• Title/Summary/Keyword: 열탈착분석

Search Result 34, Processing Time 0.024 seconds

Remediation of Petroleum-Contaminated Soil by a Directly-Heated Thermal Desorption Process (직접 가열식 열탈착 공정을 이용한 유류오염토양의 정화)

  • Min, Hyeong-Sik;Yang, In-Ho;Jeon, Sang-Jo;Kim, Han-S.
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.62-70
    • /
    • 2009
  • A field soil highly contaminated with petroleum hydrocarbons (JP-8 and diesel fuels) was employed for its remediation by a lab-scale thermal desorption process. The soil was collected in the vicinity of an underground storage tank in a closed military base and its contamination level was as high as 4,476 ppm as total petroleum hydrocarbon (TPH). A lab scale directly-heated low temperature thermal desorption (LTTD) system of 10-L capacity was developed and operated for the thermal treatment of TPH contaminated soils in this study. The desired operation temperature was found to be approximately $200-300^{\circ}C$ from the thermal gravimetric analysis of the contaminated field soils. The removal efficiencies higher than 90% were achieved by the LTTD treatment at $200^{\circ}C$ for 10 min as well as at $300^{\circ}C$ for 5 min. As the water content in the soils increased and therefore they were likely to be present as lumps, the removal efficiency noticeably decreased, indicating that a pre-treatment such as field drying should be required. The analysis of physical and chemical properties of soils before and after the LTTD treatment demonstrated that no significant changes occurred during the thermal treatment, supporting no needs for additional post-treatments for the soils treated by LTTD. The results presented in this study are expected to provide useful information for the field application and verification of LTTD for the highly contaminated geo-environment.

Thermal Effusion of Implanted Inert Gas Ions from Si(100) (Si(100)에 주입된 불활성 기체 이온들의 방출 특성)

  • Jo Sam K.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.73-80
    • /
    • 2006
  • Thermally-driven effusion of inert gases out from Si(100), into which energetic $\~l keV\;He^+,\;Ne^+,\;A^r+,\;and\;Kr^+ ions$ had been implanted at a moderate substrate temperatures of $\~400 K$, was investigated by means of temperature-programmed desorption (TPD) mass spectrometry. While He effused out broadly over $500\~1,100 K$, Ne, Ar, and Kr effusion occurred sharply at 810, 860, and 875 K, respectively. Hydrogen adsorption/desorption analysis for the ion-treated Si(100) surfaces indicated minimal to severe damage by ions with increasing mass from He to Kr. Implications of these results in light of literature reports are discussed.

Analysis of Volatile Organic Compounds by GC/MS with the Thermal Desorber and Characterization of the Major Components Attributing to Malodor -An Analytical Example of the Odor Emitted from the Compost of Food Waste- (흡착 열탈착 장치와 GC/MS를 이용한 휘발성 유기화합물의 분석과 악취원인 성분의 예측 - 음식물 퇴비화 과정에서 발생되는 악취분석의 예 -)

  • Yu, Mee-Seon;Yang, Sung-Bong;Ahn, Jeong-Soo
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.80-86
    • /
    • 2002
  • The simultaneous analysis of the odorous compounds designated by law in Korea and Japan was examined with the thermal desorber gas chromatography-mass spectrometry using one column. The approximate concentrations of trimethyl amine, acetaldehyde, methyl mercaptan and dimethyl sulfide were estimated. Styrene, dimethyl disulfide, propionaldehyde, n-butyl aldehyde, i-butyl aldehyde, n-valeraldehyde, i-valeraldehyde, ethyl acetate, toluene, xylene, methyl i-butyl ketone and i-butanol were detected at concentrations of the detection limits of their threshold values. As a typical example of simultaneous analysis of the odorous compounds, the volatile organic compounds emitted from compost procedure of food waste were concentrated and analyzed with thermal desorber/GC/MSD, and major malodorous compounds were estimated from the concentrations and threshold values of the detected components. From the result of analysis, 34 compounds were confirmed and among them, trimethyl amine, i-valeraldehyde, methyl mercaptan, methyl allyl sulfide, dimethyl sulfide, acetaldehyde, ethanol, n-butyaldehyde were expected to attribute to the odor in order of strength.

Examination of GC-TD sensitivity for reduced sulfur compounds in relation to temporal stability and reproducibility (환원 황화합물의 열탈착 분석기법에 대한 감도의 경시변화 및 재현성에 대한 연구)

  • Hong, One-Feel;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.24-35
    • /
    • 2010
  • To learn more about the calibration properties of reduced sulfur compounds (RSCs) by the combination of gas chromatography(GC)-pulsed flame photometric detector (PFPD) and thermal desorption method, a series of calibration experiments were conducted on the basis of both internal and external calibration approaches. For these experiments, gaseous standards of 4 RSCs ($H_2S$, $CH_3SH$, DMS, and DMDS) were prepared at two different concentration levels of both low (10, 20, 50,and 100 ppb) and high ranges (100, 200, 500, and 1000 ppb) along with $CS_2$ as an internal standard. First, the external calibration results were compared between fixed standard volume (FSV) and fixed standard concentration (FSC) method. Secondly, FSV-based calibration results were compared between external and internal calibration results. As FSV method suffers from sensitivity variations less significantly than FSC, the former is recommended to maintain the consistency in GC-TD sensitivity for RSC analysis. In addition, when the calibration data were examined in terms of RSE between external and internal calibration data, the results were not consistent enough to show improvements in internal method. Hence, diverse efforts are desirable to optimize the reproducibility in terms of GC-TD sensitivity for RSC analysis.

A development of continuous and on-site measurement of VOCs in ambient air using a novel thermal desorption technique. (열탈착 방법을 이용한 휘발성유기화합물 자동 연속 분석 장치의 개발)

  • 송희남;김종환;김조천;한진석;신진호;이강웅
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.367-368
    • /
    • 2001
  • 휘발성 유기화합물질들(VOCs)은 그 자체가 인체에 유해한 화합물로 작용할 뿐만 아니라 환경대기 중에서 질소화합물(NOx)과 광화학 반응을 통하여 오존 등 유해한 산화물을 형성하는 전구물질로 작용하여 이들의 거동을 이해하고 분석하는 것이 대기환경에 매우 중요한 것으로 인식되고 있다. 더욱이 오존 예보 및 경계 체제의 중요한 입력 요인으로 인식되어 신뢰성 있는 배출 정보의 산출을 위해 VOCs 농도를 현장 실측하여 분석하고 예보에 이용하려는 시도가 이루어지고 있다. (중략)

  • PDF

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Analysis of Volatile Compounds in Cacao by TD GC/MS (TD GC/MS를 이용한 카카오의 향기 성분 분석)

  • Jung, jin-soun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.267-268
    • /
    • 2015
  • 카카오에 함유되어 있는 향기성분을 열탈착 가스크로마토 질량분석기(TD GC/MS)를 이용하여 실시하였다. 그 결과 hydrocarbone류 10종, alcohol류 3종, aldehyde류 7종, ketone류 3종 및 carboxylic acid류 4종 등 총 27종의 향기성분이 동정되었다. 그 중에서 carboxylic acid류의 향기성분이 55.88%로 가장 많이 함유되어 있었다. 그 다음으로 알데히드류가 13.80%, 케톤 화합물이 11.90% 그리고 모노테르펜 화합물이 11.7% 함유되어 있음을 확인하였다.

  • PDF