Heat Transfer Characteristics with Changing Distances between Burner and Heat Exchanger (버너와 열교환기 간격 변화에 대한 열전달 특성)

  • Kim, Jong-Min;Lee, Jae-Park;Yu, Byeong-Hun;Kum, Sung-Min;Lee, Chang-Eon;Lee, Seung-Ro
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.933-938
    • /
    • 2011
  • In this study, the heat transfer characteristics and NOx and CO emissions of a heat exchanger were investigated using a premixed burner. The experiments involved changing the distance between the burner and heat exchanger to 30, 40, and 50 mm with various equivalence ratios. The results showed that the NOx and CO emissions increased as the equivalence ratio was increased because the flame temperature increased, regardless of the distance between the burner and heat exchanger. In particular, the CO emission increased significantly as the distance between the burner and heat exchanger was decreased. The optimal equivalence ratio for the A-type heat exchanger (distance between the burner and heat exchanger: 30 cm) was 0.7 in the experimental range. In this case, the CO and NOx emissions were 94.5 ppm and 11.2 ppm, respectively, and the efficiency was 84.1%.

A Study on Heat Transfer Coefficient of a Perflourocarbon Heat Pipe (Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구)

  • 강환국;김철주;이진성;김재진
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.05a
    • /
    • pp.95-103
    • /
    • 1998
  • 오늘날 전기 철도 차량의 속도제어방식에는 A.C모터의 속도를 제어하는 방식을 많이 사용하고 있고 이 경우 여러 개의 GTO thyristor와 다이오드가 필요하다. 그런데 이러한 반도체 소자들은 전기 부하의 일부를 저항열로 소모하며 반도체의 용량에 따라 차이가 있으나 전기 철도 차량의 경우 약 1~2㎾의 열이 발생한다. 따라서 이들 소자들이 적정온도범위(100~12$0^{\circ}C$미만)를 유지하기 위해서는 소자의 내부저항열을 외부로 방출시켜야 한다. 지난 30여 년 동안 이러한 반도체 소자 냉각에는 강제대류, 침적 비등, 히트파이프식 냉각방법이 적용되어 왔다. 최근에는 히트파이프식 냉각방법이 유지보수, 크기 및 중량 등 여러 측면에서 상대적으로 유리하기 때문에 히트파이프식 냉각방법을 주로 사용하고 있다. (중략)

  • PDF

The study on heat transfer enhancement using indirect cooling system in the channel with heat source (간접냉각방식을 이용한 열원이 부착된 채널내의 열전달 촉진에 관한 연구)

  • 김광추;박만흥;윤준규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.321-331
    • /
    • 1999
  • A numerical study is carried out for increasing heat removal using indirect cooling system. Computation is performed for nine cases as variation of flow condition in the lower channel. As the result of this study, water is more effective than air at the same pressure loss in spite of the lower inlet velocity. In channel configuration, the vertical channel is more effective than horizontal channel because of the buoyancy effect. Under the condition that heat generation is the same, counter flow effectively decreases the temperature difference among blocks. Parallel flow is more effective than counter flow when average temperature of all blocks is considered. In the case of installing obstacles in the lower channel, it is desirable to install obstacles in the bottom of lower channel. Heat transfer rate increases as the height of obstacles increases.

  • PDF

The measurement equipment for 915MHz 30kW class magnetron test (915MHz 30kW 마그네트론 시험을 위한 측정 장비)

  • Cho, Kook-Hee;Jeon, Seok-Gy;Jung, Sun-Shin;Lee, Hong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1570-1571
    • /
    • 2006
  • 산업용 가열, 건조, 해동 기술 분야에서 피 가열물의 열전달 특성이 좋지 않은 경우 대출력 마그네트론을 적용하여 전자파 가열방식을 이용함으로써 기존의 가열방식 보다 효율을 상당히 개선할 수 있음은 오래 전부터 알려져 왔다. 그러나 국내에서는 대출력(30kW급 이상) 마그네트론 제조기술 및 성능분석을 할 수 없어 외국에서 수입하여 산업에 산발적으로 적용하고 있는 실정이다. 따라서 본 연구는 30 kW급 대출력 마그네트론과 구동전원을 위한 시험 장비를 구축하여 신뢰성을 확보하면 마그네트론을 이용한 고효율 가열, 건조, 해동 기술에 적용이 가능하다.

  • PDF

KSTAR 중성입자빔 입사장치의 크라이오 배기계통 설계 개념

  • 인상렬;박미영;오병훈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.36-36
    • /
    • 2000
  • KSTAR 토카막은 보조가열 장치로 2005년까지 1대(최종적으로는 2대)의 중성입자빔 입사장치(NBI)를 설치하여 장치의 기본 설계값에 도달할 예정이다. KSTAR NBI는 3개의 이온원을 가지고 있으며 총 수소 유입량은 70 Torr.L/s인 반면 고속 중성 입자빔량은 모두 11 Torr.L/s로 기체 배기량은 59 Torr.L/s에 달하고 압력은 장소에 따라 10-5~10-6 Torr로 유지되며 총배기속도가 1~2$\times$106 L인 펌프가 필요하다. 이때 크라이오 펌프(cryopump) 방식이 거의 유일한 해결책이라고 할 수 있다. 크라이오 펌프는 고속 입자빔 수송로의 양편에 각각 설치되는데 총면적 30m2 내외의 극저온 냉각판(cryo-pnael)들과 이를 상온 열복사로부터 보호하기 위한 열차폐(thermal shield) 및 흡기구 배플(baffle), 그리고 적절한 냉각장치로 구성된다. 시운전 단계에서는 15K GM 냉동기와 활성탄이 부착된 냉각판을 사용하는 방식과 4K GM 냉동기로 냉각하는 방식이, 최종 운전단계에서는 3.7K 액체 헬륨을 사용하는 방식이 고려되고 있다. 크라이오 펌프의 구조설계에 앞서 우선 배기속도, 흡?량, 작동압력, 냉각판 온도, 열손실량 등 설계사양을 확정하고 정리하는 일이 진행되고 있다. 또 냉각방식과 상관없이 동일한 개념으로 만들어지는 배플과 열차폐의 최적설계를 위한 몬테카를로 계산과 열전도 계산을 병행하고 있다. 이 곳에서는 KSTAR NBI 장치의 주배기계로서 사용될 크라이오 펌프의 설계방향과 전반적인 구조 및 예상성능 등에 대해 발표하려고 한다.

  • PDF

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

원적외선 곡물건조기 개발

  • 김유호;조영길;조광환;이선호;김영민;한충수;금동혁;한종규
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.173.2-174
    • /
    • 2003
  • 국내 보급되고 있는 곡물건조기는 열풍형 순환식 곡물건조기가 주종을 이루고 있는데, 이건조기의 경우 곡물이 순환하면서 열풍공급과 템퍼링과정을 반복하면서 건조가 이루어지는 대류열전달 방식을 채택하고 있다. 대류열전달 방식은 복사열전달 방식에 비해 열전달률이 낮기 때문에 건조속도와 열효율이 떨어지며, 건조시 미질 향상과 건조비용 절감에 한계가 있어 왔다. 따라서 건조에너지의 절감과 동시에 고품질 쌀 생산을 할 수 있는 새로운 형식의 곡물건조기술을 확립하고자 원적외선 곡물건조기를 개발하였다. 원적외선은 0.56~l,000$\mu\textrm{m}$의 전자파로서 세라믹 도료표면에 열을 가하면 원적외선 파장대의 강한 에너지를 얻을 수 있다. 이같은 원적외선 에너지를 농산물에 조사시키면 열이 침투하게되고 동시에 농산물의 내부온도가 상승함에 따라 활발한 분자운동을 하면서 수분을 표면으로 이동시키기 때문에 열풍건조방법에 비해 열전달효율이 높고, 농산물을 보다 균일하게 건조가 가능하므로 좋은 품질의 쌀을 생산할 수 있는 특징을 가지고 있다. 시작기는 1회 3,800kg을 건조할 수 있도록 설계하였고, 템퍼링실, 건조실, 열풍실, 승강기 등으로 구성되었다. 원적외선 방사체의 형태는 실린더형이고, 방사체가 설치된 열풍실 위쪽은 타공망, 아래쪽은 방사량을 높이기 위하여 일부 개방된 구조로 제작하였다. 본 연구에서 구명된 원적외선 방사체 길이와 조사거리는 각각 1,470mm, 125mm가 적절한 것으로 나타났다. 시작기의 성능시험을 열풍건조기(대비구)와 비교한 결과 소음은 대비구에서의 94.12dB보다 13% 가량 낮게 나타났고, 건조온도를 45$^{\circ}C$로 설정하고 벼를 건조했을 때 건감률 0.58%,wb로 대비구의 0.47%,wb 보다 23% 높았고, 건조소요에너지도 470kcal/kg - water로 2%의 절감되었다. 또한 건조한 벼를 도정하여 색, 냄새, 윤기, 찰기 등에 대한 관능검사결과는 원적외선 건조방법이 종합기호도가 6.37으로 열풍건조방법 6.13보다 우수한 평가를 받았다. 건조비용은 시작기의 구입가격이 20% 비싸기 때문에 시간당 고정비가 높았으나, 건조성능이 우수하여 건조비용이 69,350원/톤으로 대비구보다 14% 절감되는 것으로 나타났다.

  • PDF

Effects of Cooking Methods with Different Heat Intensities on Antioxidant Activity and Physicochemical Properties of Garlic (열처리 조리방법이 마늘의 항산화 활성과 이화학적 특성에 미치는 영향)

  • Jo, Hyeri;Surh, Jeonghee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.12
    • /
    • pp.1784-1791
    • /
    • 2016
  • Garlic was subjected to eight different cooking methods (raw, boiling, steaming, microwave cooking, deep-frying, oven-roasting, pan-frying, and pan-roasting) utilized for typical Korean cuisine. Garlic was analyzed for antioxidant activities and physicochemical properties to elucidate effects of cooking. Garlic cooked at higher temperatures showed significantly lower lightness and higher yellowness (P<0.001). In particular, deep-frying and pan-frying resulted in lowest lightness and soluble solid content, indicating that non-enzymatic browning reactions were more facilitated. Compared with raw garlic, all cooked garlic tended to have lower thiosulfinates, presumably due to decomposition into polysulfides and/or leaching into cooking water and oil. Microwave cooking retained organic acids, total reducing capacity, and flavonoids, which can be attributed to low microwave intensity and shorter cooking time under which heat-labile bioactive components might have undergone less decomposition. Cooking significantly increased metal-chelating activity (P<0.001). In addition, oven-roasting and pan-roasting enhanced total reducing capacity and flavonoid content, indicating that thermal treatments increased the extractability of bioactive components from garlic. However, boiling, deep-frying, and pan-frying, in which garlic is in contact directly with a hot cooking medium, reduced antioxidant activities. Deep-frying resulted in largest reduction in DPPH radical scavenging activity of garlic, which correlated well with reduction of total reducing capacity and flavonoid content. The results show that the antioxidant activity of garlic could be affected by cooking method, particularly heat intensity and/or direct contact of the cooking medium.

Assessment and Improvement of the Horizontal In-Tube Condensation Heat Transfer Model in the MARS code (MARS 코드의 수평관내부 응축열전달 모델 평가 및 개선)

  • Lee, Hyun Jin;Ahn, Tae Hwan;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.56-68
    • /
    • 2016
  • Extensive researches have been carried out for enhancing the safety of nuclear power plants and, especially, the development of passive cooling systems, such as passive containment cooling system (PCCS) and passive residual heat removal system, is increasingly important, where condensation is a crucial heat transfer mechanism. Recently, Ahn & Yun et al. developed a horizontal in-tube condensation heat transfer model as one of the activities for the PCCS development. In this work, we implemented the Ahn & Yun 's condensation heat transfer model into the MARS code and assessed it using the PASCAL experimental data. Based on the results of the assessment, we identified the limitations of the Ahn & Yun 's model and suggested a modified Ahn & Yun 's model, and assessed the model using various experimental data.

Study for Effect of Changes in Thermal Properties on Cooling Process in Running Hot Steel Strip After Hot Rolling (열간압연 이후 주행하는 고온 강재의 냉각해석에서 소재의 물성변화 효과 연구)

  • Park, Il Seouk;Park, Jung Eun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.459-465
    • /
    • 2013
  • In the manufacturing process of steel plates, materials at high temperatures above $800^{\circ}C$ are rapidly cooled by using a circular impinging water jet to determine their strength and toughness. In this study, the basic heat and fluid flow is solved by using the existing numerical model for boiling heat transfer. Actually, steel undergoes a phase change from austenite to ferrite or bainite during the cooling process. The phase change induces changes in its thermal properties. Instead of directly solving the phase change and the material cooling together, we solve the heat transfer only by applying the thermal properties that vary with temperature, which is already known from other studies. The effects of the changes in the thermal properties on the cooling of steel and the necessity of calculating the phase change are discussed.