Urban Street Planting Scenarios Simulation for Micro-scale Urban Heat Island Effect Mitigation in Seoul (미시적 열섬현상 저감을 위한 도시 가로수 식재 시나리오별 분석 - 서울시를 대상으로 -)

  • Kwon, You Jin;Lee, Dong Kun;Ahn, Saekyul
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.1
    • /
    • pp.23-34
    • /
    • 2019
  • Global warming becomes a serious issue that poses subsidiary issues like a sea level rise or a capricious climate over the world. Because of severe heat-wave of the summer in Korea in 2016, a big attention has been focused on urban heat island since then. Not just about heat-wave itself, many researches have been concentrated on how to adapt in this trendy warming climate and weather in a small scope. A big part of existing studies is mitigating "Urban Heat Island effect" and that is because of huge impervious surface in urban area where highly populated areas do diverse activities. It is a serious problem that this thermal context has a high possibility causing mortality by heat vulnerability. However, there have been many articles of a green infrastructures' cooling impact in summer. This research pays attention to measure cooling effect of a street planting considering urban canyon and type of green infrastructures in neighborhood scale. This quantitative approach was proceeded by ENVI-met simulation with a spatial scope of a commercial block in Seoul, Korea. We found the dense double-row planting is more sensitive to change in temperature than that of the single-row. Among the double-row planting scenarios, shrubs which have narrow space between the plant and the land surface were found to store heat inside during the daytime and prevent emitting heat so as to have a higher temperature at night. The quantifying an amount of vegetated spaces' cooling effect research is expected to contribute to a study of the cost and benefit for the planting scenarios' assessment in the future.

Evaluation of Operation Status for Incineration Facility Using Performance Index (소각시설 이행지표를 활용한 운영 현황 평가)

  • Kim, Jong-Hwan;Park, Joon-Seok;Phae, Chae-Gun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.507-520
    • /
    • 2016
  • This research was performed to evaluate incineration facilities with different scale and type using performance index. Incineration facilities of 28 units, which occupying about 15% of 184 units in nationwide, were selected for questionnaire survey. The facilities were classified in scale with large(${\geq}100t/d$), middle(50~<100 t/d), small(<50 t/d) ones, and in type with stoker, pyrolysis, fluidized bed. Performance index was composed of technological, economical, and environmental items, which have 6, 10, and 30 kinds of questions, respectively. As a result of scale evaluation, large scale facility has higher score than small one in all technological, economical, and environmental items. In overall evaluation of the facilities with different type, stoker incinerator has higher score of 65.3 than 59.0 of fludized bed and 58.3 of pyrolysis. It was shown that there was significant difference in economical evaluation field, in all technological, economical, and environmental items.

Evaluation of Power Generation of Hybrid Energy Harvesting Blocks applying the Piezoelectric Effects and Electromagnetic Induction Principle (압전 및 전자기 유도 기술을 적용한 하이브리드 에너지수확 블록의 발전량 평가)

  • Noh, Myung-Hyun;Lee, Sang-Youl
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.734-737
    • /
    • 2012
  • 에너지하비스팅이란 도시와 자연 환경 속에 상시 존재하지만 진동, 열, 빛 등과 같이 버려지는 에너지 소스로부터 전기를 수확하는 것으로 대용량 발전소와는 다른 신개념의 전기 수확 기술이다. 본 연구에서는 다양한 에너지 하비스팅 기술들 중에서 압전 원리와 전자기 유도 방식을 조합한 하이브리드 에너지 하비스팅 블록에 대한 발전량을 평가하여 에너지 하비스팅 블록의 주택 도시 분야 적용 가능성을 검토하고자 하였다. 이를 위해 랩스케일 PZT 기반 다층 에너지 하베스터의 현 발전량을 평가하여 제시하였고, 증폭기술을 적용하여 개발된 에너지 블록의 발전성능을 다각적으로 평가하여 제시하였다. 또한 개발된 에너지 블록과 기존 상용 제품과의 발전성능 비교 실험을 수행하여 개발된 에너지 블록의 우수성을 입증하였다.

  • PDF

각 환경기온하에서의 성인남자 피부온에 관한 연구

  • 심부자
    • Proceedings of the ESK Conference
    • /
    • 1996.04a
    • /
    • pp.250-251
    • /
    • 1996
  • 인간의 온열환경에 대한 적응은 인간-의복-환경 System사이의 산열과 방열의 열교 환을 통해 보유량을 일정하게 유지하는 항체온 조절에 의해 이루어진다. 이러한 인체와 의 관계와의 열교환은 주로 피부표면을 통해 이루어지므로 피부온은 외계로의 방열을 예측 하여 인간의 체온조절반응을 나타내며, 온열감각을 좌우하는 인자로 의복의 온열생리, 의 복의 보온력, 쾌적성을 평가하는 중요한 생리적인 지표가 되어 착의의 적부를 검토하는 데 의미를 지니면서 의복설게의 기초가 된다. 이에 본 연구는 국내의 기후 및 변화된 온열환경에 적응된 인체의 각 환경기온하에서의 피부온을 기존의 연구와는 달리 장시간의 노출에 의한 변동을 파악하여 쾌적 착의의 관점에서 인체와 환경사이에 존재하는 의복에 있어서 설계의 기초가 되는 피부온의 의의를 재검토함을 목적으로 한다.

  • PDF

A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Winter - Without Heat Loads from Occupancy - (대규모 실내경기장의 동계 온열환경 특성 실측조사 - 인체부하 미고려 조건 -)

  • Choi, Dong-Ho;Jeong, Seong-Jin;Seok, Ho-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.67-77
    • /
    • 2007
  • The purpose of this study is to provide fundamental heating design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with and without heating the space in winter. Heating loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

Analysis of Extreme Rainfall for Evaluation of IDF Curves in Climate Change (기후변화에 따른 IDF곡선 평가를 위한 극한강우 분석)

  • Choi, Jeonghyeon;Lee, Okjeong;Lee, Jeonghoon;Kim, Sangdan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.211-211
    • /
    • 2016
  • 도시 배수 시스템의 설계 및 홍수 방지 전략의 수립은 공통적으로 특정 재현 기간에 대한 극한강우량의 정보가 필요하다. 최근 이상기후로 인한 극한강우사상의 발생이 잦아짐에 따라, 수공 구조물의 설계 및 계획에 기후변화의 영향(특히 강수량)이 고려되어야 한다. 이에 본 연구에서는 설계에 사용되는 일반적인 재현기간의 IDF(intensity duration frequency)곡선에서 극한강우량을 산출하고, 이를 분석한 통계학적인 추세가 기후변화 시나리오의 IDF곡선의 작성에 미치는 영향에 대한 평가를 실시하였다. 연구 첫 단계에는 연 최대 일강수량 시계열의 추세를 분석하고 정량화하였다. 본 연구에서는 1970년부터 2015년까지의 60개 관측소의 연 최대 일강수량 시계열을 사용하여 분석하였으며, 관측소별로 다른 유의수준을 고려하여 Mann-Kendall test가 실시되었다. 그 결과 연구기간동안 증가 및 감소 추세가 발생하였다. 추세가 분석 및 정량화 되면, Gumbel 분포를 이용하여 극한강우량을 계산하였다. 마지막으로 지역별로 실시한 추세분석으로부터 얻은 정보를 통합하고 추세분석 결과를 바탕으로 2가지의 기후 시나리오를 규정하여 IDF곡선의 매개변수를 산정하였다. 그 결과, 통계학적인 추세의 증가 또는 감소 모두 각 지속시간의 극한강우시계열에 영향을 주는 것으로 나타났다.

  • PDF

Modeling of the Adiabatic Temperature Rise of Concrete for Nuclear Power Plants With the Consideration of Binder Components (원전콘크리트의 결합재 조성성분을 고려한 단열온도상승값 예측 모델 개발)

  • Jung, Sang-Hwa;Chae, Seong-Tae;Kim, Do-Gyeum;Moon, Jae-Heum
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.758-761
    • /
    • 2010
  • 본 연구에서는 원전격납구조물과 같이 고품질의 대형 매스콘크리트의 설계, 시공, 품질예측 및 관리에 필요한 구조물 건전성 평가시스템 구축의 일환으로 수화열 예측 프로그램을 개발하였다. 개발된 수화열 예측 프로그램은 국내에서 생산된 시멘트 및 결합재의 화학조성성분, 분말도와 같은 기초정보 및 배합정보를 입력하여 경시변화에 따른 수화발열량을 계산하는 방식으로서 기존의 연구결과를 바탕으로 개발되었다. 개발된 프로그램은 배합환경조건을 고려하여 초기배합온도 3종류(10, 20, $30^{\circ}C$)로 실험한 단열온도상승 실험 결과와 비교해 보았으며, 좋은 상관성을 나타냄을 확인할 수 있었다.

  • PDF

Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile (모바일 기반 온실 냉난방 부하 산정 프로그램 개발)

  • Moon, Jong Pil;Bang, Ji Woong;Hwang, Jeongsu;Jang, Jae Kyung;Yun, Sung Wook
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.419-428
    • /
    • 2021
  • In order to develope a mobile-based greenhouse energy calculation program, firstly, the overall thermal transmittance of 10 types of major covers and 16 types of insulation materials were measured. In addition, to estimate the overall thermal transmittance when the cover and insulation materials were installed in double or triple layers, 24 combinations of double installations and 59 combinations of triple installations were measured using the hotbox. Also, the overall thermal transmittance value for a single material and the thermal resistance value were used to calculate the overall thermal transmittance value at the time of multi-layer installation of covering and insulating materials, and the linear regression equation was derived to correct the error with the measured values. As a result of developing the model for estimating thermal transmittance when installing multiple layers of coverings and insulating materials based on the value of overall thermal transmittance of a single-material, the model evaluation index was 0.90 (good when it is 0.5 or more), indicating that the estimated value was very close to the actual value. In addition, as a result of the on-site test, it was evaluated that the estimated heat saving rate was smaller than the actual value with a relative error of 2%. Based on these results, a mobile-based greenhouse energy calculation program was developed that was implemented as an HTML5 standard web-based mobile web application and was designed to work with various mobile device and PC browsers with N-Screen support. It had functions to provides the overall thermal transmittance(heating load coefficient) for each combination of greenhouse coverings and thermal insulation materials and to evaluate the energy consumption during a specific period of the target greenhouse. It was estimated that an energy-saving greenhouse design would be possible with the optimal selection of coverings and insulation materials according to the region and shape of the greenhouse.