Heat Exchanging Performance as Affected by Arrangement of Heat Exchanging Pipe (열회수장치의 열교환 파이프배치 형식별 열교환 성능)

  • 윤용철;강종국;서원명
    • Journal of Bio-Environment Control
    • /
    • v.11 no.3
    • /
    • pp.101-107
    • /
    • 2002
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared far the comparison of heat recovery performance; A-type is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types (B-type and C-type) modified from the control unit are different in the aspects of airflow direction (U-turn airflow) and pipe arrangement. The results are summarized as follows ; 1. In the case of Type-A, when considering the initial cost and current electricity fee required for system operation, it was expected that one or two years at most would be enough to return the whole cost invested. 2. Type-B and Type-C, basically different with Type-A in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than 25m$^3$.min$^{-1}$ . Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This was assumed to be that air flow resistance in high air capacity reduced the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate of Type-B and Type-C was improved by about 5% and 13%, respectively 3. Desirable blower capacity of these heat recovery units experimented were expected to be about 25m$^3$.min$^{-1}$ , and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it was recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., was required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

Modification of GGH Leakage Evaluation Equations in Wet FGD System (습식 배연탈황공정에서 GGH 누설률 평가식의 수정)

  • 천성남;안영모;장경룡
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.387-388
    • /
    • 2003
  • 습식 배연탈황 공정에서는 흡수탑 내에서의 황산화물 흡수율을 높일 목적으로 흡수탑으로 유입되는 배기가스를 약 5$0^{\circ}C$까지 냉각하고, 처리된 배기가스는 연돌에서의 자연 통풍력을 확보하고 연돌 배출 후 수분의 응축으로 인한 백연(white Plume)의 문제를 방지하고자 통상 9$0^{\circ}C$ 이상으로 가온하는 것이 일반적이며 이를 위해 다양한 형식의 열교환기가 설치 운영되고 있다. 탈황공정에서 흔히 GGH(gas to gas heater)라 불리는 Ljungstrom 방식의 열 교환기는 미처리된 고온가스와 처리된 저온 가스가 회전하는 열교환소자로 이루어진 영역을 지나면서 열 교환이 이루어지는 형태로 회전 부위 및 두 가스흐름의 구분 판(sector plate) 등에서 필연적으로 처리가스 흐름 중으로 미처리 가스의 누입이 일어나게 된다. (중략)

  • PDF

Heat Exchange Performance of Improved Heat Recovery System (개량형 열회수 시스템의 열교환 성능 실험)

  • 서원명;윤용철;권진근;박성우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2003.04a
    • /
    • pp.152-156
    • /
    • 2003
  • 우리나라 시설원예 면적은 최근 정체되는 기미를 보이긴 하지만, 아직도 시설원예 면적이 50,000ha 이상에 달하고 난방면적도 점점 증가되어 전체 면적 중에 난방면적이 차지하는 비율은 현재 12,300ha 정도인 24%이다. 난방기의 보급기의 보급도 매년 증가하여 '00년말 현재 127,560대 정도이다. 최근 국내 버섯 재배면적의 42% 차지하는 느타리(큰느타리 포함)버섯 재배사도 연중재배를 위하여 난방을 실시하는 농가가 점점 늘고 있고, 특히 새송이(큰느타리) 버섯 재배사의 대부분은 간이형 온실에서 냉난방 설비를 갖추어 연중재배를 하고 있다. (중략)

  • PDF

Small-Dimensional Thermo-optic MMI Switch with Improved Response-time (MMI를 이용한 빠른 응답특성의 소형 열광학 스위치)

  • 이진표;홍종균;이상선
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.166-167
    • /
    • 2003
  • 실리콘 기판 위에 제작되는 실리카 물질은 낮은 가격, 파이버와의 높은 결합 효율 그리고 고집적화의 장점으로 PLC(Planar Light Circuit)에 사용되고 있다. PLC 광소자 중에서 열 광학 스위치(Thermo-optic switch)는, NⅹN 매트릭스 스위치와 Add/drop multiplexer 등 비교적 낮은 속도를 갖는 광 신호 처리를 위해 중요한 소자이다. 기존의 열 광학 스위치의 경우, 방향성 결합기를 사용한 Mach-Zehnder 구조로써, 위상 제어단에서 두 도파로 간의 광 전력 교환을 막기 위해 방향성 결합기의 양쪽 끝단에에 굽은 도파로를 이용한다. (중략)

  • PDF

직접 접촉방식 열 및 물질교환 장치의 전달현상(II)

  • 김석현
    • Journal of the KSME
    • /
    • v.25 no.5
    • /
    • pp.413-418
    • /
    • 1985
  • 직접 접촉식 교환장치(이하 직접 교환기라 함)에서 액체의 유통형태의 선택은 매우 다양하며 전달계수 역시 개별적인 상황이나 충전물의 종류에 따라서 달라지므로 일률적으로 제시되지 못 하고 있다. 많은 경우 실험을 통하여 열전달 또는 물질전달계수를 측정하게 되나 개수로, 자유 낙하액체막, 액체분류와 같이 이상화가 가능한 경우, 이러한 전달계수를 구하기 위하여 이론적 또는 반실험적인 해석을 수행하기도 한다. 수많은 관련 연구결과들은 층류유동에 관한 것과 난류유동의 경우로 구분되고(예상되듯이 대부분의 직접교환기의 유통영역은 난류쪽이다), 난류 유통의 해석은 다시 표면갱신이론(surface renewal model), 와류확산계수모델(eddy diffusivity model-macroscopic), 미분형와류모델(differential eddy diffusivity model)로 대별된다. 여기서는 수많은 교환기형태의 자료정리보다 상기와 같이 대별된 액체측 유동영역별로 전달현상해석의 방법을 간단히 정리하고자 한다.

  • PDF

The hot water production through the combination of solar thermal energy and freon gas compression heat (태양열과 프레온 기체 압축열 복합온수기 개발)

  • Jung, Hyun-Chai;Kim, Ki-Sun;Sun, Kyung-Ho;Nam, Sung-Young;Lee, Jong-Won
    • Solar Energy
    • /
    • v.10 no.2
    • /
    • pp.18-27
    • /
    • 1990
  • The hot water producer by the combination of the solar thermal energy and freon gas compression heat has been developed. Freon R-12 gas was circulated through the system including the solar absorption panel, which has no glassing and no insulation, and the frozen and burst problems were intrinsically eliminated. The manufacturing and running costs may go further down than the regular solar hot water systems.

  • PDF

Experiments on the Characteristic of Storage Tank in In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열시스템의 축열조 특성 실험)

  • 최인수;김재돌;윤정인
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.366-371
    • /
    • 2000
  • 본 연구는 동적형 빙축열시스템에 있어서 증발판이 축열조 상부에 설치되어 생성된 얼음을 주기적으로 분리, 이탈시켜 하부에 설치된 축열조에 저장하는 기존의 하베스트형 빙축열시스템과는 반대로 축열조 내에 증발판을 설치하여 수중에서 얼음을 생성시키고 분리시켜 부럭에 의해 얼음을 띄워 저장하는 새로운 방식의 수중 하베스트형 빙축열시스템 개발에 관한 연구이다. 본 방식은 축열조 내에 증발판이 설치되어 제빙과 탈빙이 이루어짐으로서 기존 시스템에 설치되는 순환펌프나 순환수 분배기 및 배관 등의 설비가 불필요하고, 또한 조내 물과 증발판이 직접접촉에 의해 열교환이 이루어지므로 기존 공기 중에서의 열교환 방식보다 전열효율이 우수한 장점을 가지고 있다. 따라서 본 연구에서는 상기의 수중 빙제조 방식에있어 빙 제조시와 방냉시 축열조의 열특성을 실험적으로 밝혀 시스템 최적화 및 성능 향상에 대한 기초 자료를 제공하고자 하였다.

  • PDF

The Program Coding Technology for the heat Load Prediction in Switching Room (통신시스템실 열부하 예측프로그래밍 기술)

  • Noh, H.K.
    • Electronics and Telecommunications Trends
    • /
    • v.14 no.5 s.59
    • /
    • pp.111-114
    • /
    • 1999
  • 전화국사 내 교환기의 신설이나 증설 시에 최적의 열부하 산정이 필요하다. 이를 위해 전화국사의 특성에 알맞은 열부하 계산 프로그램을 윈도우용으로 개발하여 비전문가들도 쉽게 사용할 수 있도록 하고자 한다. 프로그램 구성은 기본자료입력부, 전화국사의 자료입력부, 입력된 데이터를 이용하여 국사의 냉방부하와 냉방시스템의 용량을 계산하는 부분 그리고 출력부분으로 크게 4부분으로 나눌 수 있다. 본 프로그램을 이용하여 한국통신 중앙전화국 5ESS실의 냉방기기용량을 산정해 본 결과, 기존 냉방기기 69USRT의 49%에 해당되는 33.5USRT로 나타나 기존 냉방기기의 용량이 너무 과다하게 선정되었음이 판명되었다. 본 프로그램은 전화국사의 에너지 절약에 기여할 수 있을 것으로 판단된다.

Inspection of Heat Exchanger Tubing Defects with Ultrasonic Guided Waves (유도초음파를 이용한 열 교환기 튜브 결함 탐상)

  • Shin, Hyeon-Jae;Rose, Joseph L.;Song, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • This study shows the defect detection and sizing capability of ultrasonic guided waves in the nondestructive inspection of heat exchanger and steam generator tubing. Phase and group velocity dispersion curves for the longitudinal and flexural modes of a sample Inconel tube were presented for the theoretical analysis. EDM(Electric Discharge Machining) wears in tubing under a tube support plate and circumferential laser notches in tubing were detected by an axisymmetric and a non-axisymmetric transducer set up, respectively. EDM wears were detected with L(0, 2), L(0, 3) and L(0, 4) modes and among them L(0, 4) mode was found to be the most sensitive. It was also found that the flexural modes around L(0, 1) mode could be used for the detection and sizing of laser notches in the tubing.

  • PDF

Rational Efficiency of Compression Processes by the Second Law of Thermodynamics (열역학 제2법칙에 의한 압축과정의 합리적 효율)

  • 정평석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1200-1210
    • /
    • 1990
  • Conventional efficiencies of the adiabatic compression process such as isentropic efficiency and polytropic efficiency can be explained as exergetic efficiencies replacing the reference atmospheric temperature with the temperature which can be determined in the process itself. So that, other efficies such as maximum isentropic efficiency can be defined by giving proper reference temperatures. By applying the same logical principles, exergetic and other rational efficiencies for the non-adiabatic compression process are also defined and discussed for their physical meanings and reasonable engineering applications.