• Title/Summary/Keyword: 영상유도

Search Result 901, Processing Time 0.024 seconds

Image Comparisons using a Diethylenetriaminetriacetic Acid Derivative and Gd-DTPA (Diethylenetriaminetriacetic acid 유도체와 Gd-DTPA와의 영상비교)

  • Cho, Jung-Keun;Lee, Chai-Ho;Han, Tae-Jong;Lim, Cheong-Hwan;Kim, Jung-Nam;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.210-216
    • /
    • 2008
  • In this study, image comparisons were carried out using a MRI contrast medium which was derived by mixing a polyaminocarboxylic ligand and a gadolinium (III) transition metal which is paramagnetic and has good neutron absorbing capabilities with Gd-DTPA which is currently being used widely in the clinical setting. By using a 1.0T (Harmony, SIEMENS) MR equipment, phantoms of which 100cc of saline was diluted with a diethylenetriaminetriacetic acid derivative and Gd-DTPA were imaged. The amount of diethylenetriaminetriacetic acid and Gd-DTPA which was diluted into the 100cc of saline was 0.05mmol/L, 0.1mmol/L, 0.15mmol/L, 0.2mmol/L, 0.3mmol/L, 0.5mmol/L, 1.0mmol/L, 2.0mmol/L, 3.0mmol/L and 4.9mmol/L respectively. Head coils were used and while fixing the SE pulse sequence and image variable (as TE is 14ms, 1NEX with a 256x201 matrix), the signal intensity and simple contrast ratios according to changing concentrations and TR were compared with various TR at 300ms, 400ms, 500ms, 600ms, 700ms, 800ms, 900ms, 1000ms, 1200ms, 1400ms and 1600ms. According to the comparison results of the signal intensity of the image based on changes in contrast medium concentrations and TR, the differences in signal intensity between the two contrast mediums were found to be small at $1.0{\sim}2.0mmol/L$ when the highest signal intensity was achieved. However, at concentrations of 1.0mmol/L or less, the signal intensity was markedly higher in the Diethylenetriaminetriacetic acid derivative than in the Gd-DTPA complex. It was also found that the differences in the signal intensities demonstrated by the concentrations of the contrast mediums were affected by the TR. Accordingly, the efficacy of the Diethylenetriaminetriacetic acid derivative was shown to be better than the Gd-DTPA and also possible to get the optimum image quality by the use of an appropriate TR with appropriate concentrations of contrast medium.

MR Findings of Papillary Neoplasms of the Breast (유두 종양의 자기공명 영상소견)

  • Jo, Yeseul;Kim, Sung Hun;Kang, Bong Joo;Choi, Byung Gil
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • Purpose : To review MR imaging finding of papillary lesion identified as additional suspicious lesion on MR image in women with biopsy-proven breast cancer and to evaluate upgrading rates after subsequent surgical histopathological diagnosis. Materials and Methods: Among 1729 preoperative MR image of women with biopsy proven breast cancer, US-guided CNB-proven 22 papillary lesions from 21 patients, which showed additional suspicious contrast enhancement other than index cancer on MR image, were subjected to the study. Some of these lesions underwent surgery, thus the comparisons between the histopathologic results were able to be compared to the results of US-guided CNB. Also retrospective analysis was done for MR findings of these lesions by BI-RADS MRI lexicon. Results: On MR imaging, 8 mass lesions, 7 non-mass lesions, 7 focus lesions were detected. All of the focus lesion (100%, 7/7) was diagnosed as benign lesion and showed plateau and washout pattern in dynamic MR image. After excisional biopsy, one of 9 benign papilloma (11.1%), 3 of 3 papillary neoplasm with atypia component (100%), 3 of 5 papillary neoplasm (60%) were upgraded to malignancy such as ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC). Conclusion: The MR images of papillary lesions diagnosed by US-guided CNB exhibit no significant differences between malignancy and benign lesion. Also 41.2% of the lesion (7/17) was upgraded after subsequent surgery. Thus all of the papillary lesions require excisional biopsy for definite diagnosis and the MR imaging, it's just not enough by itself.

Study on Application of Ultrasonic Propagation Imager for Non-destructive Evaluation of Composite Lattice Structure (복합재 격자 구조 비파괴평가를 위한 초음파전파 영상화 시스템 활용 연구)

  • Park, Jae-Yoon;Shin, Hye-Jin;Lee, Jung-Ryul
    • Composites Research
    • /
    • v.30 no.6
    • /
    • pp.356-364
    • /
    • 2017
  • Composite lattice structures are tried to be used in various fields because of its benefit in physical properties. With increase of demand of the composite lattice structure, nondestructive testing technology is also required to certificate the quality of the manufactured structures. Recently, research on the development of the composite lattice structure in Republic of Korea was started and accordingly, fast and accurate non-destructive evaluation technology was needed to finalize the manufacturing process. This paper studied non-destructive testing methods for composite lattice structure using laser ultrasonic propagation imaging systems. Pulse-echo ultrasonic propagation imaging system was able to inspect a rib structure wrapped with a skin structure. To reduce the time of inspection, a band divider, which can get signal in different frequency bands at once, was developed. Its performance was proved in an aluminum sandwich panel. In addition, to increase a quality of results, curvature compensating algorithm was developed. On the other hand, guided wave ultrasonic propagation imaging system was applied to inspect delamination in a rib structure. To increase an area of inspection, multi-source ultrasonic wave propagation image was applied, and defects were successfully highlighted with variable time window amplitude mapping algorithm. These imply that ultrasonic propagation imaging systems provides fast and accurate non-destructive testing results for composite lattice structure in a stage of the manufacturing process.

Nondestructive Diagnosis of NPP Piping System Using Ultrasonic Wave Imaging Technique Based on a Pulsed Laser Scanning System (펄스 레이저 스캐닝 기반 초음파 영상화 기술을 활용한 원전 배관 비파괴 진단)

  • Kim, Hyun-Uk;Lee, Chang-Gil;Park, Seung-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.166-173
    • /
    • 2014
  • A noncontact nondestructive testing (NDT) method is proposed to detect the damage of pipeline structures and to identify the location of the damage. To achieve this goal, a scanning laser source actuation technique is utilized to generate a guided wave and scans a specific area to find damage location more precisely. The ND: YAG pulsed laser is used to generate Lamb wave and a piezoelectric sensor is installed to measure the structural responses. The measured responses are analyzed using three dimensional Fourier transformation (3DFT). The damage-sensitive features are extracted by wavenumber filtering based on the 3D FT. Then, flaw imaging techniques of a pipeline structures is conducted using the damage-sensitive features. Finally, the pipes with notches are investigated to verify the effectiveness and the robustness of the proposed NDT approach.

Study on Integrated-Flight Simulation Method Using CFT Imagery (탑재비행시험 영상을 적용한 통합비행 시뮬레이션 기법 연구)

  • Jeong, Dong Gil;Yun, Hyo Seok;Park, Jin Hyen
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.1
    • /
    • pp.111-117
    • /
    • 2018
  • It is indispensable for a missile to track a target under the flight condition since the tracking capability affects the system performance considerably. The best way to verify the tracker's performance is flight test while it costs too much. Consequently, captive flight test or CFT has an important role in the development of a missile system. CFT, however, cannot simulate missile dynamics and is an offline and open-loop test. In this paper, we propose a new integrated-flight simulation(IFS) method using CFT imagery to overcome the limitation of synthetic image-based IFS method. This method increases the utilization of CFT's outputs and compensates the reality of imagery which lacks in the synthetic image-based IFS. Using this method make it possible to verify the system capability in various simulation modes.

KAPE의 발견2 - ③ 광주전남지원 특화사업 "오리산업 길라잡이 프로젝트"

  • 축산물품질평가원
    • KAPE Magazine
    • /
    • s.254
    • /
    • pp.10-12
    • /
    • 2017
  • 광주전남지원은 오리고기에 대한 올바른 정보 제공으로 AI발생에 따른 소비자의 오해를 불식시켜 소비 활성화를 유도하고 이를 통해 오리산업 발전에 기여하기 위하여 "오리산업 길라잡이 프로젝트"를 진행하고 있다. 구체적인 활동으로는 전남 오리산학협력단, 한국오리협회 광주전남지회와 업무협약을 체결하고 상호 협력을 통해 오리 홍보책자 제작, 오리 영상 제작 및 오리고기를 활용한 요리 레시피 개발 등을 추진하고 있다.

  • PDF

Epipolar Resampling for High Resolution Satellite Imagery Based on Parallel Projection (평행투영 기반의 고해상도 위성영상 에피폴라 재배열)

  • Noh, Myoung-Jong;Cho, Woo-Sug;Chang, Hwi-Jeong;Jeong, Ji-Yeon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.4
    • /
    • pp.81-88
    • /
    • 2007
  • The geometry of satellite image captured by linear CCD sensor is different from that of frame camera image. The fact that the exterior orientation parameters for satellite image with linear CCD sensor varies from scan line by scan line, causes the difference of image geometry between frame and linear CCD sensor. Therefore, we need the epipolar geometry for linear CCD image which differs from that of frame camera image. In this paper, we proposed a method of resampling linear CCD satellite image in epipolar geometry under the assumption that image is not formed in perspective projection but in parallel projection, and the sensor model is a 2D affine sensor model based on parallel projection. For the experiment, IKONOS stereo images, which are high resolution linear CCD images, were used and tested. As results, the spatial accuracy of 2D affine sensor model is investigated and the accuracy of epipolar resampled image with RFM was presented.

  • PDF