• Title/Summary/Keyword: 열화상이미지

Search Result 7, Processing Time 0.018 seconds

A Basic Study to Reveal the Relationships between Solar Thermal Radiation and Thermographic Images (태양 복사와 열화상이미지의 관계에 대한 기초 연구)

  • Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.10 no.1
    • /
    • pp.13-17
    • /
    • 2020
  • Among the factors that must be taken into account when using thermal imaging cameras that are expanding their application to various fields, a basic study was conducted focusing on temperature on the effect of solar radiation on the photographed thermal image. Through all experiments, in order to use an image taken with a thermal imaging camera for an object installed or located outdoors, a separate temperature correction according to the size of solar radiation or a separate device to block the effect of solar radiation must be additionally installed. Since the temperature of the same object may vary in the thermal image taken indoors or outdoors, it is necessary to calibrate it through comparison with other temperatures as a reference point. In the case of measuring the temperature of a glossy surface such as metal indoors with a thermal imaging camera, it was confirmed that an environment that can remove the light reflection effect by the glossy surface must be constructed and photographed.

An Experimental Study on the Application of LIBS for the Diagnosis of Concrete Deterioration (콘크리트 열화 진단의 LIBS 적용을 위한 실험적 연구)

  • Woo, Sang-Kyun;Chu, In-Yeop;Youn, Byong-Don
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.140-146
    • /
    • 2017
  • It is laser induced breakdown spectroscopy(LIBS) that enables qualitative and quantitative analysis of the elements contained in unknown specimen by comparing the wavelength characteristics of each element obtained from the spectral analysis of the standard specimen with the wavelength analysis results from unknown specimens. In this study, the applicability of LIBS to the analysis of major deterioration factors affecting concrete durability was experimentally analyzed. That is, the possibility of applying LIBS to the diagnosis of concrete deterioration by studying the quantitative detection of harmful deteriorating factors on chloride, sulfate and carbonated mortar specimens using LIBS was studied. As a result of LIBS test for each chloride and sulfate specimen, the LIBS spectral wavelength intensity of chlorine and sulfur ions increased linearly with increasing concentration. Carbon ion LIBS spectral wave intensities of carbonated specimens increased nonlinearly over the duration of carbonation exposure. From the above results, it can be partially confirmed that LIBS can be applied to the diagnosis of concrete deterioration. In case of concrete carbonation, it is presumed that carbon content is contained in the cement itself and is different from the detection of chloride and sulfate specimen. Therefore, it is considered that more various parameter studies should be performed to apply LIBS to concrete carbonation.

Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring (Multi-measuring기법을 이용한 원전 제어밸브의 누설진단)

  • Kim, Sung-Young;Kim, Young-Bum;Kim, Bong-Ho;Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

A Study on Heat Transfer Characteristics of Impinging Jet about Distance Ratio leer Thermal Control (전열제어를 위한 충돌제트의 거리비에 따른 열전달특성에 관한 연구)

  • 김동균;김정환;배석태;김시범;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1237-1243
    • /
    • 2001
  • This paper presents an information about the heat transfer characteristics of impinging jet in eletronic equipment with infrared image processing unit. There have been many experimental investigations and theoretical studies on impinging jet because of application in a wide variety of industrial process including electronic equipment. In this study, we used infrared image processing unit to visualize heat transfer characteristics of impinging jet in eletronic equipment. Infrared image processing unit is one of non-contact temperature measuring methods and it is possible to minimize flow resistance and this measurement is comparatively accurate. The main parameters are distance between nozz1e and heat source. Reynolds number is 6000.

  • PDF

Evaluation of Improvement of Detection Capability of Infrared Thermography Tests for Wall-Thinning Defects in Piping Components by Applying Lock-in Mode (적외선열화상 시험에서 위상잠금모드 적용에 따른 배관 감육결함 검출능력 개선 평가)

  • Kim, Jin Weon;Yun, Kyung Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1175-1182
    • /
    • 2013
  • The lock-in mode infrared thermography (IRT) technique has been developed to improve the detection capability of defects in materials with high thermal conductivity, and it has been shown to provide better detection capability than conventional active IRT. Therefore, to investigate the application of this technique to nuclear piping components, lock-in mode IRT tests were conducted on pipe specimens containing simulated wall-thinning defects. Phase images of the wall-thinning defects were obtained from the tests, and they were compared with thermal images obtained from conventional active IRT tests. It showed that the ability to size the detected wall-thinning defects in piping components was improved by using lock-in mode IRT. The improvement was especially apparent when detecting short and narrow defects and defects with slanted edges. However, the detection capability for shallow wall-thinning defects did not improve much when using lock-in mode IRT.

Class 1·3 Vehicle Classification Using Deep Learning and Thermal Image (열화상 카메라를 활용한 딥러닝 기반의 1·3종 차량 분류)

  • Jung, Yoo Seok;Jung, Do Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.96-106
    • /
    • 2020
  • To solve the limitation of traffic monitoring that occur from embedded sensor such as loop and piezo sensors, the thermal imaging camera was installed on the roadside. As the length of Class 1(passenger car) is getting longer, it is becoming difficult to classify from Class 3(2-axle truck) by using an embedded sensor. The collected images were labeled to generate training data. A total of 17,536 vehicle images (640x480 pixels) training data were produced. CNN (Convolutional Neural Network) was used to achieve vehicle classification based on thermal image. Based on the limited data volume and quality, a classification accuracy of 97.7% was achieved. It shows the possibility of traffic monitoring system based on AI. If more learning data is collected in the future, 12-class classification will be possible. Also, AI-based traffic monitoring will be able to classify not only 12-class, but also new various class such as eco-friendly vehicles, vehicle in violation, motorcycles, etc. Which can be used as statistical data for national policy, research, and industry.

Variation of facial temperature to 3D visual fatigue evoked (3D 시각피로 유발에 따른 안면 온도 변화)

  • Hwang, Sung Teac;Park, SangIn;Won, Myoung Ju;Whang, MinCheol
    • Science of Emotion and Sensibility
    • /
    • v.16 no.4
    • /
    • pp.509-516
    • /
    • 2013
  • As the visual fatigue induced by 3D visual stimulation has raised some safety concerns in the industry, this study aims to quantify the visual fatigue through the means of measuring the facial temperature changes. Facial temperature was measured for one minute before and after watching a visual stimulus. Whether the visual fatigue has occurred was measured through subjective evaluations and high cognitive tasks. The difference in the changes that occurred after watching a 2D stimulus and a 3D stimulus was computed in order to associate the facial temperature changes and the visual fatigue induced by watching 3D contents. The results showed significant differences in the subjective evaluations and in the high cognitive tasks. Also, the ERP latency increased after watching 3D stimuli. There were significant differences in the maximum value of the temperature at the forehead and at the tip of the nose. A previous study showed that 3D visual fatigue activates the sympathetic nervous system. Activation of the sympathetic nervous system is known to increase the heart rate as well as the blood flow into the face through the carotid arteries system. When watching 2D or 3D stimuli, the sympathetic nervous system activation dictates the blood flow, which then influences the facial temperature. This study is meaningful in that it is one of the first investigations that looks into the possibility to measure 3D visual fatigue with thermal images.