• Title/Summary/Keyword: 영상의평가

Search Result 1,538, Processing Time 0.031 seconds

Imaging for Multiple Myeloma according to the Recent International Myeloma Working Group Guidelines: Analysis of Image Acquisition Techniques and Response Evaluation in Whole-Body MRI according to MY-RADS (International Myeloma Working Group의 최신 가이드 라인에 따른 다발성 골수종의 영상검사법 및 MY-RADS에 따른 전신 MRI에서의 영상 획득과 반응 평가 소개)

  • A Yeon Son;Hye Won Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.150-169
    • /
    • 2023
  • Multiple myeloma (MM) is a malignant hematologic disease caused by the proliferation of clonal plasma cells in the bone marrow, and its incidence is increasing in Korea. With the development of treatments for MM, the need for early diagnosis and treatment has emerged. In recent years, the International Myeloma Working Group (IMWG) has been constantly revising the laboratory and radiological diagnostic criteria for MM. In addition, as whole-body MRI (WBMR) has been increasing used in the diagnosis and treatment response evaluation of patients with MM, the Myeloma Response Assessment and Diagnosis System (MY-RADS) was created to standardize WBMR image acquisition techniques, image interpretation, and response evaluation methods. Radiologists need to have a detailed knowledge of the features of MM for accurate diagnosis. Thus, in this review article, we describe the imaging method for MM according to the latest IMWG guidelines as well as the image acquisition and response evaluation technique for WBMR according to MY-RADS.

A Vehicle Model Recognition using Car's Headlights Features and Homogeneity Information (차량 헤드라이트 특징과 동질성 정보를 이용한 차종 인식)

  • Kim, Mih-Ho;Choi, Doo-Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.10
    • /
    • pp.1243-1251
    • /
    • 2011
  • This paper proposes a new vehicle model recognition using scale invariant feature transform to car's headlights image. Proposed vehicle model recognition raises the accuracy using "homogeneity" calculated from the distribution of features. In the experiment with 400 test images taken from 54 different vehicles, proposed method has 90% recognition rate and 16.45 homogeneity.

이진 변화탐지 컴포넌트의 개발 및 변화영상의 비교 연구

  • Yu, Byeong-Hyeok;Ji, Gwang-Hun
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.231-236
    • /
    • 2008
  • 본 연구에서는 이진 변화탐지 방법상 요구되는 수동적인 자료처리 단계들을 모듈화하고 통합한 '이진 변화탐지 컴포넌트'를 개발하였으며, 대전 지역의 IKONOS 다중시계열 위성영상의 2개 연구지역에 적용함으로써 그 성능을 검증하였다. 개발된 컴포넌트는 ESRI의 ArcGIS 9.x 상에서 설치 및 실행되며, Visual Basic과 GIS 객체 라이브러리의 결합을 통해 구현되었다. 적용된 모델은 Im. J.(2007)의 연구에서 제시된 '캘리브레이션 기법을 이용한 자동 이진 변화탐지 모델'을 확장 적용한 것으로, 변화영상 히스토그램의 비정규분포를 고려한 누적 생산자 및 사용자 정확도 평가 기법이 최적 임계치 결정에 사용되었다. 다양한 변화탐지 기술들, ID, IR, NCIs, CVA, PCA와 ID, IR의 결합이 실험을 통해 비교 분석되었다. 실험 결과, 개선된 캘리브레이션 기법 적용을 통해 기존 기법보다 향상된 분류정확도를 얻었으며, PC1의 ID가 연구지역의 변화탐지 상에서 가장 우수한 분류 능을 보여주었다.

  • PDF

Study on the improvement of precision and application of STIV using deep learning (딥러닝을 통한 STIV(영상유속계)의 정밀도 및 적용성 향상에 관한 연구)

  • Jeong, Jae Hoon;Kim, Yeon Joong;Hasegawa, Makoto;Yoon, Joug Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.78-78
    • /
    • 2021
  • 영상유속분석법은 비접촉식으로 유속을 측정하는 방법으로 특히 홍수시 하천의 표면유속을 안전하게 계측할 수 있어서 경제적이고 안전한 하천유속 측정 방법 중 하나이다. STIV는 영상의 휘도 정보를 시간 방향으로 나열하여 작성된 STI(Space-Time Image)에 나타나는 패턴의 기울기를 이용하여 유속을 산정하는 방법이다. 특히 STIV(Space-Time Image Velocimetry)는 기존 입자군의 상호상관법에 기초한 입자영상유속계와 달리 표식자의 유무와 상관없이 유속을 측정할 수 있어 적용성과 안정성이 확보된다. 하지만 영상의 상태가 불량한 경우 정확한 유속 측정이 난해하며 야간에는 별도의 조명 추가 및 태풍과 같은 악기상에서는 빗방울이 카메라에 맺히거나 수면의 진동, 구조물의 진동에 의한 영상의 상태가 불량하게 되어 측정 정도가 떨어진다. 이처럼 영상을 이용한 유속 계측에 있어 다양한 연구 및 기술개발이 요구되는 시점이다. 따라서 본 연구에서는 영상을 이용한 정확한 유속측정을 위해 STIV와 인공지능을 융합하여 정확한 유속 평가를 목적으로 한다. 우선 기존 STI에 의한 기울기 추정방법을 확장하여 딥러닝(CNN)에 의한 기울기 추정방법을 도입하였다. CNN은 일반적으로 이미지의 특성을 추출하는데 유용한 방법으로서 STI의 2차원 Fourier변환 이미지를 사용하여 패턴의 기울기를 감지하도록 학습하였고 적용 결과 기울기에 대한 인식율은 매우 양호하였으며 이를 이용한 실제 관측 영상에 적용한 결과 유속에 대한 정밀도도 매우 양호하게 나타났다. 또한 딥러닝을 적용한 STIV는 노이즈(진동, 화면 불량 등)가 있는 영상에서도 안정적으로 유속을 산정할 수 있으며 전파유속계를 이용한 실제 하천의 표면유속 관측치와 비교 검토 결과 매우 양호하게 유속을 평가하고 있는 것으로 나타났다.

  • PDF

Prostate Imaging Reporting and Data System (PI-RADS) v 2.1: Overview and Critical Points (전립선영상 판독과 자료체계 2.1 버전: 개요와 비판적인 의견)

  • Chan Kyo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.75-91
    • /
    • 2023
  • The technical parameters and imaging interpretation criteria of the Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) using multiparametric MRI (mpMRI) are updated in PI-RADS v2.1. These changes have been an expected improvement for prostate cancer evaluation, although some issues remain unsolved, and new issues have been raised. In this review, a brief overview of PI-RADS v2.1 is and several critical points are discussed as follows: the need for more detailed protocols of mpMRI, lack of validation of the revised transition zone interpretation criteria, the need for clarification for the revised diffusion-weighted imaging and dynamic contrast-enhanced imaging criteria, anterior fibromuscular stroma and central zone assessment, assessment of background signal and tumor aggressiveness, changes in the structured report, the need for the parameters for imaging quality and performance control, and indications for expansion of the system to include other indications.

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

Surface Reconstruction Using CORONA KH-4 Imagery (CORONA KH-4 영상을 이용한 3차원 지형정보 취득)

  • Sohn, Hong-Gyoo;Yeu, Bock-Mo;Kim, Gi-Hong;Choi, Jong-Hyun
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2002.03a
    • /
    • pp.145-149
    • /
    • 2002
  • CORONA는 미국이 1960년에서 1972년까지 냉전시대 관심지역에 대한 첩보영상을 취득하기 위하여 운영한 영상취득시스템으로 1995년 일반에 자료가 공개됨에 따라 과거의 고해상도 영상자료를 이용할 수 있는 길이 열리게 되었다. 그러나 현재까지 CORONA 영상처리를 위한 모듈을 제공하는 원격탐측 소프트웨어가 개발되어 있지 않기 때문에 CORONA 영상을 이용하여 수치표고모형이나 정사영상을 제작하기 위해서는 적절한 모델링 방법이 필요하다. CORONA 영상은 파노라마 영상으로 필름 가장자리로 갈수록 왜곡이 많이 생기며 사진기 지표가 없고 위성의 궤도와 위치, 자세, 속도, IMC(Image Motion Compensation)에 대한 자세한 자료를 제공하지 않는 문제점이 있다. 따라서 본 논문에서는 지형복원을 위하여 지상기준점을 이용하는 2가지 모델링 방법을 이용하였다. 첫 번째는 파노라마 왜곡과 촬영 비행체 이동에 의한 왜곡, IMC에 의한 왜곡을 보정하는 모형식을 구성하여 이용하였으며, 두 번째는 위성과 센서에 대한 정보를 필요로 하지 않는 다항식비례모형(RFM; Rational Function Model)을 이용하였다. 대상지역은 서울지역의 입체영상으로 대략 $33km{\times}26km$ 지역이다. 영상은 지상해상도 약 2.7m로 스캐닝하였고 1:1000 수치지도를 통해 20개의 기준점과 36개의 검사점을 관측하였다. 검사점의 위치정확도를 평가해 본 결과 첫 번째 방법은 수평방향으로 평균 3.9m(X), 2.8m(Y)의 오차를 보였으며 표고의 경우 4.2m의 오차를 보여주었다. 두 번째 방법은 수평방향으로 평균 3.2m(X), 2.8m(Y)의 오차를 보였으며 표고의 경우 5.5m의 오차를 보여주었다. 지형복원 정확도를 검증하기 위하여 첫 번째 방법을 이용하여 대상지역 중 일부인 서울 남산지역에 대해 정사영상과 10m간격의 DEM을 제작하였으며 1:1000 수치지도를 통해 제작된 DEM과 비교한 결과 총 43990개 격자점의 표고 차이는 평균 5.98m였다.

  • PDF

Assessing the Positioning Accuracy of High density Point Clouds produced from Rotary Wing Quadrocopter Unmanned Aerial System based Imagery (회전익 UAS 영상기반 고밀도 측점자료의 위치 정확도 평가)

  • Lee, Yong Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.39-48
    • /
    • 2015
  • Lately, Unmanned Aerial Vehicles(UAV), Unmanned Aerial Systems(UAS) or also often known as drones, as a data acquisition platform and as a measurement instrument are becoming attractive for many photogrammetric surveying applications, especially generation of the high density point clouds(HDPC). This paper presents the performance evaluation of a low-cost rotary wing quadrocopter UAS for generation of the HDPC in a test bed environment. Its performance was assessed by comparing the coordinates of UAS based HDPC to the results of Network RTK GNSS surveying with 62 ground check points. The results indicate that the position RMSE of the check points are ${\sigma}_H={\pm}0.102m$ in Horizonatal plane, and ${\sigma}_V={\pm}0.209m$ in vertical, and the maxium deviation of Elevation was 0.570m within block area of ortho-photo mosaic. Therefore the required level of accuracy at NGII for production of ortho-images mosaic at a scale of 1:1000 was reached, UAS based imagery was found to make use of it to update scale 1:1000 map. And also, since this results are less than or equal to the required level in working rule agreement for airborne laser scanning surveying of NGII for Digital Elevation Model generation of grids $1m{\times}1m$ and 1:1000 scale, could be applied with production of topographic map and ortho-image mosaic at a scale of 1:1000~1:2500 over small-scale areas.

Shadow Extraction of Urban Area using Building Edge Buffer in Quickbird Image (건물 에지 버퍼를 이용한 Quickbird 영상의 도심지 그림자 추출)

  • Yeom, Jun-Ho;Chang, An-Jin;Kim, Yong-Il
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.2
    • /
    • pp.163-171
    • /
    • 2012
  • High resolution satellite images have been used for building and road system analysis, landscape analysis, and ecological assessment for several years. However, in high resolution satellite images, shadows are necessarily cast by manmade objects such as buildings and over-pass bridges. This paper develops the shadow extraction procedures in urban area including various land-use classes, and the extracted shadow areas are evaluated by a manually digitized shadow map. For the shadow extraction, the Canny edge operator and the dilation filter are applied to make building edge buffer area. Also, the object-based segmentation was performed using Gram-Schmitt fusion image, and spectral and spatial parameters are calculated from the segmentation results. Finally, we proposed appropriate parameters and extraction rules for the shadow extraction. The accuracy of the shadow extraction results from the various assessment indices is 80% to 90%.

Estimation of Concrete Porosity Using Image Segmentation Method (영상 분할기법을 활용한 콘크리트의 공극률 평가 )

  • Hyun-Joon Jeong;Hoseong Jeong;Jae Hyun Kim;Kang-Su Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.30-36
    • /
    • 2023
  • In this study, an image segmentation model that can evaluate surface porosity based on concrete surface images was derived. Three types of concrete specimens with different water-cement ratios (w/c = 54, 35, and 30%) were prepared, and 2,729 surface images were obtained using an optical microscope. Benchmarking tests, parameter optimization, and final model derivation were performed using the surface images, and an image segmentation model with 97% verification accuracy was obtained. The model was verified by comparing the porosity obtained from the model and X-Ray Microscope (XRM). The model provided similar porosity to that of XRM for the specimens with a high water-cement ratio, but tended to give lower porosity for specimens with a low water-cement ratio.