• Title/Summary/Keyword: 열환경 평가

Search Result 930, Processing Time 0.032 seconds

Evaluation of Combustion Mechanism of Droplet Cluster in Premixed Spray Flame by Simultaneous Time-Series Measurement (동시 시계열 계측에 의한 예혼합 분무화염 내 유적군 연소기구의 평가)

  • Hwang, Seung-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.442-448
    • /
    • 2009
  • To evaluate the combustion mechanism of each droplet cluster downstream of the premixed spray flame, the simultaneous time-series measurements were conducted by using optical measurement system consisting of laser tomography, multi-color integrated Cassegrain receiving optics (MICRO) and phase Doppler anemometer (PDA). Furthermore, the group combustion number of droplet cluster was estimated experimentally, and the combustion mechanism of droplet cluster was examined applying the theoretical analysis. The group combustion number, $G_c$, was experimentally estimated about all droplet cluster verified by planar images, and it was classified into the internal group combustion mode and the external group combustion mode according to the theoretical analysis. It is found that there are cases in which the group combustion number estimated experimentally for droplet cluster agree or disagree with the classification by theoretical analysis. The reason of disagreement is considered due to that the group combustion number was only estimated by the geometrical arrangement of droplets in cluster, and that the actual phenomenon is three-dimensional but the measurement system is two-dimensional.

Evaluation of experimental reliability for trace-quantity of gaseous VOC working standards based on thermal desorption analysis (극미량 휘발성유기화합물질의 기체상 표준시료 조제와 열탈착분석방식에 기초한 분석안정도의 평가)

  • Park, Shin-Young;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.553-558
    • /
    • 2006
  • In this study, an attempt was made to measure uncertainties involved in the VOC analysis for the VOC working standards prepared by a dilution technique using Tedlar bags. For this purpose, VOC standard gases of benzene, toluene, xylene, and styrene were prepared at four different concentrations (4, 8, 20, and 40 ppb). These standard samples were then loaded on to the GC system equipped with air server/thermal desorption (AS/TD) system. Each of these four standard concentrations was analyzed individually to derive their respective calibration results. These calibration data sets were then compared across four different compounds. According to this comparison, differences in calibration patterns were moderately insignificant within the selected concentration range of 4~40 ppb. It was also observed that the loss of styrene standard was fairly high compared to other VOCs investigated simultaneously. The results of our study suggest that the analytical uncertainty associated with the preparation of VOC starndard gas using a dilution technique can be assessed in a fairly reasonable manner for samples with a narrow concentration range.

Analysis of Environmental Impacts for the Biochar Production and Soil Application (폐목재를 이용한 바이오차 생산 및 토양적용의 환경평가)

  • Kim, Mihyung;Kim, Geonha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.461-468
    • /
    • 2014
  • Biochar is a carbon rich solid produced by the pyrolysis of biomass such as energy crops, forestry residues, and wood wastes. Biochar returned to soil is to mitigate climate change and the feedstock of wood wastes reduces fossil fuel consumption as well as disposal costs. This study was practiced to evaluate a biochar system by gasification in terms of global warming regarding the soil application of the produced biochar. Life cycle assessment methodology was used to analyze the environmental impacts of the system, and the functional unit was 1 tonne of wood wastes. The result shows that the biochar system by using wood wastes as feedstock produces 4.048E-01 $kgCO_2-eq$ from the pre-treatment process as chipping and drying, 4.579E-01 $kgCO_2-eq$ from the pyrolysis process, and 9.070E-02 $kgCO_2-eq$ from the spreading to agricultural land, therefore total 9.534E-01 $kgCO_2-eq$ are generated. About 252 kg of $CO_2$ is still stored in the produced biochar in soil after carbon offsetting of the system. Therefore, the net carbon of the system is -251 kg of $CO_2-eq$.

0.4 MW 급 분절형 아크 히터 플라즈마 풍동의 특성 평가

  • O, Pil-Yong;Choe, Jeong-Cheol;Choe, Seong-Man;Sin, Ui-Seop;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.222.1-222.1
    • /
    • 2016
  • 전북대학교 고온플라즈마응용센터에 구축된 0.4 MW 급 분절형 아크 가열 풍동은 초음속 비행과 우주 비행체의 지구 재진입 조건에서의 유사한 환경 모사가 가능하다. 극한상황에서의 고엔탈피 플라즈마 유동은 내열재료의 삭마 거동 연구와 고온재료의 성능평가에 중요한 역할을 수행 할 수 있다. 이러한 고엔탈피 초음속 플라즈마 유동장의 플라즈마 특성 평가 및 진단은 플라즈마와 내열재료의 상호작용 연구에 중요한 변수를 갖는다. 이를 위해 열유속 탐침, 쐐기 탐침, 고속 카메라 및 광분광기 등의 측정장비를 사용하여 열유속, 초음속 플라즈마의 속도, 플라즈마의 방전특성을 관찰하였다. 본 실험에서 사용된 분절형 아크 토치는 마하 3의 속도 유지하기 위해 토치 내부 압력 4 bar, 반응기 압력 40 mbar를 유지하였다. 토치에 공급되는 Ar(5%)+Air(95%)의 방전기체의 유량은 15 g/s 로 토치에 주입 되었다. 또한, 플라즈마 토치에 가해지는 입력전류는 200A ~ 350A로 10MJ/kg 이상의 엔탈피를 갖는 초음속 플라즈마 유동을 형성하였다.

  • PDF

Real Option Analysis for Medium-scale CHP Plant Investment with Volatile Electricity Prices (실물옵션을 이용한 소형열병합발전의 경제성 평가 : 전력가격 변동성을 고려하여)

  • Park, Hojeong;Jang, Chulho
    • Environmental and Resource Economics Review
    • /
    • v.16 no.4
    • /
    • pp.763-779
    • /
    • 2007
  • The combined heat-and-power (CHP) plant is recently suggested as an effective resolution in response to recent rising oil prices and the Kyoto Protocol. This research provides a model for economic appraisal to evaluate CHP investment. Real option model is developed to incorporate a case where the investment is irreversible and underlying revenue is stochastic. The analysis shows that power plant capacity more than 40 Gcal makes CHP investment profitable while the results may vary 10 modest level with respect to investment cost, heat sales price and discount rate.

  • PDF

Estimation of C(t) -Integral Under Transient Creep Conditions for a Cracked Pipe Subjected to Combined Mechanical and Thermal Loads Depending on Loading Conditions (열응력 및 기계응력이 작용하는 균열배관의 하중조건에 따른 천이 크리프 조건 C(t)-적분 평가)

  • Oh, Chang-Young;Song, Tae-Kwang;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.609-617
    • /
    • 2011
  • There is a trend towards the progressive use of higher operating temperatures and stresses to achieve improved efficiencies in power-generation equipment. It is important to perform the crack assessment under hightemperature and high-pressure conditions. The C(t)-integral is a key parameter in crack assessment for transient creep states. The estimation of the C(t)-integral is complex when considering the mechanical and thermal loads simultaneously. In this paper, we study estimation of C(t)-integral under combined mechanical and thermal load depending on loading conditions.

Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone (페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가)

  • Park Byung-Yoon;Ham Heung-Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

Performance Evaluation of OGS-FLAC Simulator for Coupled Thermal-Hydrological-Mechanical Analysis (열-수리-역학적 연계해석을 위한 OGS-FLAC 시뮬레이터의 성능 평가)

  • Park, Dohyun;Park, Chan-Hee
    • Tunnel and Underground Space
    • /
    • v.32 no.2
    • /
    • pp.144-159
    • /
    • 2022
  • The present study developed a sequential approach-based numerical simulator for modeling coupled thermal-hydrological-mechanical (THM) processes in the ground and investigated the computational performance of the coupling analysis algorithm. The present sequential approach linked the two different solvers: an open-source numerical code, OpenGeoSys for solving the thermal and hydrological processes in porous media and a commercial code, FLAC3D for solving the geomechanical response of the ground. A benchmark test of the developed simulator was carried out using a THM problem where an analytical solution is given. The benchmark problem involves the coupled behavior (variations in temperature, pore pressure, stress, and deformation with time) of a fully saturated porous medium which is subject to a point heat source. The results of the analytical solution and numerical simulation were compared and the validity of the numerical simulator was investigated.

Environmental flow evaluation considering river ecosystem's ecological habitat condition (하천 생태계의 서식조건을 고려한 환경유량의 정량적 평가)

  • Na, Jong-Moon;Cho, Yean-Wha;Park, Seo-Yeon;Lee, Joo-Heon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.144-144
    • /
    • 2020
  • 국내의 하천은 급격한 도시화 및 산업화로 인해 자연하천의 모습은 사라지고 이수와 치수 기능 위주의 하천관리가 이루어졌다. 하천은 치수기능을 강조하여 인공적으로 변화하였을 뿐만 아니라 하천생태환경 내에 서식하는 동식물의 서식 환경에도 교란을 야기하였다. 최근 하천관리의 패러다임이 변화함에 따라서, 하천이 갖는 자연적 특성을 회복하는 환경적 측면을 강조한 생태하천 복원사업에 대한 관심이 높아지고 있으나, 수생생물 서식지 복원과 생태계에 필요한 환경유량에 관한 정량적인 평가를 위한 연구는 부족한 실정이다. 본 연구는 경상북도 김천시와 구미시를 관류하여 낙동강으로 합류되는 감천을 대상으로 하였으며, 댐 건설로 인한 하천 생태계 변화 및 하천유량에 대한 통계적 분석, 수리 모델링, 하천구역의 공간적 분석을 진행하였다. 통계적 분석을 위한 시계열 자료 구축은 감천 하류에 있는 선산관측소의 2002년 ~ 2019년까지 수위, 유량을 사용하였으며, 김천부항댐이 건설 된 2014년 1월 1일을 기점으로 댐 건설 전(2002 ~ 2013)과 댐 건설 후(2014 ~ 2019)로 구분하였다. HEC-EFM(Ecosystem Function Model)을 활용하여 어류를 포함한 수생생물의 성공적인 서식을 위한 환경유량을 산정하였다. 산정된 환경유량을 HEC-GeoRAS(Geographic River Analysis System)와 HEC-GeoEFM(Geographic Ecosystem Function Model)을 적용·연계하여 수생식생 도입이 가능한 하천 구간과 어류 산란 및 성장에 적합한 하천구간을 표현하였으며, 댐 건설 전후의 서식지 면적을 계산하여 수생생물의 성공적인 서식환경이 조성되었는지 확인하였다. 본 연구를 바탕으로 수생생물의 하천 서식지 개선을 위한 명확한 환경유량을 수립하는 데 도움이 될 것으로 판단된다.

  • PDF

Development of stream low flow routing algorithm using a grid-based continuous hydrological model considering dam and weir operation data (댐·보 방류량 자료를 활용한 분포형 수문모형 기반 하천 갈수량 추적 알고리즘 개발)

  • Lee, Yong Gwan;Jung, Chung Gil;Kim, Won Jin;Kim, Seong Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.29-29
    • /
    • 2019
  • 급격한 도시화와 기후변화로 인한 자연적인 물순환 구조의 변화는 기존 수자원 이용 경향을 변화시키며 하천건천화 현상을 유발하고 있다. 이를 관리하기 위해 하천건천화 평가 및 예측이 가능한 영향 평가 기술이 필요하며, 국내에서는 GIS 기반의 분포형 수문 모형인 Drying Stream Assessment Tool and Water Flow Tracking (DrySAT-WFT)이 개발되어 활용되고 있다. 그러나 격자기반의 물수지 모형은 단위 cell 안의 수직적인 물의 거동은 파악하기 용이하나, 모형의 특성상 저수지, 댐, 보와 같은 수리 시설물의 방류량에 따른 하도의 흐름 추적에는 어려움이 있다. 본 연구의 목적은 DrySAT-WFT 모형에 댐?보 방류량 자료와 연계한 하도추적 알고리즘을 개발하여 모형의 유출 모의 성능을 개선하고, 1976년부터 2015년까지의 유출 모의를 통해 전국 표준유역을 대상으로 각 유역에 대한 하천건천화 원인 추적 및 평가를 수행하고자 한다. 하천건천화영향요소를 고려하기 위한 모형의 입력 자료로 산림높이, 도로망, 지하수 이용량, 토지이용, 토심, 기상 변화에 대해 1976년부터 2015년까지 구축한 시계열 전국 자료를 활용하였으며, 일별 강우량, 상대습도, 평균풍속, 평균 및 최고, 최저 기온, 일조시간의 기상자료를 구축하였다. 개선된 DrySAT-WFT 유출 모의 결과는 선행 연구와의 비교를 통해 모의 개선점을 정량적으로 제시하고자 한다.

  • PDF