• 제목/요약/키워드: 열환경 평가

Search Result 936, Processing Time 0.031 seconds

Availability Evaluation System for Remodeling of Existing Apartment Houses (기존 공동주택의 리모델링 용이성 평가 체계)

  • Cha, Woo-Cul;Lim, Byung-Wook;Shin, Chang-Hyun;Shin, Byung-Hyun;Lee, Jea-Sauk;Chun, Jae-Youl
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.5
    • /
    • pp.204-213
    • /
    • 2008
  • Apartments production without a previous example is existed by suddenly rapid growth of population and city. So this mass producted aged Apartments have many problems that is aged and staleness. Confrontation of obsolete and staleness is Build&Scrap and Remodeling. But Remodeling is much better than Build&Scrap Because Remodeling has Social, Economical, Environmental merits. This Research is Feasibility Evaluation System on an object of Remodeling. Feasibility Evaluation means Possibility on Objective action on aiming action in other words. It means degree of difficulty about purpose to act. Remodeling is based on existing apartment, to improve ability and performance of existed aged Apartment and by engineering technique and method. A point of view, development of Remodeling technique and popularization is necessary as well as Remodeling Plan and Construction technique of applied Existing building logical Approach is that. The purpose of this paper is handling allowance range of Remodeling Plan and Achievement accomplishment Feasibility Evaluation of purpose and objective and Understanding. Remodeling Feasibility is evaluated by two aspects. The first is Macro Level Approach of Remodeling Feasibility Evaluation on a Apartment Complex, and The second is Micro Level Approach of Remodeling Feasibility on each housing part is evaluated about removal and dismantlement.

Preliminary Evaluation of Domestic Applicability of Deep Borehole Disposal System (심부시추공 처분시스템의 국내적용 가능성 예비 평가)

  • Lee, Jongyoul;Lee, Minsoo;Choi, Heuijoo;Kim, Kyungsu;Cho, Dongkeun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.4
    • /
    • pp.491-505
    • /
    • 2018
  • As an alternative to deep geological disposal technology, which is considered as a reference concept, the domestic applicability of deep borehole disposal technology for high level radioactive waste, including spent fuel, has been preliminarily evaluated. Usually, the environment of deep borehole disposal, at a depth of 3 to 5 km, has more stable geological and geo-hydrological conditions. For this purpose, the characteristics of rock distribution in the domestic area were analyzed and drilling and investigation technologies for deep boreholes with large diameter were evaluated. Based on the results of these analyses, design criteria and requirements for the deep borehole disposal system were reviewed, and preliminary reference concept for a deep borehole disposal system, including disposal container and sealing system meeting the criteria and requirements, was developed. Subsequently, various performance assessments, including thermal stability analysis of the system and simulation of the disposal process, were performed in a 3D graphic disposal environment. With these analysis results, the preliminary evaluation of the domestic applicability of the deep borehole disposal system was performed from various points of view. In summary, due to disposal depth and simplicity, the deep borehole disposal system should bring many safety and economic benefits. However, to reduce uncertainty and to obtain the assent of the regulatory authority, an in-situ demonstration of this technology should be carried out. The current results can be used as input to establish a national high-level radioactive waste management policy. In addition, they may be provided as basic information necessary for stakeholders interested in deep borehole disposal technology.

The Characteristics of Black Carbon of Seoul (서울의 블랙카본 특성 연구)

  • Park, Jongsung;Song, Inho;Kim, Hyunwoong;Lim, Hyungbae;Park, Seungmyung;Shin, Suna;Shin, Hyejoung;Lee, Sangbo;Kim, Jeongho
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.2
    • /
    • pp.113-128
    • /
    • 2019
  • The concentration and coating thickness of black carbon (BC) were measured along with fine dust in the fall of 2018, at the Seoul Metropolitan Area Intensive Monitoring Station (SIMS). In fall, the concentration of $PM_{10}$ and $PM_{2.5}$ was $23{\pm}12.6{\mu}g/m^3$ and $12{\pm}5.8{\mu}g/m^3$, respectively, lower than that in other seasons. The BC level, measured using an Aethalometer, was $0.73{\pm}0.43{\mu}g/m^3$, while the levels of elemental carbon (EC) and refractory-BC (rBC), measured by semi-continuous carbon analyzer (SOCEC) and single particle soot photometer (SP2), were $0.34{\pm}0.18{\mu}g/m^3$ and $0.32{\pm}0.18{\mu}g/m^3$, respectively. As such, the concentration level differed according to the measurement method, but its time-series distribution and diurnal variation showed the same trends. The BC concentration at SIMS was primarily affected by automobiles with higher levels of BC during morning and evening commuting times due to increased traffic congestion. rBC, measured by SP2, had a peak concentration and coating thickness of 84 nm and 43 nm, respectively. Notably, the coating thickness had an inverse relationship with particle size.

Estimation of Indoor Environment using CFD of Multi-Purpose System with a Solar Collector -Part 1, focused on floor area and number of ventilation- (태양열온수기 적용 냉난방시스템의 CFD를 이용한 실내환경 평가 -제1보 바닥면적과 환기횟수를 중심으로-)

  • Kim, Jong-Ryeol;Choi, Kyang-Hyan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • This paper has been conducted to estimate cooling capacity of the dehumidification tower using hot water from a solar water heating system as a energy source of regeneration process when the dehumidification and drying system is applied to room cooling. A solar water heating system was operated and indoor temperature distributions were simulated according to weather conditions when the concerned solution was used to dehumidify room air in the dehumidification tower. Through this simulation researches we found th following results ; It was found that air velocity through supply and return diffusers should be controlled because it can cause uncomfort in dwelling area. It was found that in the sunny morning temperatures of dwelling area 1 and 2 are higher than those of dwelling area 3 and 4. In this research all the calculation results of heating and cooling system supported by solar water heater have confirmed that its cooling capacity could not reach PMV 0, thermal comfort.

An Investigation on Quantity of Unused Energy Using Temperature Difference Energy as Heat Source and Its Availability (온도차에너지를 열원으로 하는 미활용에너지의 부존량과 이용가능성에 관한 조사연구)

  • 박준택;장기창
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.106-113
    • /
    • 2002
  • While the demand for energy has shown a sharp increase recently, the supply seems to be limited by the fact that the conventional fossil fuel energy or nuclear energy has its own environmental problems such as, for example, global warming or nuclear waste disposal. To overcome such limited supply of energy, the utilization of natural thermal energy such as river water and sea water as well as treated sewage can be a substantial supplement. The potential use of the unused energy has become more and more feasible these days as the heat pump technology has been advanced. In the present study, the unused energy reserves are estimated on regional and monthly basis for each resource based on the method developed here in order to establish the base data for its utilization. The potential use of the unused energy is also discussed.

Development and Performance Evaluation for 1.6MW Gas Engine (1.6MW급 가스엔진의 개발 및 엔진성능평가)

  • Noh, Ki-Chol;Seol, Dong-Il;Hu, Kyoung-Me;Kim, Se-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.230-237
    • /
    • 2012
  • Engine makers are lately interested in the gas engine development as the alternative for diesel engine in order to cope the rise of oil price and the environmental regulation. So, STX has developed the 1.6MW gas engine which was converted from 22HLX diesel engine. The gas engine developed with precombustion chamber, which has good performance of 21bar BMEP at engine speed 1000rpm and low $NO_X$ emission of 50ppm at 15% oxygen composition, has been developed recently. Especially, it has a good thermal efficiency of 45% and a reduction efficiency of green house gas($CO_2$) emission of 25% than a conventional diesel engine.

Degradation Characteristics of Filament-Winding-Laminated Composites Under Accelerated Environmental Test (필라멘트 와인딩 복합적층재의 환경가속 노화시험 평가)

  • Kim, Duck-Jae;Yun, Young-Ju;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.295-303
    • /
    • 2007
  • Degradation behaviors of filament-winded composites have been evaluated under the accelerated environmental test of high temperature, water immersion and thermal impact conditions. Two kinds of laminated composites coated by an urethane resin have been used: carbon-fiber reinforced epoxy(T700/Epon-826, CFRP) and glass-fiber reinforced phenolic (E-glass/phenolic, GFRP). For tensile strength of $0^{\circ}$ composites, CFRP showed little degradation while GFRP did high reduction by 25% under the influence of high temperature and water However for water-immersed $90^{\circ}$ composites tensile strength of both CFRP and GFRP showed high reduction. Bending strength and modulus of $90^{\circ}$ composites were largely reduced in water-immersion as well as high temperature environment. Urethane coating on the composite surface improved the bending properties by 20%, however hardly showed such improvement for water-immersed $90^{\circ}$ composites. In case of shear strength and modulus, both CFRP and GFRP showed high reduction by water-Immersion test but did a slight increase by high temperature and thermal impact conditions.

Mobile Web Service Performance Enhancement by Simplifying Architecture (모바일 웹서비스 성능 향상 처리기 설계)

  • Oh, Soo-Lyul;Ryu, Gab-Sang;Kim, Chul
    • Journal of The Korean Association of Information Education
    • /
    • v.15 no.2
    • /
    • pp.287-294
    • /
    • 2011
  • In this paper, we suggest performance enhanced Mobile Web service architecture. Mobile Web Services are new technology that integrates different applications to provide interoperability. SOAP is a lightweight message exchanging protocol and is a principal factor that decides the Web Services performance. When a mobile Web Service is implemented with the Java technology, it should be implemented with both a SOAP message processor like AXIS, and Java Servlet container (e.g. Tomcat). This typical implementation is not efficient because it requires an additional communication port and process. In this paper, we suggest a new method that replaces this typical approach to enhance Web Service performance.

  • PDF

Mg-Zn-Mn 합금계에 Sn첨가에 따른 시효특성 연구

  • Jang, Gyeong-Su;Han, Jeong-Hwan;Lee, Byeong-Deok;Baek, Ui-Hyeon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.46.2-46.2
    • /
    • 2010
  • 최근 수송기기 및 전자부품산업에서의 성능향상 요구에 따라 경량고강도 비철금속재료의 수요가 증대되고 있다. 특히, 세계적으로 에너지 절약 및 환경 공해 규제가 대폭 강화됨에 따라 자동차, 항공기 등 수송기기의 소재경량화 소재로 낮은 밀도 기계적 가공성이 우수한 마그네슘 합금이 각광을 받고 있다. 그러나 Mg합금은 알루미늄 합금과는 달리 보호성 산화피막이 형성되지 않아 내식성 및 고온강도가 매우 취약하다. 이를 보안하기 위해서 본 연구에서는 마그네슘의 강도 개선을 위한 원소로써 고용강화 원소로 많이 쓰이는 Zn과 입자 미세화로 인한 항복강도를 증가시키는 Mn의 3원계 합금에 고온에서 안정한 Mg2Sn상이 형성되는 Sn을 첨가하여 시효처리에 따른 기계적 특성과 미세조직을 관찰하였다. 실험 이전에 Pandat Program에 의한 열역학적 분석을 바탕으로 Mg-Zn-Mn 및 Mg-Zn-Mn-Sn의 상태도 계산 및 MgZn와 Mg2Sn 석출분율을 예측하였다. 열역학 계산을 통해 도출된 석출온도를 통해 Mg-Zn-Mn 및 Mg-Zn-Mn-Sn 합금의 열처리에 따른 경도 및 미세구조를 관찰하였다. 또한, 기계적 특성을 평가하기 위해 상온 및 고온 인장시험을 실시하였고 XRD, SEM을 이용하여 석출상을 분석하였다.

  • PDF

A Study on Simplified Evaluation for Renewable Energy based Combination System in School - Considering the Size of Classroom and Capital Cost - (학교건물의 신·재생에너지기반 복합시스템 간이평가 기법 연구 - 학급규모와 투자비 중심으로 -)

  • Kim, Ji-Yeon
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.77-84
    • /
    • 2013
  • Schools are one of favorable public buildings for Renewable Energy(RE) systems due to site conditions and their energy demand profiles(e.g. daytime-based use of hot water and heating/cooling). Although the government encourages schools to be equipped with RE systems, the adoption of RE systems in existing energy supply systems faces technical and financial barriers. For example, when installing a RE-based combination system(RECS) to meet the energy demand at various school scales, identifying cost effective combination of capacities of the RECS is not trivial since it usually requires technically intensive work including detailed simulation and demand/supply analysis with extensive data. This kind of simulation-based approaches is hardly implementable in practice. To address this, a simpler and applicable decision-supporting method is suggested in this study. This paper presents a simplified model in support of decision-making for optimal capacities of RECS within given budget scales and schools sizes. The proposed model was derived from detailed simulation results and statistical data. Using this model, the optimal capacities of RECS can be induced from the number of classes in a school.