• Title/Summary/Keyword: 열전효과

Search Result 679, Processing Time 0.03 seconds

Target Advertisement Service using a Viewer's Profile Reasoning (시청자 프로파일 추론 기법을 이용한 표적 광고 서비스)

  • Kim Munjo;Im Jeongyeon;Kang Sanggil;Kim Munchrul;Kang Kyungok
    • Journal of Broadcast Engineering
    • /
    • v.10 no.1 s.26
    • /
    • pp.43-56
    • /
    • 2005
  • In the existing broadcasting environment, it is not easy to serve the bi-directional service between a broadcasting server and a TV audience. In the uni-directional broadcasting environments, almost TV programs are scheduled depending on the viewers' popular watching time, and the advertisement contents in these TV programs are mainly arranged by the popularity and the ages of the audience. The audiences make an effort to sort and select their favorite programs. However, the advertisement programs which support the TV program the audience want are not served to the appropriate audiences efficiently. This randomly provided advertisement contents can occur to the audiences' indifference and avoidance. In this paper, we propose the target advertisement service for the appropriate distribution of the advertisement contents. The proposed target advertisement service estimates the audience's profile without any issuing the private information and provides the target-advertised contents by using his/her estimated profile. For the experimental results, we used the real audiences' TV usage history such as the ages, fonder and time of the programs from AC Neilson Korea. And we show the accuracy of the proposed target advertisement service algorithm. NDS (Normalized Distance Sum) and the Vector correlation method, and implementation of our target advertisement service system.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

Analysis of Building Energy Reduction Effect based on the Green Wall Planting Foundation Type Using a Simulation Program (건물일체형 패널형 벽면녹화 식재기반 유형별 건물에너지 성능 분석)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Yoon, Yong-Han
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.6
    • /
    • pp.936-946
    • /
    • 2015
  • This study is aimed to analyze the reduction performance of building energy consumption according to planting base types of panel-type green walls which can be applied to existing buildings. The performance was compared to the general performance of green walls that have demonstrated effects of improving the thermal environment and reducing building energy consumption in urban areas. The number of planting base types was 4 in total, and simulations were conducted to analyze the thermal conductivity, thermal transmittance, and overall building energy consumption rate of each planting base type. The highest thermal conductivity by the planting base type was Case C (0.053W/mK), followed by Case B (0.1W/mK) and Case D (0.17W/mK). According to the results of energy simulation, the most significant reduction of cooling peak load per unit area was Case C (1.19%), followed by Case B (1.14%) and Case D (1.01%) when compared to Case A to which green wall was not applied; and the most significant reduction of heating peak load per unit area was estimated to be Case C (2.38%), followed by Case B (1.82%) and case D (1.50%) when compared to Case A. The amount of yearly cooling and heating energy use per unit area showed 3.04~3.22% of reduction rate. The amount of the 1st energy use showed 5,844 kWh/yr of decrease on average for other types when compared to Case A. The amount of yearly $CO_2$ emission showed 996kg of decrease on average when compared to Case A to which the green wall was not applied. According to the results of energy performance evaluation by planting location, the most efficient energy performance was eastward followed by westward, southward and northward. According to the results of energy performance evaluation by planting location by green wall ratio, it was found that as the ratio of green wall increased, the energy performance displayed better results, showing approx. double reduction rate in energy consumption at 100% of green wall ratio than the reduction rate at 20% to 80% of green wall ratio.

Advanced Aluminum Welding Technologies for Productivity Improvement (생산성 향상을 위한 신개념 알루미늄 용접 방법)

  • Cho, Yong-Joon;Lee, So-Young;Chang, In-Sung;Do, Sung-Sup
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.19-19
    • /
    • 2009
  • 최근, 유한한 에너지 자원의 한계와 지구 온난화 등으로 세계의 제조 산업은 새로운 국면을 맞이하고 있으며, 특히, 자동차 산업은 화석연료를 주 에너지원으로 사용한다는 점과 이 연료를 연소시킬 때 발생하는 이산화탄소가 지구 온난화의 주된 원인이 될 수 있다는 점에서 상기 문제들을 해결하기 위한 다양한 방법에 주목하고 있다. 그 중에서 자동차의 생산기술 측면에서 볼 때, 가장 중요한 이슈는 차체 경량화다. 자동차 차체는 자동차를 구성하고 있는 여러 가지 부품 중에서 약 40% 정도의 무게 비율을 차지하고 있기 때문에, 차체 경량화는 연비향상과 이산화탄소 배출가스 감소와 직접적인 관계를 가지고 있다. 다양한 차체 경량화 방법 중에서 가장 쉽게 접근할 수 있는 방법이 경량소재 적용에 의한 경량화 방법이다. 현재, 탄소섬유 강화 플라스틱과 같이 무게 절감 비율을 최대화 할 수 있는 소재들도 개발되어 일부 적용되고 있지만, 일반적으로 차체 경량화 소재로 가장 널리 사용되고 있는 소재는 알루미늄 합금이며, 이에 대한 차체 적용 비율이 점차로 높아지는 추세에 있다. 이에, 본 연구에서는 알루미늄 합금이 차체에 적용되었을 때의 장단점을 살펴보고, 알루미늄 합금을 적용한 차체 생산과정에서 유의해야 될 사항들과 이를 바탕으로 하는 생산성 극대화 방안에 대하여 고찰하였다. 먼저, 기존의 알루미늄 저항 점 용접공법의 단점을 최소화하고 대량생산 체계에 적합하도록 개발된 새로운 개념의 저항 점 용접 시스템에 대해 그 성능과 양산성을 검증하였다. 구리 전극과 알루미늄 피용접물 사이에 프로세스 테이프를 삽입하여 용접하는 이 시스템은 열전도성이 큰 알루미늄 용접부에서 저전류의 조건에서도 효과적으로 균일한 발열현상이 발생하게 하였으며, 전극 팁 드레싱 없이 모든 용접점이 항상 동일한 조건에서 용접이 이루어질 수 있도록 하였다. 용접 조건 설정에 있어서도 용접전류가 통전되는 순간에 전극 가압력을 자유로이 변형시켜 용접부 크랙 발생을 최소화할 수 있음을 확인하였다. 알루미늄의 또 다른 대표적인 접합방법인 아크용접에 있어서는 용접 입열량을 조절하여 용접변형을 최소화 할 수 있는 아크용접 시스템에 대해 양산성과 적용 타당성을 검토하였다. 와이어 송급 방향을 자유자재로 바꿀 수 있는 이 시스템의 특성에 의해 스패터를 최소화하면서 용융금속이 효과적으로 모재에 금속이행 될 수 있음을 확인하였으며, 판재, 압출재, 및 다이캐스팅재 등 다양한 차체 소재에 대한 용접 가능성 및 미그-레이저 하이브리드 용접과의 비교분석을 통하여 차체 박판 용접에서도 최소의 열변형으로 효과적으로 사용될 수 있음을 보였다.

  • PDF

Measurement of Thermal Diffusivity and the Optical Properties of a Carbon Nanotube Dispersion by Using the Thermal Lens Effect (열렌즈 효과를 이용한 탄소 나노 튜브 분산액의 열확산도와 광학적 특성 측정)

  • Park, Hyunwoo;Kim, Hyunki;Kim, Sok Won;Lee, Joohyun
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1167-1172
    • /
    • 2018
  • Carbon nanotubes (CNTs) are structures of carbon atoms bonded together in hexagonal honeycomb shapes, with multi-walled CNTs having a very high thermal conductivity of $3000W/m{\cdot}K$ and single-walled CNTs having a conductivity of $6000W/m{\cdot}K$. In this work, the transmittance and the thermal diffusivity of a multi-walled carbon nanotube dispersion with a concentration of 1.5 M were measured using a single beam method, a dual beam method, and the thermal lens effect. The nonlinear optical coefficients were obtained by using the z-scan method, which moved the sample in the direction of propagation of the single laser beam, propagation and the thermal diffusivity was measured using a double laser beam. As a pump beam, a diode-pumped solid state (DPSS) laser with a wavelength of 532 nm and an intensity of 100 mW was used. As the probe beam, a He-Ne laser having a wavelength of 633 nm and an intensity of 5 mW was used. The experimental result shows that when the concentrations of the sample were 9.99, 11.10, 16.65, and 19.98 mM, the nonlinear absorption coefficients were 0.046, 0.051, 0.136 and 0.169 m/W, respectively. Also, the nonlinear refractive indices were 0.20, 0.51, 1.25 and $1.32{\times}10^{-11}m^2/W$, respectively, and the average thermal diffusivity was $1.33{\times}10^{-6}m^2/s$.

Experimental Study on Local Mass Transfer Characteristics of Flat Plate Using Tripping Wire (트리핑 와이어를 사용한 평판에서의 국소물질전달 특성에 관한 실험적 연구)

  • Yoo, Seong-Yeon;Cho, Woong-Sun;Jo, Woo-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.285-292
    • /
    • 2013
  • The purpose of this research is to investigate how the boundary layer separation caused by a tripping wire installed in front of the flat plate affects the transition from laminar to turbulent flow, and consequently mass transfer. A naphthalene sublimation technique is used to measure the local mass transfer coefficients on the flat plate, and two boundary conditions for the developed and developing flow are considered to evaluate the effects of the flow boundary. The local mass transfer data for a flat plate with a tripping wire are compared with the data for a flat plate without a tripping wire. The variation trends of the local heat transfer coefficients for the plates with and without the tripping wire are similar to each other in the case of the developing flow, but are quite different for the developed flow. The average Sherwood number for the flat plate with a tripping wire is much higher than that without a tripping wire because of the boundary layer separation.

Accelerated Life Testing and Validity Evaluation of Finger Strips Used for Electromagnetic Shielding Doors (전자파 차폐 도어용 핑거 스트립의 가속수명시험 및 유효성 평가)

  • Lee, Joo Hong;Kim, Do Sik;Chang, Mu Seong;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.831-837
    • /
    • 2015
  • Many persons and electronic devices are exposed to electromagnetic (EM) waves generated from magnetic resonance imaging (MRI) equipment, EM pulses (EMPs), and many other kinds of EM wave devices. Finger strips are used to provide shielding from these EM waves. Because of the high thermal conductivity of finger strips, they are used in the design of specialized doors that are installed in shielded rooms. In this study, we perform an accelerated life test using the load acceleration stress, which affects the main failure mode of finger strips. We predict the life of the finger strip under normal usage conditions based on the results of the accelerated life test. We compare the results with those predicted from the life test under normal usage conditions to evaluate the validity of accelerated life testing.

Study of On-chip Liquid Cooling in Relation to Micro-channel Design (마이크로 채널 디자인에 따른 온 칩 액체 냉각 연구)

  • Won, Yonghyun;Kim, Sungdong;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.31-36
    • /
    • 2015
  • The demand for multi-functionality, high density, high performance, and miniaturization of IC devices has caused the technology paradigm shift for electronic packaging. So, thermal management of new packaged chips becomes a bottleneck for the performance of next generation devices. Among various thermal solutions such as heat sink, heat spreader, TIM, thermoelectric cooler, etc. on-chip liquid cooling module was investigated in this study. Micro-channel was fabricated on Si wafer using a deep reactive ion etching, and 3 different micro-channel designs (straight MC, serpentine MC, zigzag MC) were formed to evalute the effectiveness of liquid cooling. At the heating temperature of $200^{\circ}C$ and coolant flow rate of 150ml/min, straight MC showed the high temperature differential of ${\sim}44^{\circ}C$ after liquid cooling. The shape of liquid flowing through micro-channel was observed by fluorescence microscope, and the temperarue differential of liquid cooling module was measuremd by IR microscope.

Properties and Mock-up Test of Lightweight Foamed Concrete Based on Blast Furnace Slag by Crack Reducing Admixture (팽창성 균열저감제를 이용한 고로슬래그 미분말 기반 경량기포 콘크리트의 특성 및 목업실험)

  • Han, Sang-Yoon;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.6
    • /
    • pp.507-515
    • /
    • 2017
  • This study is to develop a high quality lightweight foamed concrete that can be applied in the field using EXFG by cracking reducing agent combined with FGD and ALS. First, to increase the volume of foam, the flow and density of the mixture was increased and decreased, respectively. At this time, the effect of substitution ratio of EXFG on fluidity was negligible. The fraction of foam was the highest at EXFG 1%, and the settlement was found to be prevented by the expansion reaction at EXFG 1%. At this time, the ratio of foam was 65%. In the compressive strength, the strengths were similar or decreased when the substitution ratio of EXFG was more than 1%. The apparent density satisfied the KS 0.5 type at the bubble contents was 65%. In case of EXFG substitution, dry shrinkage was decreased by about 10%. As the substitution ratio of EXFG increased, the thermal conductivity increased proportionally.

Effect of Rib Arrangement on Heat Transfer in the Divergent Channel (확대 채널에서 리브 배열이 열전달에 미치는 효과)

  • Lee, Myung-Sung;Lee, Gyeong-Ju;Kim, Sang-Moon;Min, Se-Chan;Bae, Jae-Moon;Hwang, Jun-Su;Park, Cheol-O;Kim, Dong-Chan;Jung, Jung-Hyeon;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.35-40
    • /
    • 2017
  • The effects of the different rib geometries such as V-shaped continuous (case A), parallel broken (case B), and V-shaped broken (case C) ribs on the heat transfer and pressure drops in a divergent channel with $45^{\circ}$ inclined ribs on one wall or two walls are checked out. The top and bottom walls are adiabatic; two side walls are uniformly heated in the divergent rectangular channel. The tested Reynolds numbers are ranged from 22,000 to 75,000. The channel with two opposite walls inclined only has the length of test section of 1 m and the channel divergence ratio of $D_{ho}/D_{hi}=1.49$, corresponding to $1.43^{\circ}$ inclined walls. The results show in the identical pumping power that the V-shaped continuous rib (case A) with two ribbed walls is the greatest, but the parallel broken rib (case B) with one ribbed wall is the worst in the thermal performance.