• Title/Summary/Keyword: 영상 검사

Search Result 3,141, Processing Time 0.027 seconds

Diagnostic Performance of Simulated Abbreviated MRI for Early-Stage Hepatocellular Carcinoma Screening: A Comparison to Conventional Dynamic Contrast-Enhanced MRI (초기 간암 선별 검사로서 단축 자기공명영상 검사의 진단능: 고식적 역동학적 자기공명영상검사와의 비교)

  • Eun Sol Lim;Sung Mo Kim;Sang Soo Shin;Suk Hee Heo;Jong Eun Lee;Yong Yeon Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1218-1230
    • /
    • 2021
  • Purpose To compare the per-patient diagnostic performance of simulated abbreviated MRI (AMRI) to that of conventional MRI (CMRI) with full-sequence dynamic gadoxetic acid (GA) enhancement for early-stage hepatocellular carcinoma (HCC) screening in high-risk patients. Materials and Methods A total of 201 consecutive patients at high-risk for HCC, who underwent 3T liver MRI, were included in this retrospective study. The AMRI protocol comprised T2-weighted imaging, hepatobiliary phase imaging after GA injection, and diffusion-weighted imaging. For each patient, two AMRI and CMRI image sets were independently reviewed by two radiologists. Inter-reader agreement was assessed using Cohen's kappa value. A composite reference standard was used to determine the diagnostic performance of each image set for each reader. Results A total of 93 HCCs were detected in 79 patients. The inter-reader agreement was almost perfect for both image sets (κ = 0.839, 0.948). In AMRI, the per-patient sensitivity and negative predictive values (NPV) were 94.9% and 96.4%, respectively. In CMRI, the per-patient sensitivity and NPV were 96.2% and 97.5%, respectively. Conclusion AMRI, using only three sequences, had a comparable diagnostic performance to CMRI in screening early-stage HCC. AMRI could be an alternative HCC screening tool for high-risk HCC patients.

Recent Advances in Abdominal MR Imaging

  • 김명진
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.25-34
    • /
    • 2001
  • 복부의 자기공명영상(Magnetic resonance imaging; MRI)은 주로 간 질환의 검사에서 다른 영상검사로 해결되지 않은 궁금점을 풀기 위한 보조적인 검사로 주로 사용하였으나, 최근 들어서는 병변의 발견 및 감별진단에 직접적인 검사로도 자주 이용하고 있으며, 담췌관 질환이나 위장관 검사 등에도 적용범위가 넓어지고 있다. 이는 그간의 하드웨어 및 소프트웨어상의 발달로 인해, 위장관 연동운동이나 호흡에 따른 인공물을 억제하면서도 해부학적인 세부구조는 자세하게 나타낼 수 있는 우수한 영상을 얻을 수 있음으로써 가능하게 되었다. 고속영상은 영상의 질을 우수하게 할 뿐 아니라, 검사시간을 단축시켜서 더 많은 환자를 검사할 수 있게 하고, 한자가 검사에 더 잘 적응할 수 있게 하여준다. 단발(single-shot)기법의 고속 T2강조영상은 담췌관이나 위장관등 그간 MRI를 적용하기 어려웠던 부위에 대한 검사가 가능하게 하였으며, 고속의 3차원 T1강조 펄스대열(pulse sequence)은 단면에 따른 오기록(misregistration)이나 운동인공물이 적으면서도, 향상된 다평면적인 영상구성을 얻을 수 있게 하였다. [l]. 본 강좌에서는 최근 수년간 복부 MRI의 응용을 증가할 수 있게 한 영상장치 및 펄스대열의 발전과 최근 국내에 시판이 허용되어 사용이 증가되고 있는 새로운 간자기공명조영제에 관해서 살펴보고자 한다.

  • PDF

A Study on Abdomen MRI Scan Using Metronome (메트로놈을 이용한 복부 MRI 검사에 대한 연구)

  • Park, Ho-Sung;Kim, Jae-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1138-1143
    • /
    • 2020
  • MRI scans in the abdominal area are difficult to achieve optimal images due to artificial respiration. Among 45 patients (male:female = 30:15) who underwent abdominal MRI examination, a metronome-based examination method was studied for patients whose breathing is difficult and difficult to examine. The images examined without using a metronome were divided into group A, and the images examined using a metronome were divided into group B. Image quality improvement (30%) and inspection time (approximately 50 seconds) were reduced in images using metronome. During abdominal magnetic resonance imaging (ABD MRI), the images examined using a metronome had differences in quality and examination time compared to the unused images. It is more effective to use a metronome brace that controls the patient's respiratory rate during abdominal magnetic resonance imaging under respiratory induction in patients with difficulty in respiratory-gated.

영상처리를 이용한 이차원 형상측정

  • 김희식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.193-198
    • /
    • 2001
  • 생산현장 업무에서는 측정검사업무의 비중이 크다. 측정검사의 업무는 품질향상을 위한 활동이며 또한 고부가가치의 제품을 위해서도 중요하다. 고품질 고정밀도는 철저한 측정검사를 통하여 이루어진다. 제품의 치수를 정확히 측정하여 정밀도 있는 부품을 제작하고 불량부품이나 파손된 부품을 검사하여 제거함으로써 제품의 성은과 품질이 우수하게 인정된다. 이러한 측정검사작업의 정밀도향상, 생산성 향상을 위해서는 자동화가 필요하다. 측정검사의 자동화 (CAT : Computer Aided Testing)에는 영상처리를 이용하는 시각검사의 자동화가 중요한 분야이다. 영상처리를 이용한 시각검사의 대상은 결함검사, 두께검사, 형상칫수 검사, 물체의 위치, 방향, 종류의 파악 등이 있다.

선박의 원격검사를 위한 아날로그 게지이의 정량화에 관한 기초연구

  • 이현우;임정빈
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.105-106
    • /
    • 2023
  • 이 연구는 원격검사의 한 방법으로서, 특히 자율운항 선박에서 컴퓨터비전을 이용한 영상처리를 통한 원격 검사방법에 관한 것이다. 자율운항 선박은 자율화의 정도에 따라 다르지만, 선원이 승선하지 않거나 최소한의 선원만 승선하는 선박이므로 선박의 검사방법에 변화가 필요한 실정이다. 따라서 컴퓨터비전을 이용한 영상처리에 대한 이론적 배경을 바탕으로 원격검사 항목 중에서 아날로그 게이지의 정량화에 필요한 영상의 전처리 방법에 관한 연구이다. 아날로그 게이지의 정량화를 위해서 사용한 방법은 흑백처리, 가우시안필터, 임계화처리, 모폴로지 연산이다. 이 연구를 통하여 영상의 전처리 결과 배경과 객체를 비교적 명확하게 분류할 수 있었으며, 영상처리 과정 중 추가로 발생한 잡음을 효과적으로 제거할 수 있었다. 이를 통하여 영상에서 주된 객체인 지시바늘과 눈금판의 숫자를 인식에 필요한 이미지 전처리 방법을 제시하였으며, 나아가 컴퓨터 비전을 이용한 원격검사 방법은 아날로그 게이지뿐만 아니라 비상차단밸브, 통풍폐쇄장치, 고정식 소화장치 등 여러 방면에서 사용될 것이라 기대한다.

  • PDF

Interpretation of Image-Guided Biopsy Results and Assessment (영상유도하 조직검사의 해석과 판정)

  • Su Min Ha;Jung Min Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.361-371
    • /
    • 2023
  • The success of image-guided breast biopsy depends on the biopsy method, needle selection, and appropriate technique based on the accurate judgment by the radiologist at biopsy. However, insufficient or inappropriate sampling of specimens may result in false-negative results or pathologic underestimation. Therefore, image-pathology concordance assessments after biopsy are essential for appropriate patient management. Particularly, the assessment of image-pathology concordance can avoid false-negative reports of breast cancer as a benign pathology. Therefore, this study aimed to discuss factors that impact the accurate interpretation of image-guided breast biopsy along with the appropriate assessments.

Korean Clinical Imaging Guidelines for Justification of Diagnostic Imaging Study for COVID-19 (한국형 COVID-19 흉부영상 진단 시행 가이드라인)

  • Kwang Nam Jin;Kyung-Hyun Do;Bo Da Nam;Sung Ho Hwang;Miyoung Choi;Hwan Seok Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.265-283
    • /
    • 2022
  • To develop Korean coronavirus disease (COVID-19) chest imaging justification guidelines, eight key questions were selected and the following recommendations were made with the evidence-based clinical imaging guideline adaptation methodology. It is appropriate not to use chest imaging tests (chest radiograph or CT) for the diagnosis of COVID-19 in asymptomatic patients. If reverse transcription-polymerase chain reaction testing is not available or if results are delayed or are initially negative in the presence of symptoms suggestive of COVID-19, chest imaging tests may be considered. In addition to clinical evaluations and laboratory tests, chest imaging may be contemplated to determine hospital admission for asymptomatic or mildly symptomatic un-hospitalized patients with confirmed COVID-19. In hospitalized patients with confirmed COVID-19, chest imaging may be advised to determine or modify treatment alternatives. CT angiography may be considered if hemoptysis or pulmonary embolism is clinically suspected in a patient with confirmed COVID-19. For COVID-19 patients with improved symptoms, chest imaging is not recommended to make decisions regarding hospital discharge. For patients with functional impairment after recovery from COVID-19, chest imaging may be considered to distinguish a potentially treatable disease.

Diffusion-Weighted Imaging as a Stand-Alone Breast Imaging Modality (독립적 검사 방법으로서의 확산강조 자기공명영상검사)

  • Hee Jung Shin;Su Hyun Lee;Woo Kyung Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.29-48
    • /
    • 2021
  • Diffusion-weighted magnetic resonance imaging (DW MRI) is a fast unenhanced technique that shows promise as a stand-alone modality for cancer screening and characterization. Currently, DW MRI may have lower sensitivity than that of dynamic contrast-enhanced MRI as a standalone modality for breast cancer detection but superior to that of mammography, which may provide a useful alternative for supplemental screening. Standardized acquisition and interpretation of DW MRI can improve the image quality and reduce the variability of the results. Furthermore, high-resolution DW MRI, with advanced techniques and postprocessing, will facilitate better detection and characterization of subcentimeter cancers and reduce false-negatives and false-positives. Future results from ongoing prospective multicenter clinical trials using standardized and optimized protocols will facilitate the use of DW MRI as a stand-alone modality.

Z-Score를 이용한 관류영상과 조영전후 감산에 의한 역동영상의 뇌관류 양상의 비교 관찰

  • 최순섭;오종영;남경진;이영일
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.171-171
    • /
    • 2001
  • 목적: 뇌 자기공명영상에서 Z-score를 이용한 관류 영상과 조영전후의 감산에 의한 역동 영상의 관류 양상을 비교 관찰 하고자 한다. 대상 및 방법: 뇌 자기공명영상에서 이상 소견이 없는 젊은 환자 1명, Moya moya 환자 1, 중대뇌동맥 폐색 환자 1명, 외상후 증후군 1명, 뇌종양 1예를 대상으로 하여, 뇌의 routine 자기공명 영상과 함께 Gd-DTPA 0.1 mmol/kg를 급속 주사 후 자화율 대조 EPI 영상을 얻었다. 영상 기기는 Magnetom Vision(Siemens Medical Systems, Erlangen, Germany)이며, EPI 영상 지표들은 TR/TE는 0.8/29 msec, slice 두께 6 mm, slice 수 10, 화소수 128 $\times$ 128, FOV 215 $\times$ 215 mm, 영상획득 1 회, 1회 검사시간 1.32 초, 검사수 30 회로서, 총 검사시간은 40 초였다. 검사 후 영상처리(post processing)는 Magnetom Vision의 VB31D 자체 프로그램을 이용하였는데, 2-score를 이용한 관류영상은 조영제 유입전 영상들, 조영제 최대 유입기 영상들, 그리고 조영제 배출기 영상들 4-5 회를 각각 한 군으로 하여, Z-score 1.2에서 2.0 사이에서 여러번 반복하여 영상을 재구성하였다. 감산에 의한 역동영상은 조영제 도달 전의 영상으로부터 조영제 유입 후의 영상을 차례로 빼어서 영상을 재구성하였으며, 이들 영상을 재정리하여 각 단면의 시간 경과에 따른 관류 양상을 연속하여 관찰하였다 두 방법에 의한 영상 재구성은 각각 약 10분 정도가 소요되었다.

  • PDF

A Study on the Reliability of Clinical Diagnosis for TMJ Internal Derangement (측두하악관절 내장증의 임상적 진단의 신뢰도에 관한 연구)

  • 김영구;이승우;정성창
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.37-44
    • /
    • 1998
  • 본연구는 서울대학교 치과병원 구강진단과 악안면 동통진료실에 내원한 환자 중 임상적 검사에 의해 악관절 내장증으로 진단된 총 32명 53개의 측두하악 관절을 대상으로 악관절 조영술이나 자기공명영상을 실시하여 임상적 진단의 정확도를 알아보고 향후 이 결과를 적절히 활용하여 정확한 적응증의 설정에 도움을 주고자 시행되었다. 각 악관절을 임상적 검사, 조영술 및 자기공명영상 검사를 기준으로 정상, 정복성 관절원판 변위, 비정복성 관절원판 변위, 퇴행성 관절 질환을 동반한 정복성 관절원판 변위, 퇴행성 관절 질환을 동반한 비정복성 관절원판 변위로 구분하였다. 이상의 연구를 통하여 다음과 같은 결론을 얻었다. 1. 악관절 내장증으로 내원한 환자 32명, 총 53개 관절중, 정상인 경우가 5예, 정복성 관절원판 변위인 경우가 33예, 비정복성 관절원판 변위인 경우가 14예, 퇴행성 관절 질환을 동반한 정복성 관절원판변위인 경우가 1예이었고, 퇴행성 관절 질환을 동반한 비정복성 관절원판 변위인 경우는 없었다. 2. 악관절 조영술 검사를 시행한 35개의 관절중 임상적 검사와 일치하는 경우는 32개로 그 일치율은 91.1%이었으며, 자기공명영상 검사를 시행한 28개의 관절중 임상적 검사와 일치하는 경우는 20개로 그 일치율은 71.4%이었다. 3. 악관절 조영술 및 자기공명영상 검사를 동시에 시행한 10개 관절중 악관절 조영술 및 자기공명영상검사가 일치하는 경우는 9개이었으며 이중 8개 결과는 임상적 진단과 일치되는 소견을 보였다. 임상적 검사는 악관절 내장증의 진단에 유용한 방법임이 확인되었다. 그러나 임상적으로는 정상으로 진단되었지만 주관적인 증상을 가진 환자에게는 자기공명영상 검사와 악관절조영술 검사 등의 영상진단술식이 필요할 것으로 사료된다.

  • PDF