• Title/Summary/Keyword: 열효과

Search Result 4,000, Processing Time 0.036 seconds

A Study on the Evaluation of Patient Dose in Interventional Radiology (중재적방사선검사에서 환자 피폭선량에 관한 연구)

  • Park, Hyung-Sin;Lim, Cheong-Hwan;Kang, Byung-Sam;You, In-Gyu;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2012
  • To perform patient dose surveys in major interventional radiography procedures as a mean of inter-institutional comparison and of establishing reference dose levels with the ultimate goal of optimizing patient doses in the field of interventional radiography. We reviewed international patient dose survey data in the literature and measured patient dose in major interventional radiography procedures (TACE, AVF, PTBD, TFCA, GDC embolization). ESD(Entrance Skin Dose) was measured using TLD chips attached to the patient skin and ED(Effective Dose) was calculated using angiography unit-derived DAP. A survey of patient dose in interventional radiography procedures were also performed with a questionnaire for interventional radiologists and we proposed a guideline for optimizing patient doses in the field of interventional radiology. The patient dose survey data in interventional radiography procedures were very rare in literature compared with those in diagnostic radiography procedures. In TACE, the mean ED was 25.43 mSv and the mean ESD was 511.75 mGy. The mean ED of TACE was not high, but the cumulative dose should be checked, due to longer procedure TACE. In TFCA, the mean ED was 22.6 mSv and it was relatively high compared with data of other countries. In GDC embolization, the mean ED was not available, because GDC embolization was performed with old Image-Intensifier-type unit and there has no unit-installed ionization chamber. Also, the mean ESD of GDC embolization was up to 2,264 mGy and further studies are needed to calculate the net ED of GDC embolization. Patient dose occurred during interventional radiography procedures are high related with the difficulty of the procedure, fluoroscopy time, the number of angiographies and the treatment protocol. Therefore, continuous education and efforts should be made to optimize the patient dose in the field of interventional radiology.

Effects of Far-infrared Irradiance at Night on Quality of Sunlight Dried Red Pepper (Capsicum annuum L.) in Plastic Houses (비닐하우스 이용 고추 건조 시 야간 원적외선등 조사량이 품질에 미치는 영향)

  • Lee, Guang-Jae;Kim, Si-Dong;Yoon, Jung-Beom;Lee, Ki-Yeol;Choi, Kyu-Hong
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.819-826
    • /
    • 2014
  • This study was carried out to investigate the effects of night-time far-infrared irradiance quality of red pepper dried in greenhouses. This study involved 4 treatments: sunlight alone (control), or sunlight plus nightly far-infrared irradiation at $250W{\cdot}6.6m^{-2}$ ($250W{\cdot}6.6m^{-2}$), far-infrared irradiation at $250W{\cdot}3.3m^{-2}$ ($250W{\cdot}3.3m^{-2}$), or far-infrared irradiation $500W{\cdot}3.3m^{-2}$ ($500W{\cdot}3.3m^{-2}$). The drying periods were 12 days in $500W{\cdot}3.3m^{-2}$ and $250W{\cdot}3.3m^{-2}$, and 14 days in $250W{\cdot}6.6m^{-2}$, and 15 days in the control. The daytime temperature was same among the treatments. The lowest temperature was at $23.8^{\circ}C$ in control, and $29.5-37.2^{\circ}C$ in far-infrared irradiation treatments. The marketable yield was 7-14% higher in far-infrared irradiation treatments compared to the control. The rate of marketability was higher in far-infrared irradiation treatments (93.6-96.3%) than in the control (87.0-87.5%). The American Spice Trade Association (ASTA) value was greatest in the $250W{\cdot}3.3m^{-2}$ treatment, followed by $250W{\cdot}6.6m^{-2}$, then $500W{\cdot}3.3m^{-2}$, and finally the control. Capsaicinoid content showed no regular trend among the treatments. Our results provide an optimized method for reducing drying time of red pepper under sunlight, and improving the quality of dried red pepper.

Isolation and Characterization of Bacillus Strain as a Potential Biocontrol Agent (환경친화적 미생물농약으로서의 잠재성을 가진 세균의 분리 및 특성)

  • Lee, Ye-Ram;Lee, Sang-Mee;Jang, Eun-Young;Hong, Chang-Oh;Kim, Keun-Ki;Park, Hyean-Cheal;g Lee, Sang-Mon;Kim, Young-Gyun;Son, Hong-Joo
    • Journal of Life Science
    • /
    • v.25 no.12
    • /
    • pp.1408-1414
    • /
    • 2015
  • In this study, to retain a stable bacterial inoculant, Bacillus strains showing antifungal activity were screened. The improved production, antifungal mechanism, and stability of the antifungal metabolite by a selected strain, AF4, a potent antagonist against phytopathogenic Botrytis cinerea, were also investigated. The AF4 strain was isolated from rhizospheric soil of hot pepper and identified as Bacillus subtilis by phenotypic characters and 16S rRNA gene analysis. Strain AF4 did not produce antifungal activity in the absence of a nitrogen source and produced antifungal activity at a broad range of temperatures (25-40℃) and pH (7-10). Optimal carbon and nitrogen sources for the production of antifungal activity were glycerol and casein, respectively. Under improved conditions, the maximum antifungal activity was 140±3 AU/ml, which was higher than in the basal medium. Photomicrographs of strain AF4-treated B. cinerea showed morphological abnormalities of fungal mycelia, demonstrating the role of the antifungal metabolite. The B. subtilis AF4 culture exhibited broad antifungal activity against several phytopathogenic fungi. The antifungal activity was heat-, pH-, solvent-, and protease-stable, indicating its nonproteinous nature. These results suggest that B. subtilis AF4 is a potential candidate for the control of phytopathogenic fungi-derived plant diseases.

A Quantification Method for the Cold Pool Effect on Nocturnal Temperature in a Closed Catchment (폐쇄집수역의 냉기호 모의를 통한 일 최저기온 분포 추정)

  • Kim, Soo-Ock;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Cold air on sloping surfaces flows down to the valley bottom in mountainous terrain at calm and clear nights. Based on the assumption that the cold air flow may be the same as the water flow, current models estimate temperature drop by regarding the cold air accumulation at a given location as the water-like free drainage. At a closed catchment whose outlet is blocked by man-made obstacles such as banks and roads, however, the water-like free drainage assumption is no longer valid because the cold air accumulates from the bottom first. We developed an empirical model to estimate quantitatively the effect of cold pool on nocturnal temperature in a closed catchment. In our model, a closed catchment is treated like a "vessel", and a digital elevation model (DEM) was used to calculate the maximum capacity of the cold pool formed in a closed catchment. We introduce a topographical variable named "shape factor", which is the ratio of the cold air accumulation potential across the whole catchment area to the maximum capacity of the cold pool to describe the relative size of temperature drop at a wider range of catchment shapes. The shape factor is then used to simulate the density profile of cold pool formed in a given catchment based on a hypsometric equation. The cold lake module was incorporated with the existing model (i.e., Chung et al., 2006), generating a new model and predicting distribution of minimum temperature over closed catchments. We applied this model to Akyang valley (i.e., a typical closed catchment of 53 $km^2$ area) in the southern skirt of Mt. Jiri National Park where 12 automated weather stations (AWS) are operational. The performance of the model was evaluated based on the feasibility of delineating the temperature pattern accurately at cold pool forming at night. Overall, the model's ability of simulating the spatial pattern of lower temperature were improved especially at the valley bottom, showing a similar pattern of the estimated temperature with that of thermal images obtained across the valley at dawn (0520 to 0600 local standard time) of 17 May 2011. Error in temperature estimation, calculated with the root mean square error using the 10 low-lying AWSs, was substantially decreased from $1.30^{\circ}C$ with the existing model to $0.71^{\circ}C$ with the new model. These results suggest the feasibility of the new method in predicting the site-specific freeze and frost warning at a closed catchment.

The Clinical Features of Pertussis in Infancy (영아 백일해의 임상 양상)

  • Kim, Soon Ju;Kim, Sang-Eun;Kim, Jong-Hyun;Lee, Jung-Hyun;Oh, Jin Hee;Koh, Dae Kyun;Sung, Hwa Young;Yu, Jae-Yon
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.2
    • /
    • pp.167-174
    • /
    • 2009
  • Purpose : Pertussis was very common in the past, but reported cases have dramatically decreased. The improvement of vaccination programs and unreadiness of laboratory confirmation seems to have developed this situation. This study investigated the frequency of pertussis among infants with a paroxysmal cough and compared the clinical characteristics between infants with and without pertussis. Methods : Between June and November 2006, 27 infants admitted to the hospital that were 15-90 days old with a history of a cough for more than seven days were enrolled. The cough was described as: paroxysmal, whooping, and post-tussive vomiting. PCR and cultures for Bordetella pertussis with nasopharyngeal aspirates were obtained. The patients were divided into two groups: (1) the pertussis group that had positive results by PCR or culture; (2) the control group that had negative results by PCR and culture. Clinical and laboratory characteristics were compared between the two groups. Results : Among the 27 cases, five (18.5%) were finally diagnosed with pertussis. Only one out of the five pertussis cases was initially diagnosed with a pertussis-like syndrome on admission. Compared to the group without pertussis, the pertussis group had a significantly higher frequency of: no fever (P =0.043), a paroxysmal cough (P =0.040), cyanosis (P =0.001), non-immunized status for DTaP (P =0.047), normal auscultation (P =0.028), normal chest X-ray findings (P =0.027), high absolute lymphocyte count (P =0.039), and low CRP (P =0.046). The patients with the diagnosis of pertussis had a significantly longer duration of coughing (27.2${\pm}$10.6 vs. 12.6${\pm}$5.6 days, P =0.039). Conclusion : Pertussis should be suspected in any infant with typical symptoms of pertussis in addition to: a persistent cough without fever, accompanied by paroxysms or cyanosis prior to the age of DTaP immunization. Active laboratory confirmation should be carried out to confirm more cases with pertussis.

  • PDF

Effects of Polyimide Passivation Layers and polyvinylalcohol Passivation Layers for Organic Thin-Film Transistors(OTFTs) (폴리이미드 패시베이션과 폴리비닐알콜 패시베이션 레이어 성막이 고성능 유기박막 트렌지스터에 주는 영향)

  • Park, Il-Houng;Hyung, Gun-Woo;Choi, Hak-Bum;Hwang, Sun-Wook;Kim, Young-Kwan
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.195-198
    • /
    • 2008
  • In this paper, it was demonstrated that organic thin-film transistors (OTFTs) were fabricated with the organic passivation layer by vapor deposition polymerization (VDP) processing. In order to form polymeric film as a passivation layer, VDP process was also introduced instead of spin-coating process, where polymeric film was co-deposited by high-vacuum thermal evaporation from 6FDA and ODA followed by curing. In order to investigate by compared with different passivation layer, the other OTFTs is fabricated to passivation by Polyvinylalcohol using spincoating. We can see that two different ways of passivation layer affect electric characteristic of OTFTs. The initial electric characteristic of OTFTs before passivation such as field effect mobility, threshold voltage, and on-off current ratio are $0.24cm^2/Vs$, -3V, and $10^6$, respectively. Then after polyimide passivation layer, field effect mobility change from $0.24cm^2/Vs$ to $0.26cm^2/Vs$, threshold voltage from -3V to 1V and on-off current ratio from $10^6$ to $10^6$, respectively. In the case of polyvinylalcohol passivation, the initial electric characteristic of OTFTs before passivation such as field effect mobility, threshold voltage, and on-off current ratio are $0.13cm^2/Vs$, 0V, and $10^6$, respectively. Then after polyvinylalcohol passivation layer, field effect mobility changes from $0.13cm^2/Vs$ to $0.13cm^2/Vs$, threshold voltage from 0V to 2V, and on-off current ratio from $10^6$ to $10^5$, respectively.

The Effects of Smoking Cessation Coaching Program based on Motivation Stage to Stop Smoking of Patients at a Public Hospital (금연동기단계에 따른 코칭프로그램이 환자 금연에 미치는 영향)

  • Kwak, Mi-Young;Hwang, Eun Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.188-198
    • /
    • 2016
  • This study examined the effects of a smoking cessation coaching program based on the motivation stage applying the Transtheoretical Model to stop the smoking of patients in terms of the amount of smoking, nicotine dependence, CO level, and urine cotinine. The study design was a multi-repeat multiple repeat intermittent time series study with one-group, a pre-post design. The participants were 47 smoking patients (44 males and 3 females), who were treated at a public hospital in N city. The participants were 4 (8.51%) subjects in the action stage and 43 subjects (91.49%) in the preparation stage of the motivation stage. The coaching program intervention was conducted at the first day, second week, and 6th week. The smoking cessation maintenance of the subjects was checked at the 12th week. A chi-square test and t-test were used to analyze the data. The subjects in the action stage were kept under the condition of no smoking and nicotine dependence. After the program of subjects in the preparation stage, the amount of smoking, nicotine dependence, and CO level were significantly lower compared to the pre-test (p<.001). The findings suggest that the coaching program based on the motivation stage was effective in improving the smoking cessation for patients who smoke. On the other hand, the patients in the smoking cessation program may require much more financial assistance than those of healthy people. A greater workforce and budget will be needed for patients to stop smoking.

Changes in the Physicochemical Properties and Sensory Characteristics of Burdock (Arctium lappa) During Repeated Steaming and Drying Procedures (증건 횟수에 따른 우엉의 이화학적 변화 및 관능적 특성 연구)

  • Lee, GeumYang;Son, YangJu;Jeon, YuHo;Kang, HeeJin;Hwang, InKyeoung
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.3
    • /
    • pp.336-344
    • /
    • 2015
  • This study was conducted to investigate changes in the physicochemical, antioxidant, and sensory properties of burdock during 9 repeated rounds of steaming ($90^{\circ}C$, 3 h) and drying ($60^{\circ}C$, 20 h) procedures. The moisture content decreased from 81.95% to 7.64% as the process was repeated. Fresh burdock showed the highest total sugar content, with 518.35 mg/g of soluble sugar, 86% being inulin. The reducing sugar content was the greatest (377.00 mg/g) in burdock that had been processed 3 times. The brown color continuously intensified, reaching its peak at 7 rounds of processing, and then weakened. Crude saponin content was the highest (6.17%) after the 5th processing. Polyphenol content and antioxidant activity (DPPH, ABTS, FRAP) were the highest at the 3rd and 5th procedures, respectively. Repeated processing weakened the grass and root odors and the bitter, astringent, and metallic tastes, whereas it strengthened the sweet and savory odors, caramel flavor, and richness.

Effect of Root Zone Warming by Hot Water on Fruit Characteristics and Yield of Greenhouse- Grown Oriental Melon (Cucumis melo L.) (온수 지중가온이 참외의 과실특성 및 수량에 미치는 영향)

  • 신용습;이우승;연일권;최성국;최부술
    • Journal of Bio-Environment Control
    • /
    • v.6 no.2
    • /
    • pp.110-116
    • /
    • 1997
  • This experiment was conducted to investigate the effects of root zone warming on fruit yield of oriental melon (Cucumis melo L. var. Makuwa) in winter season. Root zone was warmed by hot water flowing through pipe set at 35cm depth from the ridge. Treatments of minimum soil temperature at 20cm depth were 17, 21, $25^{\circ}C$ and non-warming from Jan. 18 to Apr. 18. The results are summarized as follows. 1. The blooming of female flower was faster 1 days in 17$^{\circ}C$ plot, 6 days in 21$^{\circ}C$ plot, and 7 days in $25^{\circ}C$ plot than in control plot and the days from blooming to harvesting were shorter 5 days in 17$^{\circ}C$ plot, 11 days in 21$^{\circ}C$ plot, and 12 days in $25^{\circ}C$ plot than in control plot. 2. Mean fruit weight was the highest in 21$^{\circ}C$ plot, followed $25^{\circ}C$, 17$^{\circ}C$ and control plots, respectively, and flesh thickness was the highest in $25^{\circ}C$ plot, followed by 21, 17$^{\circ}C$ and control plots, respectively. 3. Early and middle-phase yield was the highest in $25^{\circ}C$ plot, followed by 21$^{\circ}C$, 17$^{\circ}C$ and control plots but late yield was the highest in 17$^{\circ}C$ plot, followed by control, 21, and $25^{\circ}C$ plots. Total yield per 10a was higher 33% in 17$^{\circ}C$ plot, 49% in 21$^{\circ}C$ plot, and 37a in $25^{\circ}C$ plots than in control plot, harvested 1, 490kg per 10a. 4. Total yield was highest in 21$^{\circ}C$ plot, followed by $25^{\circ}C$, 17$^{\circ}C$, and control plots. Malformed and fermented fruit rates were the highest in control, followed by 17, 25, and 21$^{\circ}C$ plots and marketable fruit rate was 21, 25, 17$^{\circ}C$, and control plot in order.

  • PDF

Shear bond strength of Universal bonding systems to Ni-Cr alloy (니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도)

  • Song, So-Yeon;Son, Byung-Wha;Kim, Jong-Yeob;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the shear bond strength between Ni-Cr alloy and composite resin using universal adhesive systems coMPared to conventional method using metal primers. Materials and methods: For this study, a total of 120 cast commercial Ni-Cr alloy (Vera Bond 2V) disks were embedded in acrylic resin, and their surfaces were smoothed with silicon carbide papers and airborne-particle abrasion. Specimens of each metal were divided into 6 groups based on the combination of metal primers (Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer) and universal adhesive systems (Single Bond Universal, All Bond Universal). All specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strength testing was performed with a universal testing machine at a cross head speed of 1 m/min. Data (MPa) were analyzed using one-way ANOVA and the post hoc Tukey's multiple comparison test (${\alpha}$=.05). Results: There were significant differences between Single Bond Universal, All Bond Universal, Metal Primer II and Alloy Primer, MKZ Primer, Metal & Zirconia Primer (P<.001). Conclusion: Universal Adhesive system groups indicated high shear bond strength value bonded to Ni-Cr alloy than that of conventional system groups using primers except Metal Primer II. Within the limitations of this study, improvement of universal adhesive systems which can be applied to all types of restorations is recommended especially non-precious metal alloy. More research is needed to evaluate the effect of silane inclusion or exclusion in universal adhesive systems.