• Title/Summary/Keyword: 열병합발전 투자

Search Result 33, Processing Time 0.02 seconds

Economic Feasibility Analysis of Building Seonam Biogas Combined Heat and Power Plant (서남 바이오가스 열병합발전 시설 건립의 경제적 타당성 분석)

  • Park, So-Yeon;Shin, Hyun-Ho;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.141-151
    • /
    • 2016
  • Recently, technology for energy recovery from waste has been increasing interest globally including the Korea. In Korea, we have interested in using biogas generated from the sewage treatment process. As one alternative, there are operating biogas combined heat and power plant. The generation amount of the Sewage Sludge are expected to grow in the future. For this reason, total processing cost of Sewage Sludge will increase. To solve this problem, it seems will be invested with the expansion of facilities that use biogas as energy. Therefore, quantitative information on such facilities is required. Thus, this study attempts to economic feasibility analysis for Seonam Biogas Combined Heat and Power Plant. Meanwhile, as the benefit items for economic feasibility analysis consider electricity supply benefit except for heat supply benefit. The average prices of electricity use were residence 123.69, commercial 130.46, and industry 102.59 won per kWh for the year 2015, In addition, the economic benefit are calculated to be residence 310.21, commercial 378.49, and industry 222.87 won per kWh. The results of economic feasibility analysis is NPV 72.18 billion won, B/C 1.90, IRR 37%, shows that economic validity of Seonam Biogas Combined Heat and Power Plant.

Study on the Small Scale CGS for APT. Complex (아파트 단지를 대상으로 한 소형 열병합 발전 시스템 검토)

  • 박화춘;박병식;정우용
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.221-227
    • /
    • 2000
  • The optimal capacity of CGS(Co-Generation Sys.) for APT. complex is 300kW output of electricity power from being considered the simple payback period, loss and benefit, and the running mode of CGS. The proper operation mode of CGS is as follows; If the demanding electricity load of APT. complex is within the range of capacity of generator(300kW), CGS is connected and operated with KEPCO grid. When the load ratio is over 50% of normal load of CGS(300kW), only CGS supply electricity demand. If not, the electricity line of CGS is exchanged to that of KEPCO.

  • PDF

Fuel cell based CHP technologies for residential sector (연료전지와 마이크로 열병합 발전기술)

  • Son, Young Mok
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.251-258
    • /
    • 2016
  • This article reports current status of micro fuel cell-combined heat and power (${\mu}FC$-CHP) systems which utilize both power and heat generated by fuel cells. There are several options for constructing CHP systems and among them, fuel cells are the most useful and their total energy efficiency combining heat and power can reach up to about 90%. Fuel cells are classified as five types based on the electrolyte, but the most suitable fuel cell types for the ${\mu}FC$-CHP system are proton exchange membrane fuel cells (PEMFCs) and solid oxide fuel cells (SOFCs). ${\mu}FC$-CHP systems have several advantages such as decrease of the transmission-distribution loss, reduced costs of electricity due to distributed power generation, and environmental-friendliness owing to zero emission. The main drawback of the ${\mu}FC$-CHP systems is the high initial investment, however, it keeps decreasing as the technology development reduces production costs. Currently, Japan is the most leading country of the ${\mu}FC$-CHP market, however, Korea tries to expand the market by planning the deployment of 1 million units of ${\mu}FC$-CHP systems and governmental subsidiary supporting of half of the install price. In this report, integration technologies for connecting FC and CHP, and technology trends of leading countries are presented as well.

에스코국내소식

  • Korean association for escos
    • The Magazine for Energy Service Companies
    • /
    • s.38
    • /
    • pp.78-81
    • /
    • 2006
  • 지역난방공사 광주에 구역형 집단에너지사업 추진/대한상의 기업 70% 에너지절약 설비 투자계획/미국 수소불화탄소 줄이기 운동/산업자원부 올신·재생에너지 지원금 4095억원/윌로펌프 세계최초 저소음 상향식 가압펌프 개발/한국수자원공사 시화호조력발전단지 CDM사업 승인/포스코건설 고양시 환경에너지시설 사업자 선정/산자부 제1차관에 김종갑 특허청장 내정/열병합발전협회 정기총회 및 이사회 개최/에관공 M&V보완·관리업무 ESCO영역 추가/청주도시가스 열병 합 발전 설명회 열어/뉴욕주 에너지 절약 납세자에 세금감면 혜택/삼성엔지니어링 매출액은 감소,순이익은 증가/한국하니웰 A&S International의 '2005 올해의 우수제품'에 선정/에너지경제연구원 아주대 인력양성 MOU체결/코오롱정보통신 "에너지 서비스사업 진출"

  • PDF

Influence of District Heating Return Temperature on Performance of Steam Turbine in Cogeneration Plant (지역난방 회수온도가 열병합발전소 증기터빈 성능에 미치는 영향 연구)

  • Kim, Jonghyun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.14 no.3
    • /
    • pp.42-48
    • /
    • 2018
  • If the combined operation of Gwanggyo Cogeneration plant is similar to that of 2017, the CHP return temperature is lowered to $4^{\circ}C$, $6.3^{\circ}C$ and $7.8^{\circ}C$ according to the increase of heat surface area and the electric power is increased by 413 kW and 676 kW from its original 39,025 kW, and when the heat surface area is increased 75% electric power increases by 834 kW, totaling 39,859 kW. NPV, which is an economic analysis standard, is worth 350 million won, 500 million won, and 520 million won, and all measures to increase the heat surface area are proven to be worth the investment. As the heat transfer area increased, the electric power and NPV increased proportionally but the rise amount decreased. The electrical output and NPV were found to be the highest among the three options when the heat transfer area was increased by 75%.

  • PDF

The Subsystems of 200kW PAFC-PC25 and its Commercialization Prospects (200㎾급 인산형연료전지 (PC25)의 구성시스템과 상업화 전망)

  • 오영삼;전진석;최동수;방효선
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.28-32
    • /
    • 1994
  • 에너지이용/발전시스템의 개발은 미래의 급격한 전력수요증가 패턴과 에너지소비에 수반되는 환경문제들의 해소 그리고 에너지절약 측면에서의 이용효율 향상 및 열병합(CHP)시스템 구축 등으로 막대한 투자가 요구되고 있는 분야이다. 이 중 에너지의 효율적인 이용과 환경문제와 연계되어 주목을 받고 있는 연료전지는 연료의 cold burning을 통하여 화학에너지를 직접 전기에너지로 변환시키는 electrochemical devices로서 부수적으로 발생되는 배열을 효과적으로 이용할 수 있는 고효율, 저공해 발전시스템이라고 할 수 있다.

  • PDF

Basic Economic Evaluation of Industrial Complex CHP based on the type of Turbine (산업단지 열병합 발전 방식의 터빈 형식에 따른 기초경제성 평가)

  • Seo, Young-Ho;Lee, Joon-Hee;Cho, Chung-Sik;Jeon, Yong-Han;Yeom, Won-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.624-627
    • /
    • 2011
  • 본 논문에서는 산업단지에 공정증기를 공급하는 열병합 발전소 건설에 대한 타당성 분석시 적용되는 경제성 분석에 대한 것으로, 동일한 보일러 및 주증기 그리고 공정증기 조건하에서 배압터빈 및 복수터빈 적용시 수반되는 경제성 분석을 통해 타당성 있는 시스템을 선정하는데 그 목적이 있다. 복수터빈 방식이 배압터빈 방식에 비해 전력생산량은 약 3배정도 많으나 초기 시설투자비의 증대 및 상대적인 에너지 활용측면에서 낮은 결과를 나타냈다.

  • PDF

An Analysis on Technology for Domestic Geothermal Power Plant (한국형 지열발전 기술 분석)

  • Chang, Ki-Chang;Baik, Young-Jin;Yoon, Hyung-Kee;Na, Ho-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.571-571
    • /
    • 2009
  • 지열은 날씨와 기온 등에 영향을 받지 않고 연중 가동할 수 있어 기저부하를 담담할 수 있는 유일한 신재생에너지 자원이므로 이에 대한 기술개발이 시급하다. 우리나라는 비화산지대이며 지중 온도가 가장 높은 지역의 5km에서 약 $170^{\circ}C$ 내외이므로 외국에 비해 지온경사도가 크지 않은 편이다. 그리고 3km 이상에서는 지하대수층이 거의 존재하지 않기 때문에 지열발전을 위해서는 EGS 기법을 도입할 수 밖에 없는 실정이다. 그리고 지열수를 확보할 수 있는 온도범위가 약 $100{\sim}150^{\circ}C$ 정도이므로 이에 적합한 지열발전 플랜트를 선정할 필요가 있다. 일반적으로 지열발전에 적용되는 플랜트는 건증기 지열발전, 플래쉬증기 지열발전, 바이너리 사이클 지열발전으로 분류할 수가 있으나 국내 여건에 맞는 방식으로서 바이너리 사이클 발전으로서 ORC 플랜트 또는 Kalina 사이클 플랜트가 적합하므로 이에 대한 기술 개발이 적극적으로 이루어져야 한다. 따라서 국내 지열발전의 기술개발에 있어서 핵심요소는 심부천공 및 EGS를 위한 인공파쇄기술과 지상 플랜트로서 저온지열 발전 플랜트의 기술확보가 필요한 실정이다. 이와 같은 기술개발이 완성되면 발전 뿐만아니라 집단지역난방, 온실 및 양어장 등에도 열공급이 가능한 열병합발전이 가능하게 될 것이다. 또한, EGS 기술로서 상업적 성공을 이룬 것은 세계적으로 2~3개 사례에 불과한 신기술로서, EGS 기술의 국내 조기 실현으로 기술 선점 및 해외 수출을 모색할 필요가 있다. 그리고 심부 지열자원은 국내 어디에나 부존하는 ubiquitous 자원이며 이산화탄소 배출이 전무한 청정 국산 에너지 자원이나, 이의 개발에는 높은 초기 투자비와 risk를 요하므로 민간 업체의 투자가 제약을 받는다. 따라서 정부의 적극적인 지원하에 산.학.연 중심으로 시범보급이 우선 이루어진 후 민간의 자발적 투자를 통한 지열 개발을 유도할 필요가 있다.

  • PDF

A Study on Myanmar Power Marker for Korean Firms - Focused on CHP, CDM, MDB - (한국기업의 미얀마 전력시장 진출 방안에 관한 연구 - CHP, CDM, MDB를 중심으로 -)

  • Yu, Cheon;Hwang, Yun-Seop
    • International Area Studies Review
    • /
    • v.20 no.4
    • /
    • pp.37-56
    • /
    • 2016
  • The purpose of this research is to present the implication for Korean firms' entry into the power market in Myanmar. This study investigated the characteristics of the Myanmar power market and analyzed SWOT, focusing on energy policy, power supply and demand, energy relations with neighboring countries and climate change issue. Opportunity factors are changes in energy strategies, the launch of an energy integration organization, changes in the power energy portfolio, rapid economic and power demand growth, and a clean development mechanism. The threats are high nonfulfillment of a contract, high power loss rates and low electricity distribution rates, increased energy exports to neighboring countries, and vulnerability to climate change. We suggest the use of CHP (Combined Heat and Power), Clean Development Mechanism (CDM), and Multilateral Development Bank (MDB).

Energy and Economic Analysis of Heat Recovery Cogeneration Loop Integrated with Heat Pump System by Detailed Building Energy Simulation (건물 에너지 상세 해석을 통한 소형 열병합 발전 및 히트펌프 복합 시스템의 경제성 분석)

  • Seo, Dong-Hyun;Koh, Jae-Yoon;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.71-78
    • /
    • 2009
  • Up until recently, the energy and the economic analysis of a cogeneration system have been implemented by a manual calculation that is based on monthly thermal loads of buildings. In this study, a cogeneration system modeling validation with a detail building energy simulation, eQUEST, for a building energy and cost prediction has been implemented. By analyzing the hourly building electricity and thermal loads, it enables users to decide proper cogeneration system capacity and to estimate more accurate building energy consumption. eQUEST also verified the energy analysis when the heat pump system is integrated with the cogeneration system. The mechanical system configuration benefits from the high efficiency heat pump system while avoiding the building electricity demand increase. Economic analysis such as LCC (Life Cycle Cost) method is carried out to verify economical benefits of the system by applying actual utility rates of KEPCO(Korea Electricity Power COmpany) and KOGAS(KOrea GAS company).