• Title/Summary/Keyword: 염소-차아염소산

Search Result 18, Processing Time 0.021 seconds

Combined Treatment of Acorn Pomace Extract, Fumaric Acid, and Mild Heat for Inactivation of Microorganisms on Red Chard (도토리박 추출물과 푸마르산 및 중온 열 병합처리에 의한 적근대의 미생물 제어 효과)

  • Park, Shin-Min;Son, Kyung Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.11
    • /
    • pp.1696-1700
    • /
    • 2016
  • In this study, acorn pomace extract (APE) was developed as a natural chemical sanitizer and substitute for chlorine-based sanitizers such as sodium hypochlorite containing harmful substances. Antimicrobial activities of APE and its combined treatments with fumaric acid (FA) and mild heat against Listeria monocytogenes inoculated on red chard were examined. Among the treatments, combined treatment of 0.5% APE at $50^{\circ}C$ and 0.5% FA was the most effective, causing reduction of L. monocytogenes populations by 3.36 log CFU/g compared to the control. After combined treatment, populations of aerobic mesophilic bacteria in the red chard decreased by 2.89 log CFU/g during storage at $4^{\circ}C$ for 8 days compared to the control. Regarding color changes in red chard upon combined treatment, there was no significant change among the red chard samples. These results indicate that combined treatment of APE, FA, and mild heat can improve microbial safety of red chard without affecting quality such as color during storage.

Bactericidal Activity of Strongly Acidic Electrolyzed Water on Various Vegetables and Kitchen Apparatus (채소 및 주방기구에 대한 강산성전해수의 살균효과)

  • Kim, Yun-Jung;Choi, Kyoo-Duck;Shin, Il-Shik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.5
    • /
    • pp.776-781
    • /
    • 2010
  • The properties and bactericidal activities of strongly acidic electrolyzed water (SEW) against food-borne pathogenic bacteria, vegetables and kitchen apparatuses were investigated. The available chlorine concentration, pH and oxidation reduction potential (ORP) of SEW were $35{\pm}1.2\;ppm$, $2.3{\pm}0.2$, and $1,140{\pm}20.4\;mV$, respectively. Five strains of food-borne bacteria with initial cell number of 7.00 log CFU/mL were not detected except Bacillus cereus after treatment with SEW for 60 sec. The numbers of Bacillus cereus were reduced to 2.08{\pm}1.00 log CFU/mL at the same condition. In vegetables, SEW treatment after washing strongly in alkalic electrolyzed water (AEW) showed better bactericidal effects than SEW only. The viable cell on stainless steel bowl ($3.86{\pm}2.49\;\log\;CFU/100\;cm^2$) and cup for water ($2.40{\pm}1.80\;\log\;CFU/100\;cm^2$) were not detected by SEW treatment (35 ppm of available chlorine concentration) for 30 sec, but survival of more than 1.00 log CFU/$100\;cm^2$ of viable cell was shown by washing of sodium hypochlorite solution at the same condition. On the other hand, the coliform group bacteria ($5.08{\pm}4.00\;CFU/100\;cm^2$) were detected on rubber globe only, and more than 2.00 log CFU/$100\;cm^2$ of viable cell and coliform group bacteria on it survived, though it was washed with flowing SEW for 30 sec.

Efficacy of Electrolyzed Water and Aqueous Chlorine Dioxide for Reducing Pathogenic Microorganism on Chinese Cabbage (전기분해수 및 이산화염소수 처리에 따른 배추의 미생물 제어 효과)

  • Park, Seong-Soon;Sung, Jung-Min;Jeong, Jin-Woong;Park, Kee-Jai;Lim, Jeong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.240-246
    • /
    • 2012
  • This study evaluated the efficacy of strong acidic electrolyzed water (SAcEW), low alkaline electrolyzed water (LAlEW) and aqueous chlorine dioxide (ACD) for reducing pathogenic bacteria($Escherichia$ $coli$, $Bacillus$ $cereus$, $Salmonella$ Typhimurium, $Stapylococcus$ $aureus$) on Chinese cabbage. Artificially inoculated Chinese cabbage was immersed for 1, 5 and 10 min with TW, NaClO, EW and ACD. Generally, leaves showed more effective reduction than stems. Regarding the inhibitory effect, ACD treatment showed the highest effects rather than other treatments. When Chinese cabbage was immersed for 3 min in sterilized water, it was reduced to a minimum of 1.33 log CFU/g at LAlEW and a maximum of 4.70 log CFU/g at ACD. Compared to NaClO, ACD and LAlEW which showed a reduction of 3.2 log CFU/g ($Sal.$ Typhimurium) and 2.7 log CFU/g($B.$ $cereus$), respectively. Furthermore, the others had similar inhibitory effects compared to NaClO.

Changes in Quality of Soybean Sprouts Washed with Electrolyzed Water during Storage (전기분해수 처리에 따른 콩나물의 저장 중 품질변화)

  • Yoo, Jae-Yeol;Jang, Keum-Il
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.4
    • /
    • pp.586-592
    • /
    • 2011
  • The storage quality of soybean sprouts washed with various electrolyzed waters was investigated. The washing solutions consisted of tap water (TW), sodium hypochlorite electrolyzed water (SHEW), and slightly acidic electrolyzed water (SAEW). The number of bacteria on the soybean sprouts after 5 min of exposure to TW, SHEW, and SAEW resulted in >0.5, 2.0, and 2.0 log CFU/g reductions, respectively. At both $4^{\circ}C$ and $25^{\circ}C$, the number of bacteria, weight loss ratio, and b value rapidly increased, and pH and L value rapidly decreased in soybean sprouts washed with TW. Whereas, the number of bacteria, pH, weight loss ratio, and color slowly changed in the soybean sprouts washed with SHEW and SAEW. Consequently, these results indicate that washing with electrolyzed water is an effective means of maintaining the quality and enhancing the shelf-life of soybean sprouts; both SHEW and SAEW reduced bacterial growth without affecting the other properties of soybean sprouts during storage.

Applicable Properties of Electrolyzed Acid-Water as Cleaning Water (세정수로서의 전해산화수 적용 특성)

  • 정진웅;정승원;김명호
    • Food Science and Preservation
    • /
    • v.7 no.4
    • /
    • pp.395-402
    • /
    • 2000
  • To enlarge application field of electrolyzed acid-water(EAW) on food industry, the changes of EAW properties by storage conditions and heating were investigatet. It was showed that storing EAW in closed container is mon effective to keep up the oxidation-reduction potentials(ORP), hyperchloride content and pH than stored in opened ones. ORP of EAW stored in closed container could be kept mon than 1 month as 1,150 mV levels. Ruing heating from 2$0^{\circ}C$ to 95$^{\circ}C$, ORP was increased to 1,150 mV levels at 95$^{\circ}C$ after gradual decrease to 5$0^{\circ}C$. Tyrosinase activity was decreased approximately to 26%~35% in EAW having a 950 mV~1,140 mV ORP. Also it was confirmed that EAW has anti-browning effect as sliced apple and potato, and their juices treated with EAW had conspicous difference in their $\Delta$E value. 12 kinds of pesticides such as aldrine, capful diazinon, diedrin, $\alpha$-endosulfan $\beta$-endosulfan, endosulfan sulfate, endrin, $\alpha$-BHC, o,p'-DDT, procymidone, PCNB added in EAW were recovered from ND~73.6% comparing to ones added in distilled water. The recovered amounts of pesticides, procymidone and diazinon in lettuce after soaking in EAW were 1.12 ppm and ND, compared with those of amounts soaked in distilled water were 3.67 ppm and 3.05 ppm respectively. So, it seems that EAW has potentials to promote the degradation of pesticides.

  • PDF

WATER CHLOROFORM LEVELS IN INDOOR SWIMMING POOLS IN A CITY OF KOREA AND IN A CITY OF NEW JERSEY IN THE UNITED STATES (국내 및 미국 뉴저지주의 수영장 물에서의 클로로포름)

  • 조완근
    • Journal of Environmental Science International
    • /
    • v.3 no.2
    • /
    • pp.101-109
    • /
    • 1994
  • Chlorinated water in swimming pools contains chloroform at elevated levels compared to chlorinated drinking water Chloroform levels in four indoor swimming pools(swimming pools A, B and C in a city of Korea and swimming pool D in a city of New Jersey in the United States) were examined. The chloroform levels in the water of swimming pool C (city-managed) weve shown to be significantly(p=0.0001) different from those of private swimming pools A and B: the mean chloroform levels in the pools A, B, and C are 22.8, 17.8, and 31.1 $\mu\textrm{g}$/l, respectively. Furthermore, all of these chloroform levels are significantly(P=0.0001) different from those of New Jersey: chloroform concentration of the Korean pools ranged from 10.9 $\mu\textrm{g}$.l to 47.9 $\mu\textrm{g}$/l with a mean of 23.2 $\mu\textrm{g}$/l, while it ranged from 27 $\mu\textrm{g}$/l to 96$\mu\textrm{g}$/l with a mean of 64.4 $\mu\textrm{g}$/l in the New Jersey pool. The disinfection processes would cause part of this difference since the swimming pools in Korea applied both chlorination and ozonation method, while the swimming pool in New Jersey used chlorination method only. It was implied that swimming parameters inconsistently vary, resulting in fluctuation of and no constant accumulation of chloroform in the water with the change of time for the day. A regression analysis showed no relationships between sampling time and chloroform concentrations for the sampling day in the swimming pools of Korea. A F-test indicated no significant difference of chloroform concentrations in the morning and afternoon samples collected in the swimming pools. Ingestion dose was estimated to be 0.58$\mu\textrm{g}$ from an hour swimming in a city of Korea, taking into accounting an average of 23.2 $\mu\textrm{g}$/l in swimming pools in the city In extreme situation, the ingestion dose was estimated to be 12.0 $\mu\textrm{g}$ from an hour swimming in a city of Korea.

  • PDF

Effect on Corrosion Characteristics of SS 400 Steel by Alkali Water pH from Electrolysis of City Water (수돗물의 전기분해에 의해서 생성된 알카리수의 pH가 SS 400강의 부식특성에 미치는 영향)

  • Moon, Kyung-Man;Ryoo, Hae-Jeon;Kim, Yun-Hae;Jeong, Jae-Hyun;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.248-255
    • /
    • 2017
  • Many rivers and seas have been affected by environmental contamination. Therefore, city water supplies often require a high-degree purification treatment to provide safe drinking water. However, in order to achieve a high-degree purification treatment, a large amount of chlorine has to be added to sterilize city drinking water. The added chlorine reacts chemically with water and forms hypochlorous and chlorine ions. The hypochlorous ionizes with hypochlorous ions and hydrogen ions. As a result, the city water contains a large amount of chlorine ion. As such, when city water is used with domestic boilers, many kinds of heat exchangers, and the engines of vehicle and ships, there are often corrosion problems. In this study, alkali water was electrochemically made by electrolysis of city water, and corrosion properties between alkali and city water were investigated with an electrochemical method. Most of the chlorine ions are thought to not be contained in the alkali water because the alkali water is created in the cathodic chamber with an electrolysis process. In other words, the chlorine ion can be mostly removed by its migration from a cathodic chamber to an anodic chamber. Moreover, the alkali water also contains a large amount of hydroxide ion. The alkali water indicated relatively good corrosion resistance compared to the city water and the city water exhibited a local corrosion pattern due to the chlorine ion created by a high-degree purification treatment. In contrast, the alkali water showed a general corrosion pattern. Consequently, alkali water can be used with cooling water to inhibit local corrosion by chlorine ions in domestic boilers, various heat exchangers and the engine of ships and for structural steel in a marine structure.

Comparison of Characteristics on Electrolyzed Water Manufactured by Various Electrolytic Factors (전해인자에 따른 전기분해수의 특성 비교)

  • Kim, Myung-Ho;Jeong, Jin-Woong;Cho, Young-Je
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.416-422
    • /
    • 2004
  • Efficacy of surface sterilization and physicochemical properties of electrolyzed water manufactured depending on electrolyte, materials, and type of electrolytic diaphragm used were investigated. Physical properties of electrolyzed water manufactured from diaphragm system showed the highest effectiveness under at distance between diaphragms of 1.0 mm and 20% NaCl supplying rate of 6 mL/min. ORP, HClO (should defined) content, and pH at above conditions were 1,170 mV, 100 ppm, and 2.5, respectively. Two-stage electrolyzed system was more effective than one-stage one. Electrolyzed water manufactured from non-diaphragm system at 4 mL/min supplying rate of 20% NaCl was similar to the most effective diaphragm system, whereas ORP, HClO content, and pH were 800 mV, 200 ppm, and 9, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORPs of 750 and 1,150 mV in non-diaphragm and diaphragm systems, respectively, and at HClO content of 100 ppm. Physicochemical properties of electrolyzed water manufactured from electrolytic diaphragm of $IrO_{2}$ and Pt+Ir were more effective than that of Pt. ORP and HClO contents of electrolyzed water manufactured from various electrolytes were high in order of NaCl>KCl>$CaCl_{2}$, whereas no differences were observed among electrolytes in sterilization efficacy. Twelve kinds of microorganisms tested (initial total count, $10^{5}-10^{6}CFU/mL$) were sterilized within 1-2 min by electrolyzed water.