Numerical Analysis on Heat Gain of Liquid from Ambient Air with Various Fin Heights and Pitches of Fin-and-Tube Heat Exchanger in Hybrid Solar Collector (핀-튜브 열교환 구조를 갖는 복합집열기에서 핀 높이 및 간격에 따른 공기열 이용 액체 가열 성능에 관한 수치해석 연구)

  • Choi, Hwi-Ung;Fatkhur, Rokhman;Lyu, Nam-Jin;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.53-61
    • /
    • 2016
  • Solar assisted heat pump system uses solar thermal energy as a heat source of evaporator of heat pump. So, COP can be enhanced as well as collector efficiency. For improving performance of this system, some research about hybrid solar collector that has fin-and-tube heat exchanger has been conducted. This collector can get a thermal energy from ambient air for liquid heating, so heated liquid can be used as a heat source of evaporator in heat pump even the solar radiation is not enough. In this study, numerical analysis was conducted for confirming heat gain of liquid according to fin height and pitch of fin-and-tube heat exchanger in collector. As a result, higher heat gain was obtained on lower fin height and narrow fin pitch, but the pressure drop also increased with increment of heat gain. Thus the JF factor considering both heat transfer enhancement and pressure drop was investigated and the maximum value was shown when the fin height and pitch were 40mm and 45mm. So it is considered that this installation condition has a highest heat transfer improvement when comparing with pressure drop. However heat gain of liquid at this condition was less than the other installation conditions of fin pitch on same height. Then, after establishing a proper minimum heat gain of liquid, actual production and experiment of collector will be conducted with fin height and pitch showing maximum JF factor and satisfying selected minimum heat gain of liquid on the basis of results of this study.

Experimental analysis of heat exchanger performance produced by laser 3D printing technique (레이저 3D 프린팅 기법으로 제작한 열교환기 성능시험 분석 연구)

  • Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.270-276
    • /
    • 2020
  • 3D printing is an additive manufacturing technology that can produce complex shapes in a single process for a range of materials, such as polymers, ceramics, and metals. Recent 3D printing technology has developed to a level that enables the mass-production through an improvement of the printing speed and the continuous development of applicable materials. In this study, 3D printing technology using a laser was applied to manufacture a heat exchanger for an air compressor in a railway vehicle. First, the optimal design of the heat exchanger was carried out by focusing on weight reduction and compactness as a shape suitable for 3D printing. Based on the design derived, heat exchanger prototypes were made of AlSi10Mg alloy material by applying the SLM technique. Moreover, the manufactured prototypes were attached to an existing air compressor, and the heat exchange performance of the compressed air was tested. The test results of the 3D printed prototypes showed a heat exchange performance of approximately 80% and 85% at low and high-pressure, respectively, compared to the existing heat exchanger. From the 𝓔-NTU method results with an external cooling air condition similar to that of the existing heat exchanger, the calculated heat transfer amount of 3D printed parts showed similar performance compared to the existing heat exchanger. As a result, the 3D printed heat exchanger is lightweight with good performance.

Coal gasification and A new IGCC system (석탄가스화와 새로운 IGCC 시스템)

  • Kim, Hyun-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.361-363
    • /
    • 2008
  • 탄소 개질반응은 $1200^{\circ}C$(도1) 이상에서 모든 탄화물질과 수분 또는 $CO_2$ 사이에서 흡열/환원반응이 일어나서 합성가스를 생성한다. 개질반응로는 산화반응로와 연결되어, 수소가스와 CO 가스의 혼합인,합성가스가 산화반응로 내에서 산소가스와 연소하여 열과 $H_2O+CO_2$를 생성하여 환원 반응로 내로 유입되어, 환원 반응로를 $1200^{\circ}C$ 이상으로 유지하고, $H_2O$$CO_2$는 석탄 속의 모든 탄소를 CO로 개질한다(도2). 동시에 수소가스가 생성되어 합성가스를 생성하게 된다. 석탄 속의 비탄소 물질인 슬래그(Slag)는 개질로 내에 남게 되는데, 개질로를 슬래그 융점(non-fluid point) 이하에서 고체상태로 포집함으로서 Fly-ash로 처리된다. 개질로 내의 온도를 $1200{\sim}1300^{\circ}C$(석탄 슬래그 융점)로 유지함으로서 개질반응이 지속되어 합성가스가 생성된다. IGCC 시스템에서는 합성가스를 가스터빈 속에서 $O_2E가스와 연소하여 고온의 가스를 생성하여 터빈을 가동해 발전을 하고 배출가스를 $1500{\sim}1700^{\circ}C$에서 배출한다. 재래식 IGCC(도4)에서는 ${\sim}1500^{\circ}C$의 배출가스를 열교환 시스템에 의해 증기를 생성하여 Steam turbine(증기터빈)을 가동하여 추가 전력을 생산했다. 그러나 본 시스템에서는 배출가스(증기와 $CO_2E 가스)를 위의 개질로에 유입하여 개질로 온도를 $1200{\sim}1300^{\circ}C$로 유지함으로서 더 많은 합성가스를 생성 하게 된다(도3). 이렇게 하여 Oxidation-reduction cycle을 형성하게 된다. 새로운 IGCC 시스템에서 가스 터빈의 배출가스가 석탄 개질로에 연결되고 석탄개질로의 합성가스 출구가 가스터빈의 가스 입구에 연결됨으로서,외부에너지 주입 없이 지속 가능한 가스화 반응과 터빈 사이클(Cycle)을 완성하여 IGCC 시스템의 석탄 열효율을 1단계 상승시켰다. 이렇게 설계된 석탄가스화기는 Lurgi형 석탄가스화 기와 달리 석탄개질반응의 효율을 높일 수 있고, 슬래그 처리가 간단하기 때문에 석탄가스화기가 소형화 될 수 있으며 슬래그(Slag)용융에 따른 석탄가스화기의 외벽손상을 피할 수 있다.

  • PDF

Preparation and Characterization of PVA/PSSA-MA Electrolyte Membranes Containing Silica Compounds for Fuel Cell Application (실리카 화합물을 함유한 PVA/PSSA-MA 전해질 막의 제조 및 특성과 연료전지로의 응용)

  • Byun, Hong-Sik;Kim, Dae-Hoon;Lee, Byung-Seong;Lee, Bo-Sung;Yoon, Seok-Won;Rhim, Ji-Won
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.336-344
    • /
    • 2008
  • This manuscript deals with the investigation of the possibility of the crosslinked poly(vinyl alcohol) membranes with both poly(styrene sulfonic acid-co-maleic acid) and 3-(trihydroxysilyl)-1-propanesulfonic acid (THS-PSA) for the fuel cell application. The studies were focused on the characterization of the resulting membranes through water content, thermal gravimetric analysis, ion exchange capacity, ion conductivity and methanol permeability measurements and then compared with the existing Nafion membrane. Typically, the ion conductivity lied in the range of $10^{-3}$ to $10^{-2}\;S/cm$ while the methanol permeability showed the range of $10^{-6}$ to $10^{-8}\;cm^2/s$.

Simulation by heat transfer of ADS process for large sized polycrystalline silicon ingot growth (대형 다결정 실리콘 잉곳 성장을 위한 ADS 법의 열유동에 관한 공정모사)

  • Shur, J.W.;Hwang, J.H.;Kim, Y.J.;Moon, S.J.;So, W.W.;Yoon, D.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.1
    • /
    • pp.45-49
    • /
    • 2008
  • The development of manufacturing process of silicon (Si) ingots is one of the important issues to the growth of the photovoltaic industry. Polycrystalline Si wafers shares more than 60% of the photovoltaic market due to its cost advantage compared to mono crystalline silicon wafers. Several solidification processes have been developed by industry including casting, heat exchange method (HEM) and electromagnetic casting. In this paper, the advanced directional solidification (ADS) method is used to growth of large sized polycrystalline Si ingot. This method has the advantages of the small heat loss, short cycle time and efficient directional solidification. The numerical simulation of the process is applied using a fluid dynamics model to simulate the temperature distribution. The results of simulations are confirmed efficient directional solidification to the growth of large sized polycrystalline Si ingot above 240 kg.

Extraction and Chemical Composition of Soluble Polysaccharide from Green Laver, Enteromorpha prolifera (가시파래 수용성 다당의 추출 및 화학적 조성)

  • Choi Yong Seok;Koo Jae Geun;Ha Jin Hwan;Yoon Jang Tak
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.5
    • /
    • pp.519-523
    • /
    • 2002
  • Soluble polysaccharide (SP) from green layer, Enteromorpba prolifera was extracted 3 times with distilled water at 100$^{\circ}C$ for 2 hrs and fractionated with cetylpyridinium chloride (CPC) and ion exchange chromatography (DEAE Separose CL-6B). The SP amounted to $23.7\%$ of the dry seaweed weight and contained $68.8\%$ carbohydrate. It was mainly constituted of rhamnose, glucose, xylose, sulfate and uronic acid and was fractionated with CPC into three (CPC-S, CPC-PS, CPC-PP) tractions. The major acid fraction CPC-PS accounted for $10.2\%$ of the dry algal weight. CPC-PS was further fractionated on DEAE Sepharose CL-6B into Fr-1 ($8.0\%$), Fr-2 ($35.8\%$), Fr-3 ($23.7\%$) fractions. The Fr-3 fraction contained $2.2\%$ protein, $21.4\%$ sulfate, $15.3\%$ uronic acid, and $72.4\%$ polysacchnrides composed of rhamnose, xylose and glucose. The Fr-2 fraction, which was richer in uronic acid ($17.5\%$) and poorer in sulfate ($19.0\%$) and total sugar ($68.8\%$) than the Fr-3, had a sugar composition close to that of Fr-3. The average molecular weights of Fr-2 and Fr-3 were 510,000 and 830,000 daltons, respectively. Fr-3 turned out to be homogeneous by cellulose acetate electrophoresis.

Safety Performance Evaluation of Technical Independence 5kW Class Fuel Cell System (기술자립형 5kW급 건물용 연료전지시스템 안전성능 평가)

  • Lee, Jungwoon;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.82.1-82.1
    • /
    • 2011
  • 최근 국내에서 발생된 대규모 정전사태로 인해 안정적인 전력공급에 대한 국민들의 요구가 커져, 지난 3월 일본 후쿠시마 원전사고 이후 다시 한번 분산전원에 대한 필요성이 대두되어지고 있다. 여러 분산전원 중 연료전지는 다른 에너지원에 비해 에너지의 지속성이 우수하여 가장 안정적인 분산전원 형태의 하나이다. 이에 따라 국내의 경우 우수한 도시가스 인프라로 인해 건물용 연료전지라는 신기술에 대한 국민의 수용성은 점점 높아질 것으로 기대된다. 현재 건물용 연료전지의 경우, 주로 1kW급 연료전지가 시범보급되어 각 가정에 설치되어지고 있으나, 상가, 주유소 및 편의점 등의 상업시설과 생활관 및 소형빌라 등의 집단 주거시설 같은 1kW급 보다 용량을 더 필요로 하는 응용처에 국내에서 개발된 5kW급 연료전지시스템이 적용되어지기를 기대한다. 본 연구에서는 국내 제작된 5kW급 고분자전해질 연료전지시스템의 보급이전에 안전성능 평가를 통해 시스템의 성능 및 안전성 평가결과를 제조사에 피드백 하여 5kW급 건물용 연료전지시스템의 조기 상업화에 앞장서고자 한다. 5kW급 연료전지시스템의 기술개발은 핵심부품인 연료변환기, 스택 및 BOP 기술의 경우 1kW급 연료전지시스템에 적용된 것과는 다른 기술이 필요하고, 단순한 scale-up 과정이 아닌 새로운 기술개발로 제품에 적용시켜야 하는 난점을 가지고 있다. 특히, 연료변환기의 경우 연료 유량의 증가로 인하여 reformer, CO shift 및 Prox 반응기의 유체역학, 열교환 흐름 및 촉매반응 공학적으로 이론을 응용한 새로운 반응기 설계와 제작기술 확립이 선행되어 전체적인 시스템 제작 설계에 반영되어져야 한다. 그러므로 본 연구에서는 연료전지시스템 안전성능 평가를 위해 용량증대에 따른 안전성평가 항목을 검토하고, 5kW급 연료전지시스템평가를 수행하여 시스템의 제품성능, 작동성능 및 계통연계성능에서의 안전성을 확인하였고, 정전 유풍과 같은 이상조건 및 실외 환경에 대한 시스템의 안전성도 확인하였다. 또한 부하운전 조건을 75% 및 50%로 변화시켰을 때 빠른 응답시간과 안정적인 부하변동운전을 확인하였다.

  • PDF

Sizing of Vertical Borehole Heat Exchangers using TRNOPT (TRNOPT를 이용한 수직 지중열교환기 길이 산정 방법에 관한 연구)

  • Park, Seung-Hoon;Lee, Hyun-Soo;Jang, Young-Sung;Kim, Eui-Jong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.402-407
    • /
    • 2016
  • Ground-coupled heat pump systems have been widely used, as they are regarded as a renewable energy source and ensure a high annual efficiency. Among the system components, borehole heat exchangers (BHE) play an important role in decreasing the entering water temperature (EWT) to heat pumps in the cooling season, and consequently improve the COP. The optimal sizing of the BHEs is crucial for a successful project. Other than the existing sizing methods, a simulation-based design tool is more applicable for modern complex geothermal systems, and it may also be useful since design and engineering works operate on the same platform. A simulation-based sizing method is proposed in this study using the well-known Duct STorage (DST) model in Trnsys. TRNOPT, the Trnsys optimization tool, is used to search for an optimal value of the length of BHEs under given ground loads and ground properties. The result shows that a maximum EWT of BHEs during a design period (10 years) successfully approaches the design EWT while providing an optimal BHE length. Compared to the existing design tool, very similar lengths are calculated by both methods with a small error of 1.07%.

Thermal Behavior of Vertical Ground Heat Exchanger by Numerical Simulation (수치해석을 통한 수직 밀폐형 지중열 교환기의 열전달 거동 연구)

  • Gil, Hu-Jeong;Lee, Chul-Ho;Kim, Ju-Young;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1638-1646
    • /
    • 2008
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 2-D finite element analysis, ANSYS, was employed to evaluate the temperature distribution on the borehole cross section involving HDPE pipe/grout/soil formation to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system which is equipped with a thermally insulating latice in order to reduce thermal interference between the inflow and outflow pipes. In addition, a 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of grout's thermal properties, rate of circulation pump, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

Pressure Distribution over Tube Surfaces of Tube Bundle Subjected to Two-Phase Cross-Flow (이상 유동에 놓인 관군의 표면에 작용하는 압력 분포)

  • Sim, Woo Gun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2013
  • Two-phase vapor-liquid flows exist in many shell and tube heat exchangers such as condensers, evaporators, and nuclear steam generators. To understand the fluid dynamic forces acting on a structure subjected to a two-phase flow, it is essential to obtain detailed information about the characteristics of a two-phase flow. The characteristics of a two-phase flow and the flow parameters were introduced, and then, an experiment was performed to evaluate the pressure loss in the tube bundles and the fluid-dynamic force acting on the cylinder owing to the pressure distribution. A two-phase flow was pre-mixed at the entrance of the test section, and the experiments were undertaken using a normal triangular array of cylinders subjected to a two-phase cross-flow. The pressure loss along the flow direction in the tube bundles was measured to calculate the two-phase friction multiplier, and the multiplier was compared with the analytical value. Furthermore, the circular distributions of the pressure on the cylinders were measured. Based on the distribution and the fundamental theory of two-phase flow, the effects of the void fraction and mass flux per unit area on the pressure coefficient and the drag coefficient were evaluated. The drag coefficient was calculated by integrating the measured pressure on the tube by a numerical method. It was found that for low mass fluxes, the measured two-phase friction multipliers agree well with the analytical results, and good agreement for the effect of the void fraction on the drag coefficients, as calculated by the measured pressure distributions, is shown qualitatively, as compared to the existing experimental results.