• Title/Summary/Keyword: 열환경 평가

Search Result 936, Processing Time 0.033 seconds

A Large-Scale 3D Visualization System for Port Container Terminal Simulation (항만 컨테이너 시뮬레이션을 위한 대규모 3D 가시화 시스템 개발)

  • Ok, Soo-Yol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.119-126
    • /
    • 2015
  • In this paper, we propose a 3D visualization system that expresses the simulation results of port container operation monitoring and planning in terms of the movements of the surrounding environment including static and dynamic objects. It also enables us to objectively evaluate the operation model by way of animating the actual port operations. With XML-based design of object states, the port simulator visualization system (PSVS) that we propose has been implemented so as to maximize the interoperability with the existing port operation simulation (CATOS), and express the realtime animation of large-scale objects. The design method of PSVS system is explained, and its validity is experimentally examined.

The Investigation for the Cases and Cause of the Failures of the EPDM Sealed SOVs Used in the High Temperature Circumference (고온주변에서 사용되는 에틸렌-프로필렌-디엔 합성고무 봉인물질을 가진 솔레노이드구동밸브의 작동실패 사례 및 원인 분석)

  • Lee J.;Seo J. K.;Park C. T.;Kim Y. I.;Yoon J.
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.82-85
    • /
    • 2004
  • EPDM 봉인물질을 가진 SOV의 작동실패 사례 및 원인을 분석해보면 많은 SOV 고장(SOV failures)은 결국 EPDM 봉인물질이 원인인 것으로 나타났다. SOV 고장은 SOV가 그것의 설계 범위를 초과하는 주위 온도(ambient temperature)에 노출되어 있었기 때문에 발생되었다. 그러한 SOV 고장은 증기누설, 주위 온도의 부정확한 평가 등의 원인에 의해 발생되었다. 또한 SOV 고장은 연속적인 coil의 여기시 발생하는 가열(heatup from energization)로 인해 수명이 단축되는 영향이 서비스 수명 기간에 적절하게 포함되지 않았기 때문에 발생되었다 많은 발전소 운용자는 이러한 사실을 알고 있지 못하였으며 결과적으로 서비스 수명 기간이 과도 예측되는 결과가 초래되었다 SOV의 또 다른 연성(Soft) 봉인물질로, 열저항 특성이 EPDM에 비해 약 $50^{\circ}C$ 정도 우수한 Viton 봉인물질에 대한 특성이 제시되었다. 더불어 현재 많은 국외 솔레노이드구동밸브 전문 생산업체들이 Viton 재료를 옵션으로 채택하고 있는 추세이다. 그러나 고온주변에서 지속적으로 노출되어 있는 환경에서 Viton이 EPDM의 문제점을 어느 정도 해결할 수 있는 지의 여부는 현재 결론 내리기 어려울 것으로 판단되며, 향후 이를 채택한 SOV의 운전경험을 계속 주시할 필요가 있을 것으로 판단된다.

  • PDF

Applicability Assessment of the Automatic Multi-segmented Rating Curve (자동구간분할 수위-유량관계 곡선식의 적용성 평가)

  • Kim, Yeonsu;Kim, Jeongyup;An, Hyunuk;Jung, Kwansue;Oh, Sungryul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.548-548
    • /
    • 2016
  • 수위-유량관계 곡선식은 시계열 수위자료를 유량자료로 변환해줄 수 있는 회귀식으로 측정단면의 형태, 단면 상 하류의 지형요인 등으로 인하여 영향을 고려하기 위하여 기간분할 혹은 구간분할을 수행한다. 구간분할을 위하여 측정단면의 변화를 고려한 관계자의 주관적인 판단이 주요 근거로 이용되고 있다. 따라서 본 연구에서는 기존에 개발된 수위-유량관계 곡선식의 자동구 구간분할방법에 대한 적용성 검토를 수행하였다. 객관화된 분할근거의 제시를 위하여 주관성을 배제하고 관측데이터를 기반으로 수위 증가에 따른 변동계수를 계산하였고, 변동계수가 정규분포를 따르는 것으로 가정 하에 계산된 변동계수가 전 단계에서 계산된 95% 신뢰구간 이내에 존재하지 않는 경우 구간을 분할하였다. 즉, 변동계수를 이용하여 집단 간의 특성을 비교하였으며, 변동 계수의 분포를 이용하여 분할을 위한 기준 값을 제시하였다. 방법론의 추정능력 검토를 위하여 가상의 곡선으로부터 생성된 데이터에 제안된 방법론을 적용하였고, 실제 유역에 적용성 검토를 위하여 금강에 위치한 무주 및 산계교 수위관측소 지점에 적용하였다. 결과적으로 자동으로 분할된 관계곡선식을 사용하여 추정의 정확도를 높일 수 있을 뿐만 아니라 외삽을 하는 경우 역시 그 정확도를 향상할 수 있음을 확인하였다. 마지막으로 실측값을 활용한 수위-유량관계 곡선식의 구축 시 구간 분할 전 후의 잔차데이터에 대하여 Shapiro-wilk 정규성 검정을 수행하였으며, 구간분할 후 잔차가 정규성을 갖게 되는 것으로 나타났다.

  • PDF

Proposal of Soil Parameter Range of HSPF Considering Available Water Capacity According to Soil Layer (토양층에 따른 유효수분량을 고려한 HSPF의 토양 별 매개변수 범위 제안)

  • Kim, SooHong;Lee, Dongjun;Han, JeongHo;Yang, DongSeok;Kim, JongGun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.113-113
    • /
    • 2019
  • 하천 오염 부하의 양적 증가를 해결하기 위해 환경부는 유역 내 목표 수질을 설정하고 목표 수질한도 내에서 오염물질 배출 총량을 할당하는 수질오염총량제를 도입하였다. 수질오염총량제 시행에 있어 시계열로 발생하는 유출특성을 반영하기 위해 장기유출모형의 적용이 가능한 Hydrologic Simulation Program-Fortran(HSPF)을 수질관리 및 평가 모델로 사용하고 있다. 그러나 HSPF 모델은 실제 다양한 특성을 가진 토양층을 Upper zone과 Lower zone 내에 통합적인 매개변수를 이용하여 유량을 모의하는 문제점이 있다. 이는 토양 내부에서의 유출에 대한 정확한 모의가 이루어지지 않는 결과를 초래할 수 있다. 따라서 본 연구에서는 국내 토양층에 따른 Available Water Capacity(AWC)에 대한 자료를 구축하고 기존보다 세분화된 토양 관련 매개변수 범위를 제시하였다. 본 연구에서 제시한 토양 관련 매개변수 범위를 반영할 경우 수질오염총량제 시행에 있어 HSPF 모델 모의 시 유역 내의 토양도를 고려하여 보다 정확한 중간유출과 기저유출분석이 가능할 것이라 사료된다.

  • PDF

The Bi-Cross Pretraining Method to Enhance Language Representation (Bi-Cross 사전 학습을 통한 자연어 이해 성능 향상)

  • Kim, Sung-ju;Kim, Seonhoon;Park, Jinseong;Yoo, Kang Min;Kang, Inho
    • Annual Conference on Human and Language Technology
    • /
    • 2021.10a
    • /
    • pp.320-325
    • /
    • 2021
  • BERT는 사전 학습 단계에서 다음 문장 예측 문제와 마스킹된 단어에 대한 예측 문제를 학습하여 여러 자연어 다운스트림 태스크에서 높은 성능을 보였다. 본 연구에서는 BERT의 사전 학습 문제 중 다음 문장 예측 문제에 대해 주목했다. 다음 문장 예측 문제는 자연어 추론 문제와 질의 응답 문제와 같이 임의의 두 문장 사이의 관계를 모델링하는 문제들에 성능 향상을 위해 사용되었다. 하지만 BERT의 다음 문장 예측 문제는 두 문장을 특수 토큰으로 분리하여 단일 문자열 형태로 모델에 입력으로 주어지는 cross-encoding 방식만을 학습하기 때문에 문장을 각각 인코딩하는 bi-encoding 방식의 다운스트림 태스크를 고려하지 않은 점에서 아쉬움이 있다. 본 논문에서는 기존 BERT의 다음 문장 예측 문제를 확장하여 bi-encoding 방식의 다음 문장 예측 문제를 추가적으로 사전 학습하여 단일 문장 분류 문제와 문장 임베딩을 활용하는 문제에서 성능을 향상 시키는 Bi-Cross 사전 학습 기법을 소개한다. Bi-Cross 학습 기법은 영화 리뷰 감성 분류 데이터 셋인 NSMC 데이터 셋에 대해 학습 데이터의 0.1%만 사용하는 학습 환경에서 Bi-Cross 사전 학습 기법 적용 전 모델 대비 5점 가량의 성능 향상이 있었다. 또한 KorSTS의 bi-encoding 방식의 문장 임베딩 성능 평가에서 Bi-Cross 사전 학습 기법 적용 전 모델 대비 1.5점의 성능 향상을 보였다.

  • PDF

An Experimental Study on the Engineering Properties of Deteriorated Concrete using Recycled Fine Aggregate by Fire Damage (재생잔골재를 활용한 화재피해를 입은 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Kwon, Yung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.190-196
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the Properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, This study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with making variable concrete test specimen, exposing high temperature environment, observing the explosive spalling and examining engineering property.

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

Experimental Study on the Characteristics of Ground Heat Exchange in Heating Greenhouses (난방 온실의 지중열 교환 특성에 관한 실험적 연구)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.218-223
    • /
    • 2016
  • The calculation method of ground heat exchange in greenhouses has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the soil temperature distribution and the soil heat flux in three plastic greenhouses of different size and location during the heating period. And then the calculation methods of ground heat exchange in greenhouses were reviewed. The soil temperature distributions measured in the heating greenhouse were compared with the indoor air temperature, the results showed that soil temperatures were higher than room temperature in the central part of greenhouse, and soil temperatures were lower than room temperature in the side edge of greenhouse. Therefore, it is determined that the ground heat gain in the central part of greenhouse and the perimeter heat loss in the side edge of greenhouse are occurred, there is a difference depending on the size of greenhouse. Introducing the concept of heat loss through the perimeter of building and modified to reflect the size of greenhouse, the calculation method of ground heat exchange in greenhouses is considered appropriate. It was confirmed that the floor heat loss measured by using soil heat flux sensors increased linearly in proportion to the temperature difference between indoor and outdoor. We derived the reference temperature difference which change the direction of ground heat flow and the perimeter heat loss factor from the measured heat flux results. In the heating design of domestic greenhouses, reference temperature differences are proposed to apply $12.5{\sim}15^{\circ}C$ in small greenhouses and around $10^{\circ}C$ in large greenhouses. Perimeter heat loss factors are proposed to apply $2.5{\sim}5.0W{\cdot}m^{-1}{\cdot}K^{-1}$ in small greenhouses and $7.5{\sim}10W{\cdot}m^{-1}{\cdot}K^{-1}$ in large greenhouses as design standard data.

Development of Carbon Dioxide Emission Factor from Resource Recovery Facility (폐기물자원회수시설의 이산화탄소 배출계수 개발)

  • Kim, Seungjin;Im, Gikyo;Yi, Chi-Yeong;Lee, Seehyung;Sa, Jae-Hwan;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.4 no.1
    • /
    • pp.51-61
    • /
    • 2013
  • To address the problems associated with climate change and energy shortage, Korea has been making efforts to turn waste materials into usable energy. Due to the ongoing efforts to convert waste materials into energy, waste incineration is expanding to utilize the heat generated, and the subsequent greenhouse gas emissions from these waste material incineration are expected to increase. In this study, a municipal waste incineration plant that generates heat and electricity through heat recovery was selected as a subject facility. Methods for estimating the greenhouse gas emissions in the municipal waste incineration plant that was selected as a subject plant were sought, and the greenhouse gas emissions and emission factor were estimated. The $CO_2$ concentrations in discharge gas from the subject facility were on average 6.99%, and the result from calculating this into greenhouse gas emissions showed that the total amount of emissions was $254.60ton\;CO_2/day$. The net emissions, excluding the amount of greenhouse gas emitted from biomass incineration, was shown to be $110.59ton\;CO_2/day$. In addition, after estimating the emissions by separating the heat and electricity generated in the incineration facility, greenhouse gas emission factors were calculated using the greenhouse gas emissions produced per each unit of output. The estimated emission factor for heat was found to be $0.047ton\;CO_2/GJ$ and the emission factor for electricity was found to be $0.652ton\;CO_2/MWh$. The estimated emission factor was shown to be about 17% lower than the $0.783ton\;CO_2/MWh$ emission factor for thermal power plants that use fossil fuels. Waste material types and fossil carbon contents were evaluated as being the factors that have major effects on the greenhouse gas emissions and emission factor.

Physicochemical Characteristics of Tailings from the Various Types of Mineral Deposits (광상유형에 따른 광물찌꺼기의 물리화학적 특성)

  • Lee, Pyeong-Koo;Youm, Seung-Jun;Jung, Myung-Chae;Lee, Jin-Soo;Kwon, Hyun-Ho
    • Economic and Environmental Geology
    • /
    • v.43 no.3
    • /
    • pp.235-248
    • /
    • 2010
  • To construct the standard methods for evaluation of physicochemical characteristics of tailings in Korea, specific gravity, paste pH, grain size, mineral compositions and heavy metal concentrations of total 26 tailings from 21 metallic mines were analyzed. Specific gravity of tailings ranged from 2.61 to 4.31 (avg. 3.04), and sand and silt grain were dominant in the tailings. Ranges of paste pH were 2.1-9.5 in tailings (7.1-9.2 at magmatic, skarn and hydrothermal replacement deposits and 2.1-9.5 at hydrothermal vein deposits). Additionally, hydrothermal vein deposits could be reclassified into three categories: (1) paste pH>7.0, (2) 4.0