• Title/Summary/Keyword: 영상유도

Search Result 901, Processing Time 0.026 seconds

Applications of Regularized Dequantizers for Compressed Images (압축된 영상에서 정규화 된 역양자화기의 응용)

  • Lee, Gun-Ho;Sung, Ju-Seung;Song, Moon-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.39 no.5
    • /
    • pp.11-20
    • /
    • 2002
  • Based on regularization principles, we propose a new dequantization scheme on DCT-based transform coding for reducing of blocking artifacts and minimizing the quantization error. The conventional image dequantization is simply to multiply the received quantized DCT coefficients by the quantization matrix. Therefore, for each DCT coefficients, we premise that the quantization noise is as large as half quantizer step size (in DCT domain). Our approach is based on basic constraint that quantization error is bounded to ${\pm}$(quantizer spacing/2) and at least there are not high frequency components corresponding to discontinuities across block boundaries of the images. Through regularization, our proposed dequantization scheme, sharply reduces blocking artifacts in decoded images. Our proposed algorithm guarantees that the dequantization process will map the quantized DCT coefficients will be evaluated against the standard JPEG, MPEG-1 and H.263 (with Annex J deblocking filter) decoding process. The experimental results will show visual improvements as well as numerical improvements in terms of the peak-signal-to-noise ratio (PSNR) and the blockiness measure (BM) to be defined.

Model-based Gradient Compensation in Spiral Imaging (나선주사영상에서 모델 기반 경사자계 보상)

  • Cho, S.H.;Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.15-21
    • /
    • 2009
  • Purpose : A method to estimate a real k-space trajectory based on a circuit model of the gradient system is proposed for spiral imaging. The estimated k-space trajectory instead of the ideal trajectory is used in the reconstruction to improve the image quality in the spiral imaging. Materials and Methods : Since the gradient system has self resistance, capacitance, and inductance, as well as the mutual inductance between the magnet and the gradient coils, the generated gradient fields have delays and transient responses compared to the input waveform to the gradient system. The real gradient fields and their trajectory in k-space play an important role in the reconstruction. In this paper, the gradient system is modeled with R-L-C circuits, and real gradient fields are estimated from the input to the model. An experimental method to determine the model parameters (R, L, C values) is also suggested from the quality of the reconstructed image. Results : The gradient fields are estimated from the circuit model of the gradient system at 1.5 Tesla MRI system. The spiral trajectory obtained by the integration of the estimated gradient fields is used for the reconstruction. From experiments, the reconstructed images using the estimated trajectory show improved uniformity, reduced overshoots near the edges, and enhanced resolutions compared to those using the ideal trajectory without model. Conclusion : The gradient system was successfully modeled by the R-L-C circuits. Much improved reconstruction was achieved in the spiral imaging using the trajectory estimated by the proposed model.

  • PDF

Effects of Videos about Good and Evil on Moral Judgments Regarding Self and Others (인간의 선악을 보여주는 영상은 자신과 타인에 대한 도덕적 판단에 어떤 영향을 미치는가?)

  • Kim, ShinWoo;Lee, WonSeob;Li, Hyung-Chul O.
    • Science of Emotion and Sensibility
    • /
    • v.22 no.2
    • /
    • pp.29-36
    • /
    • 2019
  • Previous resarch demonstrated that moral judgment is not an outcome of rational reasoning, but an independent variable determined by diverse factors. The effects of disgust on moral harshness, audience effect on moralistic punishment are some examples that support this view. The variability of moral judgment raises a question on what effects video stimuli might have on moral judgments. Although a few studies (Schnall, Roper, & Fessler, 2010) have shown that watching a prosocial video clip promote moral behavior, no research have simultaneously tested the effects of both positive and negative video clips on moral (not bahavior but) judgments. Hence, this research tested the effects of viewing videos about good and evil on moral judgments regarding the self and others. To this end, participants were asked to view a video clip depicting content of either positive or negative human behavior and required to make moral judgments on conduct described in a scenario assuming that the person committing the act was either themselves or another person. The results showed significant effects of both video contents (positive, negative) and the actor (self, others) on moral judgments, but they were qualified by the interaction between the two. In particular, participants who watched evil deed of others made harsher judgments on others' moral transgression. Theses results demonstrate that video contents influence moral judgments, and the effect depends on the actor of the immoral behavior. In general discussion, we interpreted the results based on moral disgust, framing effect, and fundamental attribution error.

Imaging dose evaluations on Image Guided Radiation Therapy (영상유도방사선치료시 확인 영상의 흡수선량평가)

  • Hwang, Sun Boong;Kim, Ki Hwan;kim, il Hwan;Kim, Woong;Im, Hyeong Seo;Han, Su Chul;Kang, Jin Mook;Kim, Jinho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • Purpose : Evaluating absorbed dose related to 2D and 3D imaging confirmation devices Materials and Methods : According to the radiographic projection conditions, absorbed doses are measured that 3 glass dosimeters attached to the centers of 0', 90', 180' and 270' in the head, thorax and abdomen each with Rando phantom are used in field size $26.6{\times}20$, $15{\times}15$. In the same way, absorbed doses are measured for width 16cm and 10cm of CBCT each. OBI(version 1.5) system and calibrated glass dosimeters are used for the measurement. Results : AP projection for 2D imaging check, In $0^{\circ}$ degree absorbed doses measured in the head were $1.44{\pm}0.26mGy$ with the field size $26.6{\times}20$, $1.17{\pm}0.02mGy$ with the field size $15{\times}15$. With the same method, absorbed doses in the thorax were $3.08{\pm}0.86mGy$ to $0.57{\pm}0.02mGy$ by reducing field size. In the abdomen, absorbed dose were reduced $8.19{\pm}0.54mGy$ to $4.19{\pm}0.09mGy$. Finally according to the field size, absorbed doses has decreased by average 5~12%. With Lateral projection, absorbed doses showed average 5~8% decrease. CBCT for 3D imaging check, CBDI in the head were $4.39{\pm}0.11mGy$ to $3.99{\pm}0.13mGy$ by reducing the width 16cm to 10cm. In the same way in thorax the absorbed dose were reduced $34.88{\pm}0.93(10.48{\pm}0.09)mGy$ to $31.01{\pm}0.3(9.30{\pm}0.09)mGy$ and $35.99{\pm}1.86mGy$ to $32.27{\pm}1.35mGy$ in the abdomen. With variation of width 16cm and 10cm, they showed 8~11% decrease. Conclusion : By means of reducing 2D field size, absorbed dose were decreased average 5~12% in 3D width size 8~11%. So that it is necessary for radiation therapists to recognize systematical management for absorbed dose for Imaging confirmation. and also for frequent CBCT, it is considered whether or not prescribed dose for RT refer to imaging dose.

  • PDF

Verify Image-Guided Shifts for 6DoF Couch using Yonsei Cancer Center QA Set (Yonsei Cancer Center QA Set을 이용한 6DoF Couch의 이동 정확성 검증)

  • Jung, Dongmin;Park, Hyokuk;Yoon, Jongwon;Lee, Sangkyu;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.7-18
    • /
    • 2017
  • Purpose: A QA Set was established to verify the movement accuracy of image-guided 6DoF Couch and to evaluate its usefulness. Materials and Methods: Two sets of linear accelerators equipped with 6DoF Couch and CBCT were used. Using the established QA Set, each CBCT image was obtained over 15 times through the Penta-Guide Phantom installed with off-set shift values along six translational (Translation; TX, TY, TZ) and rotational (Rotation, Pitch; RX, Roll; RY, Yaw; RZ) directions. Using this method, we compared the reference image and the registration image, and we analyzed the error calculated by measuring the positional accuracy of the modified 6DoF Couch. Results: The Air Cavity corresponding to the Pixel of the reference image and the registration image were all contained between 30 and 66, and the revealing high registration accuracy. Error between the modified off-set value of 6DoF Couch and the measured value along translational directions were $0.25{\pm}0.18mm$ in the TX direction, $0.25{\pm}0.25mm$ in the TY direction, and $0.36{\pm}0.2mm$ in the TZ direction. Misalignments along the rotational axis were $0.18{\pm}0.08^{\circ}$ in the RX direction, $0.26{\pm}0.09^{\circ}$ in the RY direction, and $0.11{\pm}0.08^{\circ}$ in the RZ direction, it was corrected precisely for any value. Conclusion: Using the YCC QA Set, we were able to verify the error of 6DoF Couch along both the translational and rotational directions in a very simple method. This system would be useful in performing Daily IGRT QA of 6DoF Couch.

  • PDF

Comparison of the Clinical Outcomes of an Ultrasound-Guided and C-Arm Guided Cervical Nerve Root Block (초음파와 방사선 투시장치를 이용한 경추 신경근 차단술의 임상결과 비교)

  • Ha, Dae Ho;Shim, Dae Moo;Kim, Tae Kyun;Oh, Sung Kyun;Lee, Hyun Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.78-84
    • /
    • 2020
  • Purpose: This paper compares the clinical outcomes of patients who were treated with a cervical nerve block by ultrasound and C-arm and reports the complication. Materials and Methods: A total of 97 patients were treated with an ultrasound-guided nerve root block from May 1, 2015 to February 8, 2018. On the other hand, 94 patients were treated with a C-arm guided nerve root block. The consequences of the cervical pain and the radiating pain before and after the procedures were reviewed using the verbal numeric rating scale (VNRS). In addition, the complications related to the procedures from the daily notes from the chart were inspected. Results: Sixty-six cases out of 97 cases of ultrasound-guided nerve root block were enrolled in the study. The average age of the patients was 57 years, including 41 males and 25 females. Seventy seven out of 94 cases by a C-arm guided root block were included in the study. The average age of the patients was 55 years, including 40 males and 37 females. Before the nerve root block, the mean numeric rating pain scale (NRS) of the cervical pain in ultrasound-guided block decreased from 5.4 points to 2.7 points at three weeks and 1.4 points at six weeks (p=0.0023, p<0.001), and 3.1 points in the C-arm (p<0.001, p<0.001) at three weeks and 1.5 points at six weeks (p<0.001, p<0.001). In the case of radiating pain, the mean NRS in the ultrasound-guided nerve root block group improved from 6.3 points after the procedure to 2.8 points at three weeks and 1.5 points at six weeks (p<0.001, p<0.001). In the C-arm guided nerve root block group, the NRS improved from 7.4 points after the procedure to 3.3 points at three weeks and 1.9 points at six weeks. In the case of complications, Horner's syndrome and propriospinal myoclonus were observed in one case of C-arm guided block group. Conclusion: The clinical results of the patients who underwent ultrasound-guided cervical nerve root block were not significantly different from those who underwent a C-arm guided cervical nerve root block.

Domain Searching method using DCT-coefficient for Fractal Image Compression (Fractal 압축방법을 위한 DCT 계수를 사용한 도메인 탐색 방법)

  • Suh, Ki-Bum;Chong, Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.2
    • /
    • pp.28-38
    • /
    • 2000
  • This paper proposes a fractal compression method using the domain classification and local searching, which utilize DCT coefficient characteristic Generally, the fractal Image encoding method has a time consuming process to search a domain to be matched with range block In order to reduce computation complexity, the domain and range regions are respectively classified into 4 category by using the characteristics of DCT coefficients and each range region is encoded by a method suitable for the property of its category Since the bit amount of the compressed image depends on the number of range blocks, the matching of domain block and range block is induced on the large range block by using local search, so that compression ratio is increased by reducing the number of range block In the local search, the searching complexity is reduced by determining the direction and distance of searching using the characteristics of DCT coefficients The experimental results shows that the proposed algorithm have 1 dB higher PSNR and 0 806 higher compression ratio than previous algorithm.

  • PDF

Estimating Carbon Sequestration in Forest using KOMPSAT-2 Imagery (KOMPSAT-2 영상을 이용한 산림의 이산화탄소 흡수량 추정)

  • Kim, So-ra;Lee, Woo-kyun;Kwak, Han-bin;Choi, Sung-ho
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.324-330
    • /
    • 2009
  • The objective of this study is to estimate the carbon sequestration in forest stands using KOMPSAT-2 imagery. For estimating the amount of carbon sequestration, the stand biomass of forest was estimated with the total weight, which was the sum of individual tree weight. Individual tree volumes could be estimated by the crown width extracted from KOMPSAT-2 imagery. In particular, the carbon conversion index and the ratio of the $CO_2$ molecular weight to the C atomic weight, reported in the Intergovernmental Panel on Climate Change (IPCC) guideline, was used to convert the stand biomass into the amount of carbon sequestration. Thereafter, the KOMPSAT-2 imagery was classified with the segment based classification (SBC) method in order to quantify carbon sequestration by tree species. This approach, estimating the amount of carbon sequestration for certain species in stand, can be available to extend plot-based carbon sequestration to stand-based carbon sequestration.

Decreasing Parameter Decision in Edge Strength Hough Transform (경계선 강도 허프 변환에서 감쇄 파라미터의 결정)

  • Woo, Young-Woon;Heo, Gyeong-Yong;Kim, Kwang-Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.728-731
    • /
    • 2007
  • Though the Hough transform is a well-known method for detecting analytical shape represented by a number of free parameters, the basic property of the Hough transform, the one-to-many mapping from an image space to a Hough space, causes the innate problem, the sensitivity to noise. To remedy this problem, Edge Strength Hough Transform (ESHT) was proposed and proved to reduce the noise sensitivity. However the performance of ESHT depends on the size of a Hough space and image and some other parameters, which play an important role in ESHT and should be decided experimentally. In this paper, we derived a formula to decide decreasing parameter. Using the derived formulae, the decreasing parameter value can be decided only with the pre-determined values, the size of a Hough space and an image, which make it possible to decide them automatically.

  • PDF

Quadratic Kalman Filter Object Tracking with Moving Pictures (영상 기반의 이차 칼만 필터를 이용한 객체 추적)

  • Park, Sun-Bae;Yoo, Do-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • In this paper, we propose a novel quadratic Kalman filter based object tracking algorithm using moving pictures. Quadratic Kalman filter, which is introduced recently, has not yet been applied to the problem of 3-dimensional (3-D) object tracking. Since the mapping of a position in 2-D moving pictures into a 3-D world involves non-linear transformation, appropriate algorithm must be chosen for object tracking. In this situation, the quadratic Kalman filter can achieve better accuracy than extended Kalman filter. Under the same conditions, we compare extended Kalman filter, unscented Kalman filter and sequential importance resampling particle filter together with the proposed scheme. In conculsion, the proposed scheme decreases the divergence rate by half compared with the scheme based on extended Kalman filter and improves the accuracy by about 1% in comparison with the one based on unscented Kalman filter.