002 (age)+ 2.264 for MRK, 15.344 (weight/height)+0.011 (age)+0.557 for MLK, 12.936 (weight/height)+ 0.014 (age)+1.462 for WRK and 13.488 (weight/height)+0.019 (age)+0.762 for WLK. The correlation coefficients of the RD measured from CT and estimated from the new formula were 0.529 in MRK, 0.729 in MLK, 0.601 in WRK, and 0.724 in WLK, respectively. The GFRs from the new formula were significantly higher than those from the Tonnesen equation significantly, which was the most similar to normal GFR values. Conclusion: We generated new formulas for estimating RD in Korean from the data by CT. By adopting these formulas, we expect that GFR can be measured by the Gates method accurately in Korean.

  • PDF

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Development of Dual Reporter System of Mutant Dopamine 2 Receptor ($D_2R$) and Sodium Iodide Symporter (NIS) Transgenes (변이 도파민 2 수용체와 나트륨 옥소 공동 수송체 이입유전자의 이중 리포터시스템 개발)

  • Hwang, Do-Won;Lee, Dong-Soo;Kang, Joo-Hyun;Chang, Young-Soo;Kim, Yun-Hui;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.294-299
    • /
    • 2004
  • Purpose: Both human NIS and mutant $D_2R$ transgenes are proposed as reporting system in transplanted cell tracking. Using hepatoma cell lines, we constructed a dual reporter system containing human sodium-iodide symporter (hNIS) and dopamine 2 receptor ($D_2R$) and compared its characteristics. Materials and Methods: The recombinant plasmid ($pIRES-hNIS/D_2R$) was constructed with IRES (internal ribosome entry site) under control of the CMV promoter $pIRES-hNIS/D_2R$ was transfected to human hepatoma SK-Hep1 cell line with lipofectamine. HEP-ND ($SK-Hep1-hNIS/D_2R$) cells stably expressing hNIS and $D_2R$ was established by selection with G418 for two weeks. RT-PCR was performed to investigate the expression of both hNIS and $D_2R$ genes. The expressions of hNIS and $D_2R$ were measured by $^{125}I$ uptake assays and receptor binding assays. Specific binding of $D_2R$ to $[^3H]spiperone$ was verified by Scatchard plot with (+) butaclamol as a specific inhibitor. $K_d\;and\;B_{max}$ values were estimated. The correlation between hNIS and $D_2R$ expression was compared by using each clone. Results: Similar quantities of hNIS and $D_2R$ genes were expressed on HEP-ND as RT-PCR assays. HEP-ND cells showed 30 to 40 fold higher radioiodine uptakes than those of parental SK-Hep1 cells. $^{125}I$ uptake in HEP-ND cells was completely inhibited by $KClO_4$, a NIS inhibitor Specific binding to HEP-ND cells was saturable and the $K_d\;and\;B_{max}$ values for HEP-ND cells were 2.92 nM, 745.25 fmol/mg protein and 2.91nM, 1323 fmole/mg protein in two clones, respectively. The radioiodine uptake by hNIS activity and $D_2R$ binding was highly correlated. Conclusion: We developed a dual positron and gamma imaging reporter system of hNIS and $D_2R$ in a stably transfected cell line. We expect that $D_2R$ and hNIS genes can complement mutually as a nuclear reporting system or that $D_2R$ can be used as reporter gene when hNIS gene were used as a treatment gene.