• 제목/요약/키워드: 열전효과

검색결과 679건 처리시간 0.024초

The Numerical Analysis and Experimental Verification of the Heat Transfer Effect on the Highly Pressurized Gas Spring (고압 밀폐 가스 스프링에서의 열전달 효과 수치해석 및 실험적 검증)

  • Han, Insik;Choi, Kyojun;Kim, Jaeyong;Lee, Yoonbok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제21권2호
    • /
    • pp.87-97
    • /
    • 2013
  • Recently the use of gas spring in the combat and commercial vehicle's suspension is increasing. Because of its nonlinear characteristics, the gas spring can support wide range of dynamic loads and gives good ride quality. In design of gas spring, isothermal and adiabatic processes are applied generally, but those processes could not produce heat transfer effect in the simulation. So in this study, heat transfer differential equation and BWR/Ideal state equation are used to calculate the pressure of gas spring which is changing with time. The numerical analysis showed that the pressure of gas spring forms a hysteresis loop in the both of the state equations. But the peak pressure value of BWR equation over 0.1Hz frequency are higher than that of adiabatic process. And the test results showed that the differences between test results and ideal gas equation are smaller than those of BWR equation, so the ideal equation is more accurate than BWR equation in this case.

An investigation on heat transfer effects of two dimensional plane jet attaching offseted obliqued wall (단이 진 경사벽면에 부착되는 2차원 평면제트의 열전달 효과에 관한 연구)

  • Yun, Sun-Hyeon;Lee, Dae-Hui;Sim, Jae-Gyeong;Song, Heung-Bok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제21권10호
    • /
    • pp.1314-1325
    • /
    • 1997
  • Experiments have been conducted to determine the flow and heat transfer characteristics for a two-dimensional turbulent wall attaching offset jet at different oblique angles to a flat surface. The distributions of the wall static pressure coefficient and time-averaged reattachment position for various offset ratios and oblique angles have been measured. The local Nusselt number distributions on the plate surface were also measured using liquid crystal as a temperature indicator. The new hue-capturing technique utilizing a true color image processing system was used to accurately determine the temperature of the liquid crystal. The experiments were carried out at Reynolds number, Re (based on D) of from 7300 to 21,300 with offset ratio, H/D from 2.5 to 10, and oblique angle, .alpha. from 0 deg. to 400 deg..

A study on an experimental basis a special character of insulating oil the use of a transformers (변압기용 절연유의 특성에 관한 실험적 연구)

  • Kim, Sung-Dae;Park, Il-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제12권11호
    • /
    • pp.5188-5193
    • /
    • 2011
  • This research is for temperature control of insulating oil inside the transformer. After I designed and manufactured various systems using Peltier element, which was thermal element, and Heat pipe, which was a cooling system, without electric power. The optimum system could be made by applying them to the temperature control for the insulating oil. I could verify that the combination type of Heat pipe 100 W+ Peltier 100W has a more outstanding capacity than pure Heat pipe 300 W within 60 degrees Celsius through experiments. Through this, I verify that the method of a proper design is prominent, and make an attempt at contribution to power saving effect and more effective control of Distributing board by using this combination type.

Augmentation of Heat Transfer by two Dimensional Impinging Air Jet (Effect of Square Rib Width) (2차원(次元) 충돌분류(衝突噴流)의 열전달(熱傳達) 증진(增進)에 관(關)한 실험적(實驗的) 연구(硏究) (사각(四角) Rib폭(幅)의 효과(效果)))

  • Lee, Y.H.;Rhee, K.S.;Seo, J.Y.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • 제17권4호
    • /
    • pp.350-356
    • /
    • 1988
  • The impinging air jet system is still being used in the various fields with its inherent merits, that is, the easiness in engineering application and high heat transfer coefficients at stagnation point. The purpose of this study is augmentation of heat transfer without additional power in the rectangular air jet which impinges vertically to the heating surface. As a method of passive heat transfer augmentation in a two-Dimensional impinging jet, the transverse-repeated surface roughness of square cross-section is used. This paper deals with the experimental study on the characteristics of heat transfer at the x-direction in between nozzle exit and heating surface of flat plate, and that of ribbed plate. And this study also investigates the effect of square rib widths. The integral average heat transfer coefficient of ribbed plate is about 2.2 times larger than that of flat plate.

  • PDF

Heat transfer and flow characteristics of sweeping jet issued from rectangular nozzle with thin plate (박판이 부착된 사각노즐에서 분사되는 Sweeping jet의 유동 및 열전달 특성)

  • Kim, Donguk;Jung, Jae Hoon;Seo, Hyunduk;Kim, Hyun Dong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • 제17권2호
    • /
    • pp.58-66
    • /
    • 2019
  • This study investigated heat transfer and flow characteristics of a sweeping jet issued from a rectangular nozzle with a thin plate. A thin vertical aluminum plate was attached on outlet of fluidic oscillator to increase velocity of central area with Coanda effect and enhance heat transfer performance. From visualization and PIV experiments, sweeping jet with a thin plate has larger velocity distribution in center region than that of the normal sweeping jet while oscillating frequency is similar as the normal one. Thermographic phosphor thermometry method was used to visualize the temperature field and Nu distribution of plate with impinging sweeping jet with thin plate. Four Reynolds numbers and three jet-to-wall distances were selected as parameters. It is found that heat transfer performance in the low jet-to-wall spacing was enhanced as the cooled area was expanded. However, when the jet-to-wall spacing became greater than 8dh, heat transfer performance became similar due to reduced impinging velocity.

An Experimental Study on Absorber with Spiral Tube in Absorption Heat Pump (흡수열펌프에서 나선형 관이 설치된 흡수기의 실험적 연구)

  • Min, Byong-Hun
    • Applied Chemistry for Engineering
    • /
    • 제21권1호
    • /
    • pp.71-75
    • /
    • 2010
  • The efficient performance of absorber is of great importance for the absorption heat pump cycle. The experimental study of absorber with spiral tube of tangential feeding of liquid phase has been investigated using methanol-glycerine as a working fluid. The effect of change in absorber operating conditions was analyzed to improve the performance. The increase in solution flow rate and cooling flow rate positively affects the absorber performance while an increse in the solution concentration negatively affects the absorber performance. The results showed that mass absorption flux was in the range of $0.2{\sim}0.6kgm^{-2}sec^{-1}$, the solution heat transfer coefficient between 1.6 and $4.2kwm^{-2}K^{-1}$, the absorber thermal load from 0.9 to 1.5kw and the mass transfer coefficient from 0.9 to 1.7 m/sec.

Combustion Characteristics of Landfill Gas in Constant Volume Combustion Chamber for Large Displacement Volume Engine (II) - Combustion Analysis - (대형기관 모사 정적연소실에서 매립지 가스의 연소특성에 대한 연구 (II) - 연소 분석 -)

  • Kwon, Soon Tae;Park, Chanjun;Ohm, Inyong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제37권8호
    • /
    • pp.743-752
    • /
    • 2013
  • This is the second paper on the combustion characteristics of landfill gas in a constant volume combustion chamber for a large displacement volume commercial engine, and it discusses the combustion process on the basis of pressure measurements. The results show that the bimodal peak pressure phenomenon, which is caused by the interaction of the heat release and the heat transfer, is more apparent as the mixtures are more favorable to combustion, and the magnitudes of the pressures depend on the unburned fraction. In addition, there exist four main inflection points during heat release owing to variations in the heat transfer area related to flame propagation from the ignition point. Furthermore, the number of inflection points increases as the mixture quality worsens because of the extended burn duration. Consequently, the sophisticated interactions between the heat transfer area changing pattern due to flame propagation and transfer duration might cause very peculiar heat release patterns.

Impact of Design Parameters on Length and Application Effect of Surface Water Heat Exchanger(SWHE) (지표수 열교환기의 용량과 적용 효과에 대한 설계 인자의 영향)

  • Sohn, Byonghu;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • 제4권1호
    • /
    • pp.49-56
    • /
    • 2016
  • Commercial buildings are generally cooling-dominated and therefore reject more heat to a vertical ground heat exchanger(GHE) than they extract over the annual cycle. Shallow ponds can provide a cost-effective means to balance the thermal loads to the ground and to reduce the length of GHE. The objective of this work has been to develop a design tool for surface water heat exchanger(SWHE) submerged in shallow pond. This paper presents the analysis results of the impact of design parameters on the length of SWHE and its application effect on geothermal heat pump(GHP) system using vertical GHE. In order to analysis, We applied ${\epsilon}-NTU$ method on designing the length of SWHE. Analysis results show that the required pipe length of SWHE was decreased with the increase of approach temperature difference and with the decrease of pipe wall thickness. In addition, when the SWHE was applied to the GHP system, the temperature of vertical GHE was more stable than that of standalone GHE system.

신문용지의 소프트 닙 캘린더링

  • Lee, Hak-Rae;Lee, Sa-Yong;Ryu, Hun;Jeon, Dae-Gu;Kim, Chang-Hui
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 한국펄프종이공학회 1999년도 춘계학술발표논문집
    • /
    • pp.44-44
    • /
    • 1999
  • 전적으로 해외기술에 의존하고 있는 소프트 닙 캘린더 피복의 국산화를 위해 시험 제작 된 소프트 닙 캘린더용 연질롤의 캘린더링 효과를 구명하기 위해서 공정 변수에 따른 신문 용지의 물성변화를 평가하였다. 연질 롤로는 (주)광성고무롤에서 시험제작된 경도 90 Shore D의 것을 사용하였으며, 캘린 더링 시의 압력, 가열 롤의 표면온도, 닙 체류 시간, 유입지의 함수율 변화에 따른 신문용지 의 별크, 평활도, 광택도, 인장강도, 인열강도, 불투명도 변화를 조사하였다. 별크는 캘린더링 시 압력, 가열 롤의 표면온도, 닙 체류시간의 증가에 따라 감소하였다. 가열 롤의 표면온도가 높을수록 별크가 크게 감소되었으며, 닙 체류시간이 짧은 경우에는 1 120 226;C 이하에서 캘린더링을 실시하는 것이 별크 유지에 효과적이었다. 평활도는 가열 롤의 표연 온도, 닙 체류시간이 증가함에 따라 개선되었으며, 선압과 함 수율 증가에 의해서도 상승되는 경향을 보였. 인장강도는 유입지의 함수율, 닙 체류시간, 가열 롤의 표면온도가 모두 상승할 경우 증 가하는 결과를 나타내었다. 이는 함수율 증가에 의해 섬유의 유연성이 향상된 상태에서는 칼렌더링 온도와 닙체류 시간 증가에 의한 섬유의 기계적 변형과 열전달에 의한 섬유의 열 변형이 효과적으로 발생하여 섬유간 결합면적이 증가된 결과로 생각되었다. 인열강도는 소프트닙 캘린더링 후 전반적으로 감소하였으나 캘린더링 온도와 닙체류시 간은 인열강도에 미치는 영향은 적은 것으로 나타났다. 소프트 닙 캘린더링 시 발생하는 인 열강도의 저하를 막기 위해서는 닙 체류시간을 짧게 적용하고 섬유의 열변형이 종이의 표변 에서만 일어날 수 있도록 유입지 함수율과 가열롤의 표면온도를 적절히 조절하는 것이 필요 하리라 판단되었다.광택도는 온도와 압력이 증가할수록 증가하였으나, 닙 체류시간에 따라서는 큰 변화를 나타내지 않았으며 120도씨에서는 닙 체류시간의 증가에 따라 광택도가 오히려 감소하기도 하였다. 불투명도는 벌크와 마찬가지로 압력이 높고 가열롤의 표면온도가 높은 경우 낮게 나타 났다 특히 닙 체류시간의 증가에 따라 감소하는 경향을 보였다.보였다.

  • PDF

Effect of Fire Fighters' Turnout Gear Materials Air Gap on Thermal Protective Performance (소방보호복 소재의 공기간극이 열보호 성능에 미치는 영향)

  • Lee, Jun-Kyoung;Kwon, Jung-Suk
    • Fire Science and Engineering
    • /
    • 제28권4호
    • /
    • pp.97-103
    • /
    • 2014
  • To ensure adequate protection from the risk of burns, fire fighter's turnout has a composite of more than three components and air gaps between layers of materials. During the flame exposure, radiation and convection heat transfer occurs in the air gap, thus the air gap acts as a thermal resistance with non-linear characteristics. Therefore, in this study, the experiments were performed to identify the effect of various air gap width (0~7 mm) on the thermal protective performance of fire fighter's clothing. The temperatures on each layer and RPP (Radiant Protective Performance, the most effective index representing the thermal protective performance) were measured with various incident radiant heat fluxes. The temperature at the rear surface of the garment decreased and RPP increased with increasing air gap width because the thermal resistance increased. Especially, it could be found that RPP value and air gap width has almost linear relation for the constant incident heat flux conditions. Thus relatively simple RPP predictive equation was suggested for various incident heat flux and air gap conditions.