• Title/Summary/Keyword: 영상비교

Search Result 8,783, Processing Time 0.039 seconds

Dissolved Copper and Nickel in the surface water of East Sea, Korea (동해 표층수중 용존 Cu, Ni의 분포 특성)

  • Yoon, Sang Chol;Yoon, Yi Yong;Suh, Young Sang
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.4
    • /
    • pp.257-267
    • /
    • 2014
  • The distributions of trace metals in the East Sea were investigated during the R/V Lavrentyev cruise (July 2009) in which four transects from Russia shore to South were conducted to collect 25 surface water samples. The total dissolved concentrations of Cu and Ni were measured using ICP-MS, DRC-e. In the coastal area, their concentrations of Russia shore (Cu, 1.51; Ni, 1.82 nM) were 1.9 times for Cu and 2.0 times for Ni lower than Korea shore (Cu, 2.87; Ni, 3.71 nM). In the subregion, their concentrations of Warm region (Cu, 3.03; Ni, 2.28 nM) were higher for Cu than Cold region (Cu, 2.04; Ni, 2.28 nM). The distributions of Cu and Ni concentrations were divided by lowest level at $10^{\circ}C$ of water temperature. In this study period, the surface water temperatures of Russia shore and Japan basin were lower than $10^{\circ}C$ and them of Ulleung basin and Sakhalin shore were higher. Below $10^{\circ}C$, Cu and Ni concentrations increased when surface water temperatures decreased. Above $10^{\circ}C$, their concentrations increased with temperature, which showed highest concentrations in the Ulleung basin, directly influenced by flux from East Korean Warm Current. By comparing with other sea areas (Western Mediterranean, Atlantic), Cu concentrations in the East Sea were a little higher and Ni concentrations were lower. Particularly as the level of Cu in the offshore in the Ulleung basin were higher than in the coastal area, We can suggest that the atmospheric flux of Cu is relatively important in this area.

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

Development of Radiosynthetic Methods of 18F-THK5351 for tau PET Imaging (타우 PET영상을 위한 18F-THK5351의 표지방법 개발)

  • Park, Jun-Young;Son, Jeong-Min;Chun, Joong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.51-54
    • /
    • 2018
  • Purpose $^{18}F-THK5351$ is the newly developed PET probe for tau imaging in alzheimer's disease. The purpose of study was to establish the automated production of $^{18}F-THK5351$ on a commercial module. Materials and Methods Two different approaches were evaluated for the synthesis of $^{18}F-THK5351$. The first approach (method I) included the nucleophilic $^{18}F$-fluorination of the tosylate precursor, subsequently followed by pre-HPLC purification of crude reaction mixture with SPE cartridge. In the second approach (method II), the crude reaction mixture was directly introduced to a semi-preparative HPLC without SPE purification. The radiosynthesis of $^{18}F-THK5351$ was performed on a commercial GE $TRACERlab^{TM}$ $FX-_{FN}$ module. Quality control of $^{18}F-THK5351$ was carried out to meet the criteria guidelined in USP for PET radiopharmaceuticals. Results The overall radiochemical yield of method I was $23.8{\pm}1.9%$ (n=4) as the decay-corrected yield (end of synthesis, EOS) and the total synthesis time was $75{\pm}3min$. The radiochemical yield of method II was $31.9{\pm}6.7%$ (decay-corrected, n=10) and the total preparation time was $70{\pm}2min$. The radiochemical purity was>98%. Conclusion This study shows that method II provides higher radiochemical yield and shorter production time compared to the pre-SPE purification described in method I. The $^{18}F-THK5351$ synthesis by method II will be ideal for routine clinical application, considering short physical half-life of fluorine-18 ($t_{1/2}=110min$).

Measurement Technique for Soil Loss Estimation Using Laser Distance Meter in Sloped Upland (거리측정기를 이용한 경사지 밭의 토양유실량 평가)

  • Park, Chol-Soo;Jung, Yeong-Sang;Joo, Jin-Ho;Lee, Gye-Jun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.3
    • /
    • pp.127-133
    • /
    • 2005
  • The measurement technique using laser distometer to estimate soil erosion on sloped upland was assessed for its possibility for application. This technique was practiced in lysimeter installed in Chuncheon and Pyeongchang in 2001. The lysimeter installed at Chuncheon has 12% slope, 10 m slope length, 2 m width, and soil texture was sandy loam, while the lysimeter installed at Pyeongchang showed 23% slope, 15 m slope length, 5 m width, and sandy loam soil. Change of surface soil height was monitored using laser distance meter before and after rainy season on same spots. The Investigated periods in Chuncheon and Pyeongchang were from 22 June to 22 September and from July to October, respectively. Precipitation in Chuncheon and Pyeongchang in this period was 892.2 and 931.9 mm, respectively. Rainfall over 60% of annual precipitation was concentrated on July and August in Chuncheon and September and October in Pyeongchang, respectively. By monitoring the change of surface soil height using laser distance meter before and after rainy season, eroded soil surface in up-down fallow field in Chuncheon was 0.874 cm, while eroded soil surface in slant furrow field in Pyeongchang was 1.127 cm, which correspond to 79.5 and $98.0MT\;ha^{-1}$. Soil erosion increased as furrow length increased. Amounts of estimated soil loss using laser distance meter was 0.98-1.18 times higher compared to the estimated values through Iysimeter experiment, which implies possibility for application to monitor soil loss particularly in up-down and slant furrowed field. However, in the lysimeter with contoured tillage, amount of estimated soil loss using laser distance meter was approximately a half compared to that from lysimeter experiment, which implies inadequacy of distance meter application in contour- tillage field. The great soil loss difference between distance meter and lysimeter might be caused by disruption of some of the contoured furrows in lysimeter. The measurement technique using distometer in this study could be useful to estimate soil loss especially in up-down and slant-tillage fields.

Evaluation of the Treatment Response after Hypofractionated Radiotherapy in Patients with Advanced Head and Neck Cancers (진행성 두경부 상피세포암 환자에서 소분할 방사선조사 후의 치료반응 평가)

  • Kim, Won-Taek;Ki, Yong-Kan;Nam, Ji-Ho;Kim, Dong-Hyun;Cho, Kyu-Sup;Lee, Jin-Choon;Lee, Byung-Joo;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.55-63
    • /
    • 2009
  • Purpose: This study was performed to objectively evaluate the rate of tumor response to hypofractionated radiotherapy for advanced squamous cell carcinomas of the head and neck. Materials and Methods: Thirty-one patients with advanced squamous cell carcinoma of the head and neck, who were treated by hypofractionated radiotherapy with 3 Gy per fraction for palliative purpose between 1998 and 2008, were reviewed retrospectively. Every tumor-volume was measured and evaluated from CT (computed tomography) images obtained before and 2~3 months after radiotherapy. The radiation toxicity was assessed during and after radiotherapy. A statistical analysis was performed to investigate overall survival, progressionfree survival, and the prognostic factors for survival and response. Results: The median age of the study patients was 70 years. In addition, 85% of the patients were in stage 4 cancer and 66.7% had an ECOG performance status of 1~2. The mean tumor-volume was 128.4 cc. Radiotherapy was administered with a total dose of 24~45 Gy (median: 36 Gy) over 10~25 days. Twenty-nine patients were treated with 30 Gy or more. The observed complete response rate was 12.9% and the partial response rate was 61.3%. Median survival time was 8.9 months and the 1-year progression-free survival rate was 12.9%. The treatment response rate was confirmed as a prognostic factor in the rate of survival. The primary site, stage, tumor-volume, radiotherapy field and overall radiation-dose showed a significant relationship with survival and treatment response. No grade 4 toxicity was observed during and after radiotherapy. Conclusion: There was an objective tumor-regression in about 74% of patients treated by hypofractionated radiotherapy. Further evaluation is needed to select the appropriate fraction-size and patient who may require the additional radiotherapy.

Treatment Planning for Minimizing Carotid Artery Dose in the Radiotherapy of Early Glottic Cancer (조기 성문암의 방사선치료에서 경동맥을 보호하기 위한 치료 계획)

  • Ki, Yang-Kan;Kim, Won-Taek;Nam, Ji- Ho;Kim, Dong-Hyun;Lee, Ju-Hye;Park, Dal;Kim, Don-Won
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.115-120
    • /
    • 2011
  • Purpose: To examine the feasibility of the treatment planning for minimizing carotid artery dose in the radiotherapy of early glottic cancer. Materials and Methods: From 2007 to 2010, computed tomography simulation images of 31 patients treated by radiotherapy for early glottic cancer were analyzed. The virtual planning was used to compare the parallel-opposing fields (POF) with the modified oblique fields (MOF) placed at angles to exclude the ipsilateral carotid arteries. Planning target volume (PTV), irradiated volume, carotid artery, and spinal cord were analyzed at a mean dose, $V_{35}$, $V_{40}$, $V_{50}$ and with a percent dose-volume. Results: The beam angles were arranged 25 degrees anteriorly in 23 patients and 30 degrees anteriorly in 8 dose-volume of carotid artery shows the significant difference (p<0.001). The mean doses of carotid artery were 38.5 Gy for POF and 26.3 Gy for MOF and the difference was statistically significant (p=0.012). Similarly, $V_{35}$, $V_{40}$, and $V_{50}$ also showed significant differences between POF and MOF. Conclusion: The modified oblique field was respected to prevent a carotid artery stenosis and reduce the incidence of a stroke based on these results.

Sinus Node Function after Extended Transseptal Approach for Mitral Valve Surgery: 164 Clinical Cases (경중격 절개방식을 좌심방 상부까지 연장시킨 방법을 통한 승모판막 수술 후 동방 결절 기능부전에 대한 164예 임상분석)

  • Ryu Se Min;Kim Hyun Koo;Cho Yang Hyun;Sim Jae Hoon;Sohn Young-sang;Choi Young Ho;Kim Hark Jei
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.214-220
    • /
    • 2005
  • Extended transseptal approach can provide an excellent view of the mitral valve but the safety of this approach is controversial because this incision requires transaction of the sinus node artery, which in most cases and can result postoperative arrhythmia. The purpose of this study was to evaluate perioperative and longterm conduction disturbances and the cardiac rhythms of patients who underwent an extended transseptal approach for mitral valve surgery. Material and Method: Postoperative cardiac rhythms were analyzed in the 164 consecutive patients who received mitral valve replacements with a extended transseptal approach between March 1992 and July 2003. Result: Of the 84 patients in normal sinus rhythm, 34 ($39\%$) had developed transient junctional rhythm and atrial fibrillation after operation, lasting less than 72 hours in most of cases. No intractable arrhythmias occurred. Most of these arrhythmia were not detected at the time of discharge and only 8 patients ($9\%$) had atrial fibrillation at discharge. Postoperative PR intervals increased for 1 week, then decreased within 2 weeks postoperatively, and returned to normal range by 6 months postoperatively. During the postoperative period, 4 of the 78 patients with preoperative atrial fibrillation developed normal sinus thythm. Conclusion: The post-operative arrhythmias were temporary and showed no significant complications after extended transseptal approach for the mitral valve surgery.

Thallium-201 SPECT in the Evaluation of Postoperative Tumor Recurrence on the Chest Wall in Lung Cancer (폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성)

  • Ryu, Young-Hoon;Kim, Hyung-Jung;Ahn, Chul-Min;Kim, Se-Kyu;Paik, Hyo-Chae;Lee, Doo-Yun;Chung, Kyung-Young;Yune, Min-Jin;Park, Sang-Jung;Moon, Sung-Wook;Kim, Sang-Jin;Lee, Jong-Doo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.542-549
    • /
    • 2002
  • Purpose : The purpose of our study was to assess the usefulness of the Tl-201 SPECT for the detection of the postoperative tumor recurrence on chest wall. Methods: 28 patients including 14 with suspected recurrence of tumor in the chest wall on postoperative chest cr scan, 10 with postoperative pleural effusion which proved benign on radiologic, cytologic and laboratory findings, and 4 with chronic tuberculous empyema as control group were included. All patients underwent SPECT 30 minutes and 4 hours after intravenous injection of 111MBq of Tl-201. Tumor uptake was visually graded by two interpreters and scored as follows : no uptake:0, similar to contralateral lung: 1, higher than contralateral lung but less than heart:2 and similar to heart:3. Results : Markedly increased (grade 3 or 2) Tl-201 uptake was noted in patients with suspected recurrence of tumor in the chest wall (13/14) whereas no (8/10) or minimal (2/10) uptake along the collapsed lung in patients with postoperative benign pleural effusion. In two patients, Tl-201 SPECT revealed additional recurrent tumor mass lesions that were barely perceptible on chest cr scan. Patients with chronic tuberculous empyema showed relatively smoothly marginated increased uptake along the chest wall 4/4), but lesser in degree (grade 1 or 2), when compared to recurrent tumor uptake. Conclusion : Tl-201 lung SPECT seems to be useful to detect postoperative tumor recurrence on chest wall and to differentiate malignant from benign pleural effusion and may provide additional information to the morphologic data obtained by CT.

The difference between the two methods for myocardial performance index in children (소아에서 심근 수행 지수 측정 방법간의 차이)

  • Joung, Jae-Il;Lee, Chang-Hyun;Kim, Jae-Kwang;Park, Kie-Young;Kim, Bong-Sung;Lee, Jung-Ju;Han, Myung-Ki
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1324-1328
    • /
    • 2006
  • Purpose : The object of this study was to determine the difference between two methods for myocardial performance index(MPI) in children, using the conventional and pulsed Doppler echocardiography. Methods : A total of 27 children with anatomically normal hearts were enrolled for the study. all were examined by conventional and pulsed Doppler echocardiography at Gangneung Asan Hospital between December, 2005 and February, 2006. First, we measured the time interval(a1) between the mitral inflows from apical 4-chamber view, and the ejection time(ET1) from apical 5-chamber view. And then, we calculated MPI1, isovolumic contraction time(ICT1) and isovolumic relaxation time (IRT1). Secondly, we measured ICT2, ET2 and IRT2 from apical 5-chamber view with a Dopper signal placed at just below junction between mitral and aortic valve at the same cardiac cycle. And then, we calculated MPI2. We compared MPI1 to MPI2. All MPIs were calculated by using the formula, MPI=(ICT+IRT)/ET. Results : The mean age was $5.7{\pm}2.2years$ old(M:F=15:12). The MPI2 was higher than MPI1: $0.277{\pm}0.083$ vs. $0.428{\pm}0.081$(MPI1 vs MPI2, P=0.000). Also, the ICT2 was higher than ICT1: $56{\pm}15msec$ vs $97{\pm}18msec$(ICT1 vs ICT2, P=0.000) and the IRT2 was higher than IRT1: $42{\pm}8msec$ vs $53{\pm}9msec$(IRT1 vs IRT2, P=0.000). But, the ET2 was lower than ET1: $260{\pm}16msec$ vs $254{\pm}14msec$ (ET1 vs ET2, P=0.01). There was, as well, positive linear correlation between MPI1 and MPI2. Conclusion : This study showed that there is a difference between MPI1 and MPI2 in connection with estimating methods. However, the two MPIs had a positive linear correlation. Judging from our results, the MPI of the new method might be a useful index of venticular global function in children.

A Study on the Labeling Efficiency and Cytotoxicity of Hepatocyte-targeting Galactosylated Chitosan Compounds (간세포 지향성 Galactosylated Chitosan 화합물의 표지 수율 향상 및 세포 독성에 대한 연구)

  • Kim, Dae-Weung;Jeong, Hwan-Jeong;Kim, Eun-Mi;Kim, Se-Lim;Kang, Yun-Hee;Kim, Min-Woo;Kim, Chang-Guhn;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.5
    • /
    • pp.278-283
    • /
    • 2005
  • Purpose: In prior study, we synthesized $^{99m}Tc$-galactosylated chitosan (GC) and performed in vivo biodistribution study, showed specific targeting to hepatocyte. The aim of this study is to evaluate the labeling efficiency and cytotoxicity of modified galactosylated chitosan compounds, galactosyl methylated chitosan (GMC) and HYNIC-galactosylated chitosan (GCH). Materials and Methods: GC, GMC and GCH were synthesized and radiolabeled with $^{99m}Tc$. Then, they were incubated for 6 hours at room temperature and human serum at $37^{\circ}C$. Labeling efficiencies were determined at 15, 30 m, 1, 2, 3 and 6 h after radiolabeling. To evaluate cytotoxicity, MTT assay was performed in HeLa and HepG2 cells. Results: In comparison with them of $^{99m}Tc$-GC labeling efficiencies of $^{99m}Tc$-GMC were significantly improved (100, 97 and 89%) in acetone and 96.3, 95.8 and 75.6% in saline at 15 m, 1 and 6 h, respectively). Moreover, $^{99m}Tc$-GCH showed more improved labeling efficiencies (>95% in acetone and human serum and >90% in saline at 6 h). In MTT assay, cytotoxicity was very low and not different from that of controls. Conclusion: These results represent that these compounds are radiochemically compatible radiopharmaceuticals, can be used in hepatocyte specific imaging study and in vivo gene or drug delivery monitoring.