• Title/Summary/Keyword: 영상 균일성

Search Result 195, Processing Time 0.022 seconds

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

A Study on Temperature Change Profiles by Land Use and Land Cover Changes of Paddy Fields in Metropolitan Areas (대도시 외곽지역 논경작지의 토지이용 및 피복변화에 따른 온도 변화모형 연구)

  • Ki, Kyong-Seok;Lee, Kyong-Jae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.18-27
    • /
    • 2009
  • The purpose of this study is to understand the scale of temperature change following large-scale urban developments in paddy fields to present possible measures to preserve suburban area paddy fields and to lower the scale of temperature increase after developing paddy fields in urban areas. The study was conducted in Bupyeong and Bucheon of Incheon Metropolitan City. The satellite image($1989{\sim}2000$) before and after the development of old paddy fields were used to analyze the land surface temperature changes according to the land use types. Building coverage, green coverage, non-permeable pavement coverage, and floor area ratio(FAR) were selected as the factors that influence urban temperature changes and the temperature estimation model was constructed by using correlation and regression analyses. The before and after satellite images of Bupyeong and Bucheon were classified into forests, greens and plantations, paddy fields, unused lands, and urban areas. The results indicate that most of the paddy fields that existed in the center of Bupyeong and Bucheon were converted into unused lands which were undergoing construction to become new urban areas. The difference between the surface temperatures of May 17th, 1989 and May 7th, 2000 was analyzed to reveal that most land converted from paddy fields to unused lands or urban areas saw an increase in surface temperature. Han River was used as a comparison to analyze the average surface temperature changes($1989{\sim}2000$) in former paddy fields. The scale of temperature changes were: $+1.6697^{\circ}C$ in urban parks; $+2.5503^{\circ}C$ in residential zones; $+2.9479^{\circ}C$ on public lands, $+3.0385^{\circ}C$ in commercial zones, and $+3.1803^{\circ}C$ in educational zones. The correlation between building coverage, green coverage, non-permeable pavement coverage, or floor area ratio(FAR) and surface temperature increases was also analyzed. The green coverage to temperature increases, but building coverage, non-permeable pavement coverage, and floor area ratio(FAR) had no statistically significant temperature increases. The factors that influence urban temperature changes were set up as independent variables and the surface temperature changes as dependent variables to construct a surface temperature change model for the land use types of former paddy fields. As a result of regression analysis, green coverage was selected as the most significant independent variable. According to regression analysis, if farmland is converted into an urban area, a temperature increase of $+3.889^{\circ}C$ is anticipated with 0% green coverage. The temperature saw a decrease of $-0.43^{\circ}C$ with every 10% increase of green coverage.

One dimensional diffusion of NaCl in flooded soil systems (담수(湛水) 토양계(土壤系)에서 염분(鹽分)의 일차원적(一次元的) 확산(擴散))

  • Oh, Yong-Taeg;Yoo, Sun-Ho;Jung, Yeong-Sang;Hong, Chong Woon;Park, Chun Suh
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.9 no.1
    • /
    • pp.1-8
    • /
    • 1976
  • 1. Under an asumption that Ficks diffusion equation could be applicable in soil systems, the diffusivities of NaCl in several flooded soil systems were measured to range from $0.4{\times}10^{-5}cm^2sec^{-1}$ to $0.83{\times}10^{-5}cm^2sec^{-1}$ 2. It was discussed that, when a polder soil with a uniform initial salt content through the profile is desalinated only by diffusion to flooding water, the salt content in profile is a function of soil depth, diffusion time, and diffusivity as following $$C=C^{\circ}erf\frac{x}{\sqrt[2]{Dt}}$$ 3. On the basis of Kirkham, et al's integration of complementary erra function, the speed of desalting was discussed to be inversely proportional to the square root of time as following $$dq/dt=C^{\circ}{\sqrt{D/{\pi}t}}$$ 4. It was estimated enough to exchange the flooding water once or twice, even when desalination of polder soil is carried out only by diffusion, if the desalination begins in June, the used flooding water is fresh water, and flooding depth is 10cm. 5. Desalination of polder soil by diffusion requires 2 month for good standing of planted rice.

  • PDF

An Electrical Conductivity Reconstruction for Evaluating Bone Mineral Density : Simulation (골 밀도 평가를 위한 뼈의 전기 전도도 재구성: 시뮬레이션)

  • 최민주;김민찬;강관석;최흥호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.261-268
    • /
    • 2004
  • Osteoporosis is a clinical condition in which the amount of bone tissue is reduced and the likelihood of fracture is increased. It is known that the electrical property of the bone is related to its density, and, in particular, the electrical resistance of the bone decreases as the bone loss increases. This implies that the electrical property of bone may be an useful parameter to diagnose osteoporosis, provided that it can be readily measured. The study attempted to evaluate the electrical conductivity of bone using a technique of electrical impedance tomography (EIT). It nay not be easy in general to get an EIT for the bone due to the big difference (an order of 2) of electrical properties between the bone and the surrounding soft tissue. In the present study, we took an adaptive mesh regeneration technique originally developed for the detection of two phase boundaries and modified it to be able to reconstruct the electrical conductivity inside the boundary provided that the geometry of the boundary was given. Numerical simulation was carried out for a tibia phantom, circular cylindrical phantom (radius of 40 mm) inside of which there is an ellipsoidal homeogenous tibia bone (short and long radius are 17 mm and 15 mm, respectively) surrounded by the soft tissue. The bone was located in the 15 mm above from the center of the circular cross section of the phantom. The electrical conductivity of the soft tissue was set to be 4 mS/cm and varies from 0.01 to 1 ms/cm for the bone. The simulation considered measurement errors in order to look into its effects. The simulated results showed that, if the measurement error was maintained less than 5 %, the reconstructed electrical conductivity of the bone was within 10 % errors. The accuracy increased with the electrical conductivity of the bone, as expected. This indicates that the present technique provides more accurate information for osteoporotic bones. It should be noted that tile simulation is based on a simple two phase image for the bone and the surrounding soft tissue when its anatomical information is provided. Nevertheless, the study indicates the possibility that the EIT technique may be used as a new means to detect the bone loss leading to osteoporotic fractures.

The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning (유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석)

  • Cho Jae Ho;Cho Kwang Hwan;Keum Kichang;Han Yongyih;Kim Yong Bae;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.82-93
    • /
    • 2003
  • Purpose : To reduce the Irradiation dose to the lungs and heart in the case of chest wail irradiation using an oppositional electron beam, we used an Individualized custom bolus, which was precisely designed to compensate for the differences In chest wall thickness. The benefits were evaluated by comparing the normal tissue complication probablilties (NTCPS) and dose statistics both with and without boluses. Materials and Methods : Boluses were made, and their effects evaluated in ten patients treated using the reverse hockey-stick technique. The electron beam energy was determined so as to administer 80% of the irradiation prescription dose to the deepest lung-chest wall border, which was usually located at the internal mammary lymph node chain. An individualized custom bolus was prepared to compensate for a chest wall thinner than the prescription depth by meticulously measuring the chest wall thickness at 1 emf intervals on the planning CT Images. A second planning CT was obtained overlying the individuailzed custom bolus for each patient's chest wall. 3-D treatment planning was peformed using ADAC-Pinnacle$^{3}$ for all patients with and without bolus. NTCPS based on 'the Lyman-Kutcher' model were analyzed and the mean, maximum, minimum doses, V$_{50}$ and V$_{95}$ for 4he heari and lungs were computed. Results .The average NTCPS in the ipsliateral lung showed a statistically significant reduction (p<0.01), from 80.2${\pm}$3.43% to 47.7${\pm}$4.61%, with the use of the individualized custom boluses. The mean lung irradiation dose to the ipsilateral iung was also significantly reduced by about 430 cGy, Trom 2757 cGy to 2,327 cGy (p<0.01). The V$_{50}$ and V$_{95}$ in the ipsilateral lung markedly decreased from the averages of 54.5 and 17.4% to 45.3 and 11.0%, respectively. The V$_{50}$ and V$_{95}$ In the heart also decreased from the averages of 16.8 and 6.1% to 9.8% and 2.2%, respectively. The NTCP In the contralateral lung and the heart were 0%, even for the cases with no bolus because of the small effective mean radiation volume values of 4.4 and 7.1%, respectively Conclusion : The use of an Individualized custom bolus in the radiotherapy of postrnastectorny chest wall reduced the NTCP of the ipsilateral lung by about 24.5 to 40.5%, which can improve the complication free cure probability of breast cancer patients.