• Title/Summary/Keyword: 열화상측정

Search Result 230, Processing Time 0.027 seconds

A Study on Measuring the Temperature and Revising the Result When Measuring the Temperature of NPP Pipes Using Infrared Thermography (적외선 열화상 기술을 이용한 원자력 배관의 온도측정과 보정에 관한 연구)

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Pack, Chan-Joo;Kim, Dong-Soo;Jung, Duk-Woon;Chang, Ho-Sub
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.421-426
    • /
    • 2009
  • The emissivity is different because the emitted angle changes according to the position of the infrared thermography camera and object. Because of this, the temperature distribution expressed when measuring the temperature by using the infrared thermography system is not the accuracy temperature. Although the real surface temperature is constant, the temperature measured by using infrared thermography camera have error in accordance with the value of emissivity. In this paper, the temperatures of the round cylindrical object and the flat square object that heated to the equal temperature were measured by infrared thermography camera. The emissivity calibration formula and correction table are made with the affect of the view angle and emission angle form the surface temperature value. The error of measured temperature values are corrected by using the emissivity calibration formula and correction table, and apply to defect detection of the nuclear power plant pipe. From the calibration method, reliability surface temperature values were obtained.

Method for Measuring Weld Temperature Using an Infrared Thermal Imaging Camera (적외선 열화상 카메라를 이용한 용접부의 온도 측정 방법)

  • Ro, Chan-Seung;Kim, Kyeong-Suk;Chang, Ho-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.299-304
    • /
    • 2014
  • In this paper, a method is tested to measure temperatures in high-temperature welds. Protective glass was installed between an infrared thermal imaging camera and a heat source, and temperature compensation was applied to the measuring instruments. When the temperature of halogen lamps was taken in real-time and measured by the thermal camera, the temperature was found to be almost invariant with the distance between the camera and heat source. The temperature range could be predicted, through correlations with the thickness of the protective glass and the measured distance. This study suggests that the temperature measurement of welds obtained by using an infrared thermal imaging camera is valid, through experimental testing of heat sources.

Visibility of the Thermal Infrared Camera under Non-Visibility Environments (비가시 환경에서의 적외선 열화상 카메라의 가시도)

  • Cho, Jai Wan;Baik, Seong Hoon;Choi, Young Soo;Jeong, Kyung Min
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1315-1316
    • /
    • 2015
  • 본 논문에서는 원자력발전소 중대 사고를 모사한 비가시 환경에서 적외선 열화상카메라의 관측성능 (가시도)을 정량적으로 평가하고자 하였다. 이를 위해 세계기상기구의 가시도 정의를 이용하여 가시도를 측정하였으며, 측정된 가시도 조건에서 적외선 열화상카메라의 관측성능을 평가하였다.

  • PDF

A Study on the Design and Implementation of a Thermal Imaging Temperature Screening System for Monitoring the Risk of Infectious Diseases in Enclosed Indoor Spaces (밀폐공간 내 감염병 위험도 모니터링을 위한 열화상 온도 스크리닝 시스템 설계 및 구현에 대한 연구)

  • Jae-Young, Jung;You-Jin, Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2023
  • Respiratory infections such as COVID-19 mainly occur within enclosed spaces. The presence or absence of abnormal symptoms of respiratory infectious diseases is judged through initial symptoms such as fever, cough, sneezing and difficulty breathing, and constant monitoring of these early symptoms is required. In this paper, image matching correction was performed for the RGB camera module and the thermal imaging camera module, and the temperature of the thermal imaging camera module for the measurement environment was calibrated using a blackbody. To detection the target recommended by the standard, a deep learning-based object recognition algorithm and the inner canthus recognition model were developed, and the model accuracy was derived by applying a dataset of 100 experimenters. Also, the error according to the measured distance was corrected through the object distance measurement using the Lidar module and the linear regression correction module. To measure the performance of the proposed model, an experimental environment consisting of a motor stage, an infrared thermography temperature screening system and a blackbody was established, and the error accuracy within 0.28℃ was shown as a result of temperature measurement according to a variable distance between 1m and 3.5 m.

Measurements of Temperature Distribution on Human Body Surface using Multi-Channel Skin Temperature Sensors (다채널 피부온 센서를 이용한 인체표면 온도분포의 측정)

  • 한화택;김민규;박명규;이성수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.205-209
    • /
    • 2002
  • 인체의 피부온도는 쾌적성과 감성에 크게 영향을 미치며 의류의 개발이나 건축환경의 설계 등에 활용되고 있다. 단순히 몇몇 측정점에서의 피부온도 데이터가 아니라 인체표면에 걸친 온도분포를 파악함으로써 다양한 정보를 이용하여 보다 광범위한 응용분야에 활용될 수 있을 것이다. 현재 인체표면의 온도분포를 측정하기 위하여 대부분 적외선 열화상 카메라를 활용하고 있다 그러나 열화상 카메라는 서미스터 등을 이용한 피부온 센서에 비하여 온도분해능이 떨어지며 특히 의복내의 피부온을 측정하는 것이 불가능하고 노출된 인체표면에 대해서만 측정이 가능하다. 따라서 본 연구에서는 피부온 센서를 이용한 인체표면 온도분포 측정시스템을 개발하기 위하여 각 센서의 위치와 간격, 그리고 인체 곡면을 따라서 보간법에 따라 온도분포 결과에 미치는 영향을 파악하고 적외선 화상 결과와 비교하고자 한다.

  • PDF

Personalized Cooling Management System with Thermal Imaging Camera (열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.782-785
    • /
    • 2021
  • In this paper, we propose a personalized cooling management system with thermal imaging camera. The proposed equipment uses a thermal imaging camera to control the amount of cold air and the system according to the difference between the user's skin temperature before and after the procedure. When the skin temperature is abnormally low, the cold air supply is cut off to prevent the possibility of a safety accident. It is economical by replacing the skin temperature sensor with a thermal imaging camera temperature measurement, and it can be visualized because the temperature can be checked with the thermal image. In addition, the proposed equipment improves the sensitivity of the sensor that measures the distance to the skin by calculating the focal length by using a dual laser pointer for the safety of a personalized cooling management system to which a thermal imaging camera is applied. In order to evaluate the performance of the proposed equipment, it was tested in an externally accredited testing institute. The first measured temperature range was -100℃~-160℃, indicating a wider temperature range than -150~-160℃(cryo generation/USA), which is the highest level currently used in the field. In addition, the error was measured to be ±3.2%~±3.5%, which showed better results than ±5%(CRYOTOP/China), which is the highest level currently used in the field. The second measured distance accuracy was measured as below ±4.0%, which was superior to ±5%(CRYOTOP/China), which is the highest level currently used in the field. Third, the nitrogen consumption was confirmed to be less than 0.15 L/min at the maximum, which was superior to the highest level of 6 L/min(POLAR BEAR/USA) currently used in the field. Therefore, it was determined that the performance of the personalized cooling management system applied with the thermal imaging camera proposed in this paper was excellent.

Performance analysis of the satellite range measurement using tone method in the presence of noise (Tone 방식을 사용한 위성 거리 측정 방법에 대한 잡음의 영향)

  • 김영완;김호겸장대익
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.163-166
    • /
    • 1998
  • Toen 방식을 사용하는 거리 측정시스템의 잡음 및 간섭에 대한 열화 도를 분석한다. 위성 링크상의 잡음 및 다중 변조 방식에 의한 전송 신호간 간섭들로 인하여 위상차 측정에 열호가 발생하며, 열화 도는 ranging 측정 시스템의 잡음 대역폭에 의존한다. Ranging 측정 모드에서는 잡음 대역폭 8Hz, 4Hz 그리고 1Hz에 대하여 0.3dB 열화가 방샐하였으며, ranging 및 원격 측정 데이터 전송 모드에서는 대역폭에 따라 6.4dB, 4.2dB, 4dB가 발생하였다.

  • PDF

The Utilization of Nondestructive Testing and Defects Diagnosis using Infrared Thermography (적외선 열화상을 이용한 비파괴시험 활용 및 결함 진단)

  • Choi, Man-Yong;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.525-531
    • /
    • 2004
  • In this paper, the concept of infrared thermography(IRT), the principle of measurement of IRT and how to set up the IR camera for the nondestructive testing are described in detail. Also, its utilization and non-destructive testing(NDT) diagnosis are reviewed. By performing the periodic non-touched WDT through the estimation of thermal patterns related with the temperature for the surface targeted, IRT can be applied to the early prevention of the device failure. For the diagnosis utilization, thermal imaging patterns obtained from IRT for heated blocks with internal defects were estimated through the lion-destructive method and discussed the way of IRT estimation from the analysis of characteristics between material defects and thermal imaging patterns.

Corrosion Measurement Method Using Thermographical Information (열화상 정보를 이용한 부식률 예측기법)

  • Yun, Ju-Young;Chung, Lan;Roh, Young-Sook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.142-147
    • /
    • 2007
  • In order to measure corrosion level of steel reinforcement rebar which is inside reinforced concrete structure, infrared thermographic technique was employed. Experimental test parameters were four different ambient temperatures and various levels of corrosion states (0, 1, 3, 5, 7 and 10% of weight loss). After analysis of temperature distributions of concrete surface, the amount of heat flux from the concrete surface is directly proportional to the corrosion level which is inside of concrete.

Measurement Uncertainty on Subsurface Defects Detection Using Active Infrared Thermographic Technique (능동 적외선열화상 기법을 이용한 이면결함 검출에서의 측정 불확도)

  • Chung, Yoonjae;Kim, Wontae;Choi, Wonjae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.341-348
    • /
    • 2015
  • Active infrared thermography methods have been known to possess good fault detection capabilities for the detection of defects in materials compared to the conventional passive thermal infrared imaging techniques. However, the reliability of the technique has been under scrutiny. This paper proposes the lock-in thermography technique for the detection and estimation of artificial subsurface defect size and depth with uncertainty measurement.