• Title/Summary/Keyword: 영상화질평가

Search Result 481, Processing Time 0.022 seconds

Fast Motion Estimation Using Multiple Reference Pictures In H.264/Avc (H.264/AVC에서 다중 참조 픽처를 이용한 고속 움직임 추정)

  • Kim, Seong-Hee;Oh, Jeong-Su
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5C
    • /
    • pp.536-541
    • /
    • 2007
  • In video coding standard H.264/AVC, motion estimation using multiple reference pictures improves compression efficiency but the efficiency depends upon image content not the number of reference pictures. So, the motion estimation includes a large amount of computation of no worth according to image. This paper proposes fast motion estimation algorithm that removes worthless computation in the motion estimation using multiple reference pictures. The proposed algorithm classifies a block into valid and invalid blocks for the multiple reference pictures and removes the workless computation by applying a single reference picture to the invalid block. To estimate the proposed algorithm's performance, image quality, bit rate, and motion estimation time are compared with ones of the conventional algorithm in the reference software JM 9.5. The simulation results show that the proposed algorithm can considerably save about 38.67% the averaged motion estimation time while keeping the image quality and the bit rate, whose are average values are -0.02dB and -0.77% respectively, as good as the conventional algorithm.

A Fast Resource Reallocation Protocol (FRRP) for rt-VBR MPEG-2 video services over ATM Networks (ATM 상에서 실시간 가변비트율 MPEG-2 동영상 서비스를 위한 고속 자원 재할당 프로토콜)

  • 홍승은;장경훈;김덕진;고성제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1426-1437
    • /
    • 1999
  • The introduction of fast packet switching networks such as the ATM leads to the possibility of video services with constant quality. However, the fixed traffic descriptor(TD), which is defined by ATM Forum and ITU-T, can not simultaneously satisfy network efficiency and video quality. This paper presents fast resource reallocation protocol (FRRP) which can provide an effective compromise between network efficiency and video quality. This protocol reallocates the network resources and then adapts the traffic to the reallocated resources. In the proposed method, a video session is divided into several time-intervals according to its generated traffic and TD is calculated which well characterizes the traffic during the specific subdivided interval. In addition, a system model, where MPEG coding algorithm and network control are unified, is proposal and the performance of the FRRP in terms of cell loss rate(CLR) is evaluated though the simulation using real video traffic(Star Wars). Simulation results show that the FRRP has only 5 ~35% CLR of the fixed TD.

  • PDF

Time-optimized Color Conversion based on Multi-mode Chrominance Reconstruction and Operation Rearrangement for JPEG Image Decoding (JPEG 영상 복원을 위한 다중 모드 채도 복원과 연산 재배열 기반의 시간 최적화된 컬러 변환)

  • Kim, Young-Ju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.1
    • /
    • pp.135-143
    • /
    • 2009
  • Recently, in the mobile device, the increase of the need for encoding and decoding of high-resolution images requires an efficient implementation of the image codec. This paper proposes a time-optimized color conversion method for the JPEG decoder, which reduces the number of calculations in the color conversion by the rearrangement of arithmetic operations being possible due to the linearity of the IDCT and the color conversion matrices and brings down the time complexity of the color conversion itself by the integer mapping replacing floating-point operations to the optimal fixed-point shift and addition operations, eventually reducing the time complexity of the JPEG decoder. And the proposed method compensates a decline of image quality incurred by the quantification error of the operation arrangement and the integer mapping by using the multi-mode chrominance reconstruction. The performance evaluation performed on the development platform of embedded systems showed that, compared to previous color conversion methods, the proposed method greatly reduces the image decoding time, minimizing the distortion of decoded images.

A Performance Evaluation Method of Image Scaling Algorithms (이미지 스케일링 알고리즘의 성능 평가)

  • Eun, Jin-Hwa;Kwon, Byoung-Heon;Choi, Myung-Ryul
    • Annual Conference of KIPS
    • /
    • 2001.04b
    • /
    • pp.875-878
    • /
    • 2001
  • 본 논문에서는 디지털 영상의 확대 및 축소에 필요한 보간 방식들에 대한 성능을 평가하는 방법에 대하여 논하였다. 본 논문에서 비교한 성능 평가 방법에는 PSNR 비교와 에지(edge) 특성 비교, 그리고 화소 값이 다른 화소수 비교와 Binary 이미지를 이용한 비교 방법들이 있으며, 이러한 비교 방법들은 보간된 이미지의 특성에 따라 각각의 장, 단점을 가지고 있다. 본 논문에서는 각 평가 방법이 어떠한 특성의 화질을 평가하는데 유용한지 컴퓨터 시뮬레이션을 통해 비교 분석하였다.

  • PDF

Comparison of DICOM images and various types of images (DICOM 영상과 다양한 형식의 영상 비교)

  • Kim, Ji-yul;Ko, Seong-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.2
    • /
    • pp.76-83
    • /
    • 2017
  • In this study, the original medical image, DICOM file, was converted into TIFF, BITMAP, GIF, JPEG image file, and then the conversion loss ratio according to the image compression and conversion process was quantitatively evaluated using Origin pro and ICY image analysis program. As the evaluation method, 50% MTF, structural similarity index, MSE, RMSE, maximum signal - to - noise ratio and so on were evaluated. The TIFF image file showed the same result as DICOM image in all experimental groups, Image file format. In this study, we propose a new method for evaluating the quality of digital images by applying original evaluation program such as Origin pro or ICY medical image analysis program. Is expected to be used as research data in the field of medical image processing, and TIFF image file showing the same result as DICOM image in the basic research field using digital medical image and evaluation program that does not support DICOM file Therefore, it is believed that it will help to secure reliability in digital medical image processing research using image file.

  • PDF

Analysis between elemental image size and object locations in the pickup using periodically-distributed lenslets and enhancement of computational integral imaging (주기적으로 배치된 렌즈 배열 픽업에서의 요소 영상 크기와 3차원 물체 위치와의 해석과 컴퓨터 집적 영상 복원 화질 개선 방법)

  • Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.5
    • /
    • pp.1171-1176
    • /
    • 2011
  • This paper describes an analysis on the relationship between elemental image size and object locations in the computational integral imaging reconstruction and in the pickup using a periodically-distributed lenslet array. A sparse sampling effect arises from a periodically-distributed lenslet array in the pickup of 3D objects. The relationship between elemental image size and object location is also reported. Based on the analysis, a method to eliminate the sparse sampling is proposed. To show the effectiveness of the proposed method, experimental results are carried out. It turns out that the theory works.

Evaluation of Image Quality When Using Grid During Child Chest X-Ray Examination (소아 흉부검사 시 격자 사용에 따른 영상 화질 평가)

  • Jeung, Seung-Hun;Han, Beom-Hul;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.371-376
    • /
    • 2017
  • Since in case of children, they are sensitive to the radiation compared to the adult and the potential exposure damage lasts longer, the exposure dose should be managed better than for the adult. Therefore, this study was conducted to observe the change in the chest x-ray image by the use of grid, which eliminates the scattering rays but increases the exposure dose during the child chest x-ray examination. As a research method, SNR, CNR and V. Vuichi were measured at 100 cm and 180 cm with the grid varying the kVp to 70, 90 and 110. In addition, SNR, CNR and V. Vuichi were measured fixing 100 cm and 180cm without grid and varying the dose to 6, 8 and 10 mAs. In the results of measuring them by fixing kVp, SNR, VNR and V. Vuichi were represented high when FID is 100cm. And in the results of meaduring them varying mAs, SNR, VNR and V. Vuichi were represented high when FID is 100cm. Currently in our country, the chest x-ray examination is performed at 180 cm. However, as the image is measured high when FID is 100 cm, in case of child, FID is deemed to be 100 cm.

Dose Reduction and Image Quality Assessment of the CareDose 4D Technique on Abdomen Liver Computed Tomography (복부 간 CT 검사에서 CareDose 4D 사용에 따른 선량 감소 및 화질 평가)

  • Seok, Jong-Min;Jeon, Woo-Jin;Park, Young-Joon;Lee, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • The purpose of this study was to evaluate the clinical efficacy of 128 MDCT (multi-detector computed tomography) for reducing the CareDose 4D dose and comparing the image quality with the fixed tube current technique. For this purpose, we conducted the phantom and clinical studies to evaluate the exposure dose and image of the subject before and after applying the CareDose 4D system in abdominal examination using 128 MDCT. In the phantom study, ROI (Region of interest) was located at the center, 3, 6, 9, 12 o'clock, into two groups: group A without CareDose 4D and Group B applied were measured. In the clinical study, ROI was located at the liver 8 segments, divided into two groups too. The measured items were CT number, noise, and dose length product (DLP) dose. The result of CTDIvol (CT Dose Index volume) measurements in phantom and clinical studies were lower than those before CareDose 4D application, and dose and effective dose were also measured lower (p<.05). There was no difference in CT number before and after application (p>.05). In conclusion, using CareDose 4D, we can obtain optimal image information without deteriorating image quality while reducing patient dose.

Evaluation of Radiation Dose and Image Quality Between Manual and Automatic Exposure Control Mode According to Body Mass Index in Cardiac CT (체질량지수에 따른 심장 CT검사의 수동노출조절 방법과 자동노출조절 방법의 방사선량 및 화질 평가)

  • Kim, Hyeong-Jin;Moon, Il-Bong;Han, Jae-Bok;Choi, Nam-Gil;Jang, Seong-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.290-299
    • /
    • 2013
  • This study included 198 patients who underwent prospectively electrocardiogram-triggered high-pitch spiral mode(FLASH mode) in cardiac CT for health check: 123 patients who underwent manual exposure control(Group A) and 75 patients who underwent automatic exposure control(Group B). Patients were classified according to BMI grades: Grade 1, Grade 2, Grade 3, Grade 4. Radiation dose, objective and subjective image quality between two groups were compared. In Group B, tube voltage were significantly decreased in all BMI grades. Both $CTDI_{vol}$ and effective dose were significantly reduced in the BMI Grade 1, 3, and 4 whereas they were slightly reduced in the Grade 2(p>0.05), SNR was significantly decreased in the Grade 1 and increased in the Grade 3(p<0.05), but there was no significant difference in the Grade 2, 4 between the two groups(p>0.05). CNR was significantly decreased in the Grade 1(p<0.05), and there was no significant difference in the Grade 2, 3, 4 between the two groups(p>0.05). The subjective image quality showed no significant difference in all BMI Grades between the two groups(p>0.05). Automatic exposure control can lead to a significant reduction of radiation exposure dose without degradation of subjective image quality.

Post-filtering in Low Bit Rate Moving Picture Coding, and Subjective and Objective Evaluation of Post-filtering (저 전송률 동화상 압축에서 후처리 방법 및 후처리 방법의 주관적 객관적 평가)

  • 이영렬;김윤수;박현욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1518-1531
    • /
    • 1999
  • The reconstructed images from highly compressed MPEG or H.263 data have noticeable image degradations, such as blocking artifacts near the block boundaries, corner outliers at cross points of blocks, and ringing noise near image edges, because the MPEG or H.263 quantizes the transformed coefficients of 8$\times$8 pixel blocks. A post-processing algorithm has been proposed by authors to reduce quantization effects, such as blocking artifacts, corner outliers, and ringing noise, in MPEG-decompressed images. Our signal-adaptive post-processing algorithm reduces the quantization effects adaptively by using both spatial frequency and temporal information extracted from the compressed data. The blocking artifacts are reduced by one-dimensional (1-D) horizontal and vertical low pass filtering (LPF), and the ringing noise is reduced by two-dimensional (2-D) signal-adaptive filtering (SAF). A comparison study of the subjective quality evaluation using modified single stimulus method (MSSM), the objective quality evaluation (PSNR) and the computation complexity analysis between the signal-adaptive post-processing algorithm and the MPEG-4 VM (Verification Model) post-processing algorithm is performed by computer simulation with several MPEG-4 image sequences. According to the comparison study, the subjective image qualities of both algorithms are similar, whereas the PSNR and the comparison complexity analysis of the signal-adaptive post-processing algorithm shows better performance than the VM post-processing algorithm.

  • PDF