• Title/Summary/Keyword: 열 전달 해석

Search Result 461, Processing Time 0.028 seconds

A Study on the natural Convection and Radiation in a Rectangular Enclosure with Ceiling Vent (천장개구부를 갖는 정사각형 밀폐공간내의 자연대류-복사 열전달에 관한 연구)

  • Park Chan-kuk;Chu Byeong-gil;Kim chol;Jung Jai-hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.28-39
    • /
    • 1998
  • This study investigated the natural convection and radiation in a rectangular enclosure with ceiling vent experimentally and numerically. A heat source is located on the center of the bottom surface. The analysis was peformed a pure convection and is combination of natural convection and radiation. The shape of the considered two dimensional model is a square whose center of ceiling($30\%$) is opened. The numerical simulations are carried out for the pure natural convection case and the combined heat transfer case by using the SIMPLE algorithm. For the turbulent flow, Reynolds stresses are closed by the standard $k-{\epsilon}$ model and the wall function is used to determine the wall boundary conditions. The experiment was performed on the same geometrical shape as the computations. The radiative heat transfer is analized by the S-N discrete ordinates method. The results of pure natural convection are compared with those of combined heat transfer by the velocity vectors, stream lines, isothermal lines. The results obtained are as follows 1. Comparing the results of pure convection with those of the combined convection-radiation through the shape of stream lines, isothermal lines are similar to each other. 2. The temperature fields obtained by numerical method are compared to those obtained by experimental one, and it is found that they are showed mean relative error $8.5\%$. 3. Visualization bt smoke is similar to computational results.

  • PDF

A Unified Theoretical Treatment for Thermal Analysis of Cooling Towers, Evaporating Condensers, and Fluid Coolers (냉각탑, 증발식 응축기 및 밀폐식 냉각탑의 전열해석을 위한 통일이론)

  • Ryu, Hae-Seong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.1
    • /
    • pp.67-81
    • /
    • 1986
  • 냉각탑, 밀폐식냉각탑, 증발식응축기는 증발식냉각기의 분류에 속한다. 열은 증발에 의해 제거되어, 중력에 따라 유하하는 수 film으로 부터 충전물, 또는 밀폐식냉각탑, 증발식응축기의 관군상을 흐르는 공기에 전달된다. 따라서 공기측에서의 열과 물질의 이동프로세스는 기본적으로는 동일하다. 각 형식에서의 차이는 냉각되는 유체측에서의 열저항의 형태가 다르다는 점이다. 이 무저항은 냉각탑에서는 아주 작으나 다른 두 경우에 있어서는 계산상 고려하지 않으면 안된다. 이 논문은 이들 세 형식에 대해 통일된 이론을 적용할 수 있다는 것을 보여주기 위한 것이다. 그러므로 열 및 물질이동저항의 계산을 위한 식에 대해 논의하고 있다. 또한 복잡성을 피하기 위해, Merkel의 근사식을 공기측의 열 및 물질이동계산에 이용하였다.

  • PDF

Thermoacoustic Analysis Considering Flame Location in a Gas Turbine Combustor (가스터빈 연소기에서 화염의 위치를 고려한 열음향 해석)

  • Kim, Daesik;Kim, Sa Ryang;Kim, Kyu Tae
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • Authors' previous works on thermoacoustic(TA) model development showed good results in predicting combustion instability characteristics in a gas turbine combustor. However, they also suggested there were some limitations in growth rate estimation, which might be related with over-simplification of flame structure. As a first trial for improving the model accuracy, the current paper introduces the modified TA model considering the actual flame location in the combustor. The combustor is divided into the unburned and the burned area before and after the flame location, and then acoustic equations are re-organized. The modified TA model results show a better accuracy in predicting the growth rate of instabilities comparing with the previous results. However, obtained results still overestimate the conditions where the combustor goes unstable. Further researches considering heat release distribution through flames are required.

Analytical and Experimental Study on a Thermal Liquid Mass Flow Meter (가열식 액체용 질량유량계측기에 관한 이론 및 실험적 연구)

  • Kim, Taig Young;Kang, Chang Hoon;Shin, Yoon Sub;Kim, Tae Su;Choi, Seon Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.4
    • /
    • pp.309-316
    • /
    • 2015
  • Numerical analysis and experimental verification of a thermal liquid mass flow meter (LMFM) were performed. The configuration of the LMFM was the same as a gas mass flow meter (GMFM), but the opposite results in temperature difference between upstream and downstream thermistors occurred. In the case of the gas, the convection depending on the flow of thermal mass was small and comparable to the conduction through the sensor tube wall. The temperature difference was proportional to the mass flow rate due to their interaction. For the liquid flow, the convection overwhelmed the wall conduction because of the large flow of thermal mass caused by high density. The temperature difference in this case was inversely proportional to the mass flow rate. The tube diameter and heater wiring width are important design parameters, and the optimized sensor can be used to measure and control the infinitesimal liquid flow rate.

Analysis on Signal Transmission of Neuron and Simulation of Action Potential by Sodium ion Concentration (뉴런에서의 신호 전달 해석과 Na 이온농도에 따른 활성전위 시뮬레이션)

  • 김석환;도경선;류광렬;오용선;허창우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.455-459
    • /
    • 2000
  • 신경의 기본단위인 뉴런을 계층 구조형태로 연결하여 자극에 대한 각 뉴런의 신경전달 메카니즘을 분석하고 Na 이온의 값을 변형시켜 활성전위에 미치는 영향을 LINUX를 기초로 한 GENESIS를 이용하여 시뮬레이션을 해 보았다. 뉴런은 미세한 자극뿐만 아니라 이온농도의 변화로 인한 매우 민감하게 반응함으로 신경의 활성전위와 인체를 구성하는 모든 세포에서의 이온농도의 중요성을 간과해서는 안 된다. 본 연구에서는 신경세포를 전기회로 적인 모텔을 기준으로 설계하였으며, 농도의 변화에 의해 활성전위 전달에 큰 변화를 일으켰다. 과대한 농도 변화는 신경에서의 과도한 활성전위와 매우 낮은 전위가 발생함을 알 수 있었다. 이로 인해 인체에 미치는 영향은 신체의 어느 부분이냐에 따라 다르겠지만 뇌에서의 열, 뇌 세포 손상, 근육마비, 심장마비 등의 이상 현상을 추정할 수 있을 것이다.

  • PDF

Study on Application of Wave Travelling Effect and Local Site Effect to Design Standard for Analysing Seismic Behavior of Long-Span Cable-Stayed Bridge (장대사장교의 지진거동 분석시 지반특성 및 파동전달효과를 고려한 설계기준 적용에 대한 고찰)

  • Park, Youn-Soo;Song, Young-Bong;Hyun, Ki-Hwyun;Lee, Soon Nam;Yang, Won Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.167-174
    • /
    • 2008
  • Number of long-span bridge construction has been increased recently so that seismic consideration of design has become significant. To adapt such significance to design, seismic design in the newly revised 'Cable Steel Bridge Design Handbook' specifies some of wave travelling effect and local site effect. In this study, a cable-stayed bridge with main span of 500m is analysed having variables of uniform excitation, wave travelling effect, and wave travelling effect plus local site effect. Result shows that wave travelling effect in cable-stayed bridge affects considerably to its seismic response under weak soil condition even though the span length is relatively short. What's more, regardless of soil type, the seismic response has become higher for analysis with wave travelling effect and local site effect than with wave travelling effect only. Consequently, in seismic response analysis of long-span bridge, consideration should be given to application of wave travelling effect and local site effect.

Simulation of the High Frequency Hyperthermia for Tumor Treatment (종양치료용 고주파 열치료 인체적용 시뮬레이션)

  • Lee, Kang-Yeon;Jung, Byung-Geun;Kim, Ji-won;Park, Jeong-Suk;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.257-263
    • /
    • 2018
  • Hyperthermia supplies RF high-frequency energy above 1MHz to the tumor tissue through the electrodes. And the temperature of the tumor tissue is increased to $42^{\circ}C$ or more to cause thermal necrosis. A mathematical model can be derived a human body model for absorption and transmission of electromagnetic energy in the human model and It is possible to evaluate the distribution of temperature fields in biological tissues. In this paper, we build the human model based on the adult standard model of the geometric shape of the 3D model and use the FVM code. It is assumed that Joule heat is supplied to the anatomical model to simulate the magnetic field induced by the external electrode and the temperature distribution was analyzed for 0-1,200 seconds. As a result of the simulation, it was confirmed that the transferred energy progressively penetrates from the edge of the electrode to the pulmonary tumors and from the skin surface to the subcutaneous layer.

A Numerical Study On Thermal Characteristics of HALE UAV Solar Arrays (HALE 무인기의 태양전지 열특성에 관한 해석적 연구)

  • Song, Ji-Han;Nam, Yoonkwang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.5
    • /
    • pp.29-36
    • /
    • 2017
  • In this study, a numerical analysis is made of the fluid flow and heat transfer characteristics in the solar arrays of HALE (High Altitude Lond Endurance) UAV. In the stratosphere where UAV operates, high level solar radiation is induced, heat transfer decreases due to natural convection and forced convection is dominated by ambient flow. In order to predict the solar array temperature range in this environment condition, the conjugate heat transfer analysis was carried out for the solar arrays on the main wing. The investigation focused on the temperature distribution of solar array and heat transfer characteristics according to influence of solar energy, flight condition as vehicle speed, air density, temperature.

Finite element analysis for the flow characteristics along the thickness direction in injection molding (사출성형시 두께방향으로의 유동특성에 관한 유한요소 해석)

  • 이호상;신효철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.6
    • /
    • pp.1026-1035
    • /
    • 1987
  • The injection molding process is used in the fabrication of a large variety of plastic articles. A numerical simulation of the filling stage along the thickness direction is proposed by combining the free surface boundary condition with the relevant governing equations. The mathematical model is based on the equations of continuity, momentum and energy along with inelastic power-law model and relevant boundary conditions. Due to the significant implications for microstructure development in the pro duct, the fountain effect at the advancing free surface is explicitly taken into consideration in the simulation. The model yields data on free surface shape as well as velocity, pressure, temperature and shear stress distributions within the mold cavity. The rearrangement of the velocity and temperature profiles in the vicinity of the melt front is considered in detail.

Performance Prediction of SOFC using Numerical Analysis (전산해석을 이용한 SOFC 성능 예측)

  • Park, S.M.;Oh, T.Y.;Kim, J.Y.;Lee, H.I.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.88.1-88.1
    • /
    • 2011
  • 본 연구에서는 SOFC 시스템 설계기술 개발을 위한 기초 연구로서 전산해석을 이용한 SOFC 성능예측 기법을 개발하였다. 기본설계 단계에서 SOFC의 성능을 개략적으로 예측할 수 있는 1차원 예측 모델을 정립하였으며, 온도, 조성, 전해질, 전극 두께 등을 비롯한 다양한 조건 변화에 따른 성능예측을 수행하여 실험값과 비교한 결과 최대전력밀도 조건에서 23%의 오차를 갖는 것으로 나타났다. 또한 Stack 제작단계에서 다양한 운전조건과 형상변화에 따른 SOFC 성능 변화를 예측할 수 있는 3차원 해석기법을 정립하였으며, 최대전력밀도에서 5.1%의 오차를 보였다. 포괄적인 열 및 물질 전달 현상과 전기화학반응을 3차원적으로 해석함으로써 보다 정확한 예측이 가능하였다. 또한 수소와 적당량의 수분을 함께 공급할 경우 SOFC 성능이 향상되는 것으로 나타났다. 본 연구에서 개발된 기술을 활용할 경우 시제품 제작 전에 전지시스템의 성능을 미리 예측할 수 있으므로, 향후 제품 개발시 제작비용 절감과 설계기간 단축에 기여할 수 있을 것으로 기대된다.

  • PDF