• Title/Summary/Keyword: 열분석적 특성

Search Result 2,492, Processing Time 0.039 seconds

A Study on the Thermal Characteristics of a Coupler to Improve the Performance of Electrodeless Lamp (무전극 램프의 성능 향상을 위한 커플러의 열특성 연구)

  • Lee, Kye-Seung;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.487-495
    • /
    • 2017
  • The thermal characteristics of the electrodeless lamp are one of the main factors that determine the design and performance of the lamp. The coupler changes the impedance characteristic by heat and its use temperature is usually within about $150^{\circ}C$. In this study, we observed the phenomenon when the coupler was exposed at a temperature of $150^{\circ}C$ or higher, which has not been discussed so far. Two types of coupler A and coupler B with different spacing between the inner tube and the coupler were analyzed for electrical, thermal and optical properties and deterioration characteristics with different heat and heat shielding conditions. First, the impedance of the system is obtained and used as a criterion for analyzing the electrical characteristics through it. The diameters of the two types of couplers are 1 mm, and the experimental result shows that the coupler diameter is 1 mm, which can cancel out the loss of the magnetic field strength. Therefore, based on these results, when the coupler is exposed to high temperature of about $200^{\circ}C$, the efficient design method corresponding thereto is proposed.

An Experimental Study for Characteristics Evaluation of Cement Mortar Using Infrared Thermography Technique (적외선 화상기법을 이용한 시멘트 모르타르 특성의 실험적 평가)

  • Kwon, Seung-Jun;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.53-59
    • /
    • 2010
  • Recently, NDTs (Non-Destructive Techniques) using infrared camera are widely studied for detection of damage and void in RC (reinforced concrete) structures and they are also considered as an effective techniques for maintenance of infrastructures. The temperature on concrete surface depends on material and thermal properties such as specific heat, thermal conductivity, and thermal diffusion coefficient. Different porosity on cement mortar due to different mixture proportions can show different heat behavior in cooling stage. The porosity can affect physical and durability properties like strength and chloride diffusion coefficient as well. In this paper, active thermography which uses flash for heat induction is utilized and thermal characteristics on surface are evaluated. Samples of cement mortar with W/C (water to cement ratio) of 0.55 and 0.65 are prepared and physical properties like porosity, compressive strength, and chloride diffusion coefficient are evaluated. Then infrared thermography technique is carried out in a constant room condition (temperature $20{\sim}22^{\circ}C$ and relative humidity 55-60%). The mortar samples with higher porosity shows higher residual temperature at the cooling stage and also shows reduced critical time which shows constant temperature due to back wall effect. Furthermore, simple equation for critical time of back wall effect is suggested with porosity and experimental constants. These characteristics indicate the applicability of infrared thermography as an NDT for quality assessment of cement based composite like concrete. Physical properties and thermal behavior in cement mortar with different porosity are analyzed in discussed in this paper.

Experimental Studies for Solar Drying System of Agricultural Products(II) - Solar drying characteristics for rough rice - (태양열 건조 시스템에 관한 실험적 연구(II) - 벼의 태양열 건조 특성 -)

  • Koh, Hak-Kyun;Kim, Yong-Hyeon;Song, Dae-Bin;Park, Jae-Bok
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.21-30
    • /
    • 1991
  • In-bin grain drying experiments were performed to investigate the drying characteristics between natural air and solar heated-air drying system of rough rice. A computer simulation model for solar drying system of rough rice resulted in a good agreement between the experimental and predicted moisture content. In order to save the electric energy consumption of fan, airflow rates control system using inverter was developed and resulted in the effect of energy saving.

  • PDF

Runoff Characteristics Analysis of Drought Season in the Geumgang River Basin (금강 수계 갈수기 유출특성 분석)

  • Lee, Chung-Dae;Lee, Geum-Young;Park, Seok-Geun;Choi, Hyuk-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1298-1306
    • /
    • 2010
  • 그 동안 우리나라 수자원 관리의 주요 목적은 치수관리에 치중되어 있었으며, 이로 인하여 하상계수가 낮아지고 유황도 개선되어 도시 지역에서의 홍수발생은 거의 일어나지 않고 있다. 그러나 최근들어 급격한 산업화와 도시의 발달로 인하여 용수수요가 급증하여, 지속적이고 안정적인 용수공급이 한계를 나타내고 있으며, 또한 수질 악화 등과 같이 환경 문제 역시 발생하고 있다. 따라서, 수자원의 관리를 위하여 갈수기의 유출 특성을 파악하는 것은 매우 중요한 요소가 되었고, 이와 같은 문제들을 해결하기 위하여 갈수량의 조사는 필수적이다. 본 연구의 목적은 갈수량의 유출 특성을 파악하기 위해 2008년 금강 수계 수위관측소 지점에 대하여 유량측정을 수행하고, 측정된 성과를 기존 수위-유량관계곡선식에 적용하여 시계열 유량 자료를 획득하는데 문제가 없는지를 검토하였으며, 하천 지형 특성의 변화 및 수위 시계열의 변화 등을 파악하여 안정적인 갈수량 자료를 생산하는데 문제가 없는지 검토하였다. 금강 본류 및 1, 2차 하천의 41개 지점에 대하여 갈수량을 조사한 결과 안정적인 유량자료를 생산하는 지점은 9개소로 전체 중에 약 22%를 차지하고 있으며, 기존 수위-유량관계곡선식과 실측값 간에 오차가 발생하는 지점은 14개소로 전체 34%를 차지하고 있다. 또한 저수위 곡선식이 개발되지 않아 유량자료를 생산하지 못하는 지점이 18개소로 전체 약 44%를 차지하고 있는 것을 알 수 있다.

  • PDF

Dependences of Oxide layers on the Properties of the IGZO/Ag/IGZO Multi-Layer Films (산화물층에 따른 IGZO/Ag/IGZO 다층 박막의 특성 연구)

  • ;Lee, Sang-Ryeol;Kim, Hong-Bae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.351-351
    • /
    • 2013
  • 한국 전체 에너지 사용량 중약 24%의 에너지가 건축물 부분에 소비되고 있다. 건축물의 벽체나 유리창 등을 통해서 에너지 손실이 이루어지는데 유리창은 벽체에 비해 약 10배 이상 낮은 단열 특성을 가지고 있기 때문에 유리창을 통한 열손실량은 더 크다. 이러한 유리창 부분의 열손실 문제를 해결할 수 있는 방안으로 좋은 단열 특성 및 낮은 방사율을 가지고 있는 Low-e coating 방법을 사용하였다. 본 실험에서는 XG glass 기판 위에 IGZO/Ag/IGZO OMO 구조의 다층 박막을 증착하였다. RF magnetron sputtering방법을 이용하여 OMO 구조의 상부와 하부의 Oxide layer로 IGZO 박막을 증착하였다. 사용된 IGZO 타겟은 $In_2O_3$ (99.99%), $Ga_2O_3$ (99.99%), ZnO (99.99%)의 분말을 각각 1:1:1 mol% 조성비로 혼합하여 소결하여 제작하였다. Thermal Evaporator 장비를 이용하여 OMO 구조의 Metal layer로 Ag (99.999%)를 증착하였다. 실험 기판은 크기 $30{\times}30mm$의 0.7T XG glass를 사용하였다. OMO 구조의 산화층 IGZO 박막은 상/하층 동일 조건으로 기판 온도는 실온으로 고정하였으며, 초기 압력 $3.0{\times}10^{-6}$ Torr, 증착 압력 $3.0{\times}10^{-2}$ Torr, RF 파워 50W, Ar 유량 50 sccm로 고정시키고 증착 시간이 변화하면서 박막을 증착하였다. OMO 구조의 Metal layer로 Ag 증착 조건은 초기 진공도가 약 $6.0{\times}10^{-6}$ Torr 이하로 유지하고 기판을 2 Rpm의 속도로 회전시켰다. 이후 0.3 V로 Ag를 10분간 가열하여 충분히 녹인 후 Film Thickness Monitor로 두께를 확인하였다. OMO 다층 박막의 산화물층 변화에 따라 로이다층 박막의 구조적, 광학적 및 전기적 특성을 분석하였다. XRD 분석결과에 의하여 Bragg's 법칙을 만족하는 피크가 나타나지 않는 비정질 구조임을 확인할 수 있으며, AFM 분석결과에 통해서 최소 1.3 nm의 Roughness를 나타내었다. UV-Visible-NIR 분광광도계를 이용하여 다층 박막은 가시광선 영역에서 평균 80%의 광 투과성을 보여 IR 영역에서 평균 30% 투과하고 좋은 차단 특성을 나왔다. Low-e 특성을 갖는 유리창을 통해서 에너지 절약을 이룰 수 있는 것을 확인할 수 있었다.

  • PDF

Analysis of Urban Thermal Environment for Environment-Friendly Spatial Plan (친환경적 공간계획을 위한 도시의 열환경 분석)

  • Lee, Woo-Sung;Jung, Sung-Gwan;Park, Kyung-Hun;Kim, Kyung-Tae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.1
    • /
    • pp.142-154
    • /
    • 2010
  • The purpose of this study is to analyze the effects of various spatial characteristics on the land surface temperature and to grasp the characteristics of thermal environment by types of urban area in Changwon, Gyeongsangnam-do. The spatial data were consisted LST, normalized difference built-up index(NDBI) and normalized difference vegetation index(NDVI) obtained from Landsat 5 TM and land use and land cover map classified from high resolution digital aerial photograph($10cm{\times}10cm$). The unit space for spatial analysis was built by $500m{\times}500m$ Vector GRID. According to the results of estimation of relationship between thermal environment and spatial characteristics, LST had the highest positive correlation with NDBI by 0.929 and had high positive correlation with impervious area ratio by 0.857. In order to analysis of thermal environment on land use, types of urban area were classified by 4 of residential focus area, industrial focus area, green focus area and mixed area. According to the results of analysis, mean LST of industrial focus area was showed the highest by $21.10^{\circ}C$. But mean LST of green focus area was analyzed the lowest by $18.85^{\circ}C$. In conclusion, the results of this study investigated the effects of spatial characteristics on urban thermal environment and can provide methods and basic informations about land use planning and development density restriction for reduction of urban heat.

펄스 레이저 방식으로 증착된 $MgTiO_3$ 박막의 전기적 특성 분석

  • 안순홍;노용한;강신충;이재찬
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.71-71
    • /
    • 2000
  • 본 연구에서는 차세대 마이크로파 유전체 소자로서의 응용을 목적으로 펄스 레이저 방식에 의하여 증착된 MgTiO3 박막의 전기적 특성을 종합적으로 연구 분석하였다. 이를 바탕으로 MgTiO3 박막의 유전손실 등과 같은 열화를 야기시키는 박막 내부 또는 박막과 기판간의 결함의 특성을 파악하여 열화 메카니즘을 분석하였다. MgTiO3는 마이크로파 영역에서의 우수한 유전특성과 같은 낮은 유전손실을 가지며, 온도 안정성 또한 우수하다. 현재까지 벌크 세라믹 MgTiO3 의 응용 광범위하게 연구되어 왔으나 박막의 제조공정 및 전기적 특성 분석은 미흡한 형편이다. 따라서 벌크 세라믹과는 특성이 상이한 박막의 전기적 특성분석 및 연구가 필요하다. 분석을 위한 소자의 기본 구조로서 Metal-Insulator-Semiconductor(MIS) 구조를 채택하였다. MgTiO3 박막을 증착하기 위한 기판으로는 n형 Si(100)기판과 p형 Si(100)기판을 사용하였고, Si 기판 위에 급속 열처리기 (RTP)를 이용하여 SiO2를 ~100 두께로 성장시킨 것과 성장시키지 않은 것으로 구분하여 제작하였다. MgTiO3 박막은 펄스 레이저 증착 방식(PLD)에 의하여 약 2500 두께로 증착되었으며, 200mTorr 압력의 산소 분위기 하에서 기판의 온도를 40$0^{\circ}C$~55$0^{\circ}C$까지 5$0^{\circ}C$간격으로 변화시키며 제작하였다. 상하부의 전극 금속으로는 Al을 이용하였으며, 열증발 증착기로 증착하였다. 증착된 MgTiO3 박막의 결정구조를 확인하기 위하여 XRD 분석을 수행하였으며, 박막의 전기적 특성을 분석하기 위해 Boonton7200 C-V 측정기와 HP4140P를 이용한 경우에는 C-V 곡선에 이력현상이 나타났으나, MgTiO3/SiO2를 이용한 경우에는 이력현상이 나타나지 않았고, 유전율은 감소하는 것으로 나타났다. I-V 측정 결과, 절연층으로 MgTiO3/SiO2를 이용한 경우에는 MgTiO3만을 절연층으로 사용한 경우에 비해 동일한 전계에서 낮은 누설전류 값을 가짐을 알 수 있었다. 또한 박막의 증착온도가 증가함에 따라서 C-V 곡선의 위치가 양의 방향으로 이동함을 확인하였다. 위의 현상은 기판의 종류에 관계없이 발생하는 것으로 보아 벌크 또는 계면에 존재하는 결함에 의한 것으로 추정된다. 현재 C-V 곡선의 이동 원인과 I-V 곡선의 누설전류 메카니즘을 분석 중에 있으며 그 결과를 학회에서 발표할 예정이다.

  • PDF

Study on the Characteristics of Spatial Relationship between Heat Concentration and Heat-deepening Factors Using MODIS Based Heat Distribution Map (MODIS 기반의 열 분포도를 활용한 열 집중지역과 폭염 심화요인 간의 공간관계 특성 연구)

  • Kim, Boeun;Lee, Mihee;Lee, Dalgeun;Kim, Jinyoung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_4
    • /
    • pp.1153-1166
    • /
    • 2020
  • The purpose of this study was to analyze the spatial correlation between the heat distribution map of the satellite imaging base and the factors that deepen the heat wave, and to explore the heat concentration area and the space where the risk of future heat wave may increase. The global Moran's I of population, land use, and buildings, which are the causes of heat concentration and heat wave deepening, is found to be high and concentrated in specific spaces. According to the analysis results of local Moran's I, heat concentration areas appeared mainly in large cities such as metropolitan and metropolitan areas, and forests were dominant in areas with relatively low temperatures. Areas with high population growth rates were distributed in the surrounding areas of Gyeonggi-do, Daejeon, and Busan, and the use of land and buildings were concentrated in the metropolitan area and large cities. Analysis by Bivarate Local Moran's I has shown that population growth is high in heat-intensive areas, and that artificial and urban building environments and land use take place. The results of this research can lead to the ranking of heat concentration areas and explore areas with environments where heat concentration is concentrated nationwide and deepens it, so ultimately it is considered to contribute to the establishment of preemptive measures to deal with extreme heat.

An Evaluation of Human Thermal Comfort and Improvement of Thermal Environment by Spatial Structure (공간 구조별 열쾌적성 평가와 열환경 개선방안)

  • Lee, Jung-A;Jung, Dae-Young;Chon, Jin-Hyung;Lee, Sang-Moon;Song, Young-Bae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5
    • /
    • pp.12-20
    • /
    • 2010
  • The purpose of this study is to evaluate human thermal comfort by spatial structure and to explore solutions to improve the thermal environment of a small urban space. The study site was Korea University campus. Thermal conditions were measured to evaluate the quality of the thermal environment in each type of space within the study site. Micrometeorology measurements, analysis of space characteristics for using fish-eye lens photography, and thermal comfort modeling through the use of collected meteorological data, such as temperature and humidity, were performed. Results showed that the level of thermal comfort for humans differs depending on the types of space within the study site. Thermal comfort is better in open spaces than enclosed in the aspect of radiative mean temperature, Predicted Mean Vote(PMV), and Physiologically Equivalent Temperature(PET). This fact is probably due to shadows or buildings or trees that may block solar radiation. Thus, it is necessary to consider the spatial arrangements of buildings and trees to enhance openness and ventilation in the space. Paving materials and exterior building materials should also be selected to lower the radiant temperature. Given these results, a quantitative evaluation on human thermal comfort could propose a way to plan user comfortable small urban spaces. Study methods used and results provided in the study can promote a better way for urban space planning direction to improve environmental quality.

A Numerical Study of the Effects of Land Characteristics on the Air Cooling (지표면 특성에 따른 대기 냉각 효과에 관한 수치적 연구)

  • An, Jae-Ho;Kim, Tae-Wan;Lee, Sang-Eun
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.4
    • /
    • pp.264-271
    • /
    • 2004
  • A three-dimensional numerical mesoscale model by Pielke's estimation (University of Virginia Mesoscale Model, UVMM) was applied to investigate the effects of land characteristics including land-humidity, land-roughness and land-albedo on some micro-climatic coefficients and the air cooling capacity. The results indicated that land-characteristics exposed a significant effect on air cooling. Air cooling effects between in urban and agricultural areas were compared and the effects were much higher in agricultural area. Air cooling effects of weed species were different and when converted into economic values by diesel oil price the effects were ranged from 411 to 816 Won/plant.